| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | ₹29.5 L Quoted ₹30.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹31.5 L+₹1.2 L (4.03%)Rejected-AOC | ₹31.5 L+₹1.2 L (4.03%) | L2 | Rejected-AOC L2 |
| 3 | L3₹31.5 L+₹1.2 L (4.09%)Rejected-AOC | ₹31.5 L+₹1.2 L (4.09%) | L3 | Rejected-AOC L3 |
| 4 | L4₹36.0 L+₹5.7 L (18.9%)Rejected-AOC | ₹36.0 L+₹5.7 L (18.9%) | L4 | Rejected-AOC L4 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
6 Jul 2023, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services Garrison Engineer (Naval Services) Kataribagh, Naval Base Post Kochi 682004.
REPAIR/MAINTENANCE OF UG CABLE, EARTHING, JUNCTION BOXES AND PANELS AND STREET LIGHTS SYSTEM AT KATARIBAGH AREA AT NAVAL BASE KOCHI AND REPAIR / MAINTENANCE OF CERTAIN ELECTRICAL WORKS INSTALLATION UNDER AGE E/M NO II.
2023_MES_601338_1
8246/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Kochi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹82,000
Yes
15 Sept 2023
6 Jun 2023
8 Jul 2023
6 Jun 2023
6 Jul 2023
23 Jun 2023
6 Jun 2023 - 22 Jun 2023
Amount
Taking down existing street light/flood light/solar light fittings carefully (any capacity, any type) from pole 7/9/11 metre or building carrying out necessary repairing at E/M yard and re-fixing into the existing location including replacement of unserviceable/ defective spare parts i.e., (LED fitting /drivers) and removing existing green bushes, tree small Branches complete all as specified and directed. Notes: (i) Major Spare parts required for repair shall be measured and paid under relevant item of BOQ. Minor spare parts such as screw, nuts, bolts, washers etc , which shall deemed to be included in unit rate quoted. (ii) Tools, electrical measuring instruments, ladder required to carry out the work shall be provided by the contractor and has to show the Engineer-in-Charge before starting the work. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate for the commencement of work. (v) Contractor has to supply first aid kit to their workers and has to show the Engineer-in-Charge before starting the work (vi) Contractor should ensure all the street lights are functional before leaving the station and rep of contractor should check after all the lights are switch ON after rendering completion to respective JEs/Engineer-in Charge as day to day basis.
Taking down existing garden light fittings carefully (any type) of post top lantern, carrying out necessary repairing at site and re-fixing into the existing location including replacement of unserviceable/ defective spare parts (such as lamp, holder, etc), cleaning of acrylic cover with detergent and replacement of internal wiring with two runs of PVC insulated 1.5 Sqmm copper conductor cable from fittings to connector block and testing after re-fixing at site complete all as specified and directed . Notes: (i) New Spare parts retrofit holder, LED bulb shall be measured under supply only. (ii) Tools, electrical measuring instruments, ladder required to carry out the work shall be provided by the contractor and has to show the Engineer-in-Charge before starting the work. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provide Skilled ITI Electrician and Produce the Certificate for the commencement of work. (v) Contractor has to supply first aid kit to their workers and has to show the Engineer-in-Charge before starting the work (vi) Contractor should ensure all the street lights are functional before leaving the station and rep of contractor should check after all the lights are switch ON after rendering completion to respective JEs/Engineer-in Charge as day to day basis.
Taking down in Repair to High Mast light 15/12Metre Height complete down the assembly and check the all light fitting and replacement of the unserviceable parts (LED Drive) and other Materials found rusted Changed with New Spares and Clean the all fittings make serviceable complete all as directed. Notes: (i) Spare parts shall be measured under supply only item except minor spare parts such as screw, nuts, bolts, washers etc, which shall deem to be included in unit rate quoted (ii) Tools, electrical measuring instruments, ladder required to carry out the work shall be provided by the contractor and has to show the Engineer-in-Charge before starting the work. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate for the commencement of work. (v) Contractor has to supply first aid kit to their workers and has to show the Engineer-in-Charge before starting the work) (vi) Contractor should ensure all the street lights are functional before leaving the station and rep of contractor should check after all the lights are switch ON after rendering completion to respective JEs/Engineer-in Charge as day to day basis.
Supply and laying of XLPE insulated PVC sheathed, armoured, heavy duty, aluminium conductor electric cable 1100 Volt grade of 10 Sqmm 2 core in duct/floor/wall with provision of saddle and lugs, etc including taking down of old one, complete all as specified and as directed.
Ditto all as per serial item No 04, but for size 10 Sqmm 4 core.
Ditto all as per serial item No 04, but for size 16 Sqmm 4 core.
Ditto all as per serial item No 04, but for size 25 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 35 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 50 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 70 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 95 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 120 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 150 Sqmm 3.5 core.
Ditto all as per serial item No 04, but for size 185 Sqmm 3.5 core.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth and getting out in soft / loose soil for laying of cable complete all as specified and directed by the Engineer-in-Charge.
Material and labour for sand cushioning for underground cables complete all as specified and as directed by the Engineer-in-Charge. (Note: for the Measurement purpose only punned thickness shall be measured & paid)
Supply and laying in replacement un-reinforces precast concrete cable cover , class LV Type I as per IS-5820 with flat size 250X150X40mm laid dry in trenches over underground cables complete all as specified and directed.
Returning and filling of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and directed.
Cutting existing road/hardstand/concrete blocks/slabs/brick work or stone masonry of any type by using crow bar chisel up to a depth of 30 cm for laying GI pipe including making good the surface by returning filling watering ramming in layers cold mix bitumen over 200 mm thick hard core of broken bricks/stones over returning filling watering ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Supply and fix GI bracket for street light fitting made out of 40 mm dia medium grade pipe bend to 120 degree angle shape, drilled holes etc 1.5 m long with clamps, nuts, bolts etc & taking down old unserviceable complete all as specified and directed.
Supply and fix in repair LED Street light fitting 1x60 Watt pressure dia cast aluminum housing heat resistant toughened glass with frame with IP 66 Protection including taking down old unserviceable fitting, complete all as specified and directed.
Supply and fix in repair LED Street light fitting 1x100 Watt pressure dia cast aluminum housing heat resistant toughened glass with frame with IP 66 Protection including taking down old unserviceable fitting complete all as specified and directed .
Supply and fix in repair LED Flood light fitting 1x50 Watt RGB pressure dia cast aluminum housing heat resistant toughened glass with frame with IP 66 Protection including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in repair LED Flood light fitting 1x70 Watt pressure dia cast aluminum housing heat resistant toughened glass with frame with IP 66 Protection including taking down old unserviceable fitting complete all as specified and directed.
Supply, fixing and commissioning, testing of 100 Watt LED flood light complete with toughened glass including LED bulb and all standard accessories as per design of manufacturer suitable for IP-66 degree of protection , including taking down old unserviceable fitting complete all as specified and directed.
Supply, fixing and commissioning, testing of 200 Watt LED flood light complete with toughened glass including LED bulb and all standard accessories as per design of manufacturer suitable for IP-66 degree of protection, including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in replacement of LED post top lantern15 watts WH/WW, warm/cool in colour die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside, epoxy powder coated matt black finish after phosphochromate treatment and light source of High efficiency long life LED module with SMD LED package mounted on MCP CB and viewing angle of 116 degree suitable for mounting with OD of 70 mm max with 3 Nos hexa screw etc including taking down old unserviceable fitting complete all as specified and directed.
Supply and fix in replacement of LED post top lantern 25 watts WH/WW, warm/cool in colour, die-cast aluminium spigot for mounting LED driver and spun aluminium canopy which is painted white inside, epoxy powder coated matt black finish after phosphochromate treatment and light source of High efficiency long life LED module with SMD LED package mounted on MCP CB and viewing angle of 116 degree suitable for mounting with OD of 70 mm max with 3 Nos hexa screw etc , including taking down old unserviceable fitting complete all as specified and directed.
Supply only1x60 Watt LED Street Light Driver.
Supply only 1x50/45 Watt LED Street Light Driver.
Supply only LED 18 Watt classic/thread type bulb in WW/WH colour.
Supply and fix in replace with white colour Doom of any size for Garden light fitting complete including taking down old unserviceable fitting complete all as specified and directed
Material & Labour for Painting to steel tubular pole of any height of size with two coats of aluminium paint including preparation of surface, marking pole number as existing size of 50mm height in black colour with yellow back ground in round shape of dia max up to 150 mm all as per the direction of the Engineer-in-charge
Material & Labour for two coats of Cement Based Painting to Concrete pole of height 7 metre marking pole No as existing, size of 50 mm height in black colour with yellow back ground in round shape of dia max up to 150 mm and all as per the direction of the Engineer-in-charge.
Supply only wiring with two run of PVC (FR) insulated multistranded copper conductor cable of 1.5 sqmm drawing through PVC conduits with continuous earth wire PVC (FR) insulated cable of size 1.5 Sqmm connected to earth including all conduit accessories complete. (Note: Two run of sub main wire, one run of earth wire and one run of PVC Conduit pipe measured as one unit).
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 6 sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor of size 4.0 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, of size 2.5 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular complete all as directed.
Supply and fix in replacement of junction box made of thermoplastic of size 126x228x111mm with IP 67 protection including cable connector and MCB brackets including SP 6 Amps MCB with suitable size clamps fixing for pole/in PCC foundation including taking down old unserviceable fitting complete
Taking down old rusted unserviceable Garden light fitting pipe of any size by removing existing location and refixed with new 40 mm GI pipe Medium grade 3 metre Long repair to existing PCC foundation Size 30x30x45cm by using PCC 1:2:4 type B1 (using 20mm graded stone aggregates) as in coping. connected existing cable to the Junction Box, garden light Fitting and make Serviceable complete all as directed (Note:- Earth Work/PCC work shall deemed to be included in unit rate quoted )
Material & Labour for GI tubing medium grade (ISI marked) with all fitting/accessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc all as specified and directed of size 40 mm dia including taking down old unserviceable tubing complete all as specified and as directed
Ditto all as per serial item No 42, but for size 80 mm dia.
Supply and fix Post Top lantern mounting pole 60mm OD made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp 14/18W B22 base including taking down old unserviceable fitting complete all as specified and as directed
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Metre deep below ground level with top edge of the plate not less than 1.5 metre below ground level connected with galvanised strip of size 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (reinforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work complete.
Supply and fix cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 70 to 150 Sqmm including taking down of old one complete all as specified and as directed.
Supply and fix cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 25 to 50 Sqmm including taking down of old one complete all as specified and as directed.
Supply and fix cable jointing kit for straight through heat shrinkable type joint with jointing material and all connected accessories suitable for XLPE armoured aluminium conductor cable 1100 volts grade suitable for 3.5/4 core x 10 to 16 Sqmm including taking down of old one complete all as specified and as directed.
Supply and fix in replacement MCCB 4Pole, 63 Amps, 50 kA, 415 Volt, with adjustable thermal & adjustable magnetic setting Ics=75% Icu including taking down old unserviceable MCCB complete all as directed.
Ditto all as per serial item No 49, but for MCCB 4Pole, 100 Amps.
Ditto all as per serial item No 49, but for MCCB 4Pole, 200 Amps.
Ditto all as per serial item No 49, but for MCCB 4Pole, 250 Amps.
Ditto all as per serial item No 49, but for MCCB 4Pole, 400 Amps.
Dismantling/taking down steel tubular pole/RCC pole any size by cutting from foundation by means mechanically or manually all as specified and directed by Engineer In Charge.
Supply and Fixing hot dipped GI octagonal pole of 6 Metre long with 01 Metre arm suitable for mounting of 01 Nos of LED street lights complete with base plate and GI foundation bolts and nuts complete all as specified and directed.
Supply and fix Danger Notice plate of 1.6 mm Thick Mild steel Sheet of 20X15 Cm size, Vitreous enameled white, Letters, figures and conventional Skull and bones in single red colour and fixed with MS clamps, bolt and nuts of approved size for LT, complete all as directed by Engineer-in-Charge.
Supply & Fix in street light TIMER control panel, pole/wall mounting made out of CRCA sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements and comprising of following or as manufactures recommendation and design including taking down old unserviceable timer panel complete. (a) Incomer MCB TPN 63/100 Amps, 240/410V- 01 Nos (b) Digital timer switch - 01 No (c) Contactor AC 3 rating, 3ph, of capacity 65/100 Amps - 01 No (d) ON/OFF indicating lamp - 01 Set (e) Auxiliary change over switch 6 A - 01 No
Supply and fix in repair Digital timer Switches DIN Type Programmable every 1 Min, with Backup of 6 Years, 28 Memory Locations, current Capacity 16A, weekly program, with 1 Changeover (1co) total 28 Programs complete all as directed.
Supply and fix in repair three pole power contactor 80 Amp complete all as directed.
Supply and fix in repair MCB SP, 6 Amp - 32 Amp "C" curve, 240/415 volt AC complete all as directed.
Supply and fix in MCB TPN C series 63 Amp complete all as directed.
Material & Labour for painting of LT panels / Junction Boxes of any size and type with two coats of enamel paint over one coat anti corrosive paint, including preparation of surface , by removing old paint, proper cleaning , filling cavities with filler should applied internally and externally all as specified and directed .
Supply and fix in repair Solar LED Post Top with built in solar panel, LED light and lithium battery with charge controller and 2 PIR sensor with 360 degree coverage light fitting 20 Watt 5700 K pressure dia cast aluminum housing heat resistant toughened glass with frame with IP 66 Protection complete all as specified and directed.
Supply & Fix in replacement Post Top lamp LED with moonlight effect and efficient light distribution, having rated IP65 protection, suitable for 3 metre long die cast aluminium pole complete with base plate and GI foundation bolts and nuts including earth work and PCC foundation compete all as specified.
Material & Labour for marking pole number as existing size of 50mm height in black colour with yellow back ground in round shape of dia max up to 150 mm all as per the direction of the Engineer-in-charge
Attending complaints / breakdown of LT electrical system and taking down existing connection from LT Panel/Bus Bar Chamber/Feeder Pillar/ Electric Poles/ Building carefully (any capacity ,any type) carrying out repair work at site including replacement of unserviceable/ defective screw/nut & bolts/ Washers /Lugs /Spreaders /Hinges of doors/Repair to Locks & handles/ Indication Lamps/meters/Cable glands/Bus Bar (Copper/Aluminium) etc, refixing the fittings in its original position, testing and commissioning, including removal of bushes, creepers and trimming of branches around the LT Panel/Bus Bar Chamber/Feeder Pillar/ Electric Poles complete all as specified and directed. Notes: (i) Major Spare parts required for repair shall be measured and paid under relevant item of BOQ. Minor spare parts such as screw, nuts, bolts, washers etc , which shall deemed to be included in unit rate quoted. (ii) Tools, electrical measuring instruments, ladder required to carry out the work shall be provided by the contractor and has to show the Engineer-in-Charge before starting the work. (iii) Contractor will ensure the safety of the workers employed at his own risk. (iv) Contractor shall provided Skilled ITI Electrician and Produce the Certificate for the commencement of work. (v) Contractor has to supply first aid kit to their workers and has to show the Engineer-in-Charge before starting the work (vi) Contractor should ensure to rendering completion of all attended complaints to respective JEs/Engineer-in Charge as day to day basis.
Notes for Sl.No 1 to 66 above: Contractor has to quote the tender taking the below mentioned points into consideration and the rates of the above items are inclusive of the below mentioned points. (a) The contractor shall provide skilled ITI electricians and Helpers for 8 Hours from 0900 hours to 1700 Hours. (b) The contractor has to arrange skilled ITI electricians and Helpers taking into consideration that the complaint will be attended at two places at the same time in Kataribagh area. (c) All the Lights / LT cable / Electrical components breakdown complaints has to be attended immediately and completed on the same day. (d) Contractor has to note that the complaints will be raised everyday and the contractor staff has to attend the complaints on day to day everyday basis complete for the span of the contract. (e) Contractor has to arrange sufficient labours during breakdowns as directed by the Engineer-in-Charge. (h) If the Contractor is not attended the complaint or delaying complaint, the penalty will be imposed @ Rs 2500/- per day.
Taking down Copper /aluminium point wiring (light, fan, socket, bell, power point) complete fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting any type, building security light removing materials to store for keeping in safe custody for taking credit and making good the disturbed surfaces complete all as specified and directed.
Material & Labour for Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 Sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade including PVC conduit surface mounted and connected accessories ISI marked with concealed sunken boxes with modular cover plate, PVC boxes, hylem sheet, including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLSH cable single core multistranded cable as earth continuity wire for light/Fan point controlled by one switch complete all as specified and as directed.
All as per item No 68 here-in-before but for 5 pin 5 Amps socket outlet point on independent board.
All as per item No 68 here-in-before but for 5 pin 5 Amps socket outlet point on same board.
All as per item No 68 here-in-before but using 2.5 Sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable and 2.5 Sqmm copper conductor cable (multistranded) PVC insulated FRLSH and unsheathed cable earth wire with terminal box of suitable size of modular switch & socket for one 6 pin 15 Amps socket outlet point on independent board complete all as specified.
Supply & Fix switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
Supply & Fix switch socket combination 5 Amps, 5 pin 2 in 1, complete all as specified and as directed.
Supply & Fix in switch socket combination multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified and directed.
Supply & Fix fan regulator electronic step type 100 W, 250 Volts complete all as specified and as directed.
Supply & Fix ceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
Supply & Fix in repair, capacitor for ceiling fans, 230 volts, 2.5 MFD including necessary soldering complete all as specified and as directed
Supply & Fix in repair, capacitor of capacity 4 MFD for any type of exhaust fan/pedestal fan/air circulator fan 230 volts AC including necessary soldering complete all as specified and directed.
Supply & Fix in repair, lamp holder, PVC /poly carbonate type with back plate suitable for batten fittings complete all as specified and directed.
Material & Labour in repair sub main wiring with 4 runs of 10 Sqmm PVC insulated unsheathed multistranded single core copper conductor FRLSH, ISI marked cable drawn through ISI Marked, medium grade, non metallic, PVC casing & capping and all accessories, with 1 run of 10 Sq mm PVC insulated unsheathed multistranded single core copper conductor FRLSH, and making good disturbed surfaces, applying distemper / Emulsions matching to the existing colour / quality of walls/floors/ceiling etc complete all as specified. Note:- Five run of cable and one run of PVC casing and capping shall be measured as one unit.
All as per item No 80 here-in-before but 2 runs of 4 sq mm single core FRLSH copper conductor and 1 run of 4 Sqmm conductor for earthing. Note:- Three run of cable and one run of PVC casing and capping shall be measured as one unit
All as per item No 80 here-in-before but 2 runs of 6 sq mm single core FRLSH copper conductor and 1 run of 4 Sqmm conductor for earthing . Note:- Three run of cable and one run of PVC casing and capping shall be measured as one unit
Supply & Fix in repair, Sheet Metal Enclosure for MCB DB, TPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.
Supply & Fix in repair, Sheet Metal Enclosure for MCB DB, SPN, 4 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
Supply & Fix in repair, Sheet Metal Enclosure for MCB DB, SPN, 8 ways, double door, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
Supply & Fix in repair, MCB, TPN, 63 Amps, 415 Volt, B curve, having breaking capacity 10 KA, complete all as specified.
Supply & Fix in repair MCB, SPN, 63 Amps, 415 Volt, B curve, having breaking capacity 10 KA, complete all as specified.
Supply & Fix in repair MCB, SP, 6-32 Amps, 240 Volt, B curve, having breaking capacity 10 KA, complete all as specified.
Supply & Fix in repair MCB, SPN, 6-32 Amps, 240 Volt, B curve, having breaking capacity 10 KA, complete all as specified.
Supply & Fix in repair LED light fitting 20 Watt, high performance batten, 220 volt, 50 Hz, 6000 k surface mounted high quality extruded polycarbonate, environmental friendly, energy efficient, with all connecting accessories, with suitable connection complete all as specified.
Taking down unserviceable ceiling fan of 1200mm/1400mm sweep, cutting out the existing burnt out fan motor winding, cleaning the motor slots, rewinding the motor with insulated copper winding wire of existing gauge, baking / heating up the motor to achieve the proper insulation resistance and re-hanging / refixing after repair including applying a coat of synthetic enamel paint (Glossy Finish) with spray gun, marking MES No complete all as specified.
Ditto all as per Serial Item No 91 above but exhaust fan of 450/300/250 mm sweep complete all as specified.
Material & Labour in repair Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4 mm dia as earth lead up to 7.5 metre distance and connected by means of bolts, nuts, check nuts and washers of galvanised iron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with 8 mm dia TMT bars both ways @ 10 cm centre to centre , 20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI medium grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 metre etc including testing on completion complete all as specified. Notes: - (i) The unit rate includes for protection pipe and earth lead up to 7.50 Metre. (ii) Earth lead beyond 7.50 Metre length shall be measured and paid separately.
Supply & Fix in repair LED building security light 50 watts, 50 Hz, 220 volts having IP-65 protection, pressure die cast aluminium housing, high luminous efficiency and high power complete all as specified
Supply & Fix in repair very high efficiency round high bay 80 Watt in PDC housing suitable for industrial application, The luminaries has efficiency up to 140lumen /watt to reduce quantity / wattage thereby reducing operational cost. It has 10KV SPD and ingress protection of IP66 with additional chain all as specified and directed
Supply & fix in repair LED ceiling light fitting 42 Watt, 2X2 ultra modern designed LED luminaries which provides soft light and glare free symmetrical illumination suitable for Armstrong / grid ceiling with all connecting accessories ,with suitable connection of any height complete all as specified.
Supply & fix in repair Plastic body exhaust fans AC single phase 230/ 240 Volt of size 300 mm sweep, 900 RPM complete including taking down old one complete all as specified
Supply & fix in repair Plastic body exhaust fans AC single phase 230/ 240 Volt of size 200 mm sweep, 900 RPM complete including taking down old one complete all as specified
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
V V BHARATH ENTERPRISES
ELSOL ENGINEERS
PHEJAYS AGENCIES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .