Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 20 2169 PALLURTH PO ERNAKULUM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹6.4 L+₹18,789.74 (3.02%)Rejected-Finance 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | L3₹8.7 L+₹2.4 L (39.3%)Rejected-Finance 18 837 KILIYARAA HOUSE PERUMPADAPPU PALLURUTHY PO KOCHI 682 006 | KOCHI | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
9 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
ADDITION/ ALTERATION TO TECHNICAL BUILDING AT INS DRONACHARYA UNDER GE FORT KOCHI
2023_MES_618344_1
8965/E8/GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
FORT KOCHI
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE FORT KOCHI
₹18,000
Yes
18 Jan 2024
5 Oct 2023
11 Nov 2023
5 Oct 2023
9 Nov 2023
21 Oct 2023
Amount
Supply, install, testing and commisioning of Inverter Split Air conditioner 2 TR capacity with copper condensor coil, ,dual compressor,cordless remote control, 5 Star rated EER , R32 refrigerant, AC,230 Volts, 50 Hz including all fixing, hoisting arrangements complete all as specified and as directed.
Supply and fix 25mm dia Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for AC drain pipe extention complete all as specified and as directed.
Supply and fix voltage stabilizer 5 KVA for automatic operation with low and high voltage protection relay, single phase naturally air cooled indoor type & designed for in put variation between 90 V to 300 with out put voltage stabilized at 230 V with accuracy of + 2.5% suitable for 2 TR Split AC complete all as specified and as directed.
Tools and labour for disconnecting/cutting the old unsv air conditioning chillar pipe with insulation approx length 10 mtr by cutting wall including dismantling of blower complete unit and deposit to store and making good the disturbed area by pluging old chillar pipe from bottom of the building complete all as specified and as directed.
Supply & fixing metal clad single pole and natural enclosure 240 volts with a two pin and earth plug and socket complete with one single pole MCB 32 Amp complete all as specified and as diredted.
M&L submain wiring surface type with 2 runs of single core 4 sqmm size PVC insulated unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC conduit and its accessories including provision of one run of 4 sqmm PVC insulated single core unsheathed copper multistranded conductor cable as earth continuity wire complete all as specified and directed. Note :-2 runs of 4 sqmm size cable, one run of 4 sqmm size earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S&F MCB DB double door made of sheet steel phosphates, powder painted with bus bar, neutral link, earth bar and rail double door type TPN 415 volts 4 way fixed concealed /recessed having IP-43 protection including cement mortar 1:3 for making good to distrubed surface match with existing surface incl colouring complete all as specified
Supply and fix MCB SP 6 to 32 Amps, 240 Volt, having breaking capacity 10 kA, B curve with visual indication complete all as specified.
Supply and fix MCB TPN, 40 to 100 Amps, 415 Volt, having breaking capacity 10 KA, C curve complete all as specified.
Supply and laying in trench/duct/wall etc Cable XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminimum conductor of size 70 sq mm 3.5 core complete all as specified and as diredted.
Supply and fix MCCB 4 pole 200 Amps, 36 kA with Adjustable Thermal & Fixed Magnetic,fixed in wall mounted sheet metal enclosure with locking arrangement and provn of hole for incoming and out going cables complete all as specified and as directed.
Supply, install, testing and commissioning of factory made and tested Outdoor type wall mounted LT panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on aluminum bus bar of rating 200 Amps for phases on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 3.0 mm CRCA sheet duly powder coated after seven tank process .The panel shall be front openable type double door adequate space all around acessories sucxh as LT switchgear and measuring instruments including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessories INCOMINGS (a) MCCB 125 Amps 35 kA, 4 Pole, fixed type LT 415 V AC grade having microprocessor based release for over current and earth fault protection and interlock trip push button complete IS 2516 marked - 01 No (b) Digital Volt meter-01 No (c) digital ampere meter-01 No with necessery CT coil OUTGOING (a) MCCB Adjustable Thermal & Fixed Magnetic 40 Amps 25 kA, 4 Pole, -5 Nos (b) MCB 40 Amps 10 KA, 2 Pole, fixed type LT 230 V AC grade -2 Nos (c) Internal wiring of panel with stranded copper cable of suitable size (d) LED phase indicating lamp(Set of three)-01 Nos (e) Stenceling of panel board including marking of distribuitions
M&L for earthing complete with galvanised iron or steel plate earth electrode of size 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level with top edge of the plate not less than 1.5 meter below ground level, earth plate shalll be surrounded on all sides with 15 cm thick layers charcoal dust mixed with salt connected to and including galvanised earth strip 32x 6 mm as earthing lead by means of GI nuts, bolts and washers at one end and other end shall be connected to test point complete all as shown on electric plate No 3 of SSR Part I (2009) including excavation and earth work in any type of soil, PCC pit (1:2:4), RCC earth pit cover and suitable handle, 20mm bore GI medium grade watering pipe with wire mesh and funnel, 40mm bore GI medium grade protection pipe including testing on completion complete all as specified and as directed.
Supply and laying synthetic rubber insulated mats 2.5mm thick for voltage up to 11 kv (size 2x1m) complete all as specified and as directed.
Supply and laying GI tube light grade 80mm dia for cable protection on wall /under floors etc complete all as specified and as directed. Note : Unit Rate include necessary PCC work to make good the disturbed surfaces on wall/floor etc
WELTRONENGINEERINGSERVICES
Anaswara Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .