| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-Finance VILLAGE AMLEHAR P O JANDAUR TEHSIL JASWAN DISTT KANGRA HP | L1 | Accepted-Finance Lowest | |
| 2 | L2₹12.6 L+₹2.2 L (21.0%)Rejected-Finance LOWER BAZAR SARKAGHAT DISTT MANDI H P | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹13.0 L+₹2.6 L (24.5%)Rejected-Finance LAXMI BAZAER TEHSIL JOGINDERNAGAR DISTT MANDI HP | MANDI | HIMACHAL PRADESH | 175001 | L3 | Rejected-Finance other than lowest |
Tender Value
₹11.2 L
EMD Value
₹22,500
Closing Date
20 Dec 2024, 5:00 pmClosed
Executive Engineer
Executive Engineer Jal Shakti Division Mandi
Construction of Intake Well and Supply and installation of submersible pumping machinery with allied accessories
2024_HPIPH_96406_1
11526-55
Open Tender
Civil Works - Others
Item Rate
90 days
GP Masad
Please refer Tender documents.
8 documents required · 8 mandatory
₹400
Yes
₹22,500
Yes
26 Mar 2025
10 Dec 2024
21 Dec 2024
10 Dec 2024
20 Dec 2024
10 Dec 2024
Amount
Excavation in foundation and trenches etc. in earth work in all kinds of soil such as pick work, jumper work, blasting soft or hard rock or by chiselling soft or hard rock where blasting is prohibited in all leads and lifts including trimming / dressing of sidesand bed stacking the excavated soil clear from the edge of excavation and returning the excavated soil after completion of work in 15cm layers when required into plinth , sides of foundation etc. consolidating each deposited layers by ramming and watering and then disposing of all surplus excavated soil complete in all respect as per the direction and to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete 1:4:8(1cement :4sand : 8graded stone aggregate 40 mm nominal size) and curing complete excluding cost of form work in foundation and plinth in all leads and lifts.
Providing and laying cement concrete 1:11/2 :3 ( 1cement: 1 1/2 sand: 3graded stone aggregate 20 mm nominal size )and curing complete excluding the cost of form work and reinforcement in all leads and lifts in:-Foundation, footings base of columns and the like mass concrete.in all leads and lifts
Walls any thickness but not less than 0.1 mtr. thickness attached pillasters, buttresses plinth and string courses etc. from top of foundation level upto floor two level in all leads and lifts
Providing form work with steel plates 3.15mm thick welded with angle iron 30x30x5mm so as to give a fair finish including centering shuttering strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4mtrs. and removal of the same for in-situ reinforced concrete and plain concrete work in all leads and lifts. (a) Vertical surface such as walls(any thickness) partitions and the like including attached pillasters buttresses, plinth and string courses and the like.
Tor steel rainforcement for RCC work including, binding and placing in position complete up to all heights in all leads and lifts.
Providing and fixing inlet pots will mounted with strainers of stainless steel of 150 mm dia as per direction and to the entire satisfaction of Engineer-in-charge.
submersible Pump Set :- Supply and errection of submersible pumping set of KSB /Calama/Johnison/Grundfos/JSV approved make comprising to latest IS code 8034:2002 (latest edition). The pump should be fitted with bronze impellers of suitable alloys as per BIS 5659-1970 latest suitable for having greased packed bearing and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft colupled to a submersible squirrel cage electric induction motor(water proof type) of required HP RPM 2900 of kirloskar/NGEF/cromptin/JSV approved make confirming to BIS9283-2013 latest with up to date amendments totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechenical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non verticle loads with minimum wear and tear. It should also be fitted with a device to make an expansion of water with the heating of motor. The pump set should include water level gaurd errection clamps clip & depth gauge etc. & suitable for operation on data given below:- Site Conditions.....Discharge(Q) - 16.46 LPS, Tatal dynamic heads - 73.78 Mtrs, LWL in Sump well - 1000.50 Mtrs, shaft level - 999.50 Mtrs, Level of Discharge Point - 1070 Mtrs, Discharge head - 73.78 Mtrs, Static head-70.50 Mtrs, Rising main.... Length - 250 Mtrs, dia- 150 mm dia, Pumping hours - 20 hours, Altitude of installation above MSL - 1000 mtrs, Temperature - 23* C.
Supply , Installation, Testing and Commissioning of Star Delta Starter panel for suitable capacity submersible pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/base mounted and front opening door type with copper insulated wiring suitable to operate 1 No. pumps working of the suitable HP through Star Delta Starter mechanism. Starter should be capable enough to handle the following faults like short circuit, over current, under current, over voltage, dry run protection and phase loss with LED ON/OFF & Trip indicators. Make: JSV approved/The product should be of Global Brand.
Star, Delta starter and Mains Power Contactors of required ratings as per type-2 co-ordination for suitable HP.
Voltage Protection device to protect panel from over voltage and under voltage.
Single phasing and phase reversal protection device to safeguard system from single phasing and phase reversal of the supply voltage.
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication.Make JSV Approved/ The Product should be of Global Brand.
Main incomer MCCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 (Latest edition).
Individual Starter incomer MCCB/MCB of suitable capacity of L&T / Schnieder/ABB make on the feeder for pumping set confirming to BIS 2516-1985 ( Latest edition).
Three phase indicator lamps complete loggled with switches for individual motors confirming to BIS 3452 ( part -I & II) latest with upto date amendments.
LED On / Off & Trip indicator and push buttons, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Bus Bar, i.e.Bolt, insulator, etc.
Surge supressor device with Isolating MCCB to eliminate the power surges due to lightening and system surges.
Control Transformer to provide a stable control volatge to safegaurd the control circuit of all the components from the voltage surges and spikes.
Independent Control Panel with Switch Fuse Unit and Fuses of Suitable ampare to eliminate the KItKat fuses of HPSEB Make: JSV Approved The product should be of Global Brand.
Providing double flanged cast steel sluice valve ASA-150 of required class of Leader/ Kirlosker make and one step higher then delivery line of pump and capable of withstanding normal seat pressure as per BIS standards with upto date amendments).
Providing double flanged cast steel reflux valve class,ASA-150/300/600 of required class of Leader/BHEL/ Kirlosker / Kartar/Kilburn /GLED /Fourses make for rising main and one capable of withstanding normal seat pressure as per BIS standards with upto date amendments).
Providing 100 mm dia circular dial analog pressure gauge of suitable range of Fiebig /Bourden/ PREGA/precision make complete with all accessories such as stop cock, copper tubing etc.as per IS: 3624-1987 with upto date amendments.
Providing discharge meter of standard make to be fixed on the rising main in pump house as per the directions of the Engineer in charge as per Is:2373:1981 with upto date ammendments.
Installation of all the items appearing as per the schematic drawing.
Providing and laying copper PVC insulated arsoured power cable (One cable carrying all the three phases) of suitable size and capacity to motors and all other electircal equipments as per IS:1554(P-I) 1988 or latest ith upto date ammendments of siemens/GLOSTER /IEC/ICC/EICO/NATIONAL/GRANDLAY make including all other accessories such as thinbles, flexible pipes,solders,nuts and bolts cable glands etc. laid in pipes or trenches under floor.Motor side 3 core (From switch to starter and starter to motor) 3 core cable.
Supply side 3.5 core (From Meter of HPSEB to bus bar and switch) 3.5 core cable.
Providing and fixing double loop earthing with GI plate 600mmx600x6mm thick electrode complete with material such thimbles nuts and charcoal and common salt, 25mmx5mm copper strips as per IS:3043:1987 with upto date ammendments for motors and other electrical equipments and digging of pits etc. complete in all respect.
M/S Anil Trading And Engineering Works (BID ID -463714)
M/ Shiv Shakti Traders (BID ID -463657)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .