Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.1 L+₹3.4 L (13.2%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L2 | Rejected-Finance L2 | |
| 3 | L3₹30.7 L+₹5.0 L (19.4%)Rejected-Finance 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹56,000
Closing Date
14 Jul 2025, 3:00 pmClosed
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
SITC of VRF Air Conditioning system at entire 2nd floor and the Law section at 4th floor APC Bhavan the Administrative Building of WBBPE at Salt Lake- SITC of VRF AC system
2025_WBPWD_866890_1
WBPWD/EE/BED/e-NIQ-35/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
APC Bhavan
Please refer Tender documents.
5 documents required · 5 mandatory
₹56,000
Room No. 108, Purta Bhawan, Salt Lake
13 Oct 2025
20 Jun 2025
16 Jul 2025
21 Jun 2025
14 Jul 2025
25 Jun 2025
24 Jun 2025
Amount
Supply, Installation, Testing & Commissioning of Air cooled VRF/VRV top discharge type Outdoor Unit each comprising of variable speed all inverter controlled scroll/rotary compressor, air cooled copper condensor with protective coated fins, mounting frame, micro processor control panel and other standard accessories according to OEM standard. The unit shall be suitable for operation with R-410A refrigerant. Minimum EER at 100% load & at minimum 35 degree centigrade ambient condition should not be less than 10 (Ashree standard table 6.8.1 L). Nominal capacity of outdoor units in BOQ at climatic condition of Kolkata taking into considertion of ambient corretion factor as per OEM standard to deliver inside temperature condition @22 ± 2 degree centigrade. The outdoor unit should either be a single module or combination of mutiple modules and each of the module should contain multiple variable speed inveter type scroll or rotary compressors. The rate is inclusive of anti vibration foot pad, Y conectors at ODU side if any. (Make : Mitsubishi Electric/Mitsubishi Heavy/O-General/Daikin). as per choice of EIC. 44 HP (12+14+18HP) Do---Do----Do 12 HP
Do---Do----Do 14 HP
Do---Do----Do 18 HP
Supply, Installation, Testing & Commissioning of VRF/VRV Indoor Units & accessories: (Make: Mitsubishi Electric/Mitsubishi Heavy/O-General/Daikin the make of VRF/VRV) as per choice of EIC. 3.6 KW cooling capacity indoor unit in 4-Way Compact Cassette type with 335 CFM or better with minimum three steps speed regulator, with chordless remote and noise level less than 36 db.
4.5 KW cooling capacity indoor unit in 4-Way Compact Cassette type with 388 CFM or better with minimum three steps speed regulator, with chordless remote and noise level less than 36 db.
5.6 KW cooling capacity indoor unit in 4-Way Compact Cassette type with 459 CFM or better with minimum three steps speed regulator, with chordless remote and noise level less than 36 db.
7.1 KW cooling capacity indoor unit in 4-Way STD. Cassette type with 671 CFM or better with minimum three steps speed regulator, with chordless remote and noise level less than 36 db.
11.2 KW cooling capacity indoor unit in 4-Way STD. Cassette type with 1024 CFM or better with minimum three steps speed regulator, with chordless remote and noise level less than 36 db.
14.0 KW cooling capacity indoor unit in 4-Way STD. Cassette type with 1235 CFM or better with minimum three steps speed regulator, with chordless remote and noise level less than 36 db.
Supply, Installation, Testing & Commissioning of Refrigerant copper "T" Joints with copper brezzing with nitrile rubber insulation of adequate thickness.
SITC of the of following nominal size of soft/ hard drawn copper refrigerent piping System including vaccumiazation and Nitrogen of testing for VRF/VRV AC system, complete with fittings, with adjustable ring type hanger supports, jointing/ brazing including accessories as required at site & approved by EIC, duly insulated with XLPE class -O tubular closed cell elastomeric nitrile rubber insulation (Make : Armacell/ K-flex/ Aeroflex/ A-flex) of 13mm thickness upto 15.9 mm OD Cu pipe & above 19mm thick insulation for higher sizes Cu pipes. Do---Do----Do Ф41.3 MM(17 SWG or 1.43mm)
Do---Do----Do Ф38.1 MM(17.5 SWG or 1.3 mm)
Do---Do----Do Ф31.8 MM(18.5 SWG or 1.1 mm)
Do---Do----Do Ф28.6 MM(19 SWG or 1 mm)
Do---Do----Do Ф22.2 MM(19 SWG or 1 mm)
Do---Do----Do Ф19.05 MM(19 SWG or 1 mm)
Do---Do----Do Ф15.9 MM(19 SWG or 1 mm)
Do---Do----Do Ф12.7 MM(21 SWG or 0.8 mm)
Do---Do----Do Ф9.53 MM(21 SWG or 0.8 mm)
Do---Do----Do Ф6.35 MM(21 SWG or 0.8 mm)
Supply & laying/ fixing of control cum transmission wiring with 3 core 1.5 Sqmm PVC insulated and sheathed copper conductor cable (Make : Havells/ Polycab/ Gloster/ RR Kabel/ KEI) through 20mm dia FR type PVC rigid conduits on existing cable tray / on wall as necessary (Make : Precision/ Polycab/Std. Make) for interconnection between IDUs & ODUs and IDUs and Remotes (if requires).
Supply and Laying of Rigid PVC Drain Pipe (Medium Class)with respective fittings ,proper supports at 5 feet interval and duly insulated with 6 mm thick closed cell nitrile rubber insulation. (Make : Oriplast/ Supreme/ Filolex/ Ashirbad/ Astral) Do---Do---Do 25 mm dia
Do---Do---Do 32 mm dia
Supply and Pouring of R410A refrigerant gas for entire system including Testing and commissioning of complete VRF/VRV system including all indoor units,outdoor units,electricals,remotes etc including pressure testing with nitrogen & vaccumasation.
Supply & fixing of 415V 63 Amp 4 Pole RCCB with 300mA [Make -Legrand/ Siemens/ ABB/ L&T] Sensitivity, for VRF/VRV Outdoor Units with suitable size & water proof IP65 GI prefabricated encloser box with rubber gasket.
Supply, errection & installation of fabricated MS Structure comprised of C'section Beam for foundation legs, 'C' channel structure, 6 mm chequered plate for platform suitable for mounting Outdoor unit including painting by anti-corrosive paint over RO primer, as per direction of EIC.
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. Do--Do--Do 150x50x1.25mm (18SWG) (With out angle iron support) as per GS.
Do---Do---Do 300x50x1.25mm (18SWG) (With 25x25x3mm angle iron support) as per GS.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
NATIONAL AIRCON (BID ID -6700443)
S.R. REFRIGERATION AND APPLIANCES (BID ID -6722195)
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .