GEMC-511687764533310
Awarded to Medicaid Systems
₹1.7 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Multi 12 channel ECG Machine | Medicaid & Cardio Max-12 | - | 2 NOS | ₹84,999 | 169,998 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.7 LQualified Make: Medicaid
Model: Medicaid & Cardio Max-12 389 INDUSTRIAL AREA PHASE II CHANDIGARH CHANDIGARH 160001 | CHANDIGARH | CHANDIGARH | 160001 | Make: Medicaid
Model: Medicaid & Cardio Max-12 | L1 | Qualified | |
| 2 | Disqualified Make: Meditec
Model: Make: Meditec International England Ltd. & Model: E-427 203 SWASTIK BHAWAN COMMERCIAL COMPLEX CENTRAL DELHI RANJEET NAGAR CENTRAL DELHI DELHI 110008 | WEST DELHI | DELHI | 110008 | Make: Meditec
Model: Make: Meditec International England Ltd. & Model: E-427 | - | Disqualified | |
| 3 | Disqualified Make: ASPEN
Model: ASPEN 10 122 KATRA MADARI KHAN MOTI KATRA AGRA AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | Make: ASPEN
Model: ASPEN | - | Disqualified | |
| 4 | Disqualified Make: BPL
Model: BPL 00 PC GROUP AKHARI BYPASS TRIMUHANI CHUNAR ROAD VARANASI VARANASI VARANASI UTTAR PRADESH 221011 | VARANASI | UTTAR PRADESH | 221011 | Make: BPL
Model: BPL | - | Disqualified | |
| 5 | Disqualified Make: Dr DIAS
Model: Homo Diaz 1200G 16 90 2ND FLOOR SUBHASH NAGAR NEW DELHI WEST DELHI DELHI 110027 | WEST DELHI | DELHI | 110027 | Make: Dr DIAS
Model: Homo Diaz 1200G | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 Oct 2018, 12:00 pmClosed
electrocardiography ekg/ecg units Average Turn Over of Last 3 Years 6 Lakh (s) Experience with Gov. Required 20 Year (s) Electrocardiography Ekg/ecg Units ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Mobility
portability Protective splashproof case for clean storage and safe transport * Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm yes * Heart rate trend display of at least previous 24 hours yes * In built Software and/or standard of communication yes * Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed yes * 1/4 through a exhaust cooling fan User interface manual * Noise Lavel (dba) - * Electrical protection provided by fuses in both live and neutral supply lines yes * Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * Arrhythmia detection facility required; minimum gradation of 1 bpm yes * Functional requirements: electricity;AC-powered; bedside device designed to continuously detect
measure
and display a patient’s electrocardiogram through leads and sensors attached to the patient
it also typically display heart rate
the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen
Allows display of single
5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal yes * 2/4 rechargeable battery Power consumption - * weight - * Power cable length (meter) 3 METER OR MORE * Display must allow easy viewing in all ambient light levels yes * Audiovisual alarms required: high and low heart rate; operator variable settings
cardiac arrhythmia
sensor/wire disconnected
low battery yes * STANDARDS AND SAFETY
CERTIFICATIONS Certification(s) ISO 13485 Certificate For Quality Standard
Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs)
C E Approved product * MISCLANEOUS Warranty (years) 3 3
5 (or higher) power input and frequency 220 To 240V
50 Hz AC * Certificate of Calibration and Inspection to be provided YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mrinmoy Singha 799001
O/o the MD NHM
State Health Family Welfare Society
Palace compound
Agartala - 799001 2 15 3/4
651589
GEM/2018/B/92445
GeM Contract
electrocardiography ekg/ecg units
GeM Contract
15 days
Tripura; West Tripura
PRODUCT
Awarded to Medicaid Systems
₹1.7 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Multi 12 channel ECG Machine | Medicaid & Cardio Max-12 | - | 2 NOS | ₹84,999 | 169,998 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| electrocardiography ekg/ecg units Average Turn Over of Last 3 Years 6 Lakh (s) Experience with Gov. Required 20 Year (s) Electrocardiography Ekg/ecg Units ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Mobility | - | - | - |
| portability Protective splashproof case for clean storage and safe transport * Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm yes * Heart rate trend display of at least previous 24 hours yes * In built Software and/or standard of communication yes * Heat Dissipiation: Should maitain nominal Temp and the heat should be disbursed yes * 1/4 through a exhaust cooling fan User interface manual * Noise Lavel (dba) - * Electrical protection provided by fuses in both live and neutral supply lines yes * Operating condition: Capable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances yes * Arrhythmia detection facility required; minimum gradation of 1 bpm yes * Functional requirements: electricity;AC-powered; bedside device designed to continuously detect | - | - | - |
| measure | - | - | - |
| and display a patient’s electrocardiogram through leads and sensors attached to the patient | - | - | - |
| it also typically display heart rate | - | - | - |
| the device is typically equipped with audible and/or visual alarms that are triggered when the patien's parameters drop below or exceed pre-set limits: Continuous display of patient ECG and heart rate on screen | - | - | - |
| Allows display of single | - | - | - |
| 5 lead ECG or simultaneous display of at least 5 waves selected from up to 12 points Operator can set audiovisual alarm levels for low or high heart rate Operates from mains voltage or from internal yes * 2/4 rechargeable battery Power consumption - * weight - * Power cable length (meter) 3 METER OR MORE * Display must allow easy viewing in all ambient light levels yes * Audiovisual alarms required: high and low heart rate; operator variable settings | - | - | - |
| cardiac arrhythmia | - | - | - |
| sensor/wire disconnected | - | - | - |
| low battery yes * STANDARDS AND SAFETY | - | - | - |
| CERTIFICATIONS Certification(s) ISO 13485 Certificate For Quality Standard | - | - | - |
| Electrical Safety Conforms To Standards For Electrical Safety IEC-60601-1 Shall Meet IEC-60601-1-2 (General Requirements For Safety - Electromagnetic Compatibility) And IEC 60601-2-25 (Essential Performance Of Electrocardiographs) | - | - | - |
| C E Approved product * MISCLANEOUS Warranty (years) 3 3 | - | - | - |
| 5 (or higher) power input and frequency 220 To 240V | - | - | - |
| 50 Hz AC * Certificate of Calibration and Inspection to be provided YES * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Mrinmoy Singha 799001 | - | - | - |
| O/o the MD NHM | - | - | - |
| State Health Family Welfare Society | - | - | - |
| Palace compound | - | - | - |
| Agartala - 799001 2 15 3/4 | - | - | - |
Exempted
16 Oct 2018
25 Sept 2018
contract_GEMC-511687764533310.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_651589.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .