Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.2 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC ACCEPTED L1 | |
| 2 | L2₹24.0 L+₹6.0 L (33.5%)Rejected-Finance 186 GANDHI MARKET AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Being rejected L2 |
Tender Value
₹25.1 L
EMD Value
₹50,200
Closing Date
12 Jul 2021, 6:00 pmClosed
SHRI N N LANGHE EE GE SOUTH AMBALA
GE SOUTH AMBALA CANTT
CA NO GE SOUTH AMB 14 2021 2022 REPAIR MAINT OF INTERNAL ELECTRIFICATION SYSTEM AND ALLIED ESSENTIAL SERVICES INCLUDING DAY TO DAY MAINT ASSOCIATED WORKS IN MD ACCN OF OFFICERS JCOs ORs IN THE AREA OF STAFF ROAD, MANEKSHAW ENCLAVE CONVEY PARK
2021_MES_451424_1
GE(SOUTH)/AMB-14/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE SOUTH AMBALA CANTT
AS PER NIT
9 documents required · 9 mandatory
₹500
GE SOUTH AMBALA CANTT
₹50,200
Yes
16 Aug 2021
14 Jun 2021
14 Jul 2021
14 Jun 2021
12 Jul 2021
29 Jun 2021
14 Jun 2021 - 28 Jun 2021
Amount
Taking down old unserviceable 4/8/12 Way MCB/MCCB/Loadline DBs any type including removing unserviceable MCB SP/SPN and materials incl debris from site complete all as specified and directed.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 250 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 160 AMPS, 25 KA as incomer and MCB s as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
Supply and fixing in repair sheet metal enclosures vertical distribution board VTPN,(MCCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, with and including MCCB 4 pole thermal release type, 125AMPS, 25 KA as incomer and MCBs as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
Supply and fixing in repair sheet metal enclosures distribution board for TPN, (MCB DB) 4 ways, double door , 415 volts with 200 amps rated bus bar IP 43 protection, with shrouded neutral bar and insulated bus bar and earth link, suitable for MCB 4 pole as incomer and MCB s as out going complete with making suitable size of MS cabinet 2 mm thick dully grouted on the wall (flush) with opening arrangement including making connections with suitable size of lugs and making good the disturbed surface matching with existing surface complete all as specified and directed.
Supply, installation, testing of SPN distibution board 12 way,double door , IP 43, as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed.
Supply, installation, testing of SPN distibution board 8 way,double door , IP 43 , as per IS 8623 including 200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed.
Supply, installation, testing of SPN distibution board 4 way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles complete all as specified and directed.
Supply and fixing (in repair) for MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 6 to 32 Amps, ISI marked complete all as specified and directed.
Supply and fixing (in repair) for MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, 'B' curve 40 to 63 Amps, ISI marked complete all as specified and directed.
Supply and fixing (in repair) for MCB single pole and neutral 240 volts, 16 to 32 Amps,10KA, 50 Hz, 'B' Series complete all as specified and directed.
Supply and fixing (in repair) for MCB single pole and neutral 240 volts, 40 to 63 Amps, 10KA, 50 Hz, 'B' Series complete all as specified and directed.
Supply and fixing sheet steel enclosure with separate bus bar chamber for cable termination with and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25KA, 125 Amps, B curve, complete all as specified and directed.
Supply and fixing in sheet steel enclosure with separate bus bar chamber for cable termination with and including MCCB four pole, 240 volts, 50Hz , breaking capacity 25KA, 160Amps, B curve, complete all as specified and directed.
Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 100 Amps, B curve complete all as specified and directed.
Supply and fixing in repair MCB four pole, 240 volts, 50Hz , breaking capacity 10KA, 40A to 63 Amps, B curve, complete all as specified and directed.
Supply and fixing channel for fixing of LED tube rod, aluminium housing body in CRCA body suitable for 18/20 watt LED tube, high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed. (Tube rod shall be measured and paid for separately).
Supply and fixing 18 W/ 20W Polycarbonate LED tube light, environment friendly, high efficient, T8 with aluminium extrusion heat sink for optimum performance with high luminous efficiency and easy and taking down existing tube light and removal complete all as specified and directed. NOTE:- Tube rod must be get approved from Engr in charge to check fesibilty i.e. one end contact or two end contact for fixing in existing LED fittings.
Supply and fixing LED luminaries of capacity 20 watt integrated aluminium batten complete including removing of unservicable fitting of any type in any position complete all as specified and directed.
Supply and fixing decorative surface mounted LED tube light fitting with high efficient diffuser mirror light, aluminium housing in CRCA body suitable and including 10 watt LED tube high efficient, AC 220-240 volts, 50 Hz and connecting with copper conductor flexible cable of size 0.50 Sqmm from ceiling rose to connector of the light including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Supply and fixing bulk head light fitting, 10 watt, energy efficient with lamp 10 watt with provision of 2/3 core PVC copper conductor cable 0.5 Sqmm size from ceiling rose to light fitting complete including disconnecting and taking down old existing light fitting of any description and in any position complete all as specified and directed.
Material and labour for replacement of old unserviceable lamp any type with LED lamp 9 Watt with B 22 base cap type wider spread LED bulb with Battery back-up complete all as specified and directed.
Supply and fixing recess/ surface mounted LED flat panel 2' x 2' with high efficient LEDs and glare free full decorative light fitting, 36 watt, energy efficient provided with including LED 36 watt with provision of 2/3 core PVC copper conductor cable 1.5 Sqmm size to light fitting and complete including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing in repair in replacement bracket for security light made up of 25mm dia, 0.9 metre long GI pipe, light grade, bent to required length, fixed to wall with two clamps made of 20 x 3 mm mild steel flat minimum 15cm long, 4 nos 8mm dia bolts with nuts complete all as specified and directed.
Supply and fixing LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Three core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing LED security light luminaire 45 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with all accessories internally pre wired and including connecting up with Three core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Supply and fixing post top lantern LED 30W , cast aluminium spigot, with high effieient LED light, with poly carbonate diffuser, complete with high efficient LED lamp 30 W and accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing LED security light luminaire 30 watt , pressure die cast aluminum housing, toughened heat resistant glass, IP65 protection, better optics for uniform distribution with multiplte LEDs not less than 2 W eachand having optical grade polycarbonate lens with minimum 4 hours battery back up all accessories internally pre wired and including connecting up with Three core 1.5 sq mm copper conductor cable from connector to ceiling rose to connection of light including disconnecting and taking down old unserviceable security light fitting of any description and in any position complete all as specified and directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounting type LED round type Decorative ,wall mouting ,brushed nickel with 9W LED capacity B22 Lamp & clear diffuser Oval/ round type with IP 20 Protection including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Disconnecting and taking down old existing wall fitting of any description and in any position and Supply and fixing surface mounting/ ceiling mouting type LED round/ Oval type Decorative fittings 10W LED with clear diffuser Oval/ round type with IP 20 Protection including connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Dismantling/taking down carefully aluminium/ copper point wiring (light, fan,socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators , sockets, light fittings etc., removing materials to stores for keeping in safe custody for taking credit and making good the disturbed surfaces of walls,ceilings etc. complete all as specified and directed.
Material and labour for concealed point wiring using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH (FIRE Retardant Low Smoke and low Halogen), PVC insulated and unsheathed stranded cable drawn through and including non metallic, medium grade PVC concealed conduit not less than 20mm dia and its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with Metal flush boxes made out of GI sheet 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush box for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH (FIRE Retardant Low Smoke and low Halogen) copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/bell point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 31.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 31.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 31.00 above but point wiring for one socket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Material and labour for point wiring in existing conduit using approved colour coding as per IS, with multi stranded copper conductor 1.5 sqmm (Nominal area), single core, FRLSH PVC insulated and unsheathed stranded cable drawn through in existing non metallic/mettalic medium grade concealed/Surface conduit and including replacement of its fittings including all tees, bell mouth pieces and fixing accessories such as couplers, saddlers, pipe hooks etc, PVC junction boxes ISI marked with GI metal flush boxes made out of 1.2mm thick of any module from 2 to 18 module confirming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly coated with two coats of anti corrosive paint including modular cover plates with frame i.e. inner and outer plate extended upto 25 mm over metal flush boxes for housing the modular switches, socket outlets, fan regulators etc with brass screws and brass washers and making good the disturbed surfaces as per existing for one light / fan / Bell point contorlled by one switch including 1.5 sqmm single core PVC insulated and unsheathed FRLSH copper cable, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor upto common earth and connecting to common earth dolly with suitable size of lugs for one light point/ fan point/Bell Point controlled by one switch complete all as specified and as directed. NOTES:- 1. Switch, socket and fan regulators to be measured and paid for separately. 2. All chases will be cut by chase cutter only.
Description all as per item No 35.00 here in before but for socket out let point 5 Amps on same board complete all as specified and directed.
Description all as per item No 35.00 here in before but for socket out let point 5 Amps on independent board complete all as specified and directed.
Description all as per srl item No 35.00 above but point wiring for onesocket out let 15&5 Amps (independent) controlled by one switch with using 2.5 Sq mm (nominal area) stranded copper conductor complete all as specified and directed.
Supply and fixing in repair modular switches, one way, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing in repair modular switches, one way, 20 Amps, one module, 230 volt , AC supply, complete all as specified and directed.
Supply and fixing in repair modular socket outlet 6 amps, 2/3 pin combined 2 module, 230 volt, complete all as specified and directed.
Supply and fixing in repair modular socket outlet 16 amps,2/3 pin , combined 2 module, complete all as specified and directed.
Supply and fixing in repair fan regulator / Dimmer step type one module / 2 module, 120w 230 Volts, 50 Hz, AC complete all as specified and directed.
Supply and fixing in repair modular switches, bell push, 6 amps one module, 230V, 50 Hz supply, complete all as specified and directed.
Supply and fixing in repair modular blanking plate 1 module complete all as specified and directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and including medium grade, ISI marked, PVC conduit not less than 25 mm dia with FRLSH accessories, concealed on wall/ceiling and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover extended up to 25 mm over sunken box for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point/bell point controlled by one switch. NOTES:- Switch, socket and fan regulators to be measured and paid for separately .
Description all as per item No 46.00 here in before but for socket out let point 5 Amps on same board,complete all as specified and directed.
Description all as per item No 46.00 here in before but for socket out let point 5 Amps on independent board,complete all as specified and directed.
Description all as per item No 46.00 above but with 2.5 Sqmm cable for 3pin 15 Amps switch socket outlet (Power Point),complete all as specified and directed.
Supply and fixing in repair switch piano 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing in repair switch piano 15 Amps flush type one way 230 Volts, 50 Hz , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing in repair bell push 5 Amps, flush type, single pole, one way, 230 volt , AC supply, ISI Marked, complete all as specified and directed.
Supply and fixing in repair socket outlet 3 pin 6 amps, 230 volt. flush type, ISI Marked, complete all as speciied and directed.
Supply and fixing in repair socket outlet 2 in 1, 6 pin 5 /16 Amp and multi pin flush type, complete all as specified.
Supply and fixing in repair ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
Supply and fixing in repair fan regulator/ Dimmer electronic step type ,230 Volts, AC supply, suitable for ceiling fan any type/make/sweep, complete all as specified and directed.
Supply and fixing in repair door bell electric ,ding dong /musical type, single phase 230 volts, ISI marked complete all as specified.
Supply and fixing in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings,complete all as specified.
Supply and fixing in repair sheet metal enclosure SP with two pin and earth plug and socket with one single pole, MCB 32 Amps, 'C' curve, 240 volts complete all as specified and directed.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 2.5 sqmm drawn in and including rigid non metallic PVC medium grade 20 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.50 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE:- 3 run of 2.5 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 6sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 4 sqmm, green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE:-2 run of 6.0 sqmm and 1 run of 4 sqmm cable with concealed conduct shall be measured as 1 unit.
Material and labour for sub main wiring with two single core FRLSH PVC insulated unsheathed copper conductor cable 4 sqmm drawn in and including rigid non metallic PVC medium grade 25 mm dia New concealed conduit with accessories on wall or ceiling with one additional PVC insulated , stranded copper conductor FRLSH of 2.50 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring and making good the disturbed surface complete all as specified and directed. NOTE:- 2 run of 4.0 sqmm and 1 run of 2.50 sqmm cable with concealed conduct shall be measured as 1 unit.
Supply only 3 pin plug top, 5 amp capacity, 240 V, AC, heavy duty, ISI marked complete all as specified and directed.
Supply only 3 pin plug top, 15 amp capacity, 240 V, AC, heavy duty, ISI marked complete all as specified and directed.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.0 mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron wire 4 mm as earthing lead (upto terminal point) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) Taking out old unserviceable earthing complete all as specified and directed. NOTE:- The rates for earth work, GI protection pipe, funnel, wire wesh, CI cover, etc shall be deemed to be including in quoted rates.
Material and labour for preparing Old plastered or unplastered on wall surface and applying two coats of white wash including finishing complete all as directed and specified.
Material and labour for disconnecting all loose wiring / cable in hanging position and supply and fix in repair PVC conduit pipe medium duty of Nominal Dia 25mm with suitable clamps after passing all loose wiring / cable through pipe complete all as specified and directed.
Supply and fixing in repair PVC cable tray / casing capping of size 50mm X 50mm including disconnecting all loose wiring / cable in hanging position and clamping them on a tray complete all as specified and directed.
Supply and fixing PVC conduit pipe medium duty of Nominal Dia 40mm with suitable clamps concealed in wall surface/ suitably clamped on wall surface for passing wiring / cable complete all as specified and directed.
Material and labour for disconnecting all loose wiring / cable in hanging position and supply and fix in repair flexible PVC conduit pipe medium duty of Nominal Dia 20mm with suitable clamps after passing all loose wiring / cable through pipe complete all as specified and directed.
Material and labour for preparing Old plastered or unplastered on wall surface and applying two coats of cement base paint in patches on walls surface with including finishing and matching with existing complete all as specified and directed.
Material and labour for dismentaling and 4/8/12way TPN DB / Load after disconnect all incomming and outging connections refixing same after repair and replacement of new DB door and connectors,and fixture and fault rectification including replacement of wornout links complete all as specified and directed. Note:- Cost of refixing serviceable MCCB/MCBs included in quoated rates.
Material and labour for dismentaling and 8/12way SPN DB after disconnect all incomming and outging connections refixing same after repair and replacement of new DB door and connectors,and fixture and fault rectification including replacement of wornout links complete all as specified and directed. Note:- Cost of refixing serviceable MCCB/MCBs included in quoated rates.
Supply and fixing PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
Supply and fixing PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and directed.
Material and labour for replacement PVC insulated, unsheathed cable 2.5 Sqmm single core 1100 volt grade with multi stranded copper conductor ISI marked complete all as specified and directed.
Material and labour for replacement of Cable PVC copper conductor flexible twin core 0.75mm complete all as specified and directed.
Material and labour for replacement Fan condenser 2.5 mfd complete all as specified and directed.
Material and labour for Cutting of road/hard standing to a size of width and not exceeding 90cm in depth for laying of protection pipe/Cable including returining filling , spreading levelling watering and well ramming in layers and providing PCC in 1:2:4 type B1 for the top 100mm layer using 20mm graded stone aggregate after the pipes /cables are laid complete all as specified and directed.
Disconnecting and taking down old existing Bollard light fitting of any description and in any position and Supply and fixing LED bollard light fittings with aluminium pipe housing surface mounting LED round/ squar 10 W adjusable with high efficiency low glare diffuser with pressure die casted housing with efficient high output LED IP 65 Protection including base frame made up of sheet metal and connecting up with three core 1.5 sqmm flexible copper conductor cable complete all as specified and directed.
Material and labour for replacement of FRP box of size of size with and including MCB 6 A SP complete all as specified and directed.
Material and labour for PCC for pole foundation of 1:3:6 type C2 40mm graded stone aggregate complete all as specified and directed.
Material and labour for PCC FOR coping of pole 1:2:4 type B1 20mm graded stone aggregate complete all as specified and directed.
Supply and fixing house service bracket (hook type) complete with 3.0 M long GI Pipe 40mm dia medium grade pipe, two 90 degree bends. MS hook, stay or guy including fixing clamps etc and taking down old/ existing house service bracket complete all as specified and directed.
Supply and fixing modular one/two module TV socket / telephone socket complete all as specified and directed.
M/S Sonu Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .