Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹35.7 L+₹2.7 L (8.24%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
20 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chiloda
GE (AF) Chiloda, Lekawada Patia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
CLEANING OF SEWAGE LINES, SOAKAGE WELL AND SEPTIC TANK AND OTHER MISC B/R WORKS AT VSN CHILODA
2024_MES_655840_1
8155/24-25/E8
Open Tender
Civil Works
Item Rate
270 days
VAYU SHAKTI NAGAR CHILODA
As Per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹70,000
Yes
4 Sept 2024
25 May 2024
22 Jun 2024
25 May 2024
20 Jun 2024
8 Jun 2024
25 May 2024 - 7 Jun 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5 in depth and getting out in soft soil complete all as specified and directed.
All as per Item No. 01 above, but depth exceeding 1.50m.but not exceeding 3.00m complete all as specified and directed.
Returning, filling in, including spreading , levelling , watering and well ramming in layers not exceeding 25 cm thickness in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Demolition of brick work of any description and in any position , built in cement mortar complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6 mtr mean radius, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster on brick or stone masonry wall etc incl racking out joints haking for key, scrubbing down with water etc as in internal and external surfaces of man holes, septic tank, filter bed, drains, walls, paver blocks etc complete all as specified and directed.
M&L for 5mm thick rendering in cement mortar (1:4) (as second coat), over and including 10mm thick rendering in cement mortar (1:6) (as first coat) as in manholes,septic tank,filter bed,of fair faces of brick work or concrete surfaces of wall, incl mixing only intergal water proofing compound in second layer only as per manufacturer’s instructions, finished the surface even & smooth without using extra cement complete all as specified and directed. (Note : - WPC will be measured and paid separately)
M&L for 15 mm thick rendering in CM 1:6 on concrete surfaces / fair faces of brick masonary wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over after application of cement base wall care putty complete all as specified and directed.
Supply only liquid water proofing compound (ISI marked) complete all as specified and directed.
Demolition of Cement concrete of any description and in any position not otherwise specifically provided including removal of debries to a distance exc 1.5 Km but n. exc 2 Km complete all as specified and as directed.
M&L for PCC 1:3:6 type C-1, (using 20mm graded crushed stone aggregate) as in coping or benching of manhole etc necessary form work finished fair and even surface without using extra cement including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M&L for providing cement concrete type C-2, 1:3:6 (using 20mm graded crushed stone aggregate) as in surface channels and drains complete all as specified and directed.
M&L for forming fair finished drain or channel 50 CM inner girth in Cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed.
M&L for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
Demolition and breaking up 150 mm bore salt glazed stone ware drain pipe (SGSW), RCC NP-2 pipe / RCC NP-4 pipe incl PCC packing under hunching against the sides of bed and complete PCC bed complete all as specified and directed.
All as per Item No. 17 above, but 200 mm bore pipe.
All as per Item No. 17 above, but 250 mm bore pipe.
All as per Item No.17 above, but 300 mm bore pipe.
M&L for 150 mm bore salt glazed stone ware (SGSW) drain pipe, of class 'A' laid in trenches and jointed in CM 1:1 complete all as specified and directed.
All as per Item No. 21 above, but 200 mm bore pipe.
All as per Item No. 21 above, but 250 mm bore pipe.
All as per Item No. 21 above, but 300 mm bore pipe.
M&L for reinforced concrete pipe, class NP-2, 150mm bore pipe, laid and jointed complete with collars, jointed with cement mortar (1:1) complete all as specified and directed.
All as per Item No.25 above, but 200 mm bore pipe.
All as per Item No.25 above, but 250 mm bore pipe.
All as per Item No.25 above, but 300 mm bore pipe.
M&L for concrete bed to drain pipes including packing under pipe, and haunching against both sides in PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) against the side of SWG/RCC pipes after they are laid and tested for 150 mm bore pipe complete all as specified and directed.
All as per Item No.29 above, but for 200 mm bore size RCC/SWG pipe.
All as per Item No.29 above, but for 250 mm bore size RCC/SWG pipe.
All as per Item No.29 above, but for 300 mm bore size RCC/SWG pipe.
M&L for cutting into existing manholes for connecting new drain, making good to pipe and rendering , cutting out existing benching for forming brackets channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) and reforming benching as required for 150 mm bore pipe complete all as specified and directed.
All as per Item No. 33 above, but for 200 mm bore size pipe.
All as per Item No. 33 above, but for 250 mm bore size pipe.
All as per Item No. 33 above, but for 300 mm bore size pipe.
M&L for cleaning of 100 users brick/stone masonary septic tank, removing sludge and taking out from the septic tank, loading in lorry/cart , depositing beyond the limit of MD land including bailing out water either manually or mechanically including obtaining earth from outside MD land and spreading over the area to cover bailed water complete all as specified and directed.
Dewatering of foul water from soakage pits of size 3.6 M dia and 6.0 M deep by manually or mechanically for removal the same outside MD land complete all as specified and directed.
Removal of blockage in sewage line from WC / floor trap to first manholes, gully trap, etc with sectional / flexible rod or steel or bamboo or through mechanical sewage cleaning apparatus and finally washing with fresh water complete all as specified and directed.
Cleaning of manhole of size 600mm to 1000mm depth by bailing out water taking out sludge & removing the sludge out side M.D land complete all as specified and directed.
All as per Item No. 40.00 above, but for manhole of size 1000 to 2000 mm depth complete all as specified and directed.
All as per Item No. 40.00 above, but for manhole of size 2000 to 3000 mm depth complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in drain cover manholes cover, cover slab for soakage well / and similar works supported on walls and set in cement mortar 1:4 including necessary form work complete all as specified and as directed by Engr in charge.
M&L TMT bars 6 to 8 mm dia, cut to length ,bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L TMT bars 10 mm dia and over, cut to length ,bent to shape required including cranking bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
Cleaning of sewage line of stoneware pipe and RCC pipe between two consecutive manholes or gully trap to manhole by rodding and flushing water in line after rodding to clean the line for 150mm dia pipe complete all as specified and directed.
All as per Item No. 47 above, but for 200 mm bore pipe complete.
All as per Item No. 47 above, but for 250 mm bore pipe complete.
All as per Item No. 47 above, but for 300 mm bore pipe complete.
S&F in repair FRP manhole covers, frame and gratings having any shape, area exceeding 0.20 Sqm but not exceeding 0.50 Sqm for manhole covers and installed as per manufacturer instruction. The top layer of covers, frames, and gratings consists of quartz and conundrum crystals, bonded with special grade of UV stabilised resin to get good abrasin resistance. The fibre glass shall be reinforced with glass fibre in the film of UD stitched, multidirectional wooden roving to get good tensile and flexural strength and embedded in the matrix of UV stabilised and high tensile stregth modified especially to suit this application. The frame shall be embedded in mimimum M-25 grade concrete and top level of frame should match with fixed surface etc complete all as specified and directed by Engr-in-Charge.
Cleaning of sewage line for 150 mm dia pipe by suction cum sewer jetting machine by pressurised water which can cut through grease, dirt, sand and roots and by the jetter nozzle which breakup the tough blockages and flush them out complete by removing stubborn clogs complete all as specified and directed by Engr In Charge.
All as per Item No. 52 above, but for 200 mm dia pipe complete.
All as per Item No. 52 above, but for 250 mm dia pipe complete.
All as per Item No. 52 above, but for 300 mm dia pipe complete.
Taking down rainwater/drain pipes/cast iron pipe (any size or pattern) including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories complete all as specified and directed in high rise building.
S&F PVC (SWR) pipes exc 160 mm dia & n.exc 200 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement, fixed to walls with clamp including high rise building including clamps and bends with couplers and all necessary fittings complete all as specified and as directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , fixed to walls with clamp in high rise building complete all as specified and as directed.
S&F PVC 110/100mm bore (SWR) coupler complete all as specified and directed.
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement , laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bends 110 mm dia complete all as specified and directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement, fixed to walls with clamp in high rise building complete all as specified and as directed.
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length, with rubber ring joints jointed with solvent cement, laid in trenches or in floors complete all as specified and as directed.
S&F PVC (SWR) bends 75mm dia complete all as specified and directed.
S&F PVC 75mm dia PVC (SWR) coupler complete all as specified and directed.
S&F in repair 450 mm long PVC connections 15 mm size with PTMT nuts at both ends complete all as specified and directed.
S&F in repair 32 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2, fixed as in spout pipe and making good disturbed surface in CM 1:3 complete all as specified and directed by Engr-in-Charge.
S & F in repair grating round/square 150 mm size of PTMT (minimum weight 100gms) complete all as specified and directed.
S&F in repair Salt glazed stoneware gully traps square or round mouthed of size 125mm x 110mm, complete all as specified and directed.
S&F in repair PVC (SWR) Nahani trap 75mm bore with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F in repair Cast iron Nahani trap/floor trap 75mm bore with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S&F in repair 75mm bore Cast iron spun pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floor complete all as specified and directed.
S&F in repair 75mm bore Cast iron spun pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall complete all as specified and directed.
S&F in repair Cast iron branch pieces single equal unequal suitable for 75 mm bore pipes with cement joint, ISI marked, complete all as specified.
S & F in repair Cast iron bends (any radius) with duck's heel rest with oval access door suitable for 75 mm bore pipes, with cement joints, ISI marked, complete all as specified and directed.
S&F in repair 100 mm bore Cast iron spun pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floor complete all as specified and directed.
S&F in repair 100 mm bore Cast iron spun pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, but fixed to walls complete all as specified and directed.
S&F in repair 100 mm bore Cast iron pipe Sockets (double) collars complete all as specified and directed.
S&F in repair Cast iron branch pieces single equal unequal suitable for 100 mm bore pipes with cement joint, ISI marked, complete all as specified and directed.
S&F in repair 100mm bore Cast iron cowls complete all as specified and directed.
S&F in repair 75mm bore Cast iron cowls complete all as specified and directed.
S&F in repair for 75 mm bore Cast iron spun pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, but fixed to walls complete all as specified and directed.
M&L for Providing precast cement concrete (type B-0, 1:2:4 using 12.5mm graded aggregate) louvers and jallies, 25mm thick (measured solid), including all mouldings and taking down old louvers and jallies, set in cement mortar 1:4, complete all as specified and directed.
M&L for Form work to sides and soffits of floor or roof beams, lintels, cantilevers etc complete all as specified and directed by Engineer-in-Charge.
M&L for RCC nominal mix using 20 mm aggregates in beams, cantilevers, lintels over 1.5 M span complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface of wall/louvers and jallies and applying two coats of cement based paint over after application of cement base wall care putty complete all as specified and directed.
M&L in repair for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 grade-165 complete all as specified and directed.
S&F in repair steel work in tubular trusses, purlins including special shaped washer etc complete using ERW or induction butt welded suare or round tubes conforming to IS 1161-1979 grade St- 240 complete all as specified and directed .
M&L preparation of new surface or previously untreated surface and applying two coats of synthetic enemel paints on steel Surfaces exc 10cm girth over a coat of red oxide primer complete all as specified and directed.
S&F in repair for Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F in repair 2mm thick fibre glass reinforced translucent corrugated/plain sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed.
Demolition of stone slabs and tiles of any description, laid bedded and pointed in any mortar complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Granite stone slab 20 mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in coloured cement (1:2) using marble dust with admixture of pigment to match with granite shade, laid over and including 15 mm thick cement screed bed in CM 1:6 complete all as specified and directed.
Labour only for moulding to granite/kota stone in to bracket straight or circle to facing of squared granite of any description complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for 25 mm thick plain cement concrete (1:2:4) type B0 (using 12.5 mm graded stone aggregates) as in flooring in leveling course, finishing cement concrete surface even and smooth without using extra cement complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. laid over and including 20 mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
M&L for light shade colour vitrified ceramic tiles 10mm thick (square/ rectangular) polished, area of each tiles n. exc 0.36 sqm in floors etc laid over and including 20 mm thick screed bed or bedding layer in CM (1:6), set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by Engineer-in-Charge.
M&L for joint free (edge cut) coloured glazed ceramic tiles 7 mm to 8 mm thick (square/ rectangular) polished area of each tile exc 0.06 Sqm but n. exc 0.18 sqm as in skirting/ dado etc laid over and including 10 mm thick backing coat in cement mortar (1:4), set and jointed in neat cement slurry and pointed with coloured cement to match the tiles complete all as specified and as directed by Engineer-in-Charge.
S & F in repairs rimless wall hung EWC with UF soft close seat cover with hinges and accessories set of size 390 x 570 x 365 mm complete all as specified and directed. Make: Jaquar Cat No:VGS WHT 81953 UF or equivalent as approved by GE.
Supply and fix in repairs single piece concealed cistern body (front or top actuation) with floor mounting frame, installation kit and p type drain pipe connection set for wall hung WC , fixed in position and connecting complete all as specified and directed. Make: Jaquar Cat No:JCS-WHT-2431FP or equivalent as approved by GE.
S & F in repairs Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc including flushing cistern & flush pipe) complete all as specified and directed.
S&F in repairs plastic sheet covers of any colour for water closet, closed pattern with flat bottom with mild steel chromium plated or alluminised hinging device complete all as specified and directed by Engr-in-Charge.
S & F in repair vitreous china wash down water closet pan (anglo Indian pedastal pattern ) p or s type (excluding flushing cistern ) complete all as specified and directed.
S&F in repairs vitreous china squatting pan, Orissa pattern of size 580x440mm, white with integral foot rest including connection to trap and flushing pipe complete all as specified and directed.
S&F in repairs white Vitreous china wash down water closet (pedestal pattern) with fixing bolt, Plastic water closet seat cover, white, closed pattern with flat bottom, and cover with aluminised hinging device, brass chromium plated Jet shower with one meter long flexible pipe including all connection complete all as specified and directed.
S & F in repairs Vitreous China Urinal, full stall type, white (excluding flushing cistern and waste pipe) complete all as specified and directed.
S&F in repairs 10 litres capacity PVC valveless symphonic action type, flushing cistern, low level, white, with inlet, ball valve float handle including brackets complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings n exc 15 cm thickness of any description and in any position not otherwise specifically provided for below or above ground level, including removal of debries to a distance exc 1.5 Km but n. exc 2 Km complete all as specified and directed.
M & L for Hardcore of gauge n exc. 63 mm, broken stone or boulders deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface with 8 to 10 ton roller compacted complete all as specified and directed by Engr in Charge.
M & L for Cement concrete in foundations, filling and mass concrete,Type D-2, 1:4:8 (40mm graded ggregate) complete all as specified and directed.
M&L for 25 mm sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M & L for Machine pressed precast concrete interlocking paver block of approved shape without correctin factor for chamfering , made in rubber moulds with 0.5mm thick scratch proof lacquer coating on top surface , with white cement and pigment laid over , confirming to IS 15658-2006 complete all as specified and directed (a) size 60mm thickness, with minimum compressive strength of 35 N/Sqmm (M-35 Grade)
All as per item No 115 here in before but size 80mm thickness, with minimum compressive strength of 40 N/Sqmm (M-40 Grade).
M&L for chequered cement concrete tiles of size 20cm x 20cm x 25mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed.
M&L for outdoor coloured heavy duty paving tiles/ rubber moulded digital chequered tile joint free edge cut of size 30cmx30cm of 15-20 mm thick,set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick screed bed or bedding layer in cement mortar 1:6 complete to match the tiles complete all as specified and directed by Engr-in-Charge.
Material & Labour for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making rainage opening wherever required complete all as specified and directed by Engr-in-Charge.
M&L for preparation of washing, rubbing down and scrapping of old surfaces of wall and applying one coat of acrylic emulsion (weather coat) paint using roller brush etc complete all as specified and directed by Engr-in-Charge.
M&L for preparation of new surfaces of wall and applying two coats of acrylic emulsion (weather coat) paint using roller brush etc including priming coat of exterior primer complete all as specified and directed by Engr-in-Charge.
S & F in repair for Pipe Supporting Clamping - Single Pipe of dia 110/100 mm down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm : Pipe Support Clamping made of : 1. Profile Bracket having Wall Distance 75 mm made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted "C" Channel with ribs to be used of size 250 mm (10") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10") - 1 No.; 3. U Bolt Rubber sleeve mounted for 110 mm (4") CI or PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Airforce Gandhinagar Zone Technical Drawing of Factory Made Pipe Supporting System : CEAG/AR/TD/08R.
S & F in repair for Pipe Supporting Clamping - Single Pipe of dia 75 mm down take pipe fixing done with Clamping System consists of Profile Bracket + Continuous Slotted C Channel + U Bolt Rubber Sleeve mounted System running vertically with wall distance 75 mm: Pipe Support Clamping made of : 1. Profile Bracket having Wall Distance 75 mm made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079); material size 32 mm x 3 mm with ribs and notch are Hot Dip Galvanzied + Zn Al Flake coated having Salt Spray Test (Test method - ASTM B-117-2019) result 2000 hrs with SS304 Hex Flange Bolt with Serration 5/16 x 3/4 (A/F 13mm) as per DIN 6921and SS304 Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration as per DIN 6923. 2. Continuous Slotted "C" Channel with ribs to be used of size 250 mm (10") made of Low Carbon Hot Roll Gauge Corrected Oil Pickled and Drawn (HROP D) Steel (IS 1079) are Hot Dip Galvanzied + Zn Al Flake coated with material thickness of 3mm. 3. U bolt Rubber Sleeve mounted are made of low carbon mild steel with Rod diameter 7 mm approx.; Zn Al Flake coated with noise absorbing semi transparent ribbed silicon rubber sleeve; with Hex Flange Nut BSW 5/16 x 18 x 8 x 13 with Serration set as per DIN 6923 - Zn Al Flake coated. Hotdip Galvanizing: As per IS 2629 (1985) - 610 grams/m2 (> 85 microns). Material Grade : IS 1079 used as per MTC confirms to EN 10204 3.1. Material Qty. for one unit : 1. Profile Bracket Wall distance 75 mm (3") - 2 Nos. 2. Continuous Slotted C Channel of Size 250 mm (10") - 1 No.; 3. U Bolt Rubber sleeve mounted for 110 mm (4") CI or PVC Pipe Dia. - 1 No.; and 4. Fixing Nail Zn coated of thickness 6.5 mm and length 63 mm (2 1/2") - 4 nos. Fixing Details: Pipe Support Clamping Unit to be fixed at every metre distance in the duct as specified in Chief Engineer Airforce Gandhinagar Zone Technical Drawing of Factory Made Pipe Supporting System : CEAG/AR/TD/08R.
Shree Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
Tender Document • 0.40 MB
Tenderdocuments8155.pdf
Tender Document • 0.94 MB
BOQ_733861.xls
BOQ • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .