Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹71.9 L
EMD Value
₹71,944
Closing Date
14 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Chief Officer, Chorwad Nagarpalika, Chorwad
RFP for Development of Solid Waste Processing Plant for Dry and Wet Waste Generated by the ULBs Under SBM Urban 2.0 on Design, Build, Operate and Transfer Basis (Third Attempt) Name of ULB-Chorvad, Zone:-Bhavnagar
367955
T119a-RX07
Open
Civil Works
Works
Junagadh
14 documents required · 13 mandatory · 1 optional
₹2,400
Chief Officer, Chorwad Nagarpalika, Chorwad
₹71,944
23 Nov 2026
23 Nov 2026
23 Nov 2026
14 Dec 2026
23 Nov 2026
120 days
S. No. Total Amount in Lacs
Total Estimated Cost
Abstract sheet Waste Receiving Platform ( 7x7 m)
SOR Particulars Quantity Rate Amount Total
Sl. No Item no Unit L.C.@1%
Reference (M) (Rs.) (Rs.) Amount
Upto plinth level
Excavation for foundation upto 1.5 m depth
SOR including sorting out and stacking of useful
1 04B001A materials and disposing off the excavated stuff
district - upto 50 Meter lead.(A) Loose or soft soi
All kinds of soil
Filling available excavated earth (excluding rock)
in trenches. plinth, sides of foundations etc. in
2 4006 layers not exceeding 20 cm. in depth
consolidating each disposited layer by ramming
For PCC below footing Cum
For Footing Cum
SOR Filling in foundation and plinth with murrum or
Junagadh selected soil in layers of 20cm. thickness
district including watering, ramming and consolidating
(2023-24) etc. complete. cum
CEMENT CONCRETE :-
Providing and laying in position cement concrete
of specified grade excluding the cost of
centering and shuttering - All work up to plinth
Providing and laying cement concrete 1:3:6 (1-
SOR Cement : 3- coarse sand : 6- hand broken stone
Junagadh aggregates 40 mmnominal size) and curing
district complete excluding cost of formwork in (A)
(2023-24) Foundation and Plinth
Below footing Cum
Below Plinth beam Cum
Below Plinth beam Cum
Providing formwork of ordinary timber planking
so as to give a rough finish including centering
shuttering strutting and propping etc. Height of
SOR propping and centering below supporting floor Sqm
09001AA to ceiling not exceeding 4 M. and removal of the Sqm
district same for in situ reinforced concrete and plain Sqm
(2023-24) concrete work in. (A) Foundations Footings
Bases of Columns etc. and Mass concrete. Sqm
Providing formwork of ordinary timber planking
so as to give a rough finish including centering
shuttering strutting and propping etc. height of
SOR propping and centering below supporting floor
Junagadh to ceiling not exceeding 4 M. and removal of the
District same for in situ reinforced concrete and plain
(2023-24) concrete work in. (H) (2) Sides and soffits of
Beams Beam Haunchings canti-levers Girders
Bressumers and Lintels exceeding 1M.in Depth.
Plinth beam Sqm
Plinth beam Sqm
REINFORCED CEMENT CONCRETE
Providing and laying controlled cement concrete
SOR M.200 and curing complete excluding the cost of
Junagadh formwork and reinforcement for reinforced
05024CA concrete work in (C)
(2023-24) Slabs,landing,shelves,Balconies Lintels, Beams,
Girders and Cantilever upto floor two level.
For footing Cum
For Column upto plinth level Cum
Plinth beam Cum
Plinth beam Cum
REINFORCEMENT :-
SOR Providing TMT Bar FE 500D reinforcement for
Junagadh R.C.C. work including bending, binding and
05014C placing in position complete upto floor two level
Thermo-Mechanically Treated bars of grade Fe-
For footing 10Ø @ 150mm C/C bothway
For column 8 nos 12Ø
Stirrup 8Ø @ 150mm C/C
For Plinth beam 8 nos 12Ø
For Plinth beam 8 nos 12Ø
Stirrup 8Ø @ 150mm C/C For Plinth beam
Stirrup 8Ø @ 150mm C/C Plinth beam
top beam 8 nos 12Ø kg
Providing and laying cement concrete 1:3:6 (1-
SOR Cement : 3- coarse sand : 6- hand broken stone
Junagadh aggregates 40 mmnominal size) and curing
district complete excluding cost of formwork in (A)
(2023-24) Foundation and Plinth
Below floor slab cum
Providing and laying controlled cement concrete
SOR M.200 and curing complete excluding the cost of
Junagadh formwork and reinforcement for reinforced
10 05024CA concrete work in (C) Cum
(2023-24) Slabs,landing,shelves,Balconies Lintels, Beams,
Girders and Cantilever upto floor two level
White Stone Bela mesonry block in course in
superstructure with stone of approved
11 quality in Lime Mortar 1:5 (1-Cement :5-
(2023-24) course sand) including packing the joints
Providing 15mm thick cement plaster in single
SOR coat on Rough (Similar)side of single or half
district walls for interior plastering upto floor two level
(2023-24) and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand)
SOR Providing TMT Bar FE 500D reinforcement for
Junagadh R.C.C. work including bending, binding and
district placing in position complete upto floor two level
Thermo-Mechanically Treated bars of grade Fe-
For slab 10mm@150mm c/c
Measurement sheet Waste Receiving Platform ( 7x7 m)
Sl. SOR Particulars Length Breadth/Width Depth/ Quantity
Item no Unit Nos
No Reference (M) (M) Height (M) (M)
Upto plinth level
Excavation for foundation upto 1.5 m depth
SOR including sorting out and stacking of useful
Junagadh materials and disposing off the excavated stuff
district - upto 50 Meter lead.(A) Loose or soft soi
All kinds of soil
Footing Cum 8.00 1.45 1.45 2.00
Filling available excavated earth (excluding rock)
in trenches. plinth, sides of foundations etc. in
2 4006 layers not exceeding 20 cm. in depth
consolidating each disposited layer by ramming
For PCC below footing Cum 8.00 1.45 1.45 0.10
For Footing Cum 8.00 1.25 1.25 0.30
For Column Cum 8.00 0.45 0.45 1.60
Total(I-II) (Cum):-
SOR Filling in foundation and plinth with murrum or
Junagadh selected soil in layers of 20cm. thickness
district including watering, ramming and consolidating
column cum 4.00 0.45 0.23 0.65
CEMENT CONCRETE :-
Providing and laying in position cement concrete
of specified grade excluding the cost of centering
and shuttering - All work up to plinth level :
Providing and laying cement concrete 1:3:6 (1-
SOR Cement : 3- coarse sand : 6- hand broken stone
Junagadh aggregates 40 mmnominal size) and curing
district complete excluding cost of formwork in (A)
(2023-24) Foundation and Plinth
Below footing Cum 8.00 1.45 1.45 0.10
Below Plinth beam Cum 4.00 2.30 0.45 0.10
Below Plinth beam Cum 4.00 2.30 0.45 0.10
Providing formwork of ordinary timber planking
so as to give a rough finish including centering
shuttering strutting and propping etc. Height of
SOR propping and centering below supporting floor to Sqm 2x8 1.25 0.30
09001AA ceiling not exceeding 4 M. and removal of the Sqm 2x8 1.25 0.30
district same for in situ reinforced concrete and plain Sqm 2x8 0.45 2.45
(2023-24) concrete work in. (A) Foundations Footings Bases
of Columns etc. and Mass concrete. Sqm 2x8 0.45 2.45
Providing formwork of ordinary timber planking
so as to give a rough finish including centering
shuttering strutting and propping etc. height of
SOR propping and centering below supporting floor to
Junagadh ceiling not exceeding 4 M. and removal of the
District same for in situ reinforced concrete and plain
(2023-24) concrete work in. (H) (2) Sides and soffits of
Beams Beam Haunchings canti-levers Girders
Bressumers and Lintels exceeding 1M.in Depth.
Plinth beam Sqm 4.00 2.30 1.35
Plinth beam Sqm 4.00 2.30 1.35
REINFORCED CEMENT CONCRETE
Providing and laying controlled cement concrete
SOR M.200 and curing complete excluding the cost of
Junagadh formwork and reinforcement for reinforced
05024CA concrete work in (C)
(2023-24) Slabs,landing,shelves,Balconies Lintels, Beams,
Girders and Cantilever upto floor two level.
For footing Cum 8.00 1.25 1.25 0.30
For Column upto plinth level Cum 8.00 0.45 0.45 2.45
Plinth beam Cum 4.00 2.30 0.45 0.45
Plinth beam Cum 4.00 2.30 0.45 0.45
top beam cum 8.00 2.30 0.45 0.45
REINFORCEMENT :-
SOR Providing TMT Bar FE 500D reinforcement for
Junagadh R.C.C. work including bending, binding and
05014C placing in position complete upto floor two level
Thermo-Mechanically Treated bars of grade Fe-
For footing 10Ø @ 150mm C/C bothway
For column 8 nos 12Ø
Stirrup 8Ø @ 150mm C/C
For Plinth beam 8 nos 12Ø
For Plinth beam 8 nos 12Ø
Stirrup 8Ø @ 150mm C/C For Plinth beam
Stirrup 8Ø @ 150mm C/C Plinth beam
top beam 8 nos 12Ø kg
Providing and laying cement concrete 1:3:6 (1-
SOR Cement : 3- coarse sand : 6- hand broken stone
Junagadh aggregates 40 mmnominal size) and curing
district complete excluding cost of formwork in (A)
(2023-24) Foundation and Plinth
Below floor slab cum 1.00 7.00 7.00 0.15
column cum 4.00 0.45 0.23 1.15
Providing and laying controlled cement concrete
SOR M.200 and curing complete excluding the cost of
Junagadh formwork and reinforcement for reinforced
10 05024CA concrete work in (C) Cum 1.00 7.00 7.00 0.20
(2023-24) Slabs,landing,shelves,Balconies Lintels, Beams,
Girders and Cantilever upto floor two level
column cum 4.00 0.45 0.23 2.00
White Stone Bela mesonry block in course in
superstructure with stone of approved
11 quality in Lime Mortar 1:5 (1-Cement :5-
(2023-24) course sand) including packing the joints etc.
SOR Providing 15mm thick cement plaster in single
Junagadh coat on Rough (Similar)side of single or half brick
district walls for interior plastering upto floor two level
(2023-24) and finished even and smooth in (ii) Cement
mortar 1:4 (1-cement :4-sand)
SOR Providing TMT Bar FE 500D reinforcement for
Junagadh R.C.C. work including bending, binding and
district placing in position complete upto floor two level
Thermo-Mechanically Treated bars of grade Fe-
For slab 10mm@150mm c/c
Abstract sheet R.C.C. ROAD
Sr. SOR Item Qty. Unit Amount (Rs.) Total
No Reference Code L.C.@1% Amount
Box cutting the road surface to proper slope and camber
for making a base for road work including removing the
Junagadh excavated stuff and deposing on the road slope as
1 District 26008 directed upto 50 mt. lead. 180.00 Cum. 103.17
Spreading blindage or road crust filling the gaps in metal
2 District 26020A 180.000 CUM
and leveling to camber and gradient as 26,281.80
directed.(i) Murrum
Providing and laying cement concrete 1:3:6 (1-cement:3-
coarse sand:6-hand broken stone aggreates 40mm
Junagadh nominal size) and curing completed excluding cost of
3 District 5003A foramwork in (A) foundation and plinth (upto 10 ton)
(a) Foundation and plinth. 60.00 Cum.
Providing and laying ordinary cement concrete 1:2:4 (1-
cement: 2-coarse sand: 4-graded stone aggregates 20mm
nominal size) and finishing smooth with, curing etc.
Junagadh completed excluding the cost of formwork in (A)
4 District 05010AA foundation and plinth (upto 10 ton) 120.00 Cum. 3661.30
Providing TMT bar FE 415 reinforcement for RCC work
Junagadh including bending, binding and placing in position
5 District 05014BA completed upto floor two level (more than 10 ton) 600.00 Kg 66.59
Total rate 120 running meter
NAME OF WORK ::- R.C.C. ROAD
Box cutting the road surface to proper slope and camber for making a base for road work including
removing the excavated stuff and deposing on the road slope as directed upto 50 mt. lead.
Total 180.000 Cum.
SAY.. 180.000 Cum.
Spreading blindage or road crust filling the gaps in metal and leveling to camber and gradient as
directed.(i) Murrum
Total 180.000 Cum.
SAY.. 180.000 Cum.
Providing and laying cement concrete 1:3:6 (1-cement:3-coarse sand:6-hand broken stone aggreates
40mm nominal size) and curing completed excluding cost of foramwork in (A) foundation and plinth (upto
(a) Foundation and plinth.
Total 60.000 Cum.
SAY.. 60.000 Cum.
Providing and laying ordinary cement concrete 1:2:4 (1-cement: 2-coarse sand: 4-graded stone aggregates
20mm nominal size) and finishing smooth with, curing etc. completed excluding the cost of formwork in
(A) foundation and plinth (upto 10 ton)
(a) Foundation and footings
Total 120.000 Cum.
SAY.. 120.000 Cum.
Providing TMT bars FE-415 reinforcement for RCC work including bending, binding and placing in position
complete upto floor two level
Reinforcement considered 25 kg 120.000 25 3000 kg
per 1 Cum. Cement Concrete
Name of structure :- Detail Estimate of Construction of Processing shed (20 *10 M)
Quantity Amount
Sl. No Item no Particulars Unit
L.C.@1% Total Amount
L.C.@1% Total Amount
Upto Plinth Level :-
SOR CODE EARTH WORK :-
Junagadh Excavation for foundation upto 1.5 m depth
District including sorting out and stacking of useful
SOR -2023- materials and disposing off the excavated
24 stuff upto 50 Meter lead.(A) Loose or soft soi
All kinds of soil
Excavation for foundation for depth
from 1.5 m to 3.0 m including sorting out and
2.00 04B002A stacking of useful materials and disposing off
the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Filling available excavated earth
(excluding rock) in trenches. plinth, sides of
3.00 04006 foundations etc. in layers not exceeding
cm. in depth consolidating each disposited
layer by ramming and watering.
For PCC below footing Cum
For Footing Cum
Junagadh Filling in foundation and plinth with murrum
District or selected soil in layers of 20cm. thickness
SOR -2023- including watering, ramming and
24 consolidating etc. complete.
bela stone wall cum
plinth beam cum
CEMENT CONCRETE :-
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
Junagadh Providing and laying cement concrete 1:3:6
District (1- Cement : 3- Coarse sand : 6- crushed stone
SOR -2023- aggregates 20 mm nominal size) and curing
24 complete including cost of formwork in
Below footing Cum
Below Plinth beam Cum
Below Plinth beam Cum
Below floor cum
6.00 FORM WORK :-
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping Sqm
etc. Height of propping and centering below
09001AA supporting floor to ceiling not exceeding 4 M.
and removal of the same for in situ reinforced
concrete and plain concrete work in. (A)
Foundations Footings Bases of Columns etc. Sqm
and Mass concrete.
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
Junagadh etc. height of propping and centering below
District supporting floor to ceiling not exceeding 4 M.
SOR -2023- and removal of the same for in situ reinforced
24 concrete and plain concrete work in. (H) (2)
Sides and soffits of Beams Beam Haunchings
canti-levers Girders Bressumers and Lintels
exceeding 1M.in Depth.
Plinth beam Sqm
Plinth beam Sqm
White Stone Bela mesonry block in
SOR course in superstructure with stone
Junagadh of approved quality in Lime Mortar
(2023-24) 1:5 (1-Cement :5- course sand)
including packing the joints etc.
07010A complete.
SOR Providing 15mm thick cement plaster in
Junagadh single coat on Rough (Similar)side of single or
9.00 17002A half brick
(2023-24) walls for interior plastering upto floor two
level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)
REINFORCED CEMENT CONCRETE
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
10.00 05024CA reinforcement for reinforced concrete work in
(C) Slabs,landing,shelves,Balconies Lintels,
Beams, Girders and Cantilever upto floor two
For footing Cum
For Column upto plinth level Cum
Plinth beam Cum
Plinth beam Cum
REINFORCEMENT :-
Junagadh Providing TMT Bar FE 500D reinforcement for
District R.C.C. work including bending, binding and
SOR -2023- placing in position complete upto floor two
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For footing 10Ø @ 150mm C/C bothway
For column 8 nos 16 Ø
Stirrup 8Ø @ 150mm C/C
For Plinth beam 8 nos 12 Ø
For Plinth beam 8 nos 12 Ø
Stirrup 8Ø @ 150mm C/C For Plinth beam
Stirrup 8Ø @ 150mm C/C Plinth beam
Above Plinth Level :-
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
etc. height of propping and centering below
12.00 09001G1A supporting floor to ceiling not exceeding 4 M.
and removal of the same for in situ reinforced
concrete and plain concrete work in. (G)
Columns PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan.
Columns, Pillars, Piers, Abutments, Posts and
REINFORCED CEMENT CONCRETE :-
Providing and laying controlled cement
Junagadh concrete M.250 and curing complete
District excluding the cost of formwork and
SOR -2023- reinforcement for reinforced concrete work in
24 (A) Foundations, footings, Base of columns
and Mass concrete
REINFORCEMENT :-
Junagadh Steel reinforcement for R.C.C. work including
District straightening, cutting, bending, placing in
SOR -2023- position and binding all complete above
24 plinth level.
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For column 8 nos 16Ø
Stirrup 8Ø @ 150mm C/C
floor slab 10Ø @ 150mm C/C
Providing 15mm thick cement plaster in single
coat on Rough (Similar)side of single or half
15.00 17002B brick walls for interior plastering upto floor
two level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
16.00 05024CA reinforcement for reinforced concrete work in Cum
(C) Slabs,landing,shelves,Balconies Lintels,
Beams, Girders and Cantilever upto floor two
Providing corrugated G.I. sheet of class-3
Junagadh fixed with glavanished iron J or L Hooks, Bolts
District and nuts 8mm diameter with bitumen and
SOR -2023- G.I. limpet washer or G.I. limpet washer. filled
24 with white lead complete excluding the cost
of purlins, Rafters and Trusses.(1) 0.80 mm
Providing ridges or hips 600 mm overall in
plain G.I. sheet class-3 fixed with G.I.J. or L
18.00 15002A Hooks and nuts 8mm dia G.I. Limpet and
bitumen washer complete. (1) 0.80 mm thick
0.63 mm thick with zinc coating not less than
19.00 Chicken wire mesh 16 x24 Sqm
Sl. No Item no Particulars Unit Quantity
Steel work, riveted in built up sections framed
work including cutting, hoisting, fixing in
20.00 11001DA position and applying a priming coat of red Kg
lead paint. (D) In trussses and trussed purlins,
upto 25 M. span and 15 M ovarall height.
Steel work, welded in built up sections
framed work including cutting, hoisting, fixing
21.00 11002DA in position and applying a priming coat of red
lead paint. (D) In trussses and trussed purlins,
upto 25 M. span and 15 M. ovarall height.
Electric resistance or induction butt welded
tubes (RHS-150 X 30 X 3 mm)
For king post truss
RHS 100 x 50 x 2 mm Kg
Measurement Sheet
Name of structure: - Detail Estimate of Construction of MRF shed (20 *10 M)
Length Breadth/Width Depth/ Quantity
Sl. No Item no Particulars Unit Nos
(M) (M) Height (M) (M)
Upto Plinth Level :-
SOR CODE EARTH WORK :-
Junagadh Excavation for foundation upto 1.5 m depth
District including sorting out and stacking of useful
SOR -2023- materials and disposing off the excavated
24 stuff upto 50 Meter lead.(A) Loose or soft soi
All kinds of soil
Footing Cum 10.00 1.45 1.45 1.50
Excavation for foundation for depth
from 1.5 m to 3.0 m including sorting out and
2.00 04B002A stacking of useful materials and disposing off
the excavated stuff upto 50 Meter lead.(A)
Loose or soft soil
Footing cum 10.00 1.45 1.45 0.50
Filling available excavated earth
(excluding rock) in trenches. plinth, sides of
3.00 04006 foundations etc. in layers not exceeding
cm. in depth consolidating each disposited
layer by ramming and watering.
For PCC below footing Cum 10.00 1.45 1.45 0.10
For Footing Cum 10.00 1.25 1.25 0.30
For Column Cum 10.00 0.45 0.60 1.60
Total(I-II) (Cum):-
Junagadh Filling in foundation and plinth with murrum
District or selected soil in layers of 20cm. thickness
SOR -2023- including watering, ramming and
24 consolidating etc. complete.
bela stone wall cum 1.00 60.00 0.125 0.30
plinth beam cum 1.00 60.00 0.225 0.20
CEMENT CONCRETE :-
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
Junagadh Providing and laying cement concrete 1:3:6
District (1- Cement : 3- Coarse sand : 6- crushed stone
SOR -2023- aggregates 20 mm nominal size) and curing
24 complete including cost of formwork in
Below footing Cum 10.00 1.46 1.46 0.10
Below Plinth beam Cum 8.00 5.00 0.45 0.10
Below Plinth beam Cum 1.00 20.00 0.45 0.10
Below floor cum 1.00 20.00 10.00 0.10
6.00 FORM WORK :-
Junagadh Providing formwork of ordinary timber
District planking so as to give a rough finish including
SOR -2023- centering shuttering strutting and propping Sqm 2 x 10 1.25 0.30
24 etc. Height of propping and centering below Sqm 2 x 10 1.25 0.30
supporting floor to ceiling not exceeding 4 M. Sqm 2 x 10 0.45 2.10
and removal of the same for in situ reinforced
concrete and plain concrete work in. (A)
Foundations Footings Bases of Columns etc.
and Mass concrete.
floor sqm 1.00 60.00 0.20
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
Junagadh etc. height of propping and centering below
District supporting floor to ceiling not exceeding 4 M.
SOR -2023- and removal of the same for in situ reinforced
24 concrete and plain concrete work in. (H) (2)
Sides and soffits of Beams Beam Haunchings
canti-levers Girders Bressumers and Lintels
exceeding 1M.in Depth.
Plinth beam Sqm 8.00 5.00 1.65
Plinth beam Sqm 1.00 20.00 1.65
White Stone Bela mesonry block in
SOR course in superstructure with stone
Junagadh of approved quality in Lime Mortar
(2023-24) 1:5 (1-Cement :5- course sand)
including packing the joints etc.
07010A complete.
PLASTERING total
SOR Providing 15mm thick cement plaster in
Junagadh single coat on Rough (Similar)side of single or
9.00 17002A half brick
(2023-24) walls for interior plastering upto floor two
level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)
stone work sqm 4.00 20.00 0.30
REINFORCED CEMENT CONCRETE
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
10.00 05024CA reinforcement for reinforced concrete work in
(C) Slabs,landing,shelves,Balconies Lintels,
Beams, Girders and Cantilever upto floor two
For footing Cum 10.00 1.25 1.25 0.30
For Column upto plinth level Cum 10.00 0.45 0.60 2.10
Plinth beam Cum 8.00 5.00 0.45 0.60
Plinth beam Cum 2.00 10.00 0.45 0.60
REINFORCEMENT :-
Junagadh Providing TMT Bar FE 500D reinforcement for
District R.C.C. work including bending, binding and
SOR -2023- placing in position complete upto floor two
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For footing 10Ø @ 150mm C/C bothway
For column 8 nos 16 Ø
Stirrup 8Ø @ 150mm C/C
For Plinth beam 8 nos 12 Ø
For Plinth beam 8 nos 12 Ø
Stirrup 8Ø @ 150mm C/C For Plinth beam
Stirrup 8Ø @ 150mm C/C Plinth beam
Above Plinth Level :-
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
etc. height of propping and centering below
12.00 09001G1A supporting floor to ceiling not exceeding 4 M.
and removal of the same for in situ reinforced
concrete and plain concrete work in. (G)
Columns PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan.
Columns, Pillars, Piers, Abutments, Posts and
Column Sqm 2 x 10 0.45 5.00
REINFORCED CEMENT CONCRETE :-
Providing and laying controlled cement
Junagadh concrete M.250 and curing complete
District excluding the cost of formwork and
SOR -2023- reinforcement for reinforced concrete work in
24 (A) Foundations, footings, Base of columns
and Mass concrete
For column Cum 10.00 0.45 0.60 5.00
REINFORCEMENT :-
Junagadh Steel reinforcement for R.C.C. work including
District straightening, cutting, bending, placing in
SOR -2023- position and binding all complete above
24 plinth level.
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For column 8 nos 16Ø
Stirrup 8Ø @ 150mm C/C
floor slab 10Ø @ 150mm C/C
Providing 15mm thick cement plaster in single
coat on Rough (Similar)side of single or half
15.00 17002B brick walls for interior plastering upto floor
two level and finished even and smooth in (ii)
Cement mortar 1:4 (1-cement :4-sand)
Providing and laying controlled cement
concrete M.200 and curing complete
excluding the cost of formwork and
16.00 05024CA reinforcement for reinforced concrete work in Cum 1.00 20.00 10.00 0.20
(C) Slabs,landing,shelves,Balconies Lintels,
Beams, Girders and Cantilever upto floor two
Providing corrugated G.I. sheet of class-3
Junagadh fixed with glavanished iron J or L Hooks, Bolts
District and nuts 8mm diameter with bitumen and
SOR -2023- G.I. limpet washer or G.I. limpet washer. filled
24 with white lead complete excluding the cost
of purlins, Rafters and Trusses.(1) 0.80 mm
On roof Sqm 2.00 5.50 20.30
Providing ridges or hips 600 mm overall in
plain G.I. sheet class-3 fixed with G.I.J. or L
18.00 15002A Hooks and nuts 8mm dia G.I. Limpet and
bitumen washer complete. (1) 0.80 mm thick
0.63 mm thick with zinc coating not less than
Metre 1.00 21.00
Total (Meter):-
19.00 Chicken wire mesh 16 x24 Sqm 2x2 10.20 0.30
Length Total length Unit
Sl. No Item no Particulars Unit Nos Quantity
(M) (M) Weight(Kg/M)
Steel work, riveted in built up sections framed
work including cutting, hoisting, fixing in
20.00 11001DA position and applying a priming coat of red Kg 5.00 10.00 50.00 6.82
lead paint. (D) In trussses and trussed purlins,
upto 25 M. span and 15 M ovarall height.
Steel work, welded in built up sections
framed work including cutting, hoisting, fixing
21.00 11002DA in position and applying a priming coat of red
lead paint. (D) In trussses and trussed purlins,
upto 25 M. span and 15 M. ovarall height.
Electric resistance or induction butt welded
tubes (RHS-150 X 30 X 3 mm)
For king post truss
King post Kg 5.00 3.00 15.00 8.07
Abstract sheet of Recyclable Storage & Compost Storage (12x6 sqm)
Quantity Rate Amount
Sl. No Item no Unit L.C.@1% Total Amount
Sl. No Item no Unit L.C.@1% Total Amount
Upto plinth level
SOR Excavation for foundation upto 1.5 m depth
Junagadh including sorting out and stacking of useful
1.00 District - 04B001A materials and disposing off the excavated
(2023- stuff upto 50 Meter lead.(A) Loose or soft soil
All kinds of soil
SOR Filling available excavated earth (excluding
Junagadh rock) in trenches. plinth, sides of foundations
2.00 District - etc. in layers not exceeding 20 cm. in depth
(2023- consolidating each disposited layer by
24) 04006 ramming and watering.
For PCC below footing Cum
For Footing Cum
Filling in foundation and plinth with murrum
or selected soil in layers of 20cm. thickness
including watering, ramming and
consolidating etc. complete.
4.00 CEMENT CONCRETE :-
Providing and laying in position cement
concrete of specified grade excluding the cost
of centering and shuttering - All work up to
SOR Providing and laying cement concrete 1:3:6 (1-
Junagadh Cement : 3- coarse sand : 6- hand broken
District - 05003A stone aggregates 40 mmnominal size) and
(2023- curing complete excluding cost of formwork in
24) (A) Foundation and Plinth
Below footing Cum
Below Plinth beam Cum
Below Plinth beam Cum
5.00 FORM WORK :-
Providing formwork of ordinary timber
planking so as to give a rough finish including
SOR centering shuttering strutting and propping
Junagadh etc. Height of propping and centering below Sqm
District - 09001AA supporting floor to ceiling not exceeding 4 M. Sqm
(2023- and removal of the same for in situ reinforced Sqm
24) concrete and plain concrete work in. (A)
Foundations Footings Bases of Columns etc. Sqm
and Mass concrete.
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M.
District - 09001H2A
and removal of the same for in situ reinforced
concrete and plain concrete work in. (H) (2)
Sides and soffits of Beams Beam Haunchings
canti-levers Girders Bressumers and Lintels
6.00 exceeding 1M.in Depth.
Plinth beam Sqm
Plinth beam Sqm
5.00 REINFORCED CEMENT CONCRETE
Providing and laying controlled cement
SOR concrete M.200 and curing complete
Junagadh excluding the cost of formwork and
District - 05024CA reinforcement for reinforced concrete work in
(2023- (C) Slabs,landing,shelves,Balconies Lintels,
24) Beams, Girders and Cantilever upto floor two
For footing Cum
For Column upto plinth level Cum
Plinth beam Cum
Plinth beam Cum
8.00 REINFORCEMENT :-
SOR Providing TMT Bar FE 500D reinforcement for
Junagadh R.C.C. work including bending, binding and
District - 05014C placing in position complete upto floor two
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For footing 10Ø @ 150mm C/C bothway
For column 8 nos 16Ø
Stirrup 8Ø @ 150mm C/C
For Plinth beam 8 nos 12Ø
For Plinth beam 8 nos 12Ø
Stirrup 8Ø @ 150mm C/C For Plinth beam
Stirrup 8Ø @ 150mm C/C Plinth beam
Above Plinth Level :-
Cement Concrete Work
SOR Providing and laying cement concrete 1:3:6 (1-
Junagadh Cement : 3- coarse sand : 6- hand broken
District - stone aggregates 40 mmnominal size) and
(2023- curing complete excluding cost of formwork in
9.00 24) 05003A (A) Foundation and Plinth
Below floor slab cum 7.20 2976.00 21427.20 214.27
10.00 FORM WORK :-
Providing formwork of ordinary timber
planking so as to give a rough finish including
SOR centering shuttering strutting and propping
Junagadh etc. height of propping and centering below
District - 09001G1A supporting floor to ceiling not exceeding 4 M.
(2023- and removal of the same for in situ reinforced
24) concrete and plain concrete work in. (G)
Columns PillarsPosts and struts. (1) Square
Rectangular Polygonal in plan.
Columns, Pillars, Piers, Abutments, Posts and
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
etc. Height of propping and centering below
supporting floor to ceiling not exceeding 4 M.
District - 09001B2A
and removal of the same for in situ reinforced
concrete and plain concrete work in. (B) Flat
surfaces such as soffits of suspended floor
roof slabs Landings and the like. (2) Floors etc.
11.00 above 200mm in thickness.
Providing formwork of ordinary timber
planking so as to give a rough finish including
centering shuttering strutting and propping
etc. height of propping and centering below
supporting floor to ceiling not exceeding 4 M.
12.00 District - 09001H2A
and removal of the same for in situ reinforced
concrete and plain concrete work in. (H) (2)
Sides and soffits of Beams Beam Haunchings
canti-levers Girders Bressumers and Lintels
exceeding 1M.in Depth.
REINFORCED CEMENT CONCRETE
Providing and laying controlled cement
SOR concrete M.200 and curing complete
Junagadh excluding the cost of formwork and
13.00 District - 05024CA reinforcement for reinforced concrete work in
(2023- (C) Slabs,landing,shelves,Balconies Lintels,
24) Beams, Girders and Cantilever upto floor two
Lintel Beam cum
14.00 REINFORCEMENT :-
SOR Steel reinforcement for R.C.C. work including
Junagadh straightening, cutting, bending, placing in
District - 05014C position and binding all complete above plinth
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For floor slab 10mm@150mm c/c
For column 8 nos 16Ø
Stirrup 8Ø @ 150mm C/C
Lintel Beam 4 nos 12mm kg
15.00 FLOORING :-
Providing and laying controlled cement
SOR concrete M.200 and curing complete
Junagadh excluding the cost of formwork and
District - 05024CA reinforcement for reinforced concrete work in Cum
(2023- (C) Slabs,landing,shelves,Balconies Lintels,
24) Beams, Girders and Cantilever upto floor two
White Stone Bela mesonry block in course
superstructure with stone of approved
quality in Lime Mortar 1:5 (1-Cement :5-
24) course sand) including packing the joints
16.00 07010A etc. complete cum
Providing 15mm thick cement plaster in
single coat on Rough (Similar)side of single or
District - 17002B
walls for interior plastering upto floor two
level and finished even and smooth in (ii)
17.00 Cement mortar 1:4 (1-cement :4-sand) sqm
Providing and laying controlled cement
SOR concrete M.200 and curing complete
Junagadh excluding the cost of formwork and
18.00 District - 05024CA reinforcement for reinforced concrete work in
(2023- (C) Slabs,landing,shelves,Balconies Lintels,
24) Beams, Girders and Cantilever upto floor two
SOR Providing TMT Bar FE 500D reinforcement for
Junagadh R.C.C. work including bending, binding and
District - 05014C placing in position complete upto floor two
Thermo-Mechanically Treated bars of grade
Fe-500D or more
For Beam 8 nos 16Ø kg
For Beam 8 nos 16Ø kg
For slab 10mm@150mm c/c
Providing and fixing M.S. Grills of required
pattern to wooden frames of window etc.
with m.s. flats at required specings and frame
20.00 District - 10025AA
alround square or round bars with round
hended bolts and nuts or by screws (A) Plain
Grill (P.No. 82/Code No. 10025AA/It.No. 10.1)
Wall painting (two coats) with plastic
emulsion paint of approved brand and
manufacture on undecorated wall surface to
give an even shade including throughly
21.00 District -
brushing the surface free from mortar
droppings and other foreign matter and sand
papered smooth. (P.No. 133/Code No.
Same Qty. As Per Item No.
Applying priming coat of over new steel and
other metal surface after and including
preparing the surface by thoroughly cleaning,
oil grease, dirt and other foreign mater and
22.00 District -
scoured with brushes fine steel wool, scrapers
and sand paper with ready mixed priming
paint brushing red le (P.No. 134/Code No.
Same Qty. As Per Item No.
Painting two coats (excluding priming coat) on
SOR new steel and other metal surface with
Junagadh enamel paint, brusing interior to give an even
23.00 District - 19002 shade including cleaning the surface an even
(2023- shade including cleaning the surface of all dirt,
24) dust and other foreign matter. (P.No.
134/Code No. 19002/I.No. 19.7)
Same Qty. As Per Item No.
Providing and fixing rolling shutters of
approved make made of 80 mm wide M.S.
laths inter-locked together through their
entire length and jointed together at the ends
by end locks mounted on specially designed
24.00 District - 11005B
pipe shaft with bracket plates, guide channels
and arragements for inside and outside
locking with push-pull operation including the
cost of hood cover and spring etc. complete.
(B) Shutters having width 3.5 M. and above
Providing and fixing standared extruded of
alluminium section of size 63mm x 38.10mm
x 1.2mm , @ Wt. 0.643 Kg/mt with colour
25.00 District -
Powder Coated alluminium frame for
ventilation with 5 mm thick frosted glass as
details etc complete for Ventilation sqm 2.54 1163.92 2950.54 29.51
Measurement sheet of Recyclable Storage & Compost Storage (12x6 sqm)
Particulars Depth/
Length Breadth/Width Quantity
Sl. No Item no Unit Nos Height
Upto plinth level
SOR Excavation for foundation upto 1.5 m depth including
Junagadh sorting out and stacking of useful materials and disposing
1.00 District - 04B001A off the excavated stuff upto 50 Meter lead.(A) Loose or
(2023- soft soil
All kinds of soil
Footing Cum 8.00 1.45 1.45 2.00
SOR Filling available excavated earth (excluding rock) in
Junagadh trenches. plinth, sides of foundations etc. in layers not
2.00 District - exceeding 20 cm. in depth consolidating each disposited
(2023- layer by ramming and watering.
For PCC below footing Cum 8.00 1.45 1.45 0.10
For Footing Cum 8.00 1.25 1.25 0.30
For Column Cum 8.00 0.45 0.60 1.60
Total(I-II) (Cum):-
Junagadh Filling in foundation and plinth with murrum or selected
District - soil in layers of 20cm. thickness including watering,
(2023- ramming and consolidating etc. complete.
4.00 CEMENT CONCRETE :-
Providing and laying in position cement concrete of
specified grade excluding the cost of centering and
shuttering - All work up to plinth level :
SOR Providing and laying cement concrete 1:3:6 (1- Cement :
Junagadh 3- coarse sand : 6- hand broken stone aggregates
District - 05003A mmnominal size) and curing complete excluding cost of
(2023- formwork in (A) Foundation and Plinth
Below footing Cum 8.00 1.45 1.45 0.10
Below Plinth beam Cum 6.00 4.00 0.45 0.10
Below Plinth beam Cum 2.00 6.00 0.45 0.10
5.00 FORM WORK :-
Providing formwork of ordinary timber planking so as to
SOR give a rough finish including centering shuttering strutting
Junagadh and propping etc. Height of propping and centering below
supporting floor to ceiling not exceeding 4 M. and Sqm 2x8 1.25 0.30
District - 09001AA
(2023- removal of the same for in situ reinforced concrete and Sqm 2x8 1.25 0.30
24) plain concrete work in. (A) Foundations Footings Bases of Sqm 2x8 0.45 2.10
Columns etc. and Mass concrete.
Providing formwork of ordinary timber planking so as to
give a rough finish including centering shuttering strutting
SOR and propping etc. height of propping and centering below
Junagadh supporting floor to ceiling not exceeding 4 M. and
District - 09001H2A removal of the same for in situ reinforced concrete and
(2023- plain concrete work in. (H) (2) Sides and soffits of Beams
24) Beam Haunchings canti-levers Girders Bressumers and
Lintels exceeding 1M.in Depth.
Plinth beam Sqm 6.00 4.00 1.35
Plinth beam Sqm 2.00 6.00 1.35
5.00 REINFORCED CEMENT CONCRETE
SOR Providing and laying controlled cement concrete M.200
Junagadh and curing complete excluding the cost of formwork and
District - 05024CA reinforcement for reinforced concrete work in (C)
(2023- Slabs,landing,shelves,Balconies Lintels, Beams, Girders
7.00 24) and Cantilever upto floor two level.
For footing Cum 6.00 1.25 1.25 0.30
For Column upto plinth level Cum 6.00 0.45 0.60 2.10
Plinth beam Cum 6.00 4.00 0.45 0.45
Plinth beam Cum 2.00 6.00 0.45 0.45
8.00 REINFORCEMENT :-
SOR Providing TMT Bar FE 500D reinforcement for R.C.C. work
Junagadh including bending, binding and placing in position
District - 05014C complete upto floor two level
Thermo-Mechanically Treated bars of grade Fe-500D or
For footing 10Ø @ 150mm C/C bothway (Top &
For column 8 nos 16Ø
Stirrup 8Ø @ 150mm C/C
For Plinth beam 8 nos 12Ø
For Plinth beam 8 nos 12Ø
Stirrup 8Ø @ 150mm C/C For Plinth beam
Stirrup 8Ø @ 150mm C/C Plinth beam
Above Plinth Level :-
Cement Concrete Work
SOR Providing and laying cement concrete 1:3:6 (1- Cement :
Junagadh 3- coarse sand : 6- hand broken stone aggregates
District - mmnominal size) and curing complete excluding cost of
(2023- formwork in (A) Foundation and Plinth
Below floor slab cum 1.00 6.00 12.00 0.10
10.00 FORM WORK :-
Providing formwork of ordinary timber planking so as to
give a rough finish including centering shuttering strutting
SOR and propping etc. height of propping and centering below
Junagadh supporting floor to ceiling not exceeding 4 M. and
District - 09001G1A removal of the same for in situ reinforced concrete and
(2023- plain concrete work in. (G) Columns PillarsPosts and
24) struts. (1) Square Rectangular Polygonal in plan.
Columns, Pillars, Piers, Abutments, Posts and Struts
Column Sqm 2x6 0.45 5.00
Providing formwork of ordinary timber planking so as to
SOR give a rough finish including centering shuttering
Junagadh strutting and propping etc. Height of propping and
District - 09001B2A centering below supporting floor to ceiling not exceeding
(2023- 4 M. and removal of the same for in situ reinforced
24) concrete and plain concrete work in. (B) Flat surfaces
such as soffits of suspended floor roof slabs Landings and
11.00 the like. (2) Floors etc. above 200mm in thickness.
floor slab sqm 1.00
roof slab sqm 1.00
Providing formwork of ordinary timber planking so as to
give a rough finish including centering shuttering strutting
SOR and propping etc. height of propping and centering below
Junagadh supporting floor to ceiling not exceeding 4 M. and
12.00 District - 09001H2A removal of the same for in situ reinforced concrete and
(2023- plain concrete work in. (H) (2) Sides and soffits of Beams
24) Beam Haunchings canti-levers Girders Bressumers and
Lintels exceeding 1M.in Depth.
Roof beam Sqm 6.00 4.00 1.35
Roof beam Sqm 2.00 6.00 1.35
REINFORCED CEMENT CONCRETE
SOR Providing and laying controlled cement concrete M.200
Junagadh and curing complete excluding the cost of formwork and
13.00 District - 05024CA reinforcement for reinforced concrete work in (C)
(2023- Slabs,landing,shelves,Balconies Lintels, Beams, Girders
24) and Cantilever upto floor two level.
Column Cum 6.00 0.45 0.60 5.00
Lintel Beam cum 1.00 30.00 0.23 0.25
14.00 REINFORCEMENT :-
SOR Steel reinforcement for R.C.C. work including
Junagadh straightening, cutting, bending, placing in position and
District - 05014C binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or
For floor slab 10mm@150mm c/c
For column 8 nos 16Ø
Stirrup 8Ø @ 150mm C/C
Lintel Beam 4 nos 12mm kg
15.00 FLOORING :-
SOR Providing and laying controlled cement concrete M.200
Junagadh and curing complete excluding the cost of formwork and
District - 05024CA reinforcement for reinforced concrete work in (C) Cum 1.00 6.00 12.00 0.20
(2023- Slabs,landing,shelves,Balconies Lintels, Beams, Girders
24) and Cantilever upto floor two level
Junagadh White Stone Bela mesonry block in course in
District - superstructure with stone of approved quality in
(2023- Lime Mortar 1:5 (1-Cement :5- course sand)
16.00 24) 07010A including packing the joints etc. complete cum 1.00 6.00 5.25 0.23
Ventilation 6.00 0.65 0.65 0.23
SOR Providing 15mm thick cement plaster in single coat on
Junagadh Rough (Similar)side of single or half brick
District - 17002B walls for interior plastering upto floor two level and
(2023- finished even and smooth in (ii) Cement mortar 1:4 (1-
walls sqm 4.00 12.00 5.50
roof beam sqm 4.00 6.00 1.25
floor sqm 1.00 12.00 6.00
coloum sqm 8.00 0.44 5.00
Ventilation 12.00 0.65 0.65
SOR Providing and laying controlled cement concrete M.200
Junagadh and curing complete excluding the cost of formwork and
18.00 District - 05024CA reinforcement for reinforced concrete work in (C)
(2023- Slabs,landing,shelves,Balconies Lintels, Beams, Girders
24) and Cantilever upto floor two level.
SOR Providing TMT Bar FE 500D reinforcement for R.C.C. work
Junagadh including bending, binding and placing in position
District - 05014C complete upto floor two level
Thermo-Mechanically Treated bars of grade Fe-500D or
For Beam 8 nos 16Ø kg 4.00 6.00
For Beam 8 nos 16Ø kg 2.00 12.00
For slab 10mm@150mm c/c 1.00
SOR Providing and fixing M.S. Grills of required pattern to
Junagadh wooden frames of window etc. with m.s. flats at required
20.00 District - 10025AA specings and frame alround square or round bars with
(2023- round hended bolts and nuts or by screws (A) Plain Grill
24) (P.No. 82/Code No. 10025AA/It.No. 10.1)
Window Grill 3.00 1.20 1.20
Wall painting (two coats) with plastic emulsion paint of
SOR approved brand and manufacture on undecorated wall
Junagadh surface to give an even shade including throughly
21.00 District - 18031 brushing the surface free from mortar droppings and
(2023- other foreign matter and sand papered smooth. (P.No.
Same Qty. As Per Item No. 17
Applying priming coat of over new steel and other metal
SOR surface after and including preparing the surface by
Junagadh thoroughly cleaning, oil grease, dirt and other foreign
22.00 District - 19001 mater and scoured with brushes fine steel wool, scrapers
(2023- and sand paper with ready mixed priming paint brushing
24) red le (P.No. 134/Code No. 19001/I.No. 19.2)
Same Qty. As Per Item No. 20
Painting two coats (excluding priming coat) on new steel
SOR and other metal surface with enamel paint, brusing
Junagadh interior to give an even shade including cleaning the
23.00 District - 19002 surface an even shade including cleaning the surface of all
(2023- dirt, dust and other foreign matter. (P.No. 134/Code No.
Same Qty. As Per Item No. 20
Providing and fixing rolling shutters of approved make
SOR made of 80 mm wide M.S. laths inter-locked together
Junagadh through their entire length and jointed together at the
24.00 District - 11005B ends by end locks mounted on specially designed pipe
(2023- shaft with bracket plates, guide channels and
24) arragements for inside and outside locking with push-pull
operation including the cost of hood cover and spring etc.
complete. (B) Shutters having width 3.5 M. and above
SOR Providing and fixing standared extruded of alluminium
Junagadh section of size 63mm x 38.10mm x 1.2mm , @ Wt.
25.00 District - 11036 Kg/mt with colour Powder Coated alluminium frame for
(2023- ventilation with 5 mm thick frosted glass as details etc
24) complete for Ventilation sqm 6.00 0.65 0.65
Abstract sheet of LED Street light
SOR Description Rate Amount Total
S.No. Item NO Unit Qty. L.C.@1%
2023-24 of item (Rs.) (Rs.) Amount
Supplying & erecting Steel tubular pole
(Swaged) confirming to IS - 2713 (Part-II)
1980. Manufacturing process of steel
tubular pole should be as per IS
specification. Basic steel tube should be ISI
Marked. Pole should be painted by one coat
R&B of Zinc comet Primer and two coat of
Electric Aluminium /approved paint to be erected on
1 6-1-3. / in existing Foundation. The length of poles
2023-24 are as below.
(A) 7.5 mtr. Long Swaged Steel tubular pole
(i) pole as per IS code 410-SP-4 with 300 X
300 X 4 mm base plate with necessary G.I.
J Bolts (Approximate Pole weight 67 Kg) For
burial erection
Providing and erecting Street Light pole
bracket comprising main B Class MS pipe
of 4.2 cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of
approx. 45cms.length and suitable for
R&B mm /80mm / required size of pole top
Electric having sufficient fasteners for fixing the
SOR brackets and having spread of 1.5.mtr.
2023-24 length with 110 deg.with vertical plane &
suitable welded stays, reducer and with
check nuts complete painted with one coat
of Red oxide / PU base primer and two
coats of Aluminium / PU paint. paint with
following nos of arms.
[B] Double Arm Bracket 1.5 Mtr nos 30 907.00 27210 272.1
Supplying and erecting LED street light /
Flood light fittings with High power White
LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency
more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with
smooth finish powder coated and heat sink
extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with
R&B toughened glass with company mark/name
3 Electric 2-16-2.
engraved or embossed 160 to 270 V,Power
SOR Factor more than 0.95, THD < 10 %, CCT
2023-24 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required
LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer
incharge may select any wattage capacity
between the ranges shown.)
(i) above 36 to 48 watts (Cat-ll) nos 35 2951.00 103285 1032.85
Providing & erecting approved make street
light / wall mounting junction box
compression moulded from SMC (thermoset
R&B plastic) vertical sliding cover having locking
Electric with square head stud loop in / loop out in
SOR built terminal suitable for four core cable,
2023-24 waterproof of I.P. 54 protected with clamp or
bolt nut & earth bolt of following size.
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
R&B operate on 240 V A.C. system and having
Electric 3-10- breaking capacity 10 KA to be erected in
SOR 1.(B) existing box. confirming to IS 8828/1996
2023-24 with ISI Mark
R&B Supplying & erecting XLPE(IS:7098)(I)-88
Electric ISI unarmoured copper cable 1.1 KV grade
6 4-2-1. to be erected as directed of following size.
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
R&B conductor for 1.1 KV. to be laid on wall
Electric 4-4-2.
7 with necessary clamps or in existing trench
SOR / pipe at road crossing or floor of following
2023-24 size of cable.
Supplying and erecting B class Galvanized
R&B iron pipe having smooth finished bore of the
Electric pipe on both ends erected nuts and bolts
8 6-5-5 along the pole / wall shaping the pipe as per
2023-24 site requirement. Pipe dia as following.
Providing & laying approved make Double
walled corrugated pipes (DWC) of
R&B polyethylene(conforming to IS 14930 II )with
9 Electric 4-5-8. necessary connecting accessories of same
SOR material at required depth in existing trench
2023-24 for laying of cable. below ground / road
surface for enclosing cable
(A)50 mm outer dia nos 550 62.00 34100 341
Supplying & erecting IP 55 grade following
size section pillar fabricated from joint less
M.S. Sheet with angle iron legs made from
R&B jointless M.S. Angle with cable clamps to be
Electric buried in ground to have appropriate
SOR erection to work uniform until erected with
2023-24 cement concrete foundation and 45 cm high
bricks work finishing with plaster etc. hinged
double door internally supported on both
(C) 60 X 30 X 45 cm section pillar fabricated
from 16 Gauge MS Sheet with angle iron
legs 45 cm long made from 35 X 35 X 5 mm
thick MS angle.
Supplying & erecting approved make Digital
time switch having lithium cell 6 years
operative and operate battery backup
channel day clock with 14 memory
R&B programme, suitable to operate on 240V +
Electric 5%, 16A with, floating contacts Minimum
SOR switching setup time 1 minimum & LCD
2023-24 display. Also comprised permanent ON/OFF
switching. Programming switches & housed
in fire proof thermoplastic enclosure &
transparent cover erected as required with
necessary connection erected as directed.
Providing and erecting Approved make Four
pole moulded case circuit breaker having
R&B breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to
12 3-4-1. 100A. with Fixed thermal & magnetic nos
release suitable to work on A.C. supply
2023-24 c/s. with all internal connections, spreader
tinned copper & complete erected in existing
16 G.M.S. housing.
ICS=100% of ICU only Cat III nos 1 6112.00 6112 61.12
R&B Providing and erecting AC-3 duty 3 pole
power contactor with 2 NO & 2 NC aux
13 9-1-7. contacts complete with 415V/220V
operating coil suitable for (L&T, BCH,T.C.,
2023-24 Siemens, C&S make).
Providing 1:2:4 cement concrete foundation
& 70 % PCC from bottom including
excavation for the pole of size 60 x 60 x
cm. Deep in below ground level with plinth
of 45 cm x 45 cm(or 45 cm dia x 45 cm)
high upper ground level with necessary
curing and finishing in approved manner. (
for 7.5 & 8/8.5 mtr pole)
Measurement sheet of LED Street light
SOR 2023- Description
S.No. Item NO Unit NOS Length Widht Height Qty.
Supplying & erecting Steel tubular pole
(Swaged) confirming to IS - 2713 (Part-II)
1980. Manufacturing process of steel tubular
pole should be as per IS specification. Basic
steel tube should be ISI Marked. Pole should
be painted by one coat of Zinc comet Primer
and two coat of Aluminium /approved paint to
1 6-1-3. be erected on / in existing Foundation. The
SOR 2023- length of poles are as below.
(A) 7.5 mtr. Long Swaged Steel tubular pole
(i) pole as per IS code 410-SP-4 with 300 X
300 X 4 mm base plate with necessary G.I. J
Bolts (Approximate Pole weight 67 Kg) For
burial erection
Providing and erecting Street Light pole
bracket comprising main B Class MS pipe of
4.2 cm/require outside dia. complete with
suitable B Class M.S. sleeve tubing of approx.
45cms.length and suitable for 76.5 mm /80mm
R&B / required size of pole top having sufficient
Electric fasteners for fixing the brackets and having
2 6-5-2-a spread of 1.5.mtr. length with 110 deg.with
24 vertical plane & suitable welded stays, reducer
and with check nuts complete painted with one
coat of Red oxide / PU base primer and two
coats of Aluminium / PU paint. paint with
following nos of arms.
[B] Double Arm Bracket 1.5 Mtr nos 30
Supplying and erecting LED street light / Flood
light fittings with High power White LEDs
wattage of 3 Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast
aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses, with
R&B toughened glass with company mark/name
3 Electric 2-16-2. engraved or embossed 160 to 270 V,Power
SOR 2023- Factor more than 0.95, THD < 10 %, CCT
24 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-
79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge
may select any wattage capacity between the
(i) above 36 to 48 watts (Cat-ll) nos 35
Providing & erecting approved make street
light / wall mounting junction box compression
moulded from SMC (thermoset plastic) vertical
R&B sliding cover having locking with square head
Electric stud loop in / loop out in built terminal suitable
SOR 2023- for four core cable, waterproof of I.P.
24 protected with clamp or bolt nut & earth bolt of
following size.
(A) 200mm x 127mm x 83 mm nos 30
providing and erecting Miniature circuit
breaker single pole 6A to 25A suitable to
R&B operate on 240 V A.C. system and having
Electric breaking capacity 10 KA to be erected in
SOR 2023- existing box. confirming to IS 8828/1996 with
R&B Supplying & erecting XLPE(IS:7098)(I)-88 ISI
Electric unarmoured copper cable 1.1 KV grade to be
6 4-2-1. erected as directed of following size.
24 (A) 2 core 2.5 Sq. mm mtr 30 10
Providing and erecting XLPE(IS:7098)(I)-88
ISI armoured cable multistrand Copper
R&B conductor for 1.1 KV. to be laid on wall with
Electric 4-4-2.
7 necessary clamps or in existing trench / pipe
SOR 2023- at road crossing or floor of following size of
(B) 3 core 4 Sq. mm mtr 1 550
Supplying and erecting B class Galvanized
R&B iron pipe having smooth finished bore of the
Electric pipe on both ends erected nuts and bolts
8 6-5-5 along the pole / wall shaping the pipe as per
24 site requirement. Pipe dia as following.
(D) 50 mm dia. mtr 30 1.2
Providing & laying approved make Double
walled corrugated pipes (DWC) of
R&B polyethylene(conforming to IS 14930 II )with
9 Electric 4-5-8. necessary connecting accessories of same
SOR 2023- material at required depth in existing trench
24 for laying of cable. below ground / road
surface for enclosing cable
(A)50 mm outer dia nos 1 550
Supplying & erecting IP 55 grade following
size section pillar fabricated from joint less
M.S. Sheet with angle iron legs made from
jointless M.S. Angle with cable clamps to be
buried in ground to have appropriate erection
R&B to work uniform until erected with cement
Electric concrete foundation and 45 cm high bricks
SOR 2023- work finishing with plaster etc. hinged double
24 door internally supported on both side,
(C) 60 X 30 X 45 cm section pillar fabricated
from 16 Gauge MS Sheet with angle iron legs
45 cm long made from 35 X 35 X 5 mm thick
Supplying & erecting approved make Digital
time switch having lithium cell 6 years
operative and operate battery backup
channel day clock with 14 memory
R&B programme, suitable to operate on 240V +
Electric 5%, 16A with, floating contacts Minimum
SOR 2023- switching setup time 1 minimum & LCD
24 display. Also comprised permanent ON/OFF
switching. Programming switches & housed in
fire proof thermoplastic enclosure &
transparent cover erected as required with
necessary connection erected as directed.
Providing and erecting Approved make Four
pole moulded case circuit breaker having
R&B breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to
12 3-4-1. 100A. with Fixed thermal & magnetic release nos
suitable to work on A.C. supply 50 c/s. with all
24 internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S.
ICS=100% of ICU only Cat III nos 1
R&B Providing and erecting AC-3 duty 3 pole power
contactor with 2 NO & 2 NC aux contacts
13 9-1-7. complete with 415V/220V operating coil
suitable for (L&T, BCH,T.C., Siemens, C&S
(A) for 25 / 32 A rating nos 1
Providing 1:2:4 cement concrete foundation &
70 % PCC from bottom including excavation
for the pole of size 60 x 60 x 120 cm. Deep in
14 6-3-5. below ground level with plinth of 45 cm x 45 nos 30
cm(or 45 cm dia x 45 cm) high upper ground
level with necessary curing and finishing in
approved manner. ( for 7.5 & 8/8.5 mtr pole)
Estimation of specific gravity separator
ABSTRACT SHEET Market Rate/Quotation
Sr no Description Qty Unit Rate Amount
1 Supplying, Providing and Installing of Specific gravity separator 1.00 Nos. 3,50,000
Estimation of Trommel Machine
ABSTRACT SHEET Market Rate/Quotation
Sr no Description Qty Unit Rate Amount
1 Supplying, Providing and Installing of Trommel machine
Estimation of Fire Extinguisher
ABSTRACT SHEET Market Rate/Quotation
Sr no Description Qty Unit Rate Amount
1 Supplying, Providing and Installing of Fire Extinguisher 10.00 Nos. 5,800
Comparison sheet
Supplying, Providing and Installing of Fire Extinguisher
Sr. No. Agency Name Amount
1 L S Life safety portable fire extinguisher
2 Lifeguard portable fire extinguisher
3 SEAARA portable fire extinguisher
Estimation of Bailing Machine
ABSTRACT SHEET Market Rate/Quotation
Sr no Description Qty Unit Rate Amount
1 Supplying, Providing and Installing of Belling Machine
Comparison sheet
Supplying, Providing and Installing of Belling Machine
Sr. No. Agency Name Amount
1 Unbranded Hydraulic Plastic Bailing Machine
2 JKREYANSH Hydraulic Plastic Bailing Machine
3 SOHAM IMPEX Hydraulic plastic bailing machine
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
T119-RX07-Tender Nivida.pdf
T119-RX07-SBD.pdf
T119-RX07-Site Visit Certificate.pdf
T119-RX07-Abstract and Drawing.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .