Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.4 LAccepted-Finance | L1 | Accepted-Finance Due to L1 | |
| 2 | L2₹70.1 L+₹1.8 L (2.61%)Rejected-Finance | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹76.3 L+₹7.9 L (11.6%)Rejected-Finance | L3 | Rejected-Finance Due to L3 | |
| 4 | L4₹83.2 L+₹14.9 L (21.7%)Rejected-Finance | L4 | Rejected-Finance Due to L4 | |
| 5 | Rejected-Technical | - | Rejected-Technical Requisite technical supporting documents not availabe |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
7 Dec 2023, 10:00 amClosed
Director CSIR-CBRI
Roorkee
2023_CSIR_174846_1
72(VID) /TSG /NTRF / 2023-24
Open Tender
Electrical Works
Item Rate
90 days
Director CSIR-CBRI Roorkee
10 documents required · 10 mandatory
₹1,180
Director CSIR CBRI
₹1.5 L
9 Jan 2024
17 Nov 2023
8 Dec 2023
17 Nov 2023
7 Dec 2023
17 Nov 2023
Amount
Transformer Specifications: 1000KVA, copper wound 11/0.433 KV, 50 Hz, Delta transformer with OLTCfor Voltage regulation andincluding standard fittings ,Name, Rating and Diagram Plate, Earthing terminals, Lifting lugs, Oil Level Indicator, Filter Valve With Plug, Drain cum sampling valve, Conservator with oil filling hole, Thermometer pocket, Dial type oil temperature indicator with max. Indicating pointer, Air release plug, Dehydrating Breather, Explosion vent, Inspection Cover, First Filling of Transformer Oil confirming to IS: 335, Marshaling Box with control wiring, Buchholz Relay, Oil Temperature Indicator, winding Temperature Indicator, Magnetic oil level gauge, Jacking pads& LV busbar. The transformer shall be tested and shall be meeting to IS:1180 Level I, Amendment-4 Std A. Technical Specifications for 1000kVA DTf. With OLTC as per IS:1180 Level I, Amendment-4 Std
i. Capacity in KVA-1000kVA , ii. Type- Distribution Transformer iii. Transformer design & testing- IS 1180 Level – I Amendment – 4 Std, iv. Loading- IS 6600 v. Oil- IS 335, vi. Porcelain bushing- IS 3347, vii. Tolerance on electrical parameters- IS 2026 viii. Duty- Continuous duty, ix. Windings- E.G. Copper, x. Core- M3, xi. Type- Outdoor xii. Rated Input-11 Kv, xiii. Rated Output-.433 KV, xiv. Frequency-50 Hz, xv. No. of Phases- 3 xvi. Input configuration- Delta, xvii. Output Configuration- Star, xviii. Vector Group- Dyn 11 xix. No. of Steps-16, xx. Tapping(OLTC) - -5% to +15% in steps of 1.25% xxi. Cooling- Natural Convection Oil Cooling/Natural Convection Air cooling (ONAN) xxii. Max. Ambient temperature - 50º C, xxiii. Max. Oil temperature rise - 40º C xxiv. Max. Winding temperature rise - 45º C, xxv. HV side High voltage withstand test - 28 KV xxvi. LV side High voltage withstand test - 3 KV, xxvii. Mounting of cooling radiators- Fixed xxviii. Applied on LV side-0.866 KV, xxix. Induced on HV side-22 KV, xxx. HV side- Cable Box xxxi. LV side- Bus Duct, xxxii. Neutral- Provided, xxxiii. Losses at 50% Load at 75°C - 2.79W xxxiv. Losses at 100% Load at 75°C - 7.70kW
Electrical distribution panel consisting of 1 incomer, 3 outgoing and 1 bus coupler with following detailed specifications:
1.Electrical distribution panel Specifications: i. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. ii. 2 No. earthing terminals shall be provided for distribution panel. iii. Panel, fabricated out of 14 gaugeCRCA sheet steel in cubicle. Formation and compartment alized free standing floor mounted dust and vermin proof. iv. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panel. v. Panels shall be treated with all anticorrosive process before powder coating. vi. Indicator lights shall be provided to mention status for all compartments. vii. All bus bar section/ backside panels shall have pad locking facility and hinged type door. viii. Wiring and supply for installation of space heater, humidistat and control MCB’sshall be provided for all vertical sections. ix. Incoming breakers shall have suitable provision for busduct connection. x. Approval shall be taken on final design before fabrication.
3. Bus Bar Specifications: i.2000 A TPN electrolytic Al bus bar with heat shrinkable insulation sleeve.
4. Outgoing Specifications: Outgoing breakers with under voltage release and shall be electrically operated manually draw out type with electrical/microprocessor release unit, and all outgoing feeders shall be provided with built-in over current, short circuit, under voltage& earth fault relay module i.1000 Amps 4 Pole, 50KA Breaking capacity ACB - 1 No. ii. 1000 Amps 4 Pole 50KA Breaking capacityACB - 1 No. (Spare) iii. 630 Amps 4 Pole MCCB - 1 No. (For APFC unit) All outgoing shall have dual Electronic meter with required number of CT's.
5. Bus Coupler Specifications: i. 2000 amps 4 pole, 65 KA breaking capacity ACB, with ON/ OFF/ TRIP indicating lamps with microprocessor release unit.
Isolator Switch of 11kV, 630A, 21kA for 3 sec Outdoor, SF6 Gas Insulated switchgear with 01 nos direct cable module and 01 no. Manually operated Vacuum Circuit Breaker.
HT Switchgear Specifications : Indoor type 11KV VCB Switchgear Panel with 1 incoming panel and 2 outgoing panel with each outgoing panel consisting of following specifications:
B. The equipment shall be totally enclosed in MS sheet enclosed cubical, dust and vermin proof with necessary isolation arrangement at the incomer side. Each panel shall be easily extensible on either side and should be complete with necessary internal copper connections, small wiring, L.T. fuses and supporting framework with bolts to secure it to the floor. Each panel shall be provided with space heater, door switch with lamps and 15 - Ampere power receptacle.
C. The breakers shall have the following ratings: i.Type- Vacuum type ii.No. of poles-3 iii. Nominal System Voltage-11 KV iv. Highest System Voltage-12 KV v. Rated frequency-50+1.5Hz vi. Rated continuous current rating at Ambient temperature, as specified in IS: 13118 -1991-800 Amp Busbar current vii. Busbar Chamber-800 A copper bus bar, heat shrinkable PVC sleeved /powder coated with colour code. The current density 1.5 Amps/sq. mm. The busbar shall be high conductive electrolyte copper. viii. Impulse withstand test voltage-75 KV (peak) ix. One minute power frequency withstand test voltage-28 KV (rms x. Short time current rating Not less than-18.4 KA for 1 Second. xi. System neutral- Solidly earthed.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long ,G.I. tube ,having single prong at top with 85 mm dia 6mm thick G.I. base plate including holes etc. Complete as required.
Supply & Fixing of lighting conductor air termination system (copper made-multi prong) with base plate including holes etc. Complete as required.
Jointing copper /G.I. tape (with another copper/G I tape, base of the finial or any other metallic object) by riveting /nut boiting /sweating and soldering etc as required.
Providing and fixing G.I. tape 20mm*3mm thick on parapet or surface of wall for lighting conductor complete as required .(For vertical run )
Providing and laying G.I. tape 32mm*6mm from earth electrode directly in ground as required.
Earthing with copper earth plate 600mm*600mm*3mm thick including accessories ,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal /coke and salt as required.
Supplying and laying 75mm*15mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring washer etc. as required .(jointing shall be done by overlapping and with 2 sets of G.I . nut bolt & spring washer spaced at 50mm).
Excavating trenches of required width upto 1.5 m depth including getting out the excavated soil, laying the cable in the same trench with protective covering including returning the soil as required in layers not exceeding 20cm in depth including consolidating each layer by ramming, watering etc. and disposing surplus excavated soil as directed with in a lead of 50m,dressing of sides all as required for pipe, cable etc not exceeding 400mm dia.
Supplying and Laying HT 185 sq mm 3 core 11KV Alluminium conductor
Supplying and Laying LT 240 sq mm 4 core 11 KV Alluminium conductor cable 200 meter.
Construction and civil works for the installation of Transformer (complete in all respect as directed by Engineer In-charge)
Avon Electricals
MEC ENGINEERS
SSPL Enngineers & Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .