| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAccepted-AOC DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹30.1 L+₹1.5 L (5.33%)Rejected-Finance D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹40.7 L+₹12.1 L (42.1%)Rejected-Finance D NO 37 8 1 MANCHUKONDA GARDENS INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L3 | Rejected-Finance Being not L1 |
Tender Value
₹47.5 L
EMD Value
₹95,000
Closing Date
14 Oct 2022, 6:00 pmClosed
Garrison Engineer Utility-I
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR/MAINTENANCE OF CENTRAL AC PLANTS, PACKAGE UNITS AT MWC, TPW, NOIC UNDER AGE E/M - I OF GE(U-I) VISAKHAPATNAM
2022_MES_552432_1
8465/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-I
₹95,000
Yes
27 Oct 2022
16 Sept 2022
15 Oct 2022
16 Sept 2022
14 Oct 2022
1 Oct 2022
Amount
M & L for de-scaling the shells and tube of condenser unit by circulating the diluted hydrochloric acid at the appropriate ratio depending upon the scale deposits till removal of all the scale inside the copper tubes after removal of the both end covers, brushing with nylon/GI wire brush, removal of all scale deposits and degreasing with caustic soda, flushing out thoroughly, re-fixing the end covers with new gasket packing, nut and bolts and connecting the inlet and out let, every six month or as directed by engr-in-charge all as specified and directed.
2x80 TR + 1x80 TR AC plant at TPW Bldg 551/552 Bldg
2x140 TR + 1x140 TR AC plant at MWC Bldg
M&L for servicing and cleaning the Air handling units 35324 CFM capacity (central AC), with and including dismantling filter units, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, greasing of blower motor, checking of electrical connection, cleaning of air filters, greasing of blower motor, replacement of un serviceable bearings, cleaning water drain lines, renewal of rusted sheet metal screws, every month for running AC plant at optimal condition unit all as specified and as directed by Engineer-in-Charge.
All as per Item No.2 herein before but Air handling units 34400 CFM capacity
M&L for complete leak testing the compressor refrigerant pipe with Nitrogen gas, locating the leaks, rectify the leak by brazing/ welding and pressure testing the complete system for 10 TR to 240 TR capacity of AC plant of any type all as specified and as directed by Engineer-in-Charge.
Supply and replace in repair " V "belts for Air handling units 34400 CFM Make : Fenner/Dunlop or equivalent
All as per Item No.5 herein before but Air handling units 35324 CFM capacity
All as per Item No.5 herein before but Air handling units 35142 CFM capacity
All as per Item No.5 herein before but Air handling units 17050 CFM capacity
All as per Item No.5 herein before but Air handling units 48800 CFM capacity
All as per Item No.5 herein before but Air handling units 23000 CFM capacity
Supply and charge refrigerant gas F-22 all as directed by Engineer-in-Charge. Make: Mafron/ Freon/ Floron
Supply and charge refrigerant gas R-407C all as directed by Engineer-in-Charge. Make: Mafron/ Freon/ Floron
Supply and charge refrigerant gas R-134 all as directed by Engineer-in-Charge. Make: Mafron/ Freon/ Floron
M&L for taking down the defective unserviceable solenoid valve coil and supply & fixing of new solenoid valve coil suitable for 7/8” size valve, 220/230V 50 Hz all as directed by Engineer-in-Charge. Make: Danfoss/ Indfoss/Honeywell/Alco.
M & L for dismantling defective induction motor of any make 415 V of any duty or any class of insulation from the bed duly coupled with pump, transporting to work shop, removing burnt out winding from stator, rotor and rewinding with suitable gauge super enameled copper wire and replacing worn out driven end and non driven end bearings, insulation materials, varnishing, heating reassembling, testing and commissioning for the following capacities. Notes :- Motor removed for rewinding shall be overhauled completely and the quoted rate shall be deemed to be inclusive for the same.
M & L for replacement of unserviceable/ damaged power contactors in various AC plant panels and supply and fix the following power contactors complete including necessary control wiring all as directed. Make: L&T/ BCH/ C &S/ABB/Siemens/HPL
Control transformer unit 400 VA, 50 HZ,Contactor 3 pole
HRC semi conductor fuse unit 315 Amps of M/s Siemens, Contactor 3 pole
3TF45 11-0X 1No+1 NC of M/s Siemens,Contactor 3 pole
3TF48 11-0X 1No+1 NC of M/s Siemens,Contactor 3 pole
Supply and replace MCB 63 Amps, 3 pole, 415Volt, complete all as specified and as directed. Make: L&T/ BCH/ C &S/ABB/Siemens/HPL
Supply and replace MCB 32 Amps 2 pole, 415 Volt, complete all as specified and as directed. Make: L&T/ BCH/ C &S/ABB/Siemens/HPL
M & labour for cleaning and decarbonizing, AC panel, tightening all cable ending lugs, ferrules, dressing and replacing damaged,burnt cable/wire ends, replacing copper wires of suitable size , applying insulation tapes complete all as specified and as directed.
S & replace 32 Amps contactor with 1NO, 1 NC , 110 V - 290 V AC complete all as specified and as directed.
S & replace butterfly value 150mm dia with necessary rubber gasket, bolts, nuts and washer including taking out existing valve all as directed Make : Zoloto / Kirloskar/Leader/Audco/Sant
S & replace butterfly value 100mm dia with necessary rubber gasket, bolts, nuts and washer including taking out existing valve all as directed Make : Zoloto / Kirloskar/Leader/Audco/Sant
Supply only compressor oil of make Seathel No.68 / Servofreeze69 / Castrol
Supply and repalce/ top-up compressor oil SW 220 or equivalent for carrier/Voltas compressor.
M & L for Complete servicing of FRP cooling tower at site , removal of complete scales, dirt etc. by using chemicals, cleaning the sump louvers, PVC fills, fan assembly, renewal of spray nozzles, renewal of nuts and bolts, and complete painting of the cooling tower as per the standard practice for 3 x 100 TR capacity cooling tower all as specified at every three months and directed.
Complete servicing of FRP cooling tower, removal of complete scales, dirt etc. by using chemicals, cleaning the sump louvers, PVC fills, fan assembly, renewal of spray nozzles, renewal of nuts and bolts, and complete painting of the cooling tower as per the standard practice for 3 x140 TR capacity cooling tower at every three months all as specified and directed.
M & L for opening and taking out the compressor shaft at site and seal cleaning, greasing, replacing worn out nuts, screws, connector assembly all complete as specified and described.
Supply & replace in repair DOL Starter with relay range13-20 Amps suitable for 10/15 HP Motor with SPP feature . Make : L&T/ C&S/ABB/Siemens/HPL/BCH
Supply and repalce condenser fan motor, 1 HP capacity, 240V, 50Hz, 900 RPM complete all as directed.
M&L for overhauling of condeser water pump complete at site , replacement of bearing, machining the shaft, replacing the packing, electric connector, replacing worn out copper winding with new copper winding wire of suitable guage, varnishing and replacing other minor accesories 5 HP to 12.5 HP complete all as specified and directed.
S & replace of mother board for 3x16 TR VRF Plant of Bluestar Make all as specified and as directed by Engr-in Charge.
S & replace temparature censor cable suitable 140 TR chiller plant suitable for model Carrier 30 HXC complete all as directed.
S & replace HP switch 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace LP transucer 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace HP transucer 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace SCPM board 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace mother board 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace internal oil filters 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace 3TF47 siemens contactor 110 V AC 2x140 TR+1x140 TR water cooler central AC plant of make and model Carrier 30 HXC complete all as directed.
S & replace of Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 2000 Ltrs hoisted and fixed in position complete including taking down existing all as specified. Make : Sintex/Polycon/Ashish
S & replace of Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 Ltrs hoisted and fixed in position complete including taking down existing all as specified. Make : Sintex/Polycon/Ashish
M & L for Overhauling of split casing type pump up to 40 HP dismantling the pump carryout overhauling including replacing the complete damaged spare parts . Repair /replacing the wornout shaft ,replacing the bushes roller/ball bearings,wearing gland packages,renewal all corruded studs, gaskets, damaged impellars etc. Assembly watch good of alignemnt including testing and commissioning the pump all as directed and specified by Engr-in-Charge.
M&L for replacing the chocked drier core assembly inclduing removing the defective ,cleaning the core washing with CTC/dettol and fixing new core of activated alumina type corefixing the new gasket testing leak and testing for screw type chiller plant upto 140TR complete all as directed.
M&L for maintenance and repair of central control unit 3x16 TR VRF AC plant of Blue star make including dismantling the units carefully, chemical cleaning of cooling coils and refrigerant pipe lines with appropriate cleaning agents, flushing through for proper air flow across the coils to improve the cooling efficiency, reassembling & re-installing the units in their original position complete all as directed.
Supply, replace and testing of the following Spare Parts as required during repair of 3x16 TR VRF AC plant of Bluestar complete all as directed
Power board (CDCO-D182-00) 01 6480
VRF ODU FAN CONTROLLER (CDCO-D345-00) 01 7680
10HP Capacitor boards (CDCO-D338- 00) 1 18600
ODU fan motors (MOBLDC-008280-4- 00) 2 19800
16HP VRF outdoor unit main PCB board controller
Supply and charge R410 referigerant for VRF plant Make: Mafron/Frcon/Floron.
VRF 4 TR cassettle ac indoor units main PCB controller
VRF 2.8 TR casserttle ac indoor units main PCB controller
VRF 1.7 TR Split ac indoor units main PCB controller
VRF 1 TR split ac indoor units main PCB controller
VRF IDU coil sensors
VRFcasettle IDUdrain flot sensors
VRF IDU Room sensors
M & L for prepration of metal surface by scraping properly and removing burrs, uneven surface, apply a coat of primer and a coat of synthetic enamel paint complete all as specified and directed.
M & L for preparing old cement surface, removing dust, grease completely and apply cement based acrylic paint all complete all as specified and directed.
Supply and replace MS pipe heavy grade 150mm NB alongwith all flanges, fittings, nuts, bolts,accessories, all complete as specified and directed. Make : Surya roshini/Tata/Jindal/Prakash
Supply and replace MS pipe heavy grade 80mm NB alongwith all flanges, fittings, nuts, bolts,accessories, all complete as specified and directed. Make : Surya roshini/Tata/Jindal/Prakash
Supply and replace GI pipe medium grade 25mm NB alongwith all flanges, fittings, nuts, bolts,accessories all complete as specified and directed. Make : Surya roshini/Tata/Jindal/Prakash
S&replace butterfly value 75/80mm NB dia with necessary rubber gasket, bolts, nuts and washer including taking out existing valve all as directed Make : Zoloto / Kirloskar/Leader/Audco/Sant.
M & L for Removing the worn out duct insulation carefully , cleaning / preparing the surfaces and M&L for duct insulation (25mm thick) with resin bonded fibre glass wool roll of density 24 kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation as specified and including the following :- (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
Repair and servicing to screw type compressor strip opening complete spare parts of at TPW 551, 552 Bldg of AC plant capacity 2x80 TR+1x80 TR. Inspecting the parts for serviceability and replacement only unserviceable worn out parts in the compressor, complete assembling cleaning the system with Nitrongen gas for leak detection after flushing out the system vacuumization and charging only refrigerant gas including replacement of compressor oil of make as recommended by OEM and testing the unit on no load and full load condition including checking al the parameters etc complete all as directed. . Note : (i) Compressor oil including other minor spares which are not covered here in after shall be included in quoted rate. (ii) Spares required shall be measured and paid as Supply only as mentioned here-in-after. (iii) Periodical monitoring / Inspecting the complete AC Plant and carrying out preventive / periodical maintenance to ensure smooth functioning of AC plant. The periodical inspection for preventive maintenance shall be carried out by the authorised technician / service engineer of OEM. (iv) If any breakdown occurs for monitoring the operational condition of AC plant during the contract period shall be attended whenever required which is included in the rate quoted.
M & L for prepration of metal surface by scraping properly and removing burrs, eneven surface, apply a coat of primer and a coat of synthetic enamell paint on top of same colour as pervious for entire 2x80 TR+1x80 TR central AC plant, including, pipe lines, pumps motors, panel boards for ously applied all complete as specified and directed.
M & L for prepration of metal surface by scraping properly and removing burrs, eneven surface, apply a coat of primer and a coat of synthetic enamell paint on top of same colour as pervious for entire 2x140 TR+1x140 TR central AC plant, including, pipe lines, pumps motors, panel boards for ously applied all complete as specified and directed.
Supply and replace MCCB 3 pole 63 Amps, AC supply, 415 Volts, 50Hz, 26KA all complete as specified and directed. Make: L&T/ BCH/ C &S/ABB/Siemens/HPL
Supply and replace MCCB 3 pole 100 Amps, AC supply, 415 Volts, 50Hz, 26KA all complete as specified and directed. Make: L&T/ BCH/ C &S/ABB/Siemens/HPL
Supply and replace MCCB 4 pole 250 Amps, AC supply, 415 Volts, 50Hz, 26KA all complete as specified and directed. Make: L&T/ BCH/ C &S/ABB/Siemens/HPL
M&L for servicing and cleaning the Air handling units 48800 CFM capacity with and including dismantling filter units, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, greasing of blower motor, checking of electrical connection, cleaning of air filters, greasing of blower motor, replacement of un serviceable bearings, cleaning water drain lines, renewal of rusted sheet metal screws, every month for running AC plant at optimal condition unit all as specified and as directed by Engineer-in-Charge. Location : TPW 551 Bldg AHU 2nos x 48800 CFM, TPW 09 Bldg AHU 01 NO. AHU 48800CFM
M&L for servicing and cleaning the Air handling units 23000 CFM capacity (central AC), with and including dismantling filter units, blowing out the dust, chemical cleaning by spraying the organic based scale removing agent Vaniklin at the appropriate ratio till removal of complete dust & scale deposits in the fin area of evaporator coil, flushing through for proper air flow across the coil, greasing of blower motor, checking of electrical connection, cleaning of air filters, greasing of blower motor, replacement of un serviceable bearings, cleaning water drain lines, renewal of rusted sheet metal screws, every month for running AC plant at optimal condition unit all as specified and as directed by Engineer-in-Charge. Location : TPW 09 Bldg
Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric cable of 4 core 16 sqmm, 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
All as per item No.81 here-in- before but of 3.5 core 50 Sqmm.
All as per item No.81 here-in- before but of 3.5 core 120 Sqmm.
Supply and replacement of multi core PVC insulated stranded copper conductor of size 1.5 sqmm 3 core cable to be connected with street light fittings to loop-in and out boxes with its end point terminal connection all as specified and directed. Make : Polycab /Finolex / Havells/ KEL Industries/ RR kabel
Supply and replace aluminium bus bars 400 Apms rating for phase of length not less than 1 Mtr after disconnecting all electrical connections, and dismantling the old busbars from position all complete as specified and directed.
Supply and replace aluminium bus bars 300 Apms rating for neutral of length not less than 1 Mtr after disconnecting all electrical connections, and dismantling the old busbars from position all complete as specified and directed.
M & L for Removing old earth and M & L for earthing complete with GI earth plate electrode of size 600mm x600mmx 6.0 mm thick burried directly under ground vertically to a depth not less than 2.25 meter below ground level with top edge of the plate at a depth not less than 1.5 m below ground level connected to and including GI strip 32 x 6mm, by means of bolts, nuts, check nuts and washeres made out of GI including protection pipe GI light grade 40 mm size and watering pipe 20 mm dia GI medium grade all as shown on plate No 3 of SSR Part-I, connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed.
M&L earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as 32x6mm GI strip complete as directed
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety (size 2x1m) all as specified and directed by Engr-in-Charge ( MAKE:-PREMIERPOLYFILM Ltd/SUNTEX INSULATICA/DUNLOP).
Repair and servicing to semi hermetic sealed compressor of 2x140 TR+1x140 TR water cooled central AC plant at MWC bldg inclusive taking down and dismantling the complete compressor unit and including replacement of defective spare viz cylinder , piston heads, connecting rod, crank shafts, oil pump, bearings , valves, packing kit , o’ rings , reeds, etc. and Reassembling the same including cleaning and flushing out the system , the N2 gas for leakage proof and vaccuming and charging with suitable refrigerant gas and replacement of compressor oil of make as recommended by OEM and testing the unit on no load and full load condition including checking al the parameters etc complete all as directed. Note : (i) Compressor oil and refrigerant gas will be paid separately. Spare parts replaced will also be paid against items mentioned in the schedule here-in-after.
(ii) Spares required shall be measured and paid as Supply only as mentioned here-in-after. (iii) Periodical monitoring / Inspecting the complete AC Plant and carrying out preventive / periodical maintenance to ensure smooth functioning of AC plant. The periodical inspection for preventive maintenance shall be carried out by the authorised technician / service engineer of OEM. (iv) If any breakdown occurs for monitoring the operational condition of AC plant during the contract period shall be attended whenever required which is included in the rate quoted.
Supply only following spare parts
Supply only valve plates with reeds
Supply only connecting rod
Supply only piston with rings
Supply only bush Bearing set
Supply only oil pump with accessories
Supply only Crank shaft
Supply only Packing complete
Supply only Suction filter
Supply only Oil filter
Supplying, laying, testing and commissioning LT XLPE insulated , armoured heavy duty electric cable of 3.5 core 400 sqmm, 1100 volts grade with stranded aluminium conductor laid in trenches / passing through pipe / duct/ road crossing /fixed on poles / walls Complete all as specified and directed. MAKE: Havells / Gloster / KEI Industries Ltd / Polycab / Asian Cables / Finolex [Note: The rate quoted shall inclusive of termination at ends with suitable aluminium lugs where required]
Excavating in trenches n. exc. 1.5m wide and n. exc. 1.5m in depth for foundation, trenches for laying poles/ cables/ pipe line etc. and getting out in soft/loose soil complete all as specified and directed.
Removing excavated materials to a distance n. exc. 50 m and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed.
Returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as per SSR as specified and as directed. (Note: Punned thickness only shall be measured)
Supply and laying sub class 'B' bricks of old size (23x11x7cm) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-Charge
M/S CHANDRA ENGINEERS AND CONTRACTORS
KRISHNA ENGINEARING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .