Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹14.0 L+₹4.8 L (51.4%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹14.9 L+₹5.6 L (61.0%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
3 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) NO 02 JODHPUR
GE (AF) NO 02 JODHPUR
REPAIR AND MAINT INCLUDING REWINDING OFCEILING FANS/EX FANS/WALL FANS, REPAIRS TO ELECTRIC GEYSERS AT OMQ,SMQ AND OTM ACCN AT OUTER AND INNER POCKETS DOMESTIC AREA OF 32 WING UNDER AGE E/M GE (AF) NO 02 JODHPUR
2022_MES_538964_1
8317/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) NO 02 JODHPUR
AS PER TENDER
7 documents required · 7 mandatory
₹500
Yes
GE (AF) NO 02 JODHPUR
₹30,000
Yes
17 Aug 2022
18 Jul 2022
6 Aug 2022
19 Jul 2022
3 Aug 2022
22 Jul 2022
20 Jul 2022 - 21 Jul 2022
Amount
Labour only for attending complaints of unserviceable ceiling fans, exhaust fans and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner domestic area) carrying out necessary repairs at site by replacing unserviceable spares or taking down carefully unserviceable ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades and removing fan and blade to workshop for carry out necessary repairs or deposit unrepairable fans/ex-fans to E/M Store yard for safe coustody all as directed and specified. All connecting wiring shall be PVC insulated single core stranded copper condutor of size 0.5 sqmm with proper color coding drawn through heat insulation sleeves of suitable size. Note : Necessary spare parts required to repair at site shall be measured and paid separately under relavant items. Necessary deposit receipt shall be provided to users for taken down fan/exhuast fan as per prescribed printed format to be arranged by contractor. Contractor shall arrange necessary transportaion to bring the taken down ceiling/exhaust fans for repair/replacement.
M&L for re-winding of burnt ceiling fans by opening covers of ceiling fan, remove the burnt winding, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bearings No 6201/6202 for 1200/1400mm sweep, greasing, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5 mfd and making connection with fan capacitor and connector block, transporting back after repair, assembling the blades and hanging the fan in its own position to existing fan clamp and down rod with necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. Note : 1. Quoted rates shall deems tobe inclusive cost of warnish, insulation papers, sleeves, cotton tape for bining coils including minor spare like nuts, washer, screws, tension spring required for assembiling and fixing fans in position. 2. Fan bearing & fan capacitor if required shall be measured and paid seperately under relavant item. 3. Fan re-winding & replaced bearings will be inspected by Engr-in-Charge before assembling the fan motors.
M&L for re-winding of burnt ex-haust fan/wall fans motor of following size sweep fans by opening covers by unscrewing nuts/screws, remove the armeture shaft and checking for its defects, checking defects in stator core & widings, cutting burnt widing of stator, cleaning the slots and rewinding the fan with supper enammeled copper wire of same wire gauge, warnishing after winding, drying, replacing unserviceable fan bush/bearings, greasing, replace of armeture coil with complete shaft if required, soldering the copper terminal of winding with single core copper multistraded wire of 0.5 sqmm and re-assembling fan, replace of fan capacitor 2.5/4.0mfd and making connection with fan capacitor and connector block, re-assembling fan exhaust fan with frame and blade, transoporting back after repair, fixing the exhust fan in its own position to existing fan clamp or with new screws and guttis or necessary Nut, bolt and washer and testing for smooth functioning after complete repair all as ditrected at site. All connecting wiring shall be PVC insulated single core stranded copper condutor of size 0.5 sqmm with proper color coding drawn through heat insulation sleeves of suitable size. Note : 1. Quoted rates shall deems tobe inclusive cost of warnish, insulation papers, sleeves, cotton tape for binding coils including minor spare like nuts, washer, screws, tension spring required for assembiling fans. 2. Exhaust fan bearing/bush, blade, frame & capacitor if required shall be measured and paid seperately under relavant item. 3. Armeture coil with complete shaft if required shall be measured and paid separately under relavant item. 4. Fan re-winding & replaced Armeture will be inspected by Engr-in-Charge before assembling the fan motors.
(a) Exhaust fan motor of 225/250mm sweep.
(b) Exhaust fan motor of 300mm sweep exhaust fans
(c) Exhaust fan motor of 450mm sweep exhaust fans
(d) Exhaust fan motor of 400/450mm sweep wall fan/pedestal fans
(e) Exhaust fan motor of 600mm sweep wall fan/pedestal fans
Supply only in repairs fan bearing of size 6101 suitable for ceiling fan 1200/1400mm sweep
Supply only in repairs fan bearing of size 6202 suitable for ceiling fan 1200/1400mm sweep
Supply only in repairs fan capacitor 2.5 Mfd suitable for ceiling fan 1200/1400mm sweep
Supply only in repairs fan capacitor 4.0 Mfd suitable for exhaust fan 300/450/600mm sweep.
Supply only in repairs fan down rod 18 inch long for hanging ceiling fan 1200/1400mm sweep.
Supply only in repairs fan down rod 21 inch long for hanging ceiling fan 1200/1400mm sweep.
Supply only in repairs fan down rod 24 inch long for hanging ceiling fan 1200/1400mm sweep.
Supply only in repairs new armeture suitable for existing exhaust fan motor of 225mm sweep.
Supply only in repairs new armeture suitable for existing exhaust fan motor of 250mm sweep.
Supply only in repairs new armeture suitable for existing exhaust fan motor of 300mm sweep.
Supply only in repairs new armeture suitable for existing exhaust fan motor of 450mm sweep.
Supply only in repairs new armeture suitable for existing wall/pedestal fan motor of 400mm sweep.
Supply only in repairs new armeture suitable for existing wall/pedestal fan motor of 450mm sweep.
Supply only in repairs new armeture suitable for existing wall/pedestal fan motor of 600mm sweep.
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Fan taken down against item No 01 shall be used after complete repairs and testing.
Fixing only exhaust fan/wall fans, 300/450mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Exhaust Fan/wall fans taken taken down against item No 01 shall be used after complete repairs and testing.
M&L for cutting holes 300mm diameter for preaparing opening through brick/stone masonary wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall all as directed by Engr-in-charge at site
Labour only for attending complaints of unserviceable electric geysers and its allied electrical repairs at domestic area of AF station Jodhpur (Outer and Inner pockets) carrying out necessary repairs at site by taking down carefully unserviceable geysers by disconnecting electrical connections, unsecrewing from position, carry out necessary minor repairs at site and re-install the geyser after repair at site or removing geysers to workshop for major repairs (like repairs to inner tank or body) or deposit unrepairable geysers to E/M Store yard safe coustody all as directed and specified. Note : Necessary spare parts required to repair at site shall be measured and paid separately under relavant items. Necessary deposit receipt shall be provided to users for taken down Geysers as per prescribed format given MES. Contractor shall arrange necessary transportaion to bring the taken down geysers for repair/replacement.
Supply and fix in repairs Heating element copper body chromium plated of rating 1.5 KW, 230 volts ISI marked, 10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Supply and fix in repairs Heating element copper body chromium plated of rating 2.0 KW, 230 volts ISI marked, 8/10 inch long, and dia of tube not less than 8.5mm, triangular or cup type base including rubber washer suitable for old pattern geysers complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Supply and fix in repairs Heating element for new model enegry efficient geysers, copper body chromium plated of rating 2.0 KW, 230 volts ISI marked, 10 inch long, and dia of tube not less than 8.5mm, cup type base including rubber ring washer suitable complete all as specified and as directed by Engineer-in-charge. Make-Bajaj/Airex/HotMax/Crompton/Venus or any other equivalent approved make.
Supply and fix in repairs Thermostat (8/10 inch long) auto cut with thermal setting upto 80 degree centigrade, 230 V, for the geysers 25/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs Thermostat (8/10 inch long) auto cut with trip reset push button type, 230 V, for the geysers 25/50 Ltrs capacity as per site requirement fixed in repairs complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs capillary type Thermostat suitable for new gernation energy efficient geyser for tempterature control auto cut function, 230 V, size and capacity as per site requirement complete all as specified and as directed by Engr-in-Charge .
Supply and fix in repairs Non return valve 15mm bore,as per site requirement complete all as specified and as directed by Engr-in-Charge
Supply and fix in repairs LED Indicator lamp red/green complete all as diercted by Engr in Charge
Supply and fix in repairs Apparatus base plate (Geysers assembly) suitable for existing Geysers of Cap 25 Litres of copper /brass complete with nuts and bolts and rubber washers complete all as specified and directed by Engr in Charge.
Supply and fix in repairs Apparatus base plate (Geysers assembly) suitable for existing Geysers of Cap 50 Litres of copper /brass complete with nuts and bolts and rubber washers complete all as specified and directed by Engr in Charge.
Supply and fix in repairs Heat resistant heavy duty pressure grade 6 kg/sq cm, stainless steel wiremesh braided HOT & COLD flexible PVC connecting pipe with brass adapters 450 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge. Make-Havells/Crompton or as per approved makes.
Supply and fix in repairs Heat resistant heavy duty pressure grade 6 kg/sq cm, stainless steel wiremesh braided HOT & COLD flexible PVC connecting pipe with brass adapters 600 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge. Make-Havells/Crompton or as per approved makes.
Supply and fix in repairs Heat resistant heavy duty pressure grade 6 kg/sq cm, stainless steel wiremesh braided HOT & COLD flexible PVC connecting pipe with brass adapters 750 mm long suitable for 15 mm dia pipe and fixed in position as in repairs complete all as approved by Engineer-in-charge. Make-Havells/Crompton or as per approved makes.
Installation only Electric Storage type water heater (Geysers) 25/50 Ltr capacity with standard fixing accessories including suitable size wall fastener bolts & Nuts, gutties etc complete all as specified and directed. NOTE: Taken down geyser against item No 22 shall be issued after repairs at store yard.
Supply and fix in repairs 3 Pin Plug Top 16 Amps, 240 volt insulated bakelite body(Ivory/White)
Supply and fix in repairs 2 pin Earth metal clad Plug Top 16 Amps, 240 volt.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN 32Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Note for Item No 1.0 to 41.0 :- (a) The contractor will be alloted complaint of fan and geysers daily basis and sufficient resources will be deployed by him/her for completion of day to day comaplaint within 24 Hrs from the time of reporting. Any delay beyond above mentioned time limit suitable penalties as mentioned in relavant clause of Contract or Rs. 100.00 for each unattended complaint will be recovered in work done amount. (b) A detailed log of complaints with completion/non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him. (c) The contractor shall install fan re-winding machine at AGE E/M store yard and a skilled electrician will be employed to carry out rewinding of fans in working hours from 9.00am to 5.00pm. (d) The contractor will make suitable trnsport arrangment for attending complaint of fan and geysers and arrange conveyance for bringing/delivering fans/exhaust fans. He will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint. In case of any dispute the decision of accepting officer will be final and binding in this regard. (e) The quoted rated deems to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered area of AF Station Jodhpur. (f) The contractor will maintain necessary record of deposited fans and issued after repairs on printed format of deposit/receipt slip book and the same will be reviewed periodically by Engr-in-charge to streamline complaints disposal system.
S&F in repair Exhaust fan 450 mm sweep, heavy duty, metal body, four blade, air delivery shall not be less than 350 CFM at 1440 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
S&F in repair Wall mounting fan 400/450mm sweep, heavy duty, metal body, 240 volt, single phase, 50 cycle per second, AC supply, air delivery shall not be less than 400 CFM at 1440 RPM and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including writing MES No with black paint as directed by engr-in-charge and fixed in position as recommended by manufacturer complete all as specified.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
M&L for taking out old unserviceable lovers shutters of exhaust fans from external face of walls from double/tripple storey buildings and providing aluminium wire mesh (3 to 4 mm mesh) with Aluminium frame (Guage thickness not less than 1.2mm) including necessary fixing accessories (like clamps, screws, wahsers, gutties etc) to prevent entry of birds/insects through opening of exhaust fans on walls. Approximate size of frame tobe provided at site is 400mm x 400mm for 300mm dia openings holes and 600mm x 600mm for 450mm dia openings holes. Note : Necessary T&P such as ladders, safety belts, drilling equiptments for fixing Wiremesh at heights of double/tripple storey building shall be arranged by the contractor and cost for the same deems tobe included in quoted rates.
M&L for Painting of ceiling/exhaust fans complete with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc and writing MES No with black paint as directed by Engr-in-Charge. Note : Painting of ceiling fans tobe carried when the body is opened for repair works for re-winding to avoid bearing Jam due to paint and motor shall be assebled after drying of paint.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .