Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.6 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.6 L+₹37,672 (1.24%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹31.1 L+₹88,625 (2.93%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹31.2 L+₹89,813 (2.97%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹32.5 L+₹2.3 L (7.55%)Rejected-Finance 30 DIGVIJAY PLOT RAVAL NIVAS JAMNAGAR GUJARAT 361 005 | JAMNAGAR | JAMNAGAR | GUJARAT | 361005 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
4 Nov 2020, 6:00 pmClosed
GE I NAVY JAMNAGAR
INS VALSURA JAMNAGAR 361150
WELCOME MAINTENANCE AND REPAIRING TO INTERNAL WIRING TO CERTAIN MD ACCN INCLUDING MAINTENANCE OF PREPAID METERS AND AM READING SYSTEM UNDER GE I NAVY JAMNAGAR
2020_MES_387355_1
8465
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I NAVY JAMNAGAR
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE I NAVY JAMNAGAR
₹60,000
Yes
22 May 2021
17 Oct 2020
6 Nov 2020
17 Oct 2020
4 Nov 2020
30 Oct 2020
17 Oct 2020 - 29 Oct 2020
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store and making good disturbed surfaces of walls, floors, etc to match with the existing surface complete all as directed.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through heavy duty PVC casing, capping, double lock type, min 25 mm wide including sheet metal box, terminal plates suitable for modular switch, socket etc. with all accessories, concealed MS box / PVC modular box with cover and 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 2 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No. 2 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed7
All as per item No. 2 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
M&L for point wiring with 1100V grade with 1.5 Sqmm single core PVC FRLS insulated cable, copper conductor multistranded passing through and including PVC concealed 20 mm dia conduit and conduit accessories with concealed MS/ PVC Box and logic modular white plate of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch complete all as directed. Note : (1) Rate include cost of cutting wall / floor / ceiling and making chasses and MS box in concealed for cutting and sinking for boxes and making good to walls, no extra payment will be made for the same. (2) Switch and socket shall be measured and paid separately.
All as per item No. 6 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 6 here-in-above but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as specified.
All as per item No. 6 here-in-above but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC FRLS insulated multistranded copper conductor cable all as directed.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 4 Sq.mm PVC FRLS insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 4 Sq.mm one run complete. Note: 2 run of 4 Sq.mm cable one run 4 Sq.mm earth wire with casing capping considered as one unit.
Taking down old existing sub main wiring and M&L for sub main wiring with 2 run single core 2.5 Sq.mm PVC FRLS insulated unsheathed copper multistranded conductor 1100 Volts grade drawing into and including PVC heavy duty casing and capping with PVC coated copper earth conductor 2.5 Sq.mm one run complete. Note: 2 run of 2.5 Sq.mm cable one run 2.5 Sq.mm earth wire with casing capping considered as one unit.
Taking down existing light fittings fixed in any description and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X020XC 20 W CCT 6500 or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
Taking down existing light fittings fixed in any description and S&F new 10 Watt wall mounted 2 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X010XC 10 W CCT 6500 or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
Taking down existing street light fittings of any type and S&F new LED street light 45 Watt in aluminium pressure die cast housing with touch glass cover (IP 66 protection) on walls /steel/concrete pole any height including connection from ceiling rose / Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor pvc insulated and pvc sheathed 1100 V grade any length fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Model No LED street light Cat No -LSRT01SO45XC CCT 6000K or an equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
S&F LED bollard light fitting 8W minimum IP65 protection cone series dia cast aluminium housing frosted PC diffuser, IP65 with in built LED fixed as per manufacturers instructions & testing on completion complete all as directed. Make: Havells Cat No CONEBL8WLED857SSYMTOPC or equivalent in Jaquar, Wipro , Bajaj
S&F in repairs electronic driver suitable for LED fittings of any type of make/ model of 9 to 19 Watt. Make: Philips /Osram /Jaquar /C&S /Bajaj /GE etc
S&F in repairs ceiling rose surface bakelite White / Ivory / Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F in repairs switch piano flush, single pole, one way 5 / 6 Amp complete all as directed. Make: Anchor / Standard / Leader/ Legrand
S&F in repairs switch socket outlet 3 Pin 6 Amp flush type complete all as directed. Make: Anchor / Standard / Leader /Legrand
S&F in repairs switch socket outlet multipurpose 3 Pin 16 Amp and 3 pin 6 Amp, 240 Volt, controlled by one switch complete all as directed. Make: Anchor / Standard / Leader /Legrand
S&F in repairs switch bell push, piano flush type, single pole, 6 Amp complete all as directed. Make: Anchor / Standard / Leader /Legrand
S&F in repairs bell AC 230 Volt Ding Dong type, 240 Volt AC supply complete all as directed. Make: Anchor / HPL / Rider/ Leader /Legrand
S&F in repairs switch modular type single pole one way 6 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 01 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs switch modular type single pole one way 16 Amp with all accessories complete all as directed. Make: Legrand Cat No. 6755 11 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet 3 Pin 6 Amp modular type all accessories complete all as directed. Make: Legrand Cat No. 6755 52 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs socket outlet multipurpose 2/3 Pin for 6 / 16 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 55 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs bell push 6 Amp modular type with all accessories complete all as directed. Make: Legrand Cat No. 6755 04 or equivalent in Philips / Crabtree / ABB / Havells
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB SPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No. 5076 10 or equivalent of Havells / L&T / ABB
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB SPN 8 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No. 5076 11 or equivalent of Havells / L&T / ABB
S&F in repairs epoxy powder coated sheet with metal door enclosures with 2 mm thick CRCA sheet for and including MCB DB TPN 4 way, 240 V with 200 Amp rated bus bar with double door locking system complete. Make: Legrand Cat No 5076 70 or equivalent of Havells / L&T / ABB
S&F for Single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one single pole MCB 20 Amps complete all as directed.
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 87 to 4085 95 / Havells / L&T / ABB
S&F in repairs MCB SPN 10 to 32 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 408612 to 408617 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SPN 40 to 63 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 408618 to 408620 or equivalent of Havells / L&T / ABB
S&F in repairs MCB TPN 6 to 32 Amp, 50 Hz, AC supply, 10 kA with proper size lugs. Make: Legrand Cat No. 408672 to 408680 or equivalent of Havells / L&T / ABB
S&F in repairs MCB TPN 40 to 63 Amp, 415 V, 50 Hz, AC supply. Make: Legrand Cat No. 408681 to 408683 or equivalent of Havells / L&T / ABB
M&L for casing and capping min 25 mm wide, double lock type in repairs by using existing wiring, for light point, fan point, bell point, PVC boards, good finishing for including screws, bolts nuts, drilling etc.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead GI wire 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead strip protected by Gl light grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, including taking down existing earthing complete all as specified including testing on completion.
Servicing, repair, maintenance and attending complaint/ faults to the Automitic Meter reading system excluding spares but including hardware maintenance and gerating/ printing of bills & updating of quarter holders data such as Qtr No., Name, Rank, Service No., Category and carrying out complete repairing, servicing, programming and maintenance as required to the panel consisting of master viz. PIC Microcontroller based single/ multiple meter monitoring module and its programming, replacement of unserviceable parts, refixing of old serviceable parts and new parts if any for the following locations:- P-490, P-491, P-493, P-494, P-495, P-496, P-497, P-437, P-438, P-439, P-440, P-423, P-425, P-77, P-78, P-120, P-154/1, P154/2, P-249, P-349, P-350, P-401, P-402, P-73, P-74, P-422/6, P-424/6, P-483/3, P-169, P-204, P-205, P-206, P-207, P-219, P-222, P-223, P-224, P-226, P-238, P-239, P-145, P-364, P-484, P-485, P-442, P-443, P-444, P-445, P-446, P-447, P-448, P-449, P-450, P-451, P-452, P-453, P-454, P-455, P-456, P-5, P-6, P-7, P-8, P-9, P-10, P-11, P-12, P-13, P-14, P-25, P-41, P-42, P-43, P-44, P-457
NOTES: (i) New spare required for day to day maintainence will be measured and paid separately under BOQ item Nos 44 to 49. (ii) Unit rate quoted of checking of system on dailly basis under relevant items herein after is in inclusive of and necessary serviceing, repair and the register shall be maintained to that effect. (iii) Attendant will report on dailly basis and record the requisite parameters including attend the complains. (iv) In addition to above specific emergency complaints from time to time shall be attended after receiving the same. (v) The scope of work includes the charges required for removing, repairing, refixing, carrying out elecrical termination and fixing/ installing, testing, commissioning etc. establishing PIC Microcontroller based single / multiple meter monitoring molule and its programming and all as dircted. (vi) Any additional spares other than mentioned in schedule, required for upgradation of system is the responsibility of contractor. No extra cost will be made on this account. Rate should be inclusive of such spares, if required.
Providing one year license charges for cloud based online Automatic Meter Reading and Billing Software suitable for 2000 meters including the following features. (a) Remote Monitoring and Reporting, (b) Billing, (c) email and alerts utility, (d) Meter reading shall be updated every 10 minutes (user settable), (e) Time stamp of last reading received. (with offline meter notification center), (f) Automatic bills generation at the end of period of category based consumers as directed by Engineer-in-Charge, (g) User settable billing format as directed by Engineer-in-Charge, (h) Facilitty to change/ add meter calculations of billing amount of bill generation of users at every end of specific period of category, (j) Monthly bills to be mailed to user if email ID of user exists in server, (k) Admin access can view and edit details of consumers, (l) Admin access can view periodic bills of any category of consumers and print them on demand, (m) Admin access can set consumer exit date of living quarter for generating manual bill of specific time period of consumer, (n) Supports common meter of building and calculate the amount of common meter energy charges will be distributed to all active consumers of that building.
Supply, install, activation of new SIM cards including taking down old expired SIM cards from GPRS system.
Recharges of new SIM cards GPRS enabled for 115 SIM Cards on monthly basis.
Augmenation/ Modification of existing PIC Microcontroller based single/ multiple meter monitoring module, Operating Voltage:230V AC, Circuit Voltage 12V DC for incusion of common meter connection in every panel boards installed complete all as directed.
Supply of data storage charges for storing meter details and billing data per meter for a period of 11 Months to cloud server. Make: Amazon, Google Cloud, Microsoft Azure.
Supply only external antenna for GPRS modem gain 9db for transmitting and receiving data and from server. Make RDS/ Hitch Nick Auomation
Supply only Switched mode power supply/ Voltage Converter for valtage supply to PIC circuit: 230V AC to 12 V DC current. Make RDS/ Hitch Nick Auomation
Supply only PIC Microcontroller based single/ multiple meter monitoring module Operating Voltage 230V AC, Circuit Voltage 12 V DC. Make RDS/ Hitch Nick Auomation
Supply only Pickup Phototransistor used for sensing the blinking of LED on digital electrical meter. Make RDS/ Hitch Nick Auomation
Supply only Communication modem between module and control centre (server) MQTT or HTTP over GPRS protocol. Make RDS/ Hitch Nick Auomation
S&F cable 4 core PVC insulated unsheathed multistranded copper conductor of size 0.75 sqmm including suitable casing caping / PVC condiut etc. Make: Havells, Finolex, L&T, V-Guard, KEI.
S&F in repairs master panel box including LED indication on display from front side of panel all as directed. Make RDS/ Hitch Nick Auomation
Taking down old u/s single phase AC 230V energy meter from site and fixing new single phase AC 230V issued by the department complete all as directed by Engineer-in-Charge. Note: Old meter is property of MES & the same to be deposited to MES E/M Store without any extra cost to Govt.
M/s Balaji Enterprise
Hirachand Sunderji and co
suvidhiconstruction
Ravi enterprise
M/S Badri Electicals
Prime Decor
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .