Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹10.3 L+₹96,440 (10.4%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest bidder | |
| 3 | L3₹10.5 L+₹1.2 L (13.1%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest bidder |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
2 Dec 2019, 6:00 pmClosed
AGE(I) MES Dharamshala HP
AGE(I) MES Dharamshala HP
Provn of Toilet Block 06 WCs 02 Bathrooms 01 Geyser near Building No N-23 In Tirah Line at Mil Stn Dharamshala
2019_MES_292428_1
AGE(I)/DSL-36/2019-20
Open Tender
Civil Works
Item Rate
180 days
Military Station Dharamshala
As Per NIT
6 documents required · 6 mandatory
₹500
AGE(I) MES Dharamshala HP
₹19,000
Yes
17 Jan 2020
25 Oct 2019
4 Dec 2019
25 Oct 2019
2 Dec 2019
8 Nov 2019
Amount
Sch 'A' Part-I: Building work. Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out soft/ loose soil complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-10, type C-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete, including necessary formwork where required, complete all as specified and directed by the Engr-in-Charge.
RCC (nominal mix), M-15, type-B-1 (using 20mm graded crushed stone aggregates) as in beams, cantilevers, bressumers, lintels over 1.5 m spanand the like including necessary form work complete all as specified and directed by the Engr-in-Charge.
Returning, filling in, including spreading, levelling,watering and well ramming in layers n.exc 25 cm thick ,complete all as specified & directed by Engr-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point,complete all as specified & directed by Engr-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, pillars, posts, struts, piers, columns and stanchions, etc. complete all as specified & directed by Engr-in-Charge.
Brick work with sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete, all as specified and directed by the Engr-in-Charge.
15mm thick rendering in CM 1:4 on fair faces of brick wall or on concrete surfaces, surface finished even and smooth without using extra cement, complete all as specified and directed by Engr-in-Charge.
Rendering 10 mm thick on other than fair faces of brick or concrete surface in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge
Two coats of Exterior weather emulsion paint on walls including prepration of new plastered/ unplastered surfaces complete all as specified and directed by Engr-in-Charge.
Two coats of cement based paint on walls including prepration of new plastered surfaces complete all as specified and directed by Engr-in-Charge.
Spreading & levelling excavated earth under floors in layers not exceeding 25 cm thick and well ramming including watering complete all as specified and directed by Engr-in-Charge.
Hard Core of gauge 63mm, deposited, spread and levelled in layers not execeeding 15cm thick, watered and rammed to a true surfaces with broken stones, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, 100mm thick, M-15, type B-1, (using 20mm graded crushed stone aggregates) as in flooring and similar works finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
Plain cement concrete, 75mm thick, M-7.5 (nominal mix), type D-2, (using 40mm graded crushed stone aggregates) as in sub base finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
Plain cement concrete, 75mm thick, M-10 (nominal mix), type C-2, (using 40mm graded crushed stone aggregates) as in plinth protection and similar works finished even and smooth without using extra cement complete all as specified and directed by Engr-in- Charge.
Factory made solid panel PVC door frame of size 60x30mm, made out of 5mm prelaminated sheet instead of plain colour PVC sheet & edges will be painted to match with prelaminated sheet reinforced with MS square tube complete frame fixed with screws/nails/ bolts to walls complete all as spcified and directed by Engr-in-Charge.
Factory made PVC moulded door shutter with particle board core 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm moulded prelaminated PVC sheet on the front face & 2mm thick plain colour PVC sheet on back face complete all as spcified and directed by Engr-in-Charge.
Factory made solid panel PVC door shutter 30 mm thick (stile) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail,lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of wood grain printed PVC sheet used instead of Plain colour PVC sheet & 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900 ) used instead of exposed portion of PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing on page No. 156 of MES SSR Part-II 2010, complete all as specified and directed by Engr-in-charge.
Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking and binding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engr-in-Charge.
Mild steel TMT bars 8 mm dia and over, cut to length, bent to shape required including cranking and binding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by the Engr-in-Charge.
Vitreous chinaware squantting pan, ''Orrisa pattern'', size 580mm x 440mm white, with Cast iron 'P' or 'S' trap, front or back inlet, integral footrest excluding flushing cistern and flush type etc; and making good to floors, complete all as specified and directed by Engr-in-Charge.
PVC valveless, syphonic action type flushing cistern, crystal white, 10 ltr capacity, superior quality, plunger type, low level, with inlet, ball valve, float and handle, 32mm dia PVC long bend flush pipe 90cm long and 15mm dia 450 long PVC connection with CP brass coupling nuts and PVC washers at both ends complete all as specified and directed by Engr-in-Charge.
Viterous china wash hand basin, white flat back of size 550X400mm including cutting for and pining in ends of brackets including 15mm dia pillar tap, cast copper alloy with capstan head chromium plated screwed down high pressure with or without lettred hot or cold with long screw shanks and fly nuts srewed for iron pipe complete all as specified and directed by Engr-in-Charge.
PVC (SWR) pipe, 110mm bore, single socketed in any length with rubber ring joint, laid in trenches/ floor, complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) pipe 75mm bore single in any type with rubber fing joint fixed to walls complete all as specified and directed by Engr-in-Charge.
PVC (SWR) pipe, 75mm bore, single socketed in any length with rubber ring joint, laid in trenches/ floor, complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) bend any radius 110mm bore complete all as specified and directed by Engr-in-Charge.
PVC (SWR) reducers 75/110mm bore complete all as specified and directed by Engr-in-Charge.
PVC(SWR) vent cowl 75mm bore complete all as specified and directed by Engr-in-Charge.
PVC (SWR) 'S’ trap, 125 /110 mm bore, complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) bend, 75mm bore, any radius, provided with access door, complete all as specified and directed by the Engr-in-Charge.
PVC (SWR) junction single (single T), equal or unequal bend, 110mm bore , complete all as specified and directed by the Engr-in-Charge.
Grating doom 125mm dia PTMT(min wt 40gm) complete all as specified and directed by Engr-in-Charge.
PVC (SWR) gully trap 125/110mm bore setting and jointing with solvent cement complete all as specified and directed by Engr-in-Charge.
Bib taps, 15mm bore, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engr-in-Charge.
Angle stop valve, 15mm bore, cast copper alloy, screwed for iron pipe & fixed complete all as specified and directed by Engr-in- Charge.
PVC connection,15mm bore 600mm long, with PTMT nuts, complete all as specified and directed by Engr-in-Charge.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and 03 Nos railing in front & sides 60cm long complete all as spcified and directed by Engr-in-Charge.
CP towel rail 20mm dia, 600mm long, complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-15, type B-2 (using 40 mm graded crushed stone aggregate) as in surface channel and drain, complete all as specified and directed by Engr-In-Charge.
15mm bore GI tubing, medium grade, galvanised with all fittings and fixtures fixed to walls and celling or laid in floor, complete all as specified and directed by Engr-in- Charge.
20mm bore GI tubing, medium grade, galvanised with all fittings and fixtures fixed to walls and celling or laid in floor, complete all as specified and directed by Engr-in- Charge.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and directed by Engr-in-Charge.
3mm thick figured sheet glass, pin head type and glazing with oil putty in squares not exceeding 0.50 sq.m. in each pane, complete all as spcified and directed by Engr-in-Charge.
100mm butt hinge, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-Charge.
75 mm butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-Charge.
100mm aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
150mm long aluminium alloy handles, cast type, anodised complete all as specified and directed by Engr-in-Charge.
100mm long aluminium alloy handles, cast type, anodised complete all as specified and directed by Engr-in-Charge.
250mm long aluminium, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed complete, all as specified and directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank(cylinderical vertical with closed top) hoisted and fixed in position of capacity 1000 ltrs including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed with all fittings and fixtures, complete all as specified and as directed by Engr-in-Charge.
Stop valve, 20mm bore, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions suitable complete, fancy type, chromium plated, complete all as specified and directed by Engr-in-Charge.
Stop valve, 15mm bore, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions suitable complete, fancy type, chromium plated, complete all as specified and directed by Engr-in-Charge.
Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-42gms/20mm-210gms/25mm-455gms/40mm-690gms), complete all as specified and directed by Engr-in-Charge.
Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-7.5, type D-2 (using 40 mm graded crushed stone aggregates) as in foundation, filling and mass concrete complete all as specified and directed by the Engr-in-Charge.
Damp Proof course, 40mm thick, M-15 to horizontal or vertical surfaces including necessary form work complete all as specified and directed by the Engr-in-Charge.
Non skid (mat finish), ceramic coloured tiles, primium class-I grade, 7 to 8mm thick (square/rectangular), area of each tiles exc. 0.11 sqm but n.exc. 0.18 sqm in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15mm thick screed bed in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Glazed ceramic coloured tiles of size 300mmX200mm, thickness not less than 7mm thick as in vertical concrete /brick surfaces, set and jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
Galvanized corrugated mild steel sheeting, 0.63 mm thick with two corrugations side lap, fixed with ' L' or 'J' hooks and washers, as in roof covering with grade of zinc coating 275gm/ sqm, complete all as specified and directed by Engr-in-Charge.
PGI mild steel sheeting, 0.63 mm thick, as in ridges, valley, gutter etc., fixed with L-type or J type hooks and washers, complete all as specified and directed by Engr-in- Charge.
Mild steel work as in wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engr-in-Charge.
Rolled MS wk as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. of Fe-410W (Gde E-250) quality 'A' complete all as specified and directed by Engr-in-Charge.
Shower rose, 125mm Chromium plated, with or without swivel joints, any size, including fixing to steel pipe or union, fixed in repair complete all as specified and directed by Engr-in- Charge.
Pressed steel frame of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and directed by Engr-in-Charge.
Factory made 2nd Class hard wood (Sal/Hollock) 35mm thick Glazed and skeleton shutters , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.20 (a) ; supplied and fitted to chowkhats all as specified and as directed by the Engineer-in-Charge.
Mild steel wire cloth of 0.63 mm nominal dia of wire and average width of aperture 1.40mm fixed with tinned tacks, or galvanised wire staples in guazed steel windows all as specified and as directed by the Engineer-in-Charge.
Two coats of synthetic enamel paint over a coat of red oxide on new untreated steel surfaces of any description not otherwise described over 10 cm width or girth including preparation, complete all as specified and as directed by Engineer -in -Charge.
Two coats of synthetic enamel paint over a coat of pink primer on new untreated wooden surfaces of any description not otherwise described over 10 cm width or girth including preparation, complete all as specified and as directed by Engineer -in -Charge.
75mm bore PVC (SWR) floor trap with grating including jointing with solvent cement complete all as specified & directed by Engr-in-Charge.
Chequered cement concrete tiles maching pressed glossy finished (heavy duty) of size 300x300x30mm thick with grey cement and pigment set jointed & pointed in neat cement slurry in floors over 15mm thick screed bed in cement mortar 1:6 complete, all as specified and directed by Engr-in- Charge.
Plain cement concrete, 100mm thick, M-10 (nominal mix), type C-2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed by Engr-in-Charge.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out, complete all as specified and directed by Engr-in-charge.
Brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:6 complete, all as specified and directed by the Engr-in-Charge.
Sch 'A' Part-II: Protective work. Excavation over area not exceeding 1.5m deep & getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-5, type D-2 (using 40 mm graded crushed stone aggregates) as in foundation filling and mass concrete , including necessary formwork where required complete all as specified and directed by the Engr-in-Charge.
Walling of random rubble stone masonry, uncoursed, brought upto courses, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Plain cement concrete, M-15, nominal mix, type B-1, (using 40mm graded crushed stone aggregates), as in coping / benching and the similar works, etc. including necessary form work, complete all as specified and directed by the Engr-in-Charge.
TMT bar 10 mm dia and over, cut of length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
Hand packing ( any thickness ) of broken boulders or stones at back of walls over arches etc. and raising, complete all as specified and directed by Engr-in-Charge.
PVC (SWR) pipe, 110mm bore, pressure rating 4kg/sqcm, fixed in retainning wall, complete all as specified and directed by the Engr-in-Charge.
Plain cement concrete, M-15, nominal mix, type B-1 (using 20mm graded crushed stone aggregates), as in bond stone including necessary form work, complete all as specified and directed by the Engr-in-Charge.
Extra over stone walling for hammer dressing to face stone and dressing of face beds and joints of RR stone walling uncourse or brought up to courses with max depression on face from straight edge held against the dressed surface n. exc. 40 mm for granite or trap stone complete all as specified and directed by Engr-in- Charge.
Raised pointing to random rubble stone walling, uncoursed, built in CM 1:6 complete all as specified and directed by Engr-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point,complete all as specified & directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling,watering and well ramming in layers n.exc. 25 cm thick ,complete all as specified & directed by Engr-in-Charge.
Sch 'A' Part-III: Sewage Disposal. Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for pipe line or manholes not exceeding 10Sqm on plan & not exceeding 1.5m in depth and getting out in any type of soil complete all as specified and directed by Engr-in-Charge.
Concrete bed to drain pipes,150mm bore, in cement concrete M-10, type C-2 including packing under, and haunching against the sides of pipes after they are laid and tested complete all as directed by Engineer-in-Charge.
Reinforced concrete pipes, 150mm bore, Class NP2 , laid and jointed complete with collars, laid in trenches, complete all as specified and directed by the Engr-in-Charge.
Mild steel framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary , gussets plates, riveting , etc.; n exc 10 Kg each brackets, conforming to Fe-290 Gde E-165 ( Brackets over 10 Kg each to be measured under ' Structural Steel"), complete all as specified and directed by the Engr-in-Charge.
Precast RCC manhole cover slab, M-15, type-B-1 (using 20mm graded aggregates) set in CM 1:4, complete all as specified and directed by the Engr-in-Charge. (Note : Reinforcement shall be measured and paid separately).
Mild steel TMT bars 6 to 8 mm dia (Fe 500) and over, cut to length bend to shape required including cranking and binding with steel wire 0.9 mm dia annealed complete all as specified and directed by the Engr-in-Charge.
Returning, filling in, including spreading, levelling,watering and well ramming in layers n.exc 25 cm thick ,complete all as specified & directed by Engr-in-Charge.
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point,complete all as specified & directed by Engr-in-Charge.
Septic tank for 50 users, excavation in ordinary soil and complete all as shown on drawing No. CEPZ/C-TD/013/13, Sheet 1/5 to 5/5 & as directed by Engr-in-Charge.
Soakage well of size 1.20x3.00 mtr deep,excavation in ordinary soil and complete all as shown on drawing No. CEPZ/C-TD/013/13, Sheet 1/5 to 5/5 & as directed by Engr-in-Charge.
Sch 'A' Part-IV: Internal Electrification Works Point wiring with 1.5 Sqmm copper conductor (Multi-stranded) PVC insulated and unsheathed FRLS electric cable 1100 volts cable and including PVC conduite 20mm dia ISI marked (as per conductor run) with all fittings/ accessories totally concealed and including PVC insulated electric cable 1100 volts 1.5 Sqmm ( multi-stranded) copper conductor single core( Green colour) cable as continuous earth wire connected to common earth dolly including wooden box covered with 3 mm thick plastic laminated sheet for one light point/ fan/exhaust fan point/ bell point etc controlled by one, one way switch,complete all as specified and as directed by the Engineer-in-Charge. Make: Havells/Plaza/Polycab Note : (i) New Sunken boxes wherever required shall be measured & paid separately. (ii) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost. (iii) Electric rewiring should be followed by proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.
All as per serial item No 100 here-in-before, but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheathed electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Socket combination 2 in 1, 3 Pin 5 Amp and 15 Amp, flush type complete all as specified and as directed by the Engineer-in-Charge.
Switch piano, flush type, single pole, one way, 15 Amp, complete all as specified and as directed by the Engineer-in-Charge.
Switch piano, flush type, single pole, one way, 5 Amp, complete all as specified and as directed by the Engineer-in-Charge.
Ceiling rose, surface type, 65 mm x 50 mm, two to three terminals/ PVC/ polycarbonate, isolated body fixed on PVC block, complete all as specified and as directed by the Engineer-in-Charge.
Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar complete all specified and as directed by the Engineer-in-Charge. Note: (i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) The disturbed surface shall be match with existing surface. Make: Havells/Legrand/ABB
MCB SPN 40 Amp, breaking capacity 10KAcomplete all as specified and directed by the Engineer-in-Charge.
MCB SP 6-32 Amp breaking capacity 10KA complete all as specified and directed by the Engineer-in-Charge.
Energy efficient LED integrated batten, suitable for indoor applications tube light fitting 1x18 Watt 4 FT complete, Trim LED NEO including all fixing arrangement complete, all as specified and as directed by the Engr-in-Charage. Make: As per Wipro Cat Part No LL20-111-XXX-65-NE or equivalent in Philips/OSRAM.
Energy efficient LED integrated batten, suitable for indoor applications tube light fitting 1x10 Watt, 2 FT complete, Trim LED NEO including all fixing arrangement complete, all as specified and as directed by the Engr-in-Charage. Make: As per Wipro Cat Part No LL20-221-XXX-65-NE or equivalent in Philips/OSRAM.
LED street light fitting 1x25 watt with lamp pressure die cast housing with epoxy powder coated dark graphite grey colour finish, prismatic polycarbonate cover with individual LED lenses with bracket of made of GI pipe 1.5 mtr length,bent to the shape including necessary clamps, nuts bolts etc; complete all as specified and as directed by the Engr-in-Charage. Make Crompton Cat Part No LSTS 25-CDL- LED or equivalent in Philips/OSRAM/CG
Exhaust fans, AC, single phase, 230/240 V of size 300 mm sweep with sturdy steel bird guard with specially designed metal blade and making connection of exhaust fan to ceiling rose by copper flexible wire complete all as specified & directed by Engr-in-Charge. Make : Havells Ventil Air-DS or equivalent in Bajaj/Philips/Crompton Note:Labour charges for fixing including electric connection & making hole in wall and plaster work shall be part of job at no extra cost.
Electric water heater, storage type, capacity 25 ltr, BEE 5 star rated complete all as specified and directed by Engr-in-Charge. Make: Jaquar Model Elena/Racold Model ALTRO 2/Venus Model: WAVE Note : Fixing of geyser on wall with suitable size anchore bolt with hammer drill and making good the disturbed surface including plaster work shall be part of job at no extra cost.
Galvanised iron pipe, medium grade, 15mm bore, ISI marked with screwed socket joints together with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, lugs and union etc.,fixed to wall surface/laid in floors/on supports etc; complete all as specified and directed by Engr-in-charge.
Supply & fixing of PVC bib tap standard of PTMT any colour high pressure screwed for iorn pipe and fixed 15mm dia GI pipe complete all as specified and directed by Engr-in-Charge.
Stop valve, 15mm bore, cast copper alloy, screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions suitable complete, fancy type, chromium plated, complete all as specified and directed by Engr-in- Charge.
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick burried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40x40x6mm and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate complete all as specified and shown in EP-3 of SSR Part-I & as directed by Engr-in-Charge.
1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all specified and as directed by the Engineer-in-Charge.
House service bracket (hook type) complete with 3.0m long G.I pipe 40mm dia medium grade two nos 90 degree bends M.S. hook etc complete all specified and as directed by the Engineer-in-Charge.
M/S DAYA SONS
jatindera enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .