Loading…
Loading…
Tender Value
₹18.8 L
EMD Value
₹47,100
Closing Date
5 Sept 2026, 3:00 pm
Chief Engineer, TTD, Tirupati
D.E(Elec)-II, Room No.128, TTD Admn. Bldg., Tirupati
Annual Comprehensive maintenance of centralized Air-conditioning units (141TR x 2 Nos) of Blue Star Make at Dialysis Block, SVIMS Hospital, Tiruapti for three (3) years 2026-27 to 2028-29
978602
348/DE(Elec)-II/TTD/TPT/2026-27
OPEN - NCB
Electrical Works
CHITTOOR, ANDHRA PRADESH
6 documents required · 6 mandatory
₹667
₹47,100
20 Aug 2026
20 Aug 2026
20 Aug 2026
Annual Maintenance following model centralized A.C Plant(Blue Star) located in SVIMS,Tiruapti for the year 2026-29
For the year 2026-27
For the year 2027-28
For the year 2028-29
Specifications: Make: Blue Star. Model: (i) LCAX1-0495DA ( Sl # 101771A– G16) 1 No. (ii) LCAX1-0495DA ( Sl # 101771B– G16) 1 No. Capacity: 141 TR X 2 Nos = 282TR Packaged chillers/ condensing unit/ packaged units with accessories like condenser/ chilled water pumps/cooling tower fans including/excluding air handling units, blowers will be operated daily.
Scope of work: To undertake service & Repair the plant for three years during normal working hours by carring out. a). Keeping all equipment externally cleaned. b). Checking water level and float valve operations in cooling tower, make up water and expansion tank, check compressor oil level wherever applicable. c). Checking all the rotating machines for smoothness of drive, vibration and noise level. d). Checking and adjusting belt tension of all V belt drives, if required e). Checking of starters for smooth operation. Monthly checks and service include: a). Subject to making the equipment available to blue star for checks and services, the following will be carried out. b). All bearings will be checked and lubricated if required. c). Alignment of driven machine with driving machine will be checked and rectified if required. d). Evaporator coils will be inspected and cleaned with compressed air or water if required, subject to availability of such medium for the purpose of cleaning at site. The cleaning medium shall be made available by the customer. e). Refrigeration piping and shaft seal wherever applicable will be inspected for signs of external leaks. f). Checking gland leakages of the pump valves. Note : Service reports of AC units must be sent to ; the O/o Divisional Engineer (Elec) - II and concerned Dy.Exe.Engineer (Elec) - SBH&AE/AEE(Elec) soon after each service.
(Rupees Eighteen Lakh Eighty Three Thousand Five Hundred thirty and Paise Thirty Nine only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
NIT 348.docx
TENDER_DOCUMENT • 0.17 MB
Schedule 348.xls
TENDER_DOCUMENT • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].