Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 LAccepted-Finance | L1 | Accepted-Finance Accept | |
| 2 | L2₹3.5 L+₹8,845 (2.57%)Accepted-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Accepted-Finance Accept |
Tender Value
₹3.3 L
EMD Value
₹6,561
Closing Date
19 Feb 2024, 3:00 pmClosed
Executive Engineer (E)
O/o Executive Engineer (Electrical) BSNL, Electrical Division 1st Floor, Telephone Exchange Laxmi Road, Dehradun
Please refer tender documents
2024_BSNL_185261_1
69/EE(E)/BSNL/ED/DDN/23-24
Open Tender
Electrical Works
Item Rate
180 days
Haridwar
Please refer tender documents
4 documents required · 4 mandatory
₹590
Accounts Officer (Cash), O/o GMTD, BSNL, Haridwar
₹6,561
20 Apr 2024
9 Feb 2024
20 Feb 2024
9 Feb 2024
19 Feb 2024
9 Feb 2024
Amount
Visitng charges including to & fro journey charges of Electrician on Call basis for repairing of Elect accessories (except DGs and ACs) in various exchanges/ BTSs i/c analysis of fault, minor repiring , cleaning of free cooling filter/ ACs filters etc comp as reqd.
Visit Charge per site in SDCA area
Visit Charge per site outside SDCA area
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & fixing Analog daily time switch of 16 A Capacity ,One C/O ,Din /Base mounting , 24 hour Programmable operation for Used for Automatic switching ON/OFF for Electric street lights suitable to work on 230 V AC Supply i/c connection etc Timer - (Make-L&T /GIC or similar superior make)
S/F of following electrical items in existing Electrical Installation ,Compound light I/c dismantling of existing faulty items (if required ) and connection, testing etc. as reqd.( Note- All spare of lighting systen should be of Make -Bajaj/crompton/philips /havells /wipro )
4'- 36 Watt Fluoresent Tube Rod
Electronic Ballast suitable 36 / 40 Watt tube fitting
Flu tube Starter
2.5 to 4 MFD MPP capacitor for fan
18/20 W Retrofit Pin type LED Bulb
9 W Retrofit Pin type LED Bulb
Batten Holder
5 Amp. Piano Type switch.
3 Pin ,5 Amp. Socket outlet.
15/16 Amp. Switch.
15/16 Amp , 3/6 pin Socket outlet.
S/F of following item in existing main baord of UPCL supply i/c connection and dismentling of existing faulty unit etc as reqd
63 A,514 V Porcelene rewirable KIT KAT fuse base and carrier confirming to relevent is specification Make (Havells or similar superior make)
Lugs 16 sqmm/25 sqmm
Supplying and fixing of following size of flexible round copper cable on surface/ recess with suitable clamp , suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd ( Make -Polycab/Havells/Finolex )
3x2.5 sq mm
2x1.5 sq mm
3x1.5 sq mm
Rewinding of following fan motor with suitable gauge copper winding wire I/c dismantling, servicing, replacement of bearing/bush and reinstallation, testing etc. as reqd.
Ceiling fan up to 1400 mm size
Exhaust fan fan up to 300 mm size (Free Cooling )
Exhaust fan fan 450 mm size
S/F of following size energy efficient Ceiling fan suitable for operation on 230 Volts ,single phase 50 Hz AC supply complete etc as reqd without regulator)Make -( Bajaj/Polar /USHA /crompton /havells /orient )
SITC of 1x18/20 Watt LED Batten luminare with polycarbonate Housing having efficency 100 lumes /watt complete suitable for work on 230 volt 50Hz AC supply i/c connection testing etc complete as required.(Make -Philips /crompton/Havells /Bajaj/Wipro/Surya ).
S/F of 6 W Surface mounting LED panel square flush model suitable for work on 230 V etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro).
SITC of 25 Watt Energy Efficient LED type Road Light luminare with pressure die cast aluminum with mid power LED's as light sources & Heat Resistant toughended glass with frame cover and integral electronic driver complete with IP 65 protection ,min.system efficacy 100 lm/Watt suitable for work on 140-270 V AC Supply i/c ixing on existing GI bracket / Pole and connection i/c removing of existing faulty light etc as reqd (Make -Philips /crompton/Havells /Bajaj/Wipro).
Supplying and fixing of 10-60A capacity three phase Electronic Energy meter with LCD Display in polycarbonate housing with class 1 accurecy i/c fixing the same ,connection i/c dismentling of existing faulty unit(if reqd) etc as reqd ( Make L&T /HPL/or SS)
Supplying & fixing of Powder coated Free Cooling unit made out of 18 gauge M.S.Sheet box with locking door in front & jali in back side i/c Supplying & fixing 300 mm sweep Heavy Duty Exhaust Fan suitable for 230 V 50 HZ AC Supply i/c making opening in brick wall / window for fixing of unit, connection , testing etc (Exhaust Fan Make-- Crompton / Havells/ Bajaj or similar superior make )
Out door unit ( For exhaust of hot Air)
S/f timer unit constituting of 01 no. digital type thermostat/ Temp controller with LED display & sensor with lead and 01 no. Analog Time Switch /Electronic timer (1 second to 10 hrs ) in suitable size MS box with hinged door, connection etc. as required. (Timer Make-BCH/L&T/GIC-J648B1 & Analog Time Switch make - SELEC - TC513/TC533BX or similar superior make) Note-- Timer will run Exhaust fan for 2 hrs and kept in off position for 15 minutes
Supplying and laying of following size of pvc insulated pvc sheathed 1.1 kv grade Aluminium conductor armoured cable confirming to relevant IS-Specification i/c laying the cable in air /a/w GI Wire /surface /recess complete as reqd. (Make -Polycab/havells/finolex)-
4 X 16 sq. mm
Supplying and making End Termination with brass compression glands for the following sizes of PVC / XLPE insulated PVC sheathed & armoured 1100 V grade cable including cost of crimping lugs / ferrules, compression glands, solder, cable sockets, insulation tap etc. complete as required.
4 x16 Sq.mm.
Fixing of existing recovered 63/100 Amp. 3/4 Pole MCCB/ Switch fuse unit in lieu of faulty /burnt Kit kat fuses i/c removal of faulty kit kat ,interconnections etc. complete as required.
S/F of 63 amps four pole ON load change over switch in steel enclosure with side handle operation capable of working 415/500 V i/c fixing the same on wall /pole with suitable clamp/fastner i/c drilling hole , making connection, earthing the body etc. i/c dismenting of existing faulty unit (if requiredat site)as reqd.
JAI SAI ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .