Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹13.3 L+₹71,500 (5.67%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹14.0 L+₹1.4 L (11.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹14.2 L+₹1.6 L (12.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹16.2 L+₹3.6 L (28.8%)Rejected-Finance 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | Vishav Karma Refrigeration and Electric Work L4 | M/S PRAJAPATI ENGINEERS L3 | M/S AKHILESHWAR ASSOCIATES L1 | VIRAT CONSTRUCTIONS L5 | M/S PYRAMID CONSTRUCTIONS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Opening up of existing water cooler for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning the tank, and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed.
Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item | 20 | Each Job | 99 ₹1,980 | 500 ₹10,000 | 50 ₹1,000 Lowest | 200 ₹4,000 | 465 ₹9,300 |
| 2.00 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit(Compressor) with new hermatic sealed unit, for water cooler of 40 liters capacity, complete all as specified and as directed | 4 | Each Job | 2,999 ₹11,996 | 4,000 ₹16,000 | 2,800 ₹11,200 Lowest | 8,500 ₹34,000 | 3,295 ₹13,180 |
| 3.00 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hematic sealed unit, for water cooler of 80 liters capacity, complete all as specified and as directed | 3 | Each Job | 5,999 ₹17,997 | 4,000 ₹12,000 Lowest | 4,000 ₹12,000 Lowest | 8,500 ₹25,500 | 4,265 ₹12,795 |
| 4.00 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hermatic sealed unit, for water cooler of 120 liters capacity, complete all as specified and as directed | 2 | Each Job | 7,999 ₹15,998 | 5,000 ₹10,000 | 4,500 ₹9,000 Lowest | 10,500 ₹21,000 | 7,659 ₹15,318 |
| 5.00 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for water cooler of 150 liters capacity, complete all as specified and as directed | 3 | Each Job | 7,999 ₹23,997 | 5,000 ₹15,000 | 4,500 ₹13,500 Lowest | 11,500 ₹34,500 | 7,895 ₹23,685 |
| 6.00 | M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for water cooler of up to 80 liters capacity including testing against any leakage, complete all as specified and as directed | 18 | Each Job | 699 ₹12,582 | 800 ₹14,400 | 600 ₹10,800 Lowest | 1,500 ₹27,000 | 679 ₹12,222 |
| 7.00 | All as per serial item No-6 above but for water cooler of 120 liters capacity. | 8 | Each Job | 999 ₹7,992 | 800 ₹6,400 Lowest | 900 ₹7,200 | 1,500 ₹12,000 | 1,225 ₹9,800 |
| 8.00 | All as per serial item No-6 above but for water cooler of 150 liters capacity. | 12 | Each Job | 999 ₹11,988 | 800 ₹9,600 Lowest | 900 ₹10,800 | 1,500 ₹18,000 | 1,285 ₹15,420 |
| 9.00 | M and L for Replacement of old unserviceable condensing coil of water cooler for 40 to 150 lts of capacity complete all as specified and directed | 6 | Each | 999 ₹5,994 | 800 ₹4,800 | 200 ₹1,200 Lowest | 1,500 ₹9,000 | 465 ₹2,790 |
| 10.00 | M and L for Replacement of old unserviceable/ damaged starting relay with new starting relay for water cooler of 40, 60 120 and 150 liters capacity, complete all as specified and as directed | 10 | Each | 249 ₹2,490 | 800 ₹8,000 | 150 ₹1,500 | 150 ₹1,500 | 118 ₹1,180 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Apr 2026, 6:00 pmClosed
GE SAMBA
GE SAMBA PIN 184121
REPAIRS AND MAINT TO DESERT COOLERS AIR CONDITIONERS AND REFRIGERATORS LAUNDRY PLANT AND CONNECTED ACCESSORIES OF ALL UNITS UNDER GE SAMBA
2026_MES_759345_1
8166/GE/SMB/T-09/2026-27
Open Tender
Miscellaneous Works
Item Rate
180 days
GE SAMBA
Class E Cat b i
8 documents required · 8 mandatory
₹500
GE SAMBA
₹40,000
Yes
18 Jul 2026
7 Apr 2026
30 Apr 2026
7 Apr 2026
28 Apr 2026
21 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Opening up of existing water cooler for Inspection by MES rep to ascertain due repair/replacement , of any size any type, at the site/ fixed in position and incl cleaning the tank, and testing after required repair /replacement including making necessary connection to the power point complete all as specified and as directed.
Notes (i) Repair / Replacement of old defective spare parts/ items shall be measured and paid separately under respective items.if orederd by MES Rep (ii) Cost of transportation of water cooler/ spare parts of water cooler required being repair/replaced, from site to workshop for repair and workshop to site after repair shall be deemed to be included in quoted rates of respective item | 20 | Each Job | 100 | ₹2,000 |
| 2 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit(Compressor) with new hermatic sealed unit, for water cooler of 40 liters capacity, complete all as specified and as directed | 4 | Each Job | 100 | ₹400 |
| 3 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hematic sealed unit, for water cooler of 80 liters capacity, complete all as specified and as directed | 3 | Each Job | 100 | ₹300 |
| 4 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit (Compressor)with new hermatic sealed unit, for water cooler of 120 liters capacity, complete all as specified and as directed | 2 | Each Job | 100 | ₹200 |
| 5 | M and L for Replacement of old unserviceable/ damaged hermatic sealed unit with new hermatic sealed unit (Compressor), for water cooler of 150 liters capacity, complete all as specified and as directed | 3 | Each Job | 100 | ₹300 |
| 6 | M and L for Replacement/ filling of refrigerant gas (R-134a), suitable for water cooler of up to 80 liters capacity including testing against any leakage, complete all as specified and as directed | 18 | Each Job | 100 | ₹1,800 |
| 7 | All as per serial item No-6 above but for water cooler of 120 liters capacity. | 8 | Each Job | 100 | ₹800 |
| 8 | All as per serial item No-6 above but for water cooler of 150 liters capacity. | 12 | Each Job | 100 | ₹1,200 |
| 9 | M and L for Replacement of old unserviceable condensing coil of water cooler for 40 to 150 lts of capacity complete all as specified and directed | 6 | Each | 100 | ₹600 |
| 10 | M and L for Replacement of old unserviceable/ damaged starting relay with new starting relay for water cooler of 40, 60 120 and 150 liters capacity, complete all as specified and as directed | 10 | Each | 100 | ₹1,000 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
BOQ_850535.xls
BOQ • 1.37 MB
TenderDocuments09.pdf
Tender Documents • 0.67 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .