| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.9 CrAccepted-AOC 11 JAMES HICKEY SARANI FORMALLY KNOWN AS DACRES LANE 2ND FLOOR KOLKATA 700069 | KOLKATA | KOLKATA | WEST BENGAL | 700069 | ₹64.9 Cr | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹65.3 CrRejected-Finance SHREE SHYAM SADAN 10 2 PARAS SOCIETY PANCHVATI JAMNAGAR GUJARAT 361008 | JAMNAGAR | GUJARAT | 361008 | ₹65.3 Cr | L2 | Rejected-Finance NOT BEING L1 |
| 3 | L3₹65.8 CrRejected-Finance | ₹65.8 Cr | L3 | Rejected-Finance NOT BEING L1 |
| 4 | L4₹68.1 CrRejected-Finance | ₹68.1 Cr | L4 | Rejected-Finance NOT BEING L1 |
| 5 | L5₹70.0 CrRejected-Finance | ₹70.0 Cr | L5 | Rejected-Finance NOT BEING L1 |
Tender Value
₹60 Cr
EMD Value
₹15 L
Closing Date
17 Nov 2023, 6:00 pmClosed
CHIEF ENGINEER CG GOA
CHIEF ENGINEER CG GOA 403806
CONSTRUCTION OF OTM ACCOMMODATION FOR COAST GUARD REGIONAL HEADQUARTERS NW AT SECTOR 18 GANDHINAGAR
2023_MES_613648_1
83025/E8
Open Tender
Civil Works
660 days
GANDHINAGAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
GE (I) CG PORBANDAR
₹15 L
Yes
5 Jan 2024
14 Aug 2023
20 Nov 2023
14 Aug 2023
17 Nov 2023
3 Nov 2023
Amount
SCHEDULE "A" Part - I (BUILDING / STRUCTURE WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY ) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD PATH, CULVERT AND HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (COMPOUND WALL /FENCING & GATE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XI (AIR CONDITIONING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XII (FIRE FIGHTING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIII (AREA LIGHTING/VENTILATION) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-XIV (ERTHING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XV (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
FIRE FIGHTING:-Supply, installation, testing and commissioning of FM approved and UL listed microprocessor- based, true peer-to-peer networkable, 10 loop addressable Fire Alarm Control Panel (FCAP) with its own microcontroller memory, communication module, fire device loop interface cards for intelligent initiating and indicating devices and peer-to-peer networkable with other addressable fire alarm panels. conforming to UL 2572 mass notification systems & NFPA 72, with required accessories complete all as specified and directed by the engineer-in-charge. Make: Notifier NFS 3030 + DVC or equivalent model of Bosch, Hochiki The FACP shall meet the following specifications / functional requirements. [i] The FACP shall have one to ten isolated intelligent Signalling Line Circuits (SLCs) capable of connecting up to 159 detectors and 159 modules per SLC or 318 devices per loop. [ii] The FACP shall have a degrade mode and the loops shall work in degrade mode in case of the CPU failure. [iii] The FACP shall have 640 character LCD backlit display/ Touch Screen display, full QWETRY program keypad, LED indicators viz. power; fire alarm; supervisory; system trouble; other event; signals silenced; point disabled; CPU failure; controls active; etc. membrane switch controls viz. acknowledge; signal silence; drill; system reset; lamp test; etc [iv] The FACP shall have four access levels, flash EPROM, 240 VAC power supply, automatic battery charger, 24 V sealed lead acid batteries, sufficient for 24 hrs normal working and 30 min in alarm condition.
[v] The FACP shall have manual sensitivity adjustment up to nine levels, built-in alarm; trouble; security and supervisory relays, history file with 4000-event capacity in non-volatile memory plus separate 1000-event alarm-only file, keypad operation, LCD unit to indicate fire / fault signal of individual unit, in built printer to log all incoming data, etc. [vi] The FACP shall have integrated 8 channel digital voice evacuation system controller capable of broadcasting evacuation messages on the same peer-to-peer network, fire fighter's telephone two-way communication system capable of supervising all the speaker circuits with adequate zone control and accessories etc. NOTES: [i] The FACP shall be servicable by any system integrator & shall not have dependency on specific system integrator. [ii] The FACP shall have feature to "ADD", "EDIT" & "DELETE" field devices like detectors & modules without dependency on PC / Software / Special tool / dongle.
Supply, installation, testing and commissioning of FM approved and UL listed Network Control Display (NCD) capable of full supervision of all inputs and network integrity, having10" high definition 1024 X 600 colour touchscreen display, environmental adjustment controls to maximize LCD legibility, LED status indicators (for power supply and off normal condition), network connection, three USB connections, trouble relay, tamper and trouble inputs, etc. and features viz. network-wide acknowledge silence, reset, lamp test, fully programmable node-mapping subsystem, colour coded icon based event notification, event vectoring, etc. along with UL listed non-resettable 24 VDC power source complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of CO sensor transmitter for basement ventilation automatic fan control system having electrochemical diffusion, electrolyte type Gel-based (no leak, no membrane rupture, no orientation problem and no false alarm) sensor element / cell, measuring range 0-300 ppm, response time T90 < 50 s, warm-up time (first time) < 3 minutes, IP 65 protection, sensor coverage area > 700 sqm, etc., suitable for working temperature -20 to 50 °C, 15- 90 %RH (non-condensing), 18- 28 VDC (overload protected), 4-20 mA linear output, UL 94: V2 flammability rating, complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of FM approved and UL listed addressable relay module to provide FACP a dry-contact output for activating a variety of auxiliary devices, viz. fans, dampers, control equipment, etc. having built-in type identification, integral LED indicators, high noise immunity, SMES screws with clamping plates for wiring ease, direct-dial entry of address, etc. complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning of UL listed (fire fighter's) addressable Telephone Jack mounted to a single-gang electrical back box with suitable interface module for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge.
Supply, installation, testing and commissioning of UL listed Fire Fighter's Telephone Handset for two way communication with the Central Fire Fighter Telephone Console complete all as specified and directed by engineer-in-charge.
M & L for low smoke zero halogen (LS0H) flame retardant fire alarm cable, conforming to BS 7629-1, BS 6387 & BS EN 50200 and rated for 500 V, drawn through concealed PVC conduit and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicone rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheath conforming to BS 7655, suitable for operating temperature range -30 ˚C to +70 ˚C and minimum bending radius being 6 times the overall cable diameter, RED in colour, including laying, termination and ferruling complete all as specified and directed by engineer-in-charge.
2 core, 1.5 mm²
2 core, 2.5 mm² (supply to hooter/strobe)
M & L for transparent FR PVC insulated, twin core copper conductor flexible industrial Speaker cable having stranded annealed tinned copper conductor, PVC insulated cores twisted to form pairs, shielded for interference rejection, unarmoured PVC sheathed 1.1 kV grade in conductor size 2 X 1.0 mm2 including laying, termination and ferruling complete all as specified and directed by engineer-in-charge. Make: RR Kabel, Polycab, Havells
Supply, installation, testing and commissioning of UL listed all purpose 2 W ceiling speaker having crush and rust resistant design and fully ABS plastic & ABS grille with tap-setting range between 1/4 W and 2 W, rated (RMS) voltage 70.7 V, sound pressure level at 1 W (1 m & 1 kHz) 80 ± 4 dB, frequency response 125 Hz- 16 kHz, (-10 dB with reference to 1 kHz), complete all as specified and directed by engineer-in-charge. Make: Notifier NF-SP100CI/UL equivalent model of Bosch, Hochiki
M & L for low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed by the engineer-in-charge.
2 core, 2.5 mm² (for instrumentation)
3 core, 2.5 mm² (for auto start/stop panel)
12 core, 2.5 mm² (for diesel engine pump)
M & L for 1.1 kV grade copper conductor, XLPE insulated unarmoured cable conforming to IS 7098 (Part 1): 1988, having stranded copper compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete all as specified and directed by engineer-in-charge.
3 core 150 mm² (for electric motor driven main fire pump)
4 core 25 mm² (for fire lift)
3 core 16 mm² (for booster pump)
3 core 10 mm² (for jockey pump)
S & F of 100 mm X 50 mm X 1.6 mm (L X D X T) size of perforated painted with powder coating MS cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts, etc. complete all as specified and directed by the engineer-in-charge.
M & L for ASTM (uPVC) D 1785 / Sch 80 pipe, conforming to IS 4985: 2000, with all fittings fixed to walls and ceilings or laid in floors complete as specified and directed by the engineer-in-charge. NOTES:- [i] All hangers, clamps, brackets etc. shall be of galvanized iron. [iii] Welding of any kind on the galvanised support / hanger shall not be permitted. (a) 32 mm NB
(b) 25 mm NB
M & L for PN 1.6 rated 200 mm NB polypropylene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed by the engineer-in-charge.
S & F of PN 1.6 rated full bore, 25 mm NB two piece design, quarter turn, lever operated brass ball valve having nickel-plated forged brass body & end connector, brass chrome plated ball, PTFE body seat ring & packing, H.T. brass stem, nut & gland, rubber 'O' ring, powder coated MS lever and screwed female ends, etc. with accessories complete as specified and directed by the engineer-in-charge.
M & L for FM approved and UL listed 25 mm NB compact 3 position ball valve with drain orifice (test and drain valve) to test and drain water flow through sprinkler systems having OFF-TEST-DRAIN position, integral sight glass, rated pressure 300 psi, orifice size 15 mm and K factor 5.6, conforming to NFPA 13, along with necessary accessories complete as specified and directed by the engineer-in-charge.
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as specified and directed by the engineer-in-charge.
S & F HFC based Clean Agent (stored pressure) 4 kg Fire Extinguisher, applicable on Class A, B, C and electrically started fires, conforming to IS 15683: 2006 and filled with electrically non-conductive, non-corrosive, colourless and non-residual HFC 236fa gas, with nominal charge of 4kg (±5%) constructed of MS sheet by MIG welding process and brass forged discharge valve having approved fire ratings 1A:13B with an effective throw of about 3.5 m and discharge about 98% complete all as specified and directed by the engineer-in-charge. The Fire Extinguisher shall conform to the following technical parameters: [A] Materials of Construction (i) Extinguishing Medium: HFC-236a Clean Agent Gas (ii) Body: Mild Steel Sheet having max. 0.25% C, 0.05% P and 0.05% S (iii) Neck Ring: MS Pipe (iv) Valve: Brass (v) Siphon Tube: Plastic (vi) Pressure Gauge / Indicator: As per IS 15683: 2006 (vii) Wall-mounting Bracket with Screw: MS Powder Coated (viii) Discharge Hose with Nozzle: Rubber Braided EPDM Hose (length 465 mm) with PVC nozzle [B] Performance (i) Performance Requirement: 1. Minimum Effective Discharge Time: 13 s 2. Bulk Range of Discharge: 2 m 3. Percentage Discharge: > 95% (ii) Temperature Range: -20 °C to +55 °C (iii) Fire Rating: 1A:13B (iv) Service Pressure: 10 bar (v) Maximum Service Pressure: 15 bar [C] Routine Test (i) Pressure Test: 35 bar (ii) Minimum Burst Pressure Test for Body: 55 bar (iii) Leakage Test: Leakage tested by applying soap solution and in inverted glass jar (iv) Partial Discharge Test: The second pressure or weight shall not be less than 75% of the first after interruption of the discharge (v) Burst Pressure Test for Discharge Hose: > 35 bar [D] Type Tests (i) Resistance to temperature changes (ii) Impact test (iii) Vibrations test (iv) Corrosion test (v) Tapping test (vi) Intermittent discharge (vii) Maximum Service Pressure (viii) Crushing test (ix) Pressure cycling
S & F 6 kg capacity dry chemical powder (ABC) type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket / floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed by the engineer-in-charge.
S & F of 4.5 kg light-weight squeeze grip CO2 type fire extinguisher, conforming to IS 15683: 2006, with CO2 gas filled in brand new seamless cylinder with powder coated finish, made out of Manganese steel with wheel type valve, discharge nozzle, bend & horn, wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge.
S & F of 9 litre mechanical foam type fire extinguisher, conforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted with gunmetal union, high pressure CO2 gas cartridge, hose and ABS type branch pipe and wall mounting bracket / floor trolley mounting accessories along with suitable signage complete all as specified and directed by the engineer-in-charge.
S & F Galvanized mild steel Fire bucket (FILLED WITH DRY SAND) conforming to IS 2546: 1974 round bottom type enamel painted, white inside & Red out side and Letter "FIRE" in black out side and handle with mounting bracket complete as specified and directed by the engineer-in-charge.
S & F of the following type of signages made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed by the engineer-in-charge.
Sign of size 250 mm X 300 mm reading 'IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE' in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level
Sign of size 150 mm X 600 mm, posted and maintained within each stair enclosure on every floor, indicating the number of the floor in bold type and at 75 mm high numerals in red and white background, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level
Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level
M & L for Construction of fly-ash brick masonry valve chamber of size 1000 mm X 800 mm X 1000 mm (internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick fly-ash brick masonry walls built in CM 1:6, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC cooping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc. complete as specified and directed by the engineer-in-charge.
COOLING APPLIANCES:- Supply, installation, testing and commissioning of 1-Ph electric motor driven storage type water cooler having in-situ PUF insulation, (CFC free) eco-friendly R-134a refrigerant, high efficiency heat transfer coil of high quality copper tubes with rippled aluminum fins, stainless steel tank, trough and faucets, hermetic type compressor with suction gas cooled motor & equipped with overload protector, propeller type (quiet) condenser fan, thermostat, pre-coated partial stainless steel outer body and food grade plastic parts suitable for nominal cooling capacity and storage capacity 80/40 litres conforming to IS 1475 (Part-1): 2001 complete all as specified and directed by the Engineer-in-charge.
Supply, installation, testing and commissioning of 1-Phase mainline voltage stabilizer of 2 kVA rating having input voltage range 90 V to 300 V and output voltage range 180 V to 250 V and conforming to IS 8448: 1989, complete all as specified and directed by the Engineer-in-charge.
ELECTRIC INCINERATOR:- Supply, Installation, testing and commissioning of Portable type Eac Electric Incinerator complete with SS 304 having combustion Job chamber supported with electric coil having burning capacity 50 KG /Batch (average burn out time 1.0 hour), operating voltage 220/440 volts, comprising with the following (a) Burning/Combustion Chamber:-Incinerator has a combustion chamber, completely made of Stainless Steel (304 Grade). (b) Electric Hot Plate: Electric Incinerator should be fitted with hot plate for easy burning of the wet wastes. A blower fan is also provided for supply of oxygen contained in the atmospheric air for easy combustion of waste inside the incinerator. (c) Bottom Side Opening:- The Cyclone Chamber has a conical shape for easy discharge of ash to the sides of the incinerator. The Ash falls to an SS tray for easy collection and disposal. Quality of ash depends on the type of materials that are burned. Sticky materials like rubber, plastics etc when burned, has every tendency to clog the bottom openings. (d) Ash Tray: Bottom Ash Tray is also made of SS 304 grade material and is designed in such a way that it can accommodate complete ash of the day. (e) Chimney made of 33 304 material of 6 Mtrs Height (f) Control panel for auto operation as per OEM specification. (g) Supply of Other Auxiliary equipments are as under:- (i) Safety Googles - 02 sets (ii) Working Gloves - Heat resistant-02 Sets (iii) Pedal Bins Infectious Waste 30 liter - 02 Nos (iv) Collection bin grey/black 50 liters - 02 Nos (v) Collection bin yellow 50 liters - 02 Nos (vi) Garbege hand Cart/Trolley 50 liter - 01 Nos Note:- Specification of all other standard items/parts of electric incinator shall be as per OEM.
The Passengers lifts shall conform to the following technical specification. [i] Type of Lift: Passengers Lift/Service/Fire lift [ii] Load Capacity: 884 kg / 13 Passenger [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3- Phase, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: VVVF Regenerative Drive (Variable Voltage and Variable Frequency Regenerative Drive) [vi] Type of Machine: Gearless [vii] Car Size: Not less than 2.06 m² [viii] Car & Landing Door at all Floors: Automatic center opening with VVVF door drive, opening size not less than 900 mm X 2100 mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304) [ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings with auto cut-off system operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial/cross flow fan with auto cut-off system and stainless steel grill / wiremesh for protection [x] Handrail: Standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin. [xi] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (Inside): Centre opening stainless steel doors with hairline finish doors with clear opening of 900 mm X 2100 mm and protected by infrared door protection system. [xiii] Car & Counter Weight Guide: Guide rails of MS 'T' section as per OEM design; counter weight shall be as recommended by OEM. [ixv] Flooring: granite flooring & toe guard of adequate depth / as per OEM design. [xv] Signals: [a] Combined luminous hall buttons with LED / LCD hall position indicators of stainless steel at all floors.
The lifts shall conform to the following technical specification. [i] Type of Lift: Goods Lift [ii] Load Capacity: 2000 kg [iii] Speed: 0.5 m/s with single speed motor [iv] Power Supply: 3- Phase, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: VVVF Regenerative Drive (Variable Voltage and Variable Frequency Regenerative Drive) [vi] Type of Machine: Gearless [vii] Car Size: Not less than 4.10 m² [viii] Car & Landing Door at all Floors: Automatic center opening with VVVF door drive, opening size not less than 900 mm X 2100 mm, sliding type, fabricated by stainless steel sheet not less than 16 gauge having hairline finish (N-304) [ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless false ceiling with hairline finish, internal lighting arrangement with LED light fittings with auto cut-off system operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial/cross flow fan with auto cut-off system and stainless steel grill / wiremesh for protection [x] Terminal Buffers: Metal special spring/PU/Oil buffers as per manufacturer specifications. The buffing stroke shall not be less than 200 mm. [xi] Door Opening (Inside): Centre opening stainless steel doors with hairline finish doors with clear opening of 900 mm X 2100 mm and protected by infrared door protection system. [xii] Car & Counter Weight Guide: Guide rails of MS 'T' section as per OEM design; counter weight shall be as recommended by OEM. [xiii] Flooring: As per OEM design.
M & L for 1.1 kV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. (a) 4 core 16 mm², 2XWY
(b) 4 core 10 mm²,
(c) 4 core 6 mm2 , 2XWY
S & F of wall-mounted bulkhead having LED light source engine, integral fixed output driver,120° luminaire light beam spread, luminous flux ≥ 700 lm, luminous efficacy ≥ 107 lm/W, power consumption ≤ 6.5 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, power factor (fraction) > 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 25000 hrs, surge protection level ≥ 2 kV with aluminum die cast housing, polycarbonate optical cover / lens, IP65 & IK08 protection, and suitable for mounting on normally flammable surfaces, 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class I safety, along with wall-mounting bracket and all necessary accessories complete all as specified and directed by the engineer-in-charge.
SECURITY WALL AND GATE:- S&F Galvanised steel punched type concertina coil 610mm dia (in stretched position) with number of circles 80 Nos of 200 clips with weight 7.5 to 8 Kg/Coil and recommended average coverage is 6.00 RM per coil, hot dip galvanized steel wire coated with CLR anticorrosive paint, making diamond shape with the help of dove tail clips (18 SWG) fixed over barbed wire with angle iron. The concertina coil is to be fixed with barbed wire at points wherever coil touches the bottom of barbed wire with the help of hog rings (14 SWG), complete all as specified and directed.
M&L for granules textured homogenous wall finishing system consisting of a two component system of dry granules(25 Kgs per pack) made of 92% silica particles coated with fade resistant pigments,100% acrylic polymer bonding agent (5 Kgs per pack) with the applied thickness of the coating being between 0.8-1.20 mm to be applied on a cured ,smooth level plaster without keying as per the shades/combinations approved as per the manufactures instructions for usages to be applied by the approved applicator of the manufactures, as per the direction/supervision of the Eng-In-Charge all complete.the above textured coating should confirm to surface spread of flame clause one of BS-476:1971 and pull off strength of the coating to meet JISA 6909on smooth plastered surface complete all as specified ans as manufacture specifications including 15 mm thick plaster(5 mm thick using WPC in (1:4) on 10 mm thick in CM(1:6) finished even and smooth complete all as specified and directed.
AREA DRAINAGE:- Supply & Fixing Precast cement concrete drain of size 0.60 m x 0.6 m including Perforated drain cover slab of make M/s: Fuji silvertech/Alcock/Teamage or equivalent, and pointing the joints in CM(1:3) and all as specified and as directed.
ROAD/FOOT PATH/CULVERT:- M&L wet mix macadam (WMM) 150 mm thick (Compacted thickness) in two layers 75 mm each with granite stone coarse aggregate of specified grade spread using mechanical paver as required gradient and camber all as specified and directed.
M&L for 100 mm Compacted thickness dry lean concrete (DLC) with 7 days compressive strength 10 Mpa by paver rolling as specified and directed.
Supply and lay one layer polythene film transparent 400 micron HDPE sheet.
M&L for pavement quality concrete (PQC) of flexural strength 45 Kg/Cm2 in field using minimum 415 Kg of cement per cum as per design mix thickness of concrete 200 mm thick laying in bays as specified on drgs and adding 1 Kg/Cum of non circular synthetic fibre complete using computerized concrete batching plant with sensor paver all as spd and as directed.
Delinator twin reflector made out of polycarbonate and toughened aluminium alloy body of size 700x100x50 mm made out of MS pipe of 51 mm dia and mounted on oval shaped metal plate of dimensions 302x167 mm fitted with two nos 110 mm dia high reflective reflectors in both sides alongwith 2 Nos 70x23 rectangular reflectors each side for excellent reflectivity in the night hours
S&F reflective road studs made out of tough polycarbonate and its reflective lance shall be made with polycarbonate microprismatic, retro reflective lance electronically welded to the body of stud and overall size 90mm x100mm x18 mm, the lower surface of studs will be supported with 2 Nos nylon shanks each of length not less than 20 mm and load bearing capacity 20 ton and fixed with epoxy adhesive in road complete all as per manufactures instructions.
S&F solar reflective road studs made out of tough polycarbonate and its reflective lance shall be made with polycarbonate microprismatic, retro reflective lance electronically welded to the body of stud and overall size 90mm x100mm x18 mm, the lower surface of studs will be supported with 2 Nos nylon shanks each of length not less than 20 mm and load bearing capacity 20 ton and fixed with epoxy adhesive in road complete all as per manufactures instructions.
M&L for thermoplast painting on road marking, line,arrows, square etc, thickness of thermoplast painting not less than 1mm thick complete all as specified and directed. Note :- Application of painting will be carried out by mechanical painting machine as specified.
S&F Convex mirror of size 800 mm dia of PC material provided with suitable MS pipe post should have clear and definite mirror image having 130 degree of viewing.
S&F Heavy ABS plastic speed breaker of size 750x75x250 mm with two highly reflective reflectors moulded in PMMA material are welded with ABS plate through ultrasonic welding process and then fixed on the speed breaker. Speed breaker to be fixed with epoxy and hardener and bolts.
M&L for Granite Cobblestone pavers any shape and size as approved by GE.
AIR CONDITIONING:- Supply, installation, testing and commissioning of factory designed, pre-fabricated and floor-mounted AHRI certified screw type water-cooled chiller machine of actual capacity ≥ 150 TR, complete with semi-hermetic / hermetic screw compressors having single refrigerant circuit and automatic stepless capacity control, water-cooled S/T type condenser, as per ASME / BIS horizontal flooded type evaporator with carbon steel shell and seamless copper tubes with elastomeric insulation, suitable numbers of squirrel cage induction motors of appropriate rating with class 'B' insulation, etc. Unit mounted variable frequency drive (VFD) along with necessary drive arrangement, lubrication system as per manufacturer's design required for smooth and trouble-free operation of the chiller package, common base-frame, interconnected copper refrigerant piping along with elastomeric insulation, fittings, valves, expansion valves and accessories to interconnect compressor, condenser, chiller and expansion valve, microprocessor based control panel comprising of controls including sensors and equipped with a keyboard, LCD touchscreen access input system, protection and monitoring devices to perform control functions, wiring, vibration isolators, gauge panel, automatic safety controls, flow switch at evaporator and condenser connection ends and ozone friendly, CFC-HCFC free refrigerant complete all as specified and directed by the engineer-in-charge. The chiller shall conform to the following requirements / specifications: [i] Chilled water inlet/outlet temperature: 54/44 °F [ii] Evaporator fouling factor: 0.00050 ⁰Fft²hr/Btu [iii] Evaporator side pressure drop: 6 ft of H2O (maximum) [iv] Condenser water inlet/outlet temperature: 90/97.5 °F [v] Condenser fouling factor: 0.001 ⁰Fft²hr/Btu [vi] Condenser side pressure drop: 10 ft of H2O (maximum) [vii] Minimum COP @ 100% load: 6.0 at AHRI condition [viii] Minimum IPLV : 9 at AHRI condition [ix] Minimum NPLV: 0.39 at Site Conditions [x] Maximum Cooling ikW/TR @ 100% load: 0.68 [xi] Refrigerant (Ozone friendly type): R134a [xii] Test standard: ARI 550 / 590
Supply, installation, testing and commissioning of self-priming, single-stage, centrifugal, monoset pump (chilled water circulation pump) suitable for 32 litre/s discharge @ 60 mWC head, conforming to IS 9079: 2018 & tested as per IS 5120: 1977 having cast iron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings, etc. with TEFC squirrel cage induction motor, conforming to IS 12615: 2018, and suitable for operation on 3-Ph, 415 V±10%, 50 Hz AC supply, base plate, mounting channel frame, accessories and fittings, viz. pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting duly insulated with FM approved highly- flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of appropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim along with adhesives and other necessary accessories complete all as specified and directed by the engineer-in-charge. NOTES:- [i] Necessary civil work viz. foundation for placement of pump and pump accessories shall be covered in the scope of work. [ii] Pressure gauges, thermometers and drains shall be measured and paid for saperately. [iii] The contractor shall verify pump head before placing the purchase order of pumps.
S & F of ASME pre-charged vertical closed bladder expansion tank of 200 litre size, stamped for 125 psi (862 kPa) working pressure having carbon steel shell, conforming to IS 2825: 1969, coated (inside & outside) with anti-corrosion paint with a heavy-duty butyl replaceable bladder, ring base, lifting rings, and 20 mm NPT piping connection protected by strainer at the water inlet, air charging valve connection to facilitate adjusting pre-charge pressure to meet actual system conditions complete with accessories as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of horizontal split-casing single stage single suction pump having flowrate ≥ 49 litre/s @ 16 mWC head for condenser water conforming to IS 6595 (Part 2): 1993 and having horizontal axially split volute type CI delivery casing, suction and discharge nozzles and supporting feet cast integral with lower half casing, enclosed balanced bronze impeller, high tensile steel (CS) shaft supported by antifriction bearing and protected by bronze shaft sleeves in stuffing box area sealed by mechanical seal, deep groove ball / roller bearing, standard drilling flanges etc. suitable for direct coupling with TEFC squirrel cage induction motor suitable for operation on 3-Ph, 415 V±10%, 50 Hz AC supply and conforming to IS 12615: 2018, base plate, mounting channel frame, accessories and fittings, viz. pressure gauge, drain, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting and foundation as per manufacturer's recommendation and other necessary accessories complete all as specified and directed by the engineer-in-charge. NOTES:- [i] Necessary civil work viz. foundation for placement of pump and pump accessories shall be covered in the scope of work. [ii] Pressure gauges, thermometers and drains shall be measured and paid for saperately. [iii] The contractor shall verify pump head before placing the purchase order of pumps.
[iii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos.(b) 800/5A Cl. 1.0 C.T. with 15 VA burden- 01 Nos. (c) 800/5A Cl. 5P10 C.T. with 15 VA burden- 01 Nos. (d) 415/√3 V / 110/√3 V P.T. Cl.3P, 50 VA burden- 01 Nos. (e) 6A, 10kA, 415V, 50 Hz 4P MCB- 02 Nos. [iv] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set (c) LED status indicators (SC, CSH, RTC)- 01 Set [C] OUTGOING:- [i] Circuit Breaker (a) 400 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having microprocessor based trip unit, adjustable overload setting, adjustable short-circuit setting, adjustable neutral protection, electrical interlocking, front indication LEDs, etc.- 03 Nos. (b) 160 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 04 Nos. (c) 125 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos. (d) 80 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 03 Nos. [ii] Motor Starter / Drive (a) Variable Frequency Drive (VFD) of 37 kW rating with IP 55 enclosures and mains disconnect switch and comprising of the following complete with accessories of ABB, Danfoss, L&T E&A or Schneider make- 04 Nos. (1) built-in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the variable frequency drive (VFD). (2) built-in EMC filters (electro magnetic compatibility filters) for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution): 2004 category C 1 (50 meter) (3) three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of pumps. (4) integral graphical keypad.
M & L for 1.1 kV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge.
4 core 70 mm2 , 2XWY
3 core 25 mm2 , 2XWY
3 core 10 mm2 , 2XWY
S & F of perforated hot dipped galvanized iron cable tray having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittigs viz. joints, bends, tees, etc. in convenient sections of length complete all as specified and directed (a) 300 mm X 50 mm X 1.6 mm
(b) 150 mm X 50 mm X 1.6 mm
(c) 100 mm X 50 mm X 1.6 mm
M & L for condenser water piping including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories complete all as specified and directed by the engineer-in-charge. NOTES:- [i] The pipe size 150 mm NB & below shall be MS Class 'C' as per IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and up to 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB and above.
(a) 300 mm NB
(b) 250 mm NB
(c) 200 mm NB
Supply, installation, testing and commissioning of PN 1.6 rated 250 mm NB POT strainer, conforming to BS 6755-1, suitable for high capacity flow throughout full size inlet / outlet, having CI body & strainer bonnet, stainless steel perforated filter section, black rubber body / bonnet gasket, SS-410 valve and flange drilling standard end connections, etc., with accesories all as specified and directed by the engineer-in-charge.
M & L for PN 1.6 rated wafer type, short / medium pattern cast iron (CI) butterfly valve, conforming to IS 13095: 2020, certified for body test pressure 2.4 MPa Hyd. and seat test pressure 1.6 MPa, having CI Gr. FG200 body conforming to IS 210: 2009, seat having EPDM / nitrile rubber lining, SG iron / ductile cast iron disc, SS AISI-410 stem, flanged end connection, conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125 with necessary accessories complete all as specified and directed by the engineer-in-charge. (a) 250 mm NB
(b) 200 mm NB
M & L for PN 1.6 rated straight type 200 mm NB cast iron (CI) reflux (non-return) valve, conforming to IS 5312-2: 1986, having CI Gr. FG200 body conforming to IS 210: 2009, bolted cover, integral / renewable seat, renewable disc, gunmetal trim with rubber seat ring, flanged end connection, conforming to IS 1538: 1993 with necessary accessories complete all as specified and directed by the engineer-in-charge.
M & L for chilled water piping including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulated complete all as specified and directed by the engineer-in-charge. NOTES:- [i] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239-1: 2004 & IS 1239-2: 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and up to 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB and above. [iv] Insulation shall be measured and paid for separately.
(a) 125 mm NB
(b) 20 mm NB
(c) 15 mm NB
Supply, installation, testing and commissioning of maintenance-free PN 1.6, 15 mm NB, rated 3-way diverting globe valve for modulating water-side control of air handling units (For diverting application) along with valve actuator complete all as specified and directed by the engineer-in-charge. The valve and actuator shall conform to the following technical specifications:- [1] Valve: (i) Body: Ductile iron GGG40 (ii) Valve Cone: SS304 (iii) Valve Stem: SS630 (iv) Valve Seat: SS304 (v) Stem Seat: PTFE & FFKM (vi) Flow Media: Chilled Water (vii) Rangeability: 100:1 (vii) Rangeability: 100:1 (viii) Leakage Rate: Max. 0.02% on all path [2] Actuator: (i) Nominal Voltage: AC / DC 24 V (ii) Nominal Frequency: 50 Hz (iii) Power Consumption in Operation: 2 W (iv) Power Consumption in Rest Position: 1.5 W (v) Actuating Force Motor: 1.5 kN (vi) Operating Range: Y: 0.5… 10 V (vii) Input Impedance: 100 kΩ (viii) Position Accuracy: ±5% NOTES:- [i] The 3-way diverting globe valve shall be pre-calibrated to the given maximum flow rate. [ii] Closing off differential pressure of actuator connected with 3-way diverting globe valve shall not be less than the pump head.
M & L for CL#125 15 mm NB, two-piece design cast iron (CI) straight pattern ball valve, conforming to IS 9890: 1981 and having FG 200 cast iron body conforming to IS 210: 2009, AISI 410 stem, stainless steel AISI 304 ball, renewable PTFE seat & gland packing and screwed female BSP parallel threaded ends conforming to BS 21, duly insulated complete all as specified and directed by the engineer-in-charge.
S & F of flexible closed-cell elastomeric thermal insulation (in tubular form) made of elastomeric foam based on synthetic rubber (NBR / PVC), tested for maximum service temperature 100 ºC as per ASTM C534 & minimum service temperature -50 ºC as per ASTM C534, thermal conductivity λ ≤ 0.037 W/mK at mean temperature θm = 24 ºC as per ASTM C518 / C177, ASTM C335, water absorption by volume ≤ 0.2% as per ASTM C 209 / C1763, flame spread index (FSI) & smoke development index (SDI) 25/50 as per ASTM E84, flammability HB, V-0 as per UL 94, fungi resistance as per ASTM G21/C1338, mould growth resistance as per ASTM E2180-18 / UL 181 and ozone resistance as per ASTM D 1149-18 along with self pre-covered self-adhering, UV treated glass cloth of thickness 7 mm / 200 GSM adhesives and other necessary accessories complete all as specified and directed by the engineer-in-charge. (a) 250 mm NB (32 mm thickness)
(b) 200 mm NB (32 mm thickness)
(c) 150 mm NB (32 mm thickness)
(d) 125 mm NB (32 mm thickness)
(e) 100 mm NB (32 mm thickness)
(f) 80 mm NB (25 mm thickness)
(g) 65 mm NB (25 mm thickness)
(h) 50 mm NB (19 mm thickness)
(j) 40 mm NB (19 mm thickness)
(k) 32 mm NB (19 mm thickness)
(l) 25 mm NB (19 mm thickness)
(m) 20 mm NB (19 mm thickness)
(n) 15 mm NB (19 mm thickness)
S & F of fire-retardant quality expanded polystyrene moulded pipe section (EPS) insulation of density 20 kg/m3, with a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessian and finally sand cement plaster and tar felt cladding complete with type, grade-1 roofing felt strip, conforming to IS 1322: 1993, at joints repairing of damage to building etc. for the following diameters as required complete all as specified and directed by the engineer-in-charge. (a) 200 mm NB (75 mm thick)
Supply, installation, testing and commissioning of DCBL cassette type (3' X 3') fan coil unit (FCU), having low height design (< 275 mm) round flow type 360° airflow, 3- air swing pattern control, draft prevention & soil prevention, turbo fan with BLDC motor, 5 levels of speed modes (HH / HM / M / ML / L), 20% fresh air intake hole, built-in high head drain sump & water flow switch, etc. complete all as specified and directed by the engineer-in-charge. (a) 1.25 TR; 472 CFM
(b) 1.5 TR; 512 CFM
(c) 2.0 TR; 750 CFM
(d) 2.25 TR; 804 CFM
(e) 2.5 TR; 942 CFM
(f) 2.75 TR; 962 CFM
(g) 3.0 TR; 1160 CFM
(h) 3.5 TR; 1223 CFM
(j) 3.8 TR; 1268 CFM
Supply, installation, testing and commissioning of automatic air-vent valve with 20 mm end connections, brass body and cover, plastic float, brass cap etc. suitable for maximum operating pressure of 16 bar and maximum operating temperature 100 °C respectively, installed on all high points in the water piping system to automatically remove the trapped air complete all as specified and directed.
S & F of 6" dual scale (°F/°C), lower mount (radial), bimetal thermometer having 0.5 NPT process connection, Grade A accuracy class as per ASME B40.200, stem diameter 6.35 mm, laminated safety glass window, stainless steel 304 case, steam, process connection & joint, aluminium dial & pointer, IP67 protection, scale range 0- 60 °C complete with accessories, etc. as specified and directed by engineer-in-charge.
S & F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed by engineer-in-charge.
M & L for mild steel electric resistance welding class-C drain water piping including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessories, duly insulated complete all as specified and directed by the engineer-in-charge. (a) 15 mm NB
(b) 25 MM NB NOTE for (a) & (b) above :- [i] The pipe size 150 mm NB & below shall be MS 'C' class as per IS 1239 (Part- 1): 2004 & IS 1239 (Part- 2): 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS 3589: 2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and up to 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB and above.
S & F of PN 25 rated forged brass ball valve, having lever operated two piece design, renewable P.T.F.E. seat, brass ball, machined brass nickle plated stem, P.T.F.E. packings, full bore port opening, screwed female BSP parallel thread end connections, body test pressure 40 kg/cm2g Hyd. and working pressure 25 kg/cm2g Hyd. duly insulated with elastomeric thermal insulation with adhesives and other necessary accessories complete all as specified and directed by engineer-in-charge. (a) 15 mm NB
(b) 25 mm NB
Supply, installation, testing and commissioning of insertion type flow sensor with a non-magnetic, spinning impeller (paddle wheel) as the only moving part) with sensor sleeve of brass (or SS316) with PPS housing, glassfilled nylon or Tefzel impeller with a UHMPWE or Tefzel sleeve bearing, tungsten carbide shaft, 2” NPT adapter having two ethylene-propylene O-Rings for installation into any commercially available weld-on fitting or pipe saddle, all electronics epoxy-sealed with a 2-conductor shielded cable extending out through a ½”conduit connection on top of the sensor, etc. operating in line pressures up to 400 psi and liquid temperature up to 220 °F and flows of 1 fps to 30 fps in pipes of 3” diameter up to 40” diameter with linearity of +1% and repeatability of +1% complete all as specified and directed by the engineer-in-charge.
EXTERNAL WATER SUPPLY Supply, installation, testing and commissioning of Monoblock, self-priming, single-stage centrifugal pump, capable of 9.2 LPS discharge at 52 mWC head in (1W + 1S) configuration, having castiron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings, etc. with SPDP squirrel cage induction motor having class 'B' insulation, IE3 efficiency, conforming to IS 12615: 2018 and suitable for operation on 3-Ph, 415 V±10%, 50 Hz AC supply, base plate, mounting channel frame, accessories and fittings, viz. pressure gauges, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting along with accessories complete all as specified and directed by engineer-in-charge. The pumpset shall include the following: [i] Vaccum gauge -01 Nos. [iI] Priming arrangement of pump set by providing GI pipe 20 mm dia medium grade, gate valve etc from near by existing line with all fittings etc complete - 1 Job NOTES: [i] Necessary civil work viz. foundation for placement of pump and accessories shall be covered in the scope of work.
M & L for PN 1.6 rated 100 mm NB swing type foot valve cum strainer, conforming to IS 4038: 1986, suitable for vertical installation and having cast iron body, guide & strainer, soft grade iron plunger, SS spring, bronze seat ring, CS fasteners, flange drilling standard end connection and accessories complete all as specified and directed by engineer-in-charge.
S & F of 25 mm NB SS 304 ball valve, having two piece design, SS 304 body & ball, PTFE seal/packing/gasket and screwed/socket weld end connection, etc. with accessories complete all as specified and directed by engineer-in-charge.
Material and labour for construction of 900 mm X 900 mm X 900 mm valve chambers including excavation and earthwork. PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type Freshwater Supply Panel (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge.
(a) LED status indicators (ON, OFF, TRIP)- 04 Set [v] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 04 Set NOTES: [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 4b. [ii] ACBs shall have separately powered, individual fault trip indication LEDs (For overload, short circuit, earth fault and trip-unit failure) shall be available on the trip unit which shall function even in the absence of external power supply to the breaker.ACB shall be suitable for ZSI. Trip units shall have thermal memeory as standard. [iii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iv] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [v] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V. [vi] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vii] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [viii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative. [ix] The Contractor shall intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
S & F of 100 mm X 50 mm X 1.6 mm (L X D X T) size of perforated painted with powder coating MS cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts, etc. complete all as specified and directed by engineer-in-charge.
S&F LED luminaire 6W (2700K), Compact and aesthetic polyester coated aluminium housed in ground/bushlight offers safe and vibrant parking area, pathways and gardens with high illumination, including fixing arrangements etc complete all as specified and directed. Make : Wirpo cat No. LF05-450-036-27-XX or its equivalent in Philips/Bajaj
S&F LED flood lights 12W, CCT 3000 Aluminium die cast housing with purity lense for facade lightning with glare free light distrubition enhancing accent lighting, including fixing arrangements etc complete all as specified and directed. Make : Wirpo cat No. LF04-181-030-30-XX or its equivalent in Philips/Bajaj
S&F DMX Controller, IP67 Plug-socket S connector, 3-Channel Main Controller 24/ 48VDC input/output, max. 360W(24/ 48V) and accesories complete all as specified and directed. Make : Wirpo cat No. LG70-360-3M-24V or its equivalent in Philips/Bajaj
S&F DMX Driver and accesories etc complete all as specified and directed. Make : Wirpo cat No. LPV-150-24 or its equivalent in Philips/Bajaj
Supply, testing and commissioning of Openwell submersible pump set of discharge capacity 2000 LPM at 18 mtr head of 5 HP (3.7 KW), 3000 rpm, 3 phase 415 volts, 50 Hz, mounted on MS chanel/common base plate and fixed with suitable bolts, grouted in PCC foundation, 30 CM above floor level including PVC insulated single core unsheathed copper conductor of 4 sqmm 3 core size drawn in PVC conduit for connection from starter to motor terminal, including the following accessories.
BOREWELL:- Material and labour for drilling PILOT(Trial) borewell by Directory Rotary rig method in any type of soil/hard/ rock/soft rock including watering for drilling process complete all as specified for following depths :- (a) From 0 to 50 mtr below ground level
(b) From 51 to 100 mtr below ground level
(c) From 100 to 150 mtr below ground level
(d) From 151 to 200 mtr below ground level
(e) Above 200 Mtrs below ground level
M&L for development / enlargement trial bore well by reaming in 250 mm to 350 mm upto 525 mm from groung level including watering for drilling process complete all as specified for the following depths :- (a) From 0 to 50 mtr below ground level
(b) From 51 to 100 mtr below ground level
(c) From 100 to 150 mtr below ground level
(d) From 151 to 200 mtr below ground level
(e) Above 200 Mtrs below ground level
Note:- The following tests and reports will be carried out by the contractor as per IS 2800 part I 1991 as directed by Engineer-in-Charge. (a) Recording the well discharge during drilling by a V notch. (b) Recording the water Bearing horizon. (c) Taking the samples from the bore wells during drilling for every 3 meter interval and every change in strata if less than 3 meter. (d) Preparation of litho logs based on these samples. (e) Drill time log to be prepared and prescribed. (f) Interpretation of data and preparation of hydro scientific report for designing of submercible pump and artificial discharge studies.
Supplying, assembling and lowering 250mm nominal bore mild steel ERW ISI marked casing blank pipe having wall thickness 8mm as per IS-4270-1992 including fixig of MS clamp on pipe end jointing with electric arc welding, screwed and socketed in random length of 3 to 6 meter, including necessary fittings i.e. steel sockets, coupling, jointing and painting with two coats of bituminous paint over a coat of red oxide primer of external surfaces of pipe upto maximum depth of 180 metre below ground level complete all as specified and directed.
Supplying, assembling and lowering 250mm nominal bore MS ERW fine cut pipe having wall thickness 8mm slotted pipe conforming to IS-4270-1992 with slot of suitable size and numbers as per location of intermediate aquifers, complete all as specified and directed.
Supply, lowering and packing pea gravel of size 2 mm to 6 mm duly screened and washed around the casing pipe and slotted pipes in bore complete all as specified and directed by Engr-in-Charge. Note : For the purpose of measurement, gravel brought by the contractor shall be stacked properly at site & measurement of stack shall be carried out before use & after use (left un-used) to arrive at the net qty of gravel used by the contractor in the work & the payment against this item shall only be made for the qty of gravel used in the work & not for the total qty of gravel brought at site.
Supply, installation, testing and commissioning of submersible pumping set of discharge capacity ranging from 400-600 LPM at a head range of 120-150 metre head, suitable for a bore of 100 mm dia including 3 phase,50 Hz, 415 Volts electric motor of suitable capacity including MS adopter or reducer and all accessories etc for proper functioning of pumping set complete all as specified and directed by Engr-in-Charge.
Supply, jointing and lowering of galvanised iron, heavy duty flanged column pipe 80 mm dia, ISI marked, 3 metre length each duly flanged at both ends by welding with special provisions such as MS supporting clamps slots for housing 02 Nos. submersible cable including nuts, bolts, washers and rubber gaskets etc complete all as specified and directed by Engr-in-Charge. Submersible cable will be measured and paid separately in respective item of this schedule.
Supply, laying, jointing & testing submersible cable PVC insulated, multistranded, flat 16 Sq mm 3 core copper conductor suitable for working voltage 1100 volts including connections to motor / starter complete all as specified and directed by Engr-in-Charge.
Supply and fixing 6 mm thick bail plug of mild steel, 250 mm dia with strong iron hook, screwed and welded in casing pipe complete all as specified and directed by Engr-in-Charge.
Supplying, fixing and lowering of MS centering guide into bore well, made out of flat MS rings/ribs suitable for 250 mm dia MS casing pipes as specified in IS code No. 2800 Part-I of 1991 complete all as specified and directed by Engr-in-Charge.
Supply and fixing MS reducer having wall thickness 8 mm screwed at both ends of size 350 x 250 mm including necessary fittings, fixing support and jointing at appropriate length complete all as specified and directed by Engr-in-Charge.
Supply and fixing well cap for 350 mm bore pipe having internal and external threading with rings, ribs and welded iron handle, suitable for casing pipe all as specified in IS code 2800 Part-I of 1991, complete all as specified and directed by Engr-in-Charge.
Development of bore well by means of compressor of capacity not less than 1000 Cubic Metre/Hour and 600 PSI till sand free clear water is obtained and stabilization of the tube well including yield test indicating static water level, draw down and yield test by V notch method and submitting the test report complete all as specified and directed by Engr-in-Charge.
Supply only strata sample box made out of 19mm thick both side prelaminated interior grade particle board and 12mm thick BWR ply wood with 25mm x 25mm aluminium angle 2mm thick Overall size 1800 mm x 750mm x 100mm with front ordinary glass sheet (3 mm thick) sliding type cover with aluminium frame all around 2 Nos keys holes plate of size 40 mm x 25 mm and 3 mm thick complete showing name of tube well location and starta chart complete (duly glass framed with wooden beadings) showing depth including painting with two coats of synthetic enamel paint over a coat of pink primer all as specified and directed.
Testing of water for potability by chemical analysis such as PH value, dissolved solids, hardness as CaCO3, calcium, Magnesium, chlorides, sulphates, nitrate, alkalinity, iron, turbidity NTU, mineral oil, colour hazen units, taste, odour, residual free chlorine, total coliform per 100 ml (microbiological test) as well as bacteriological portability from any Govt. Laboratory and the report shall be submitted to the department complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing of Double Walled Corrugated Pipe(DWC) as UG Cable Pratection complete of Size 90/76 mm
Supply, jointing of Snap Fit Coupler for Double Walled Corrugated Pipe(DWC) as UG Cable Pratection complete of Size 90/76 mm
LIGHTENING PROTECTION :- M & L for 8.0 mm dia. Aluminum (Alu) round conductor, conforming to IS/IEC 62305-3: 2010 along with necessary accessories as recommended by the OEM / manufacturer, complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. RD 8-ALU I, Item No. 5450086 or equivalent of ABB, Erico, Dehn
S & F of cross universal connector made out of hot dipped galvanised iron, conforming to IS/IEC 62305-3: 2010, for 'tee' and 'cross' connection, to route vertical down conductor / mesh formation, with necessary screws and other accessories as required, installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 251 8-10, Item No. 5312035 or equivalent of ABB, Erico, Dehn
S & F of cable bracket (cable fixing device) / polyamide conductor holder for parapat (to be placed @ 1 m distance), with M8 female thread of dia. 7 mm, M8 screw to connect the conductor holder, weather and temperature resistant from -35 to 90 °C with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 177 30 M8 Item No. 5207460 or equivalent of ABB, Erico, Dehn
S & F of bonding base with threaded stem M8 for mounting cable supports with M8 female thread / bonding to concrete steel or brickwork with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 194 Item No. 5207258 or equivalent of ABB, Erico, Dehn
S & F of roof conductor holder for flat roof with double conductor holder (to be placed @ 1 m distance) having filling weight 1 kg (frost-resistant concrete), sleeve made of polyethylene, bottom made of polypropylene, base made of polyamide PA 6, UV stabilized and weather resistant with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 165 MBG-8-10 Item No. 5218700 or equivalent of ABB, Erico, Dehn
S & F of expansion piece for equalising temperature related length changes (necessary on conductor lengths over 20 m) for Alu round conductor with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 172 AR Item No. 5218926 or equivalent of ABB, Erico, Dehn
S & F of vario quick connector, conforming to IS/IEC 62305-3: 2010 for tee, cross and parallel connectors using hexagonal bolt M10X30, high-grade stainless steel with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 249 8-10 ST Item No. 5311500 or equivalent of ABB, Erico, Dehn
S & F of 10 mm dia. Alu tapered pipe air-termination rod, conforming to IS/IEC 62305-3: 2010 and suitable for wind loads as per Eurocode 1: DIN EN 1991-1-4, for vertical air termination with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 101 VL4000 Item No. 5401995 or equivalent of ABB, Erico, Dehn
S & F of stand for Alu tapered pipe air-termination rod, having tested up to 100 kA lightning current comforming to IS/IEC 62305-3: 2010, having base 16 kg stone of 365 mm dia. made of frost-resistant concrete to ensure high level of stability, suitable for quick and easy mounting of air-termination rod using anchors with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. F-FIX-16 Item No. 5403200 or equivalent of ABB, Erico, Dehn
S & F of concrete base for Alu tapered pipe air-termination rod, having tested up to 100 kA lightning current comforming to IS/IEC 62305-3: 2010, having minimum16 kg stone block of 365 mm dia. made of frost-resistant concrete to ensure high level of stability with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. F-FIX-S16 I Item No. 5450080 or equivalent of ABB, Erico, Dehn
S & F of stand including 10 mm dia. aluminum air-termination rod of 1 metre length, conforming to IS/IEC 62305-3: 2010 for quick mounting of the air-termination rod in the base using plug technology, with vario quick connector 249 and tested for electrical, mechanical and chemical stability as per IEC 62561-1: 2023 with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. F-FIX-JUNIOR Item No. 5403308 or equivalent of ABB, Erico, Dehn
S & F of UV stable bridging cable with aluminum cable lugs, from flexible copper cable of 16 sq.mm., having black coating of chlorinated EM5 natural rubber mixture, 1 fastening hole of 10.5 mm dia. & 2 fastening holes of 6.5 mm dia. per attachment side, suitable for applications outside/inside, tested for temperature range -25 to 80 °C (moved) and -40 to 80 °C (not moved) with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 853 300 Item No. 5331013 or equivalent of ABB, Erico, Dehn
S & F of clamping shoe made of hot dipped galvanised cast steel with 11.0 mm dia. attaching hole, 2 hexagonal bolts M8 X 16 made of hot-dip galvanised steel with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 319 8 Item No. 5325307 or equivalent of ABB, Erico, Dehn
S & F of folding clamp, conforming to DIN V VDE V 0185-3 Section 4.5, to standseam roof for round conductor with a diameter of 8 mm to 16 mm, made of hot-dipped galvanised steel and suitable for bonding and fixing horizontal round conductor, air terminal to stand seam sheet, suitable to fix for seam roof thickness up to 20 mm with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 270 8-10 FT Item No. 5317207 or equivalent of ABB, Erico, Dehn
M & L for 8.0 mm dia. Aluminum (Alu) round conductor with PVC sheathing, conforming to IS/IEC 62305-3: 2010 along with necessary accessories as recommended by the OEM / manufacturer, complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. RD 8-PVC, Item No. 5021332 or equivalent of ABB, Erico, Dehn
S & F of cable bracket (cable fixing device) / polyamide conductor holder for parapat (to be placed @ 1 m distance), with M8 female thread of dia. 7 mm, M8 screw to connect the conductor holder, weather and temperature resistant from -35 to 90 °C with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 177 30 M8 Item No. 5207460 or equivalent of ABB, Erico, Dehn
S & F of bonding base with threaded stem M8 for mounting cable supports with M8 female thread / bonding to concrete steel or brickwork with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 194 Item No. 5207258 or equivalent of ABB, Erico, Dehn
S & F of test joint (folding clamp), conforming to DIN V VDE V 0185-3, for conductor routing transverse and longitudinal to 5 mm thick plate, made of hot-dipped galvanised steel and suitable for connecting 8 mm dia. round conductor and maximum by 30 mm X 3 mm GI strip with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 271 8-10 VA Item No. 5317481 or equivalent of ABB, Erico, Dehn
S & F of lightning stroke counter, conforming to VDE 01885-561-6 (IEC 62651-6: 2018) to measure and permanently save pulse currents together with date and time, having cable clip for round / flat conductor, LED display, internal battery, IP65 protection, long lifespan of the internal lithium batteries, etc. with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. LSC I+II Item No. 5091722 or equivalent of ABB, Erico, Dehn
S & F of 30 mm X 3 mm hot-dipped galvanised steel flat conductor from earth electrode directly in ground, conforming to IS/IEC 62305-3: 2010, having cross-sectional area of 90 sq.mm, zinc coating 500 GSM (approx. 70 micron coating), tested and used exclusively for lightning protection earthing system and ring equipotential bonding with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 5052 DIN 30X3 Item No. 5450436 or equivalent of ABB, Erico, Dehn
S & F of cross connector for flat conductor, conforming to IS/IEC 62305-3: 2010, suitable for 30 mm wide GI strip, mounted with 4 hexagonal bolts M6 X 20 (F) with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 255 A-FL30 FT Item No. 5314534 or equivalent of ABB, Erico, Dehn
M & L for 1.1 mm thick (approx.) and 50 mm wide and 1000 m long corrosion protection tape, made of petrolatum-coated chemical fibre fabric with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 356 50 Item No. 2360055 or equivalent of ABB, Erico, Dehn
M & L for UL listed maintenance-free, low carbon, copper coated steel earth electrode of 3 m length and 14.2 mm dia. with copper coating thickness of 250 micron, conforming to IEC 625561-2: 2018 with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 14 3000 CCER Item No. 5450010 or equivalent of ABB, Erico, Dehn
M & L for earth conductivity enhancing material compound (25 kg bag), tested as per IEC 62561-7: 2018 with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. OCE-2-25 Item No. 5450058 or equivalent of ABB, Erico, Dehn
S & F of universal connection clip, made of stainless steel, for earthing systems on flat conductors, including hex-head screw for attaching flat conductors with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. 14 25 RTC Item No. 5450066 or equivalent of ABB, Erico, Dehn
S & F of heavy duty earth chamber (underfloor test box) without separating piece and having 5000 kg load bearing capacity to ensure safety of earthing system with necessary accessories complete all as specified and directed by the engineer-in-charge. Make: OBO Type No. UFE Item No. 5450030 or equivalent of ABB, Erico, Dehn
VENTILATION:- M & L for supply/return air grille of size 900 mm X 200 mm having welded steel border with aerodynamically shaped extruded aluminium blades having 30º fixed deflection & 20 mm blade spacing, countersunk screw holes in border, anodic acrylic paint finish, etc. and tested as per ANSI / ASHRAE standard 70-2006 complete all as specified and directed by the engineer-in-charge. Make: Air Flow, Caryaire, Dynacraft, Ravistar
Supply, installation, testing and commissioning of 40000 CFM CE certified / UL listed direct-driven VANE axial flow fan , conforming to EN 12201-3: 2015, at 35 mm static pressure having fan motor suitable for 3-Ph, 415 ± 10% V, 50 Hz power supply and minimum IE3 efficiency, Class ‘H’ insulation and Class ‘H’ smoke spill @ 250 °C for 2 hrs., mounting bracket and flexible connection for installation, total fan efficiency ≥ 70%, noise level ≤ 78 dBA @ 3 m distance for fans when measured in hemispherical reverberant room conditions, sound attenuators of appropriate length and hot-dipped / galvanized with minimum 220 GSM zinc coating complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of 25000 CFM CE certified / UL listed direct-driven VANE axial flow fan, conforming to EN 12201-3: 2015, at 35 mm static pressure having fan motor suitable for 3-Ph, 415 ± 10% V, 50 Hz power supply and minimum IE3 efficiency, Class ‘H’ insulation and Class ‘H’ smoke spill @ 250 °C for 2 hrs., mounting bracket and flexible connection for installation, total fan efficiency ≥ 70%, noise level ≤ 78 dBA @ 3 m distance for fans when measured in hemispherical reverberant room conditions, sound attenuators of appropriate length and hot-dipped / galvanized with minimum 220 GSM zinc coating complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of 7500 CFM CE certified / UL listed direct-driven VANE axial flow fan, conforming to EN 12201-3: 2015, at 35 mm static pressure having fan motor suitable for 3-Ph, 415 ± 10% V, 50 Hz power supply and minimum IE3 efficiency, Class ‘H’ insulation and Class ‘H’ smoke spill @ 250 °C for 2 hrs., mounting bracket and flexible connection for installation, total fan efficiency ≥ 70%, noise level ≤ 78 dBA @ 3 m distance for fans when measured in hemispherical reverberant room conditions, sound attenuators of appropriate length and hot-dipped / galvanized with minimum 220 GSM zinc coating complete all as specified and directed by the engineer-in-charge.
M & L for 1.1 kV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. (a) 3 core 4 mm2 , 2XWY
(b) 3 core 10 mm2 , 2XWY
S & F of 100 mm X 50 mm X 1.6 mm perforated hot dipped galvanized iron cable tray having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittigs viz. joints, bends, tees, etc. in convenient sections of length complete all as specified and directed by the engineer-in-charge.
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type BASEMENT VENTILATION DB (BVDB) (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge. . The VTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 200 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker(a) 100 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 01 Nos. [ii] Instrumentation & Measurement [ii] Instrumentation & Measurement (b) 100/5A Cl. 1.0 C.T. with 10 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [iii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set [C] OUTGOING
[i] Circuit Breaker (a) 63 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 3P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 03 Nos. [ii] Motor Starter / Drive (a) Variable Frequency Drive (VFD) of 15 kW rating with IP 55 enclosures and mains disconnect switch and comprising of the following complete with accessories of ABB, Danfoss, L&T E&A or Schneider make- 03 Nos. (1) built-in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the variable frequency drive (VFD). (2) built-in EMC filters (electro magnetic compatibility filters) for restriction of conducted emissions to comply with IEC61800: 3 (unrestricted distribution): 2004 category C 1 (50 meter) (3) three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of pumps. (4) integral graphical keypad. [iii] Instrumentation & Measurement (a) 100/5A Cl 1.0 CT having 10VA burden- 03 Nos. (b) 0-100A ammeter- 05 Nos. (b) 0-100A ammeter- 05 Nos. [iv] Indication & Annunciation [iv] Indication & Annunciation NOTES:- [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 3b. [ii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iii] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD.
STREET/GARDEN LIGHTING :- S & F of pole mounted LED luminaire for road lighting / area lighting having LED light source engine, integral fixed output driver, luminaire light beam spread 152° X 155°, upward light output ratio 0.03, luminous flux ≥ 5000 lm, luminous flux tolerance ±7%, luminous efficacy ≥ 115 lm/W, power consumption ≤ 45 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 4000K, CCT tolerance ±2%, colour rendering index (CRI) ≥ 70, SDCM < 5, power factor (fraction) > 0.95, control gear failure rate at median useful life 100000 h = 10% & lumen maintenance at median useful life 100000 h = L97 @ Tq = 25 °C, surge protection level until 6 kV differential mode and 8 kV common mode with aluminum die cast housing, glass optical cover / lens, IP66 & IK08 protection, and suitable for 220- 240 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class II safety, along with 1.0 m long cable with plug, compatible 2-pole and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: BGP300 LED50 757 PSU PC IN S1 or equivalent model of Lighting Technologies or Trilux
S & F of CE certified pole mounting bracket, black in colour and having overall width 700 mm, overall height 470 mm, bracket tilt angle 0°, bracket to luminaire diameter 1", mounting device diameter 90 mm, bracket length 700 mm and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Philips JGP700 MBP 700 BK G1 or equivalent model of Valmont, Surya or Bajaj
S & F of streetlight pole with flange, black in colour and having pole height of 5.5 m, mounting device diameter 90 mm, pole top diameter 90 mm, 2 X M8 holes distance 430 mm and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Philips YHM700 PL-FLG 5500 90 BK PD-T 2xM8-430 or equivalent model of Valmont, Surya or Bajaj
S & F of LED bollard, 0.8 m in height, to deliver landscape lighting having LED lighting engine source, integral fixed output driver, 120° luminaire light beam spread, luminous flux ≥ 400 lm, power consumption ≤ 8 W, initial corrected colour temperature (CCT) 4000K, colour rendering index (CRI) ≥ 80, median useful life L70B50 @ Ta = 45 °C ≥ 25000 hrs with extruded aluminum housing, polycarbonate diffused board optical cover, IP65 & IK10 protection, and suitable for on ground surface mounting, 220- 240 V input voltage, 50 Hz line frequency, ambient temperature range -20 to 40 °C, class I safety, CCCE, CE and RoHS compliance along with push in connector in 3 poles & 1 X M16 cable gland accepting 3C X 1 mm2 connection and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Philips BCP400 LED04 U CW PSU GR S1 or equivalent model ofor equivalent model of Lighting Technologies or Trilux
Supply, installation, testing and commissioning of intelligent street light control (ATSC) suitable for 6 kW maximum load, wall/pole mounted, having built-in networking support, built-in astronomical timer, 32 A TP contactor, 40 A TPN MCB housed in 3.15 mm thick powder CRCA sheet housing complete as all specified and directed by engineer- in- charge. (for street light and bollard light)
S&F LED Pathway not less than 35W, Pressure die cast aluminium housing with designed optics provide uniform light distribution to redefine outdoor and enhance architectural design, including fixing arrangements etc complete all as specified and directed. Make : Philips BGP300 LED40 757 PSU PC IN S1/ Wirpo cat No. LP06-351-XXX-57-XX
Supply and fix anthracite COB Garden spike light 12 watt single phase 230 Volts Make-Philips Model No-31386, Product Code-919215850754
DG SET:- Supply, installation, testing and commissioning of silent LT diesel generator set of 1250 kVA rating along with AMF cum synchronizing panel with associated switchgear, control panel and exhaust piping as per latest CPCB norms (with amendments up to date at the time of execution), with necessary foundation, HSD oil storage & distribution system etc. with all necessary statutory approvals complete all as specified and directed by the engineer-in-charge. The diesel generator set shall conform to the following technical specifications. [A] Engine (i) Rating: 1250 kVA (ii) Emissions / Fuel Strategy: Low Fuel Consumption (iii) Duty: Prime Power (iv) Overload: 10% for 1 hr in every 12 hrs (v) Site Output: 1250 kVA (vi) No. of Silencer: 2 (vii) Governor Type: Electronic-A1 (viii) Cooling System: Radiator Cooled (ix) Silencer Type: Residential [B] Starting System (i) Type of Starting System: Battery Starting System (Ele.) (ii) Type of Battery: SMF VRLA type (iii) Battery Voltage: 12 V (iv) Number of Battery: 02 Nos. (v) Ah Capacity: 160 Ah [C] Fuel Oil System (i) Fuel consumption @ 75% load: ≤ 195 litre/hr (ii) Fuel consumption @ 100% load: ≤ 255 litre/hr (iii) Fuel tank capacity: ≥ 990 litre (outside) (iv) Fuel tank thickness & MOC: 3 mm thick mild steel [D] Lube Oil System (i) Lube oil sump capacity: ≥ 175 litre (ii) Lube oil consumption: ≤ 0.30 litre/hr (iii) Lube oil Grade: CHW 15W 40 [E] Alternator Details (i) Rating: 1250 kVA (ii) Voltage: 440 V (iii) Power Factor (PF): 0.8 lag (iv) Connection: 3-Phase, 4-Wire (v) Degree of Protection: IP 23 (vi) Insulation: Class H (vii) Temperature Rise: Limited to Class H (viii) Excitation System: Separately Excited (ix) Frequency: 50 Hz (x) Voltage Variation: ±5% (xi) Voltage Regulation: ±0.5% [F] DG Set Details (i) Mounting Type: AVM Pad [G] Integrated DG Set Controller (1) Control: (i) Run/ Off / Auto Switch (ii) Emergency Stop (iii) Manual Run Stop Control Switch (iv) Idle / Run Mode Control (2) Metering (Engine): (i) Starting Battery Voltage (ii) Lube Oil Temperature & Pressure (iii) Engine coolant Temperature (iv) Coolant Pressure (v) Engine rpm (vi) Operating Hours (vii) Number of Starts (3) Electrical: (i) Current (ii) Voltage (iii) Frequency (iv) kW (v) kWh
(vii) Weak Battery Warning (viii) Over Crank Shutdwn (ix) Fail to Crank Shutdown (x) Magnetic Pickup Failure Shutdown (4) Alternator: (i) Overcurrent (ii) High Voltage (iii) Low Voltage (iv) Under / Over Frequency (v) Reverse Power (kVA & kVAr) (vi) Phase Sequence (vi) Phase Sequence (5) Misc: (i) Digital AVR (ii) Amp Sentry Protection (iii) Sensor Failure Indication (iv) Programmable Idle Speed Control (v) Digital Synchronizing Function (vi) Sync Check (vii) Synchronoscope (viii) Auto Load Sharing (ix) Compatibility to Remote Monitoring (x) Smart Starting [H] Exhaust System (i) Exhaust piping of size 12" dia. (300 mm NB), 4.85 mm thick plate and 16" dia. & (400 mm NB) 5 mm thick, MS Class B pipes conforming to IS 3589: 2001 with 75 mm thick glasswool / mineral wool insulation with wire chicken mesh over insulation and 24 gauge aluminium sheet cladding over the exhaust pipes from silencer to atmosphere including welding joint(s), bend(s), clamp(s), dash fasteners, flanges, nuts, bolts, etc. complete as required and as per specification (ii) Aluminium cladding for residential silencer with mineral wool 50 mm thick, density 64 kg/m3, wire mesh and 24 gauge aluminum cladding (iii) MS self-support structure for exhaust piping (iv) SS flexible bellows, 16" dia. (400 mm NB) complete with counter flanges, heat resistant gaskets, nuts, bolts and washers, etc. complete as required (v) Lightning arrester with GI strip upto earth pit [I] Power Cabling (i) 6# of 1.1 kv grade 4 core, 300 mm2 A2XWY cable, specified separately. [J] CONTROL CABLES & TERMINATION KITS (i) 24 core, 2.5 mm2, Cu conductor, XLPE insulated armoured control cable as required along with necessary termination kits (ii) 4 core, 2.5 mm2, Cu conductor, XLPE insulated armoured control cable as required along with necessary termination kits
Supplying, installation, testing and commissioning of online double conversion fully microprocessor based, indoor type, compact UPS system of 10 kVA rating with IGBT based PWM technology to achieve THD < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% V & frequency 50 ± 0.5% Hz , inbuilt isolation transformer, necessary VRLA batteries of suitable size having 30 minutes back up time, mounting rack including and suitable size connecting cable (for UPS to battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP compatibility for operation and monitoring etc. complete with all necessary components and accessories as specified and directed by the engineer-in-charge. The UPS shall conform to the following technical parameters: [A] UPS Technology True Online Double Conversion as per VFI-SS-111 [B] Environmental (i) Operating Temperature: 0 to 40 °C (ii) Maximum Temperature: 40 °C (iii) Storage Temperature: -25 to 70 °C (iv) Relative Humidity: 95% Non-condensing (v) Altitude: up to 1000 m from MSL [C] Input (i) Standard Voltage: 380 / 400 / 415 V, 3-Ph (ii) Voltage Tolerance: +15% to -20% @ 400 V (iii) Frequncy: 50 Hz (iv) Frequency Tolerance: ±10% @ 50 Hz without UPS tripping (v) Rectifier Type (Inverter Technology): IGBT three level PWM design (vi) Power Factor at Rated Load: ≥ 0.99 (vii) Input THDi at Rated Load: ≤4% at 100% Load (viii) Input Phase Auto Correction: to be provided in built [D] Output (i) Output Rating: 10 kW (ii) Voltage: 3-Phase, 415 V (iii) Voltage Range: 320-480 V (line to line) @ full Load & 260-480 V @ < 50% Load (iv) Frequency: 50 Hz (v) Voltage Stability- Steady State: ±0.5 to 1% typical (vi) Phase Angle Accuracy: ±1° for balanced load, ±2° for unbalanced load (vii) Non-linear Load Permissible: Yes (viii) Voltage Stability- transient state with 100% Load change: ±5% (ix) Frequency Stability: 50 Hz ±0.5% (x) Crest Factor: 3:1 (minimum) (xi) Output Voltage Distortion: 1. with 100% Linear Load < 2% 2. with 100% non-Linear Load < 4% (xii) Power Factor: Unity
(xiii) Overall Efficiency at Rated Load (without transformer losses: ≥ 92% (ixv) Overload: 110% for 10 minutes & 150% for 30 seconds [E] Protection (i) Input under voltage (ii) Input over voltage (iii) Output under voltage (iv) Output over voltage (v) Loss of input power (vi) Output overload (vii) Galvanic Isolation Transformer at input side (viii) Protection against surges (ix) Battery circuit breaker (BCB) for automatic isolation of battery line in case of battery under voltage and over current conditions. (x) Fully rated static switch in inverter output (xi) RS 232 / RS 485 Serial port computer compatibility. (xii) Network monitoring (SNMP) (xiii) External dry contacts (ixv) Microprocessor based self diagnostics and monitoring. (xv) Inbuilt Isolator to be provided for isolating input & output, static bypass & maintenance bypass (xvi) For 1/2/3 phase UPS, the output voltage is genuinely generated directly from the inverter itself. (xvii) Fuse line protection for input. (xviii) Protection against over temperature.[F] Certification / Compliance (i) IEC 62040-1 (ii) IEC 62040-2 (iii) IEC 62040-3 (iv) IS 16242-1 [G] Batteries (i) Type: Sealed Maintenance free, 12 V (ii) Power Backup 30 minutes (iii) Minimum Vah to be Complied: 10080 VAh (iv) Battery Life: Minimum 5 yrs of design life NOTES:- [i] The bidder shall furnish the battery sizing calculations and GA drawing to the engineer-in-charge for approval of the MEP Consultant and thereafter the A.O. / representative.
Supplying, installation, testing and commissioning of online double conversion fully microprocessor based, indoor type, compact UPS system of 200 kVA rating with IGBT based PWM technology to achieve THD < 3% and input power factor of greater than 0.95 at 50% loading, suitable for three phase AC input voltage 380 V to 440 V, 50 Hz +3% / - 3 % and three phase AC output voltage 415 ± 1% volts & frequency 50 ± 0.5 Hz , inbuilt isolation transformer, necessary VRLA batteries of suitable size having 30 minutes back up time, mounting rack including and suitable size connecting cable (for UPS to Battery and battery to battery), static and maintenance bypass switch, SNMP card for RS232/ ethernet IP compatibility for operation and monitoring etc. complete with all necessary components and accessories as specified and directed by the engineer-in-charge. The UPS shall conform to the following technical parameters: [A] UPS Technology True Online Double Conversion as per VFI-SS-111 [B] Environmental (i) Operating Temperature: 0 to 40 °C (ii) Maximum Temperature: 40 °C (iii) Storage Temperature: -25 to 70 °C (iv) Relative Humidity: 95% Non-condensing (v) Altitude: up to 1000 m from MSL [C] Input (i) Standard Voltage: 380 / 400 / 415 V, 3-Ph (ii) Voltage Tolerance: +15% to -20% @ 400 V (iii) Frequncy: 50 Hz (iv) Frequency Tolerance: ±10% @ 50 Hz without UPS tripping (v) Rectifier Type (Inverter Technology): IGBT three level PWM design (vi) Power Factor at Rated Load: ≥ 0.99 (vii) Input THDi at Rated Load: ≤4% at 100% Load (viii) Input Phase Auto Correction: to be provided in built [D] Output (i) Output Rating: 200 kW (ii) Voltage: 3-Phase, 415 V (iii) Voltage Range: 320-460 V (line to line) @ full Load (iv) Frequency: 50 Hz (v) Voltage Stability- Steady State: ±0.5 to 1% typical (vi) Phase Angle Accuracy: ±1° (vii) Non-linear Load Permissible: Yes (viii) Voltage Stability- transient state with 100% Load change: ±5% (ix) Frequency Stability: 50 Hz ±0.5% (x) Crest Factor: 3:1 (minimum) (xi) Output Voltage Distortion: 1. with 100% Linear Load < 1% 2. with 100% non-Linear Load < 5% (xii) Power Factor: Unity (xiii) Overall Efficiency at Rated Load (without transformer losses: ≥ 95% (ixv) Overload: 110% for 10 minutes & 150% for 30 seconds
[E] Protection (i) Input under voltage (ii) Input over voltage (iii) Output under voltage (iv) Output over voltage (v) Loss of input power (vi) Output overload (vii) Galvanic Isolation Transformer at input side (viii) Protection against surges (ix) Battery circuit breaker (BCB) for automatic isolation of battery line in case of battery under voltage and over current conditions. (x) Fully rated static switch in inverter output (xi) RS 232 / RS 485 Serial port computer compatibility. (xii) Network monitoring (SNMP) (xiii) External dry contacts (ixv) Microprocessor based self diagnostics and monitoring. (xv) Inbuilt Isolator to be provided for isolating input & output, static bypass & maintenance bypass (xvi) For 1/2/3 phase UPS, the output voltage is genuinely generated directly from the inverter itself. (xvii) Fuse line protection for input. (xviii) Protection against over temperature. [F] Certification / Compliance (i) IEC 62040-1 (ii) IEC 62040-2 (iii) IEC 62040-3 (iv) IS 16242-1 [G] Batteries (i) Type: Sealed Maintenance free, 12 V (ii) Power Backup 30 minutes (iii) Minimum Vah to be Complied: 187200 VAh (iv) Battery Life: Minimum 5 yrs of design life NOTES: [i] The bidder shall furnish the battery sizing calculations and GA drawing to the engineer-in-charge for approval of the MEP Consultant and thereafter the A.O. / representative.
M & L for 6 core, 2.5 mm² low smoke zero halogen (LS0H) fire survival control cable with circuit integrity, conforming to BS 7846 and rated for 600 V, having plain annealed stranded copper conductor with fire-resistant mica tapes covered by an extruded layer of cross-linked polyethylene, extruded layer of thermoplastic low smoke zero halogen (LS0H) compound, single layer of galvanized steel wires and thermoplastic LS0H compound sheath, suitable for operating temperature range -40 ˚C to +90 ˚C and minimum bending radius being 12 times the overall cable diameter, including laying, clamping, termination and ferruling complete as specified and directed by the engineer-in-charge.
M & L for normal type 50 mm NB double-wall corrugated poly PE pipe with co-extruded bands on the outside and black interior having crush resistance as per IEC 23-46;V1 with 5% deformation of internal diameter, stabilised against UV rays and tested as per ISO 1133 along with accessories for protection of LV and MV electric cables complete as specified and directed by the engineer-in-charge.
AUDIO VISUAL SYSTEM:- Supply and Installation of Front Center Loudspeakers (Make : Bose Model : ArenaMatch Utility AMU208) Loudspeaker with drivers: 2 X 8" LF, 1 X 1"HF; frequency response of 80Hz to 16kHz, Nominal coverage pattern of 90 degree X 60 degree with rotatable high frequency horn, Power handling of 400W @ 8 Ohm, Sensitivity of 94 dB SPL, Max SPL of 120 dB SPL, Included U-bracket plus four M8 inserts - for mounting flexibility with 18-gauge perforated steel, powder-coated finish, black finished with the two-part spray polyurethane coating, black. Make: Bose Professional/D&B Audiotechnik/L-Acoustics
Supply and Installation Of Front Left & Right Loudspeakers (Make : Bose Model : ArenaMatch Utility AMU208) Loudspeaker with drivers: 1 X 8" LF, 1 X 1"HF; frequency response of 80Hz to 16kHz, Nominal coverage pattern of 90 degree X 90 degree with rotatable high frequency horn, Power handling of 200W @ 8 Ohm, Sensitivity of 94 dB SPL, Max SPL of 120 dB SPL, Included U-bracket plus four M8 inserts - for mounting flexibility with 18-gauge perforated steel, powder-coated finish, black finished with the two-part spray polyurethane coating, black. Make: Bose Professional/D&B Audiotechnik/L-Acoustics
Supply and Installation Of 2 Left Surround & 2 Right Surround Loudspeakers (Make : Bose Model : ArenaMatch Utility AMU105) Loudspeaker Frequency response: 100 Hz to 16kHz; Nominal Coverage: 100 H x 100 V; Power handling: 100 Watt @ 8 ohms; Sensitivity: 90 Db SPL; Max SPL: 110 Db SPL; 18-gauge (1.2 mm) perforated steel, powder-coated finish. Black. Make: Bose Professional/D&B Audiotechnik/L-Acoustics
Supply and Installation Of 2 Left Atmos & 2 Right Atmos Loudspeakers (Make : Bose Model : Freespace FS4CE) LoudspeakerFull-range 4.5-inch transducer, low-frequency range down to 70 Hz, 8-ohm operation, Front baffle-mounted tap settings and front-baffle audio connections, Handles the weather, designed for outdoor wet installation, Maintain consistent tonal quality. Make: Bose Professional/D&B Audiotechnik/L-Acoustics
Supply and Installation Of 2 Subwoofers (Make : BOSE Model : MB 210WR) Frequency range of 35Hz-220Hz ; Omni-directional ; Long term power handling of 500 Watts @ 8 Ohms ; Nominal impedance of 4 Ohms and High-excursion drivers, 123 dB maximum continuous SPL, 129 dB peak SPL, powder-coatedfinish. Black. Make: Bose Professional/D&B Audiotechnik/L-Acoustics
Supply and Installation Of AV Surround Receiver Amplifier/Processor (Make : Marantz Model : SR7015) 11.2 Channel Max Processing Full 4K Ultra HD A/V Pre Tuner with Bluetooth and Wi-Fi.Latest HDMI 2.0a Connectivity; HDCP 2.2 Compatible; ISF-Certified & support HEOS Make: Marantz/Emotiva/Arcam
Supply and Installation Of Wireless Hanheld Microphone System (Make : Sennheiser Model : XSW 1-835-A) THD, total harmonic distortion ≤ 0.9%; Pick-up pattern cardioid ; Signal-to-noise ratio ≥ 103 dBA ; RF output power 10 mW ;Switching bandwidth up to 24 MHz ;Operating time approx. 10 hrs ; Modulation wideband FM ; Output voltage 1/4“ (6.3 mm) jack socket (unbalanced): +6 dBu, XLR socket (balanced): +12 dBu ;Housing rugged ABS housing ; Dynamic range dynamic ; Frequency 8 frequency banks, each with up to 10 factory-preset channels ; Frequency range A: 548-572 MHz, GB: 606-630 MHz ; B: 614-638 MHz C: 766-790 MHz ;D: 794-806 MHz ; E: 821-832 MHz, 863-865 MHz ; K: 925-937.5 MHz ; Sensitivity < 3 μV at 52 dB(A)rms S/N. Make:Sennheiser/Shure/Beyerdynamics
Supply and Installation Of Wireless Lapel Microphone System (Make : Sennheiser Model : XSW 1-ME2-A) THD, total harmonic distortion ≤ 0.9% ; Pick-up pattern omni-directional ; Signal-to-noise ratio ≥ 103 dBA ; RF output power 10 mW ; Switching bandwidth up to 24 MHz ; Operating time approx. 10 hrs ; Modulation wideband FM ; Output voltage '1/4“ (6.3 mm) jack socket (unbalanced): +6 dBu, XLR socket (balanced): +12 dBu ; Housing rugged ABS housing ; Diversity reception antenna switching diversity via internal antennas ; Frequency 8 frequency banks, each with up to 10 factory-preset channels ; Frequency range A: 548-572 MHz, GB: 606-630 MHz ; B: 614-638 MHz, C: 766-790 MHz ; D: 794-806 MHz ; E: 821-832 MHz, 863-865 MHz ; K: 925-937.5 MHz ; Sensitivity < 3 μV at 52 dB(A)rms S/N ; SPL for peak deviation 130 dB ; Squelch adjustable from 3 dBμV to 28 dBμv ; Synchronization 2.4 GHz, Low Power OQPSK (only active during synchronization) ; Input sensitivity 1.5 mV / Pa ; Audio adjustment range 45 dB, adjustable in 5-dB steps ; Line / Mic level 20 dB, switchable. Make: Sennheiser/Shure/Beyerdynamics
Supply and Installation Of Wired GOOSENECK MIC CARDIOID with TABLE STAND (Make : Sennheiser Model : MEG 14-40 B+MAT 133-S B) Impedance < 100 Ω ; Dimensions length: 450 mm (17,72") ; Frequency response (Microphone) 50 Hz - 20 kHz ; Transducer principle (Microphone) pre polarised condenser microphone; Weight 147 g (4,72 oz) Pick-up pattern cardioid; Operating temperature 0 ... +40 °C ; Equivalent noise level 26 dB (A) ; Equivalent noise level weighted as per CCIR 468-3 37 dB ; Maximum sound pressure level (passiv) 130 dB SPL Power supply P12 - P48 V ; Current consumption 3 mA Make: Sennheiser/Shure/Beyerdynamics
Supply and Installation Of 8 Channel Mixer (Make : Yamaha Model : MG10) Mixer:3.25" H x 12.25" W x 8.4" D (4.1 lbs); Inputs: 8 combo XLR - ¼"; 2 Aux; USB port; Outputs: 2 balanced ¼" TRS, 2 XLR, 4 Aux sends, USB port, Headphone. Make: Yamaha/Behringer/RCF
Supply and Installation Of Digital Power Amplifier (Make : BOSE Model : Power Space P21000A) Maximum Rated Power:2 x 1000 W (THD+N < 0.04%, 1 kHz, 4-8 Ω , 70/100V) Output Channels: 2 speaker, 8 digital (Amplink), Input Channels, 2 balanced (analog), 8 digital (Amplink) Make: Bose Professional/D&B Audiotechnik/L-Acoustics
Supply and Installation Of 4K Digital Media Player (Make : Dune HD Model : Magic Pro 4K) Multi media player with Android app support, USB HDD, Network Media Player Capabilities. Make: Cubetek/WD/Dune HD
Supply and Installation of Cinema Projector (Make : Epson Model : EH-TW-9400) Lamp Technology: LCD Lamp Replcament Cycle Hours: Upto 5000 Hours or Higher.Native Rsolution: 4K, FUll HD, WUXGA 1920x1200 Pixcels or Higher.Aspect Ratio: 16:9 or HigherBrightness: 3,000 Lumens or Higher.Contrast Ratio: 10,000:1 or Higher.Zoom: Powered Optical zoom of throw ratio 1.7-2.4:1 or higher.Center to Corner Uniformity: 90% or Higher.Refresh Rate: 24-60HzTerminations: DVI-D, HDMI 19-pin × 1 (Deep Color, compatible with HDCP).BNC × 5 (RGB/YPBPR/YCBCR/YC/video × 1)D-Sub HD 15-pin (female) × 1 (RGB/YPBPR/YCBCR × 1)D-sub 9-pin (female) × 1 for external control (RS-232C compliant) or Higher. Make:(Panasonic, Epson, Barco)
Supply & Installation of High Gain Fixed Frame Projector Screen16:9 Format 170" diagonal fixed frame perforated screen with Gain 1:1 support for 3D & 4K video. Make: Da-lite/Elite/Eurros
Supply & Installation of Control Processor for Complete Lighting & Automation (Make : Crestron Model : CP4) Crestron 3 Series Control System with 3-RS232, 8 IR, 8 Relay, 8 I/O, Ethernet, Cresnet for complete lighting, HVAC, Audio & Video Control from user interface. Make: Crestron/Lutron/Extron
Supply & Installation of Lighting Control Dimmer Module (Make : Crestron Model : DIN-1DIM4) DIN Rail Dimmer, 1 feed, 4 channels for 230 V Dimming Make: Crestron/Lutron/Extron
Supply & Installation Of Control Keypad for Automation (Make : Crestron Model : C2NI-CB-B-T) Cameo® Keypad - International Version, Black Textured with 2/3/4/5/6/7/8/10 button combinations Make: Crestron/Lutron/Extron
Supply & Installation Of IR Control Probes (Make : Crestron Model : IRP2) IR Emitter Probe w/Terminal Block Connector to control HVACs & IR Controlled AV Sources Make: Crestron/Lutron/Extron
Supply & Installation Of 16 Port LAN Network POE Switch (Make : Netgear Model : Business Switch) 16 Port 100/1000Mbps LAN Network Switch With uPOE support. Make: Cisco/Netgear/HP Auruba
Supply & Installation Of Wifi Access Point (Make : Ubiquiti Model : UAP-AC6) 2.4/5Ghz Wifi 6 Access Point With POE Support Make: Cisco/Netgear/Ubiquiti
Supply & Installation Of Wifi Router (Make : Netgear Model : Netgear) 2.4/5Ghz 600Mbps Wifi Router Make: Cisco/Netgear/Ubiquiti
Supply & Installation Of 32 RU System Housing Rack (Make : Legrand Model : 32RU) 32 RU 600x600 Network Equipment Housing Rack with 4 Nos of Fans, 2 Nos of 15Amps 10 Plugs Strip, 2 Nos Of Rack Trays, 10 Nos of Cable Managers, 2 Nos of Rack Grounding Kit, 10 Nos of Rack Blank Plates. Make: Elixer/Legrand/Middle Atlantic
Supply & Installation Of User Interface Application (Make : Crestron Model : Crestron App) User interface for controling complete automation system for lights, HVACs, Audio & Video from iPad Make: Crestron/Lutron/Extron
Supply & Installation Of iPad - User Interface (Make : Apple Model : iPad) Apple iPad Tablet (9.7 inch, 32GB, Wi-Fi), Space Grey
Supply and Installation Of Required Device Installation HDMI Cables, Speaker cable, Network Cables, speaker & Projector mounting kits, connectors and all required accessories. Make: Krystal/Belden/QED
Supply & Installation Of Multimedia Conference Room Projector (Make: Panasonic Model: PT-LB386D) Specifications: •3800 Lumens • , Dual HDMI - WXGA native resolution, Higher contrast Ratio - 20,000 : 1
Supply & Installation Of Projector Screen (Make: Imported Model: Imported) Specifications: •120 inch Manual retractable white HD projector screen
Supply and Installation Of Wireless Hand held Microphone System (Make : Sennheiser Model : XSW 1-835-A) THD, total harmonic distortion ≤ 0.9%; Pick-up pattern cardioid ; Signal-to-noise ratio ≥ 103 dBA ; RF output power 10 mW ;Switching bandwidth up to 24 MHz ;Operating time approx. 10 hrs ; Modulation wideband FM ; Output voltage 1/4“ (6.3 mm) jack socket (unbalanced): +6 dBu, XLR socket (balanced): +12 dBu ;Housing rugged ABS housing ; Dynamic range dynamic ; Frequency 8 frequency banks, each with up to 10 factory-preset channels ; Frequency range A: 548-572 MHz, GB: 606-630 MHz ; B: 614-638 MHz C: 766-790 MHz ;D: 794-806 MHz ; E: 821-832 MHz, 863-865 MHz ; K: 925-937.5 MHz ; Sensitivity < 3 μV at 52 dB(A)rms S/N. Make:Sennheiser/Shure/Beyerdynamics
Supply and Installation Of Wireless Lapel Microphone System (Make : Sennheiser Model : XSW 1-ME2-A) THD, total harmonic distortion ≤ 0.9% ; Pick-up pattern omnidirectional ; Signal-to-noise ratio ≥ 103 dBA ; RF output power 10 mW ; Switching bandwidth up to 24 MHz ; Operating time approx. 10 hrs ; Modulation wideband FM ; Output voltage '1/4“ (6.3 mm) jack socket (unbalanced): +6 dBu, XLR socket (balanced): +12 dBu ; Housing rugged ABS housing ; Diversity reception antenna switching diversity via internal antennas ; Frequency 8 frequency banks, each with up to 10 factory-preset channels ; Frequency range A: 548-572 MHz, GB: 606-630 MHz ; B: 614- 638 MHz, C: 766-790 MHz ; D: 794-806 MHz ; E: 821-832 MHz, 863-865 MHz ; K: 925-937.5 MHz ; Sensitivity < 3 μV at 52 dB(A)rms S/N ; SPL for peak deviation 130 dB ; Squelch adjustable from 3 dBμV to 28 dBμv ; Synchronization 2.4 GHz, Low Power OQPSK (only active during synchronization) ; Input sensitivity 1.5 mV / Pa ; Audio adjustment range 45 dB, adjustable in 5-dB steps ; Line / Mic level 20 dB, switchable. Make: Sennheiser/Shure/Beyerdynamics
Supply and Installation Of Wired GOOSENECK MIC CARDIOID with TABLE STAND (Make : Sennheiser Model : MEG 14-40 B+MAT 133-S B) Impedance < 100 Ω ; Dimensions length: 450 mm (17,72") ; Frequency response (Microphone) 50 Hz - 20 kHz ; Transducer principle (Microphone) pre polarised condenser microphone; Weight 147 g (4,72 oz) Pick-up pattern cardioid; Operating temperature 0 ... +40 °C ; Equivalent noise level 26 dB (A) ; Equivalent noise level weighted as per CCIR 468-3 37 dB ; Maximum sound pressure level (passiv) 130 dB SPL Power supply P12 - P48 V ; Current consumption 3 mA Make: Sennheiser/Shure/Beyerdynamics
Supply and Installation Of Mixer Amplifier (Make : Bose Model : IZA 190HZ) 1x90W@70V/100V Mixer digital amplifier with Analog RCA Audio Inputs Make: Bose/Behringer/RCF
Supply and Installation Of Wall Mount Speakers (Make : Bose Model : FS4SE) 40W Wall mount speakers With 70V/100V Tap transformer settings Make: Bose/Biamp/Yamaha
Supply and Installation Of Required cables, Connectors & Accessories (Make : Reputed) All required speaker cables, Microphone cables, HDMI cables, Connectors and accessories for all conference room audio visual devices.
EXTERNAL ELECTRIFICATION Supply, installation, testing and commissioning of rated sandwich type (3L+N+PE) busbar trunking system complete with two runs of 50 mm X 6 mm aluminium earthing strip and accessories all as specified and directed by engineer-in-charge. The BTS shall conform to the following technical specifications: [A] GENERAL [i] The busbar trunking system (BTS), both feeder and plug-in, shall be of sandwich construction. All components and fittings (straight length, elbow, tee, flanged end, cable tap-off box and circuit breaker etc.) shall conform to IEC 61439-6:2012 or UL 857 and shall be procured from the OEM of BTS. The BTS shall have IP 65 protection with canopy for outdoor application and IP 54 protection for indoor application in accordance with IEC 60529: 1989. [ii] The rated operation voltage of BTS shall not be less than 1 kV. The neutral conductor shall have the same cross-sectional area as the phase conductor and the earth busbar shall be provided on both sides of the housing.
[B] CERTIFICATE [i] The busbar, of full range and each rating, shall pass full type tests specified in IEC 61439-6-2012. The certificate shall be issued by an international independent testing authority, e.g. ASTA. KEMA. UL, ERDA, CPRI etc. [ii] A product safety mark, e.g. KEMA-KEUR, ASTA DIAMOND, UL and ERDA, CE, etc. shall be on the product offering a visual assurance of full product safety testing, factory inspection and ongoing surveillance under independent authority. [iii] The BTS shall be certified for siesmic tests conforming to IEEE 693-2018 for seismic zone V. [C] SHORT-CIRCUIT RATINGS & TESTS [i] The entire BTS (busduct and plug-in box assembly) shall be capable of withstanding the short-circuit of electrical installation without undergoing any electrical, mechanical or thermal stress under fault condition at a service voltage of 1 kV at 50 Hz frequency. The minimum rated insulation voltage shall be 1 kV.
[ii] The minimum certified short-circuit withstand capacity for 800 A rating shall be 50 kA for 1 sec. [iii] The minimum certified short-circuit withstand capacity for 1000 A rating shall be 50 kA for 1 sec. [iv] The minimum certified short-circuit withstand capacity for 1250 A rating shall be 65 kA for 1 sec. [v] The minimum certified short-circuit withstand capacity for 1600 A rating shall be 80 kA for 1 sec. [vi] The minimum certified short-circuit withstand capacity for 2000 A rating shall be 80 kA for 1 sec. [vii] The minimum certified short-circuit withstand capacity for 2500 A rating shall be 80 kA for 1 sec. [viii] The minimum certified short-circuit withstand capacity for 3200 A rating shall be 100 kA for 1 sec. [ix] The minimum certified short-circuit withstand capacity for 4000 A rating shall be 100 kA for 1 sec. [x] The minimum certified short-circuit withstand capacity for 5000 A rating shall be 100 kA for 1 sec. [xi] The minimum certified short-circuit withstand capacity for 6300 A rating shall be 100 kA for 1 sec. D] HOUSING [i] The busbar trunking housing shall be constructed of 1.6 mm thick electro-galvanised steel and shall be provided with a suitable protective finish of epoxy paint. [ii] The busbar trunking housing shall be totally enclosed non-ventilated for protection against mechanical damage and dust accumulation and it shall be tested for its characteristics offering resistance against corrosion. It shall also pass at least 1000 salt spray test to ensure its anti-corrosion ability. [iii] The totally enclosed housing shall be manufactured by the BTS OEM and modifications of busbar trunking to make it totally enclosed by housing other than the busbar trunking OEM shall be unacceptable without written consent of the OEM. [E] BUBARS [i] The busbars shall be of aluminium with tin / silver plating at joint and conductivity of the joint shall be > 60% IACS [ii] There shall be no bolts passing through the busbars of the BBT. [iii] Each busbar shall be insulated with Class-F (155 ⁰C) multilayer PET insulation. Epoxy and Mica insulation shall be unacceptable. [iv] The temperature rise at any point of busbar trunking enclosure shall not exceed 55 ⁰C above the ambient temperature of 40 ⁰C when operated at the rated current.
[F] JOINTS [i] The busbar trunking joint shall be of one-bolt type utilizing high strength steel bolt(s) and Belleville washers to maintain proper pressure over a large contact surface area. [ii] The bolt(s) shall be torque indicating and at earth potential.[iii] The nut(s) shall be of two-headed design to indicate proper torque has been applied and shall require only a standard long handle wrench to be properly activated. [iv] Access shall be required to only see one side of the busbar trunking to tighten joint bolts. [v] It shall be possible to remove any joint connection assembly to allow electrical isolation or physical removal of a busbar trunking length without disturbing adjacent busbar trunking lengths. [G] PLUG-IN OPENING [i] The connecting jaw of a plug-in unit shall plug directly onto the busbar and have full contact with busbar itself. Welded tab at plug-in busbar is unacceptable. [ii] All contact on joint and plug-in opening shall be of copper strip in order to avoid external force damage on busbar while plugging in or plugging out operation.[iii] On plug-in busbar trunking there shall be three dead front, hinged cover type plug-in opening on each side. [iv] All openings shall be usable simultaneously. Busbar trunking shall be installed in such a manner that plugs are side mounted to permit practical use of all plug-in openings. [v] It shall be possible to inspect the plug-in opening and busbars prior to the installation of plug-in units. [H] SUPPORT STRUCTURE [i] Support structure shall be provided as per OEM's recommendation. [ii] Indoor feeder and plug-in busbar trunking shall be approved for hanger spacing of up to 3 m for horizontally mounted run and 4.88 m for vertically mounted runs. Outdoor feeder busbar trunking shall be approved for spacing up to 1.5 m for horizontally or vertically mounted runs.
[I] VOLTAGE DROP [i] The voltage drop (sending end voltage minus receiving end voltage) specified shall be based on the busway operating at full rated current and stabilized operating temperature in [ii] The 3- Phase line to line voltage drop shall not exceed 3.4 V per 100 feet length at 40% power factor concentrated load which may exist during motor starting. [iii] The line to line voltage drop shall not exceed 4.1 V per 100 feet at the load power factor which produces the maximum voltage drop in the busway. [J] INSPECTION / SUPPORT OF INSTALLATION [i] The installation of busbar trunking system (BTS) shall be executed by skilled professionals with minimum experience of 4 yrs. having sufficient installation base and pre-commissioning experience. [ii] The entire installation shall be directly supervised by the OEM. [iii] The OEM shall also furnish a commissioning report underlining satisfactory installation after the commissioning of BBT system.
2500 A BTS (T/R to MLTP)
straight length
90° flat elbow
edgewise elbow/hanger
Flange end
Copper Flexible (Braided)
Adopter Box (Local Item)
Termination Links (Local Item)
2000 A BTS (AMF Panel to ELP)
straight length
90° flat elbow
edgewise elbow/hanger
Flange end
Copper Flexible (Braided)
Adopter Box (Local Item)
Termination Links (Local Item)
1600 A BTS (MLTP to AMF Panel)
straight length
90° flat elbow
edgewise elbow/hanger
Flange end
Copper Flexible (Braided)
Adopter Box (Local Item)
Termination Links (Local Item)
800 A BTS (ELP to HVAC Panel & FEP)
straight length
90° flat elbow
edgewise elbow/hanger
Flange end
Copper Flexible (Braided)
Adopter Box (Local Item)
Termination Links (Local Item)
M & L of structural steel for BBT support structure with painting as recommended by OEM. NOTES: [i] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative.
NOTES: [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 4b. [ii] ACBs shall have separately powered, individual fault trip indication LEDs (For overload, short circuit, earth fault and trip-unit failure) shall be available on the trip unit which shall function even in the absence of external power supply to the breaker.ACB shall be suitable for ZSI. Trip units shall have thermal memeory as standard. [iii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iv] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [v] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V. [vi] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vii] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [viii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative. [ix] The Contractor shall intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
C] OUTGOING [i] Circuit Breaker (a) 160 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos. (b) 100 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos. (c) 63 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 12 Nos. [ii] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 16 Set NOTES: [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 4b. [ii] ACBs shall have separately powered, individual fault trip indication LEDs (For overload, short circuit, earth fault and trip-unit failure) shall be available on the trip unit which shall function even in the absence of external power supply to the breaker.ACB shall be suitable for ZSI. Trip units shall have thermal memeory as standard. [iii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iv] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [v] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V.
[vi] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vii] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [viii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative. [ix] The Contractor shall intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type Lighting Load Panel (LDB) (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge. The LDB shall comprise of the following: [A] BUS BAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 125 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 125 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 01 Nos. [ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. (b) 150/5A Cl. 1.0 C.T. with 10 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [iii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set [C] OUTGOING [i] Circuit Breaker (a) 32 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 12 Nos. [ii] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 12 Set
NOTES: [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 3b. [ii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iii] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [iv] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V. [v] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vi] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [vii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative. [viii] The Contractor shall intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type Uninterrupted Power Supply Panel (UDB) (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge. The UDB shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 400 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having microprocessor based trip unit, adjustable overload setting, adjustable short-circuit setting, adjustable neutral protection, electrical interlocking, front indication LEDs, etc.- 01 Nos. [ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. (b) 400/5A Cl. 1.0 C.T. with 10 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [iii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set [C] OUTGOING [i] Circuit Breaker (a) 200 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos.
(b) 100 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos. (c) 32 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 12 Nos. [ii] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 16 Set NOTES: [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 3b. [ii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iii] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [iv] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V. [v] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vi] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [vii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative. [viii] The Contractor shall intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type ACDB (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge. The ACDB shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 125 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 125 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 01 Nos. [ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. (b) 150/5A Cl. 1.0 C.T. with 10 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [ii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set [C] OUTGOING [i] Circuit Breaker (a) 32 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 12 Nos. [ii] Indication & Annunciation (a) LED status indicators (ON, OFF, TRIP)- 12 Set
NOTES: [i] The busbars shall be of double deck arrangement for rating ≥ 2000A interleaved /non-interleaved design as per OEM. Separation of busbar shall be as per Form 3b. [ii] All the MCCBs up to 250 A shall be with thermal magnetic trip unit & above 250A shall be with microprocessor trip units. To ensure failsafe emergency tripping of the breakers (ACBs & MCCBs), it shall be supplied with continuous rated shunt trip coils. [iii] Necessary control and switching devices to execute the switching and control logic shall be deemed inclusive of the scope of supply irrespective of them being specified / not specified above or in the SLD. [iv] The Panel / Switchboard shall be tested to withstand vibration caused by an earthquake in accordance with IEC 60068-3-3:2013 or IS 1893 Zone V. [v] The Panel shall be purchased from the original equipment manufacturer (OEM) or OEM authorized franchises only. [vi] All the necessary noble components (viz., structural, Door noble like hinge, Bush, Door alignment guage and Bus bar noble - Bus bar support, Close profile structure - horizontal & vertical) of the Panel shall be supplied by the OEM. [vii] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative. [viii] The Contractor shall intimate the Engineer-in-Charge of the routine tests in the OEM factory in presence of a representative nominated by the Engineer-in-Charge before dispatch.
Supply, installation, testing and commissioning of factory made, CPRI / ERDA type tested, fully compartmentalized bolted type VERTICAL TRANSPORTATION PANEL (VTP) (design verified assembly- DVA) of suitable size conforming to IEC 61439-1 & 2 and IEC 61641 and having modular extensible design suitable for indoor mounting, internal arc compliance of minimum 70 kA for 0.5 s, made out of 2.0 mm thick mild steel CRCA sheet, having both sides openable with hinged doors and locking arrangement, IP 43 & IK 10 protection, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enamelled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3-Phase, 4-Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete all as specified and directed by the engineer-in-charge. The VTP shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 400 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] Circuit Breaker (a) 400 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having microprocessor based trip unit, adjustable overload setting, adjustable short-circuit setting, adjustable neutral protection, electrical interlocking, front indication LEDs, etc.- 01 Nos. [ii] Instrumentation & Measurement (a) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. (b) 400/5A Cl. 1.0 C.T. with 10 VA burden- 01 Nos. (c) 6A, 10kA, 415V, 50 Hz 4P MCB- 01 Nos. [iii] Indication & Annunciation (a) LED phase indicators (Red, Yellow, Blue)- 01 Set (b) LED status indicators (ON, OFF, TRIP)- 01 Set [C] OUTGOING [i] Circuit Breaker (a) 100 A, 415 V, Ics = 100% Icu = 25 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2: 2016, having thermal magnetic trip unit, adjustable overload setting, adjustable short-circuit setting, front indication LEDs, etc.- 02 Nos.
NOTES: [i] The APFC Panel shall be sourced directly from the OEM only.The APFC Panel described as above complete in all respect as per specification enclosed, up to the entire satisfaction of engineer-in-charge. [ii] To ensure safety, reliability and accountability of component co ordination, all the major capacitor bank components such as capacitor units, de tuning reactors, PF controllers, circuit breakers, contactors and the enclosure system called for in this specification should preferably be from a single manufacturer. [iii] The OEM shall manufacturer PFC components and switchgear.The OEM's specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf. The APFC Panel manufactured by OEM's only will be accepted & factory acceptance test (FAT) will be carried out at OEM's plant only. [iv] The APFC Panel shall have 10% extra space for future expansion. [v] The Contractor shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances, typical GADs, etc. to the engineer-in-charge for approval of the MEP Consultant and thereafter A.O. / representative.
Supply, installation,testing & commissioning of UL listed tube based Panel Fire Supression System having 4 kg automatic fire cylinder of CO2, linear pneumatic detection tube, CO2 discharge tubing with nozzles for protected panel space, master control unit having LED flasher, electronic hooter, LED indicator, silent switch, etc. with a provision for integration with the FACP along with all necessary accessories complete all as specified and directed by the engineer-in-charge.
M & L for 1.1 kV grade XLPE insulated armoured cable 4 core 4 mm2 , 2XWY conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge.
S & F of perforated hot dipped galvanized iron cable tray having galvanization thickness not less than 50 microns and perforation not more than 17.5% including fittigs viz. joints, bends, tees, etc. in convenient sections of length complete all as specified and directed by the engineer-in-charge. (a) 300 mm X 50 mm X 1.6 mm
(b) 150 mm X 50 mm X 1.6 mm
(c) 100 mm X 50 mm X 1.6 mm
M & L for copper strip of size 50 mm X 6 mm with saddles and fixing screws etc. with all accessories as specified and directed by engineer-in-charge.
M & L for GI strip of size 65 mm x 10 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
M & L for GI strip of size 50 mm x 6 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
M & L for GI strip of size 40 mm x 6 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
M & L for GI strip of size 25 mm x 6 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.
INTERNAL WATER SUPPLY:- S&F Pillar Cock (Low-flow) 16 mm dia. Make - Jaquar Model No KUP-35001PMG or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge
S&F bib cock with wall flange quarter turn (Low-flow) 16 mm dia. Make - Jaquar Model No KUP-35037PMGE or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge
S & F Stop valves, fancy type, chromium plated, with long shank and cup (concealed type), screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S & F Angular Stop Cock 15 mm bore of pipe (16 mm outer dia) with Wall Flange chromium plated Stop valves Make - Jaquar Model No KUP-35053PM or equivalent complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
INTERNAL ELECTRIFICATION:- S & F of 4' waterproof surface mounted / suspended batten having LED light source engine delivering full window illumination, integral fixed output driver, SY120° / diffused light distribution, luminous flux ≥ 4400 lm, luminous efficacy ≥ 120 lm/W, power consumption ≤ 34 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD < 20%, power factor > 0.85, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5 kV with polycarbonate co-extrusion housing, high transmittance PC diffuser, IP65 & IK08 protection, BIS appprobation & RoHS sustainability compliance and suitable for 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range -10 to 45 °C, class B serviceability, along with Click Fix mounting bracket and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Philips WT150C LED 40S 6500 PSU L120 or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of 4' surface mounted / suspended batten having LED light source engine delivering full window illumination, integral fixed output driver,120° beam angle of light source, luminous flux ≥ 4000 lm, luminous efficacy ≥ 120 lm/W, power consumption ≤ 34 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, power factor > 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 4 kV with steel housing, polycarbonate optical cover / lens, IP20 & IK02 protection, and and suitable for mounting on normally flammable surfaces, 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class I safety, along with surface / suspended (asymmetric / symmetric) mounting device and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify BN308C LED40S-6500 L120 PSU WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of surface mounted circular downlight with integral fixed output driver having LED light source engine, luminous flux ≥ 1200 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 11 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) > 80, SDCM < 5, THD < 10%, Power Factor ≥ 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, surge protection level ≥ 2.5 kV with aluminium pressure die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, safety class I, and suitable for mounting on normally flammable surfaces, 220- 240 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, overall diameter ≤ 7" (175 mm) and fixture height ≤ 60 mm along with mounting bracket and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify SM296C LED12S-6500 PSU WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1200 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 11 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5 kV with aluminum die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 130- 320 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia ≤ 5" (125 mm) and fixture height ≤ 40 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify DN296B LED12S-6500 PSU WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 1500 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 13.5 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5 kV with aluminum die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 130- 320 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia ≤ 5" (125 mm) and fixture height ≤ 40 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify DN296B LED15S-6500 PSU WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of low height recess mounted downlight in circular form-factor with non-integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 2000 lm, rated luminous efficacy ≥ 110 lm/W, power consumption ≤ 18 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD(i) < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5 kV with aluminum die cast housing and polycarbonate optical cover / lens material, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 130- 320 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, ceiling cutout dia ≤ 5" (125 mm) and fixture height ≤ 40 mm along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify DN296B LED20S-6500 PSU WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of recess mounted 2' X 2' panel fixture with integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 3000 lm, rated luminous efficacy ≥ 120 lm/W, power consumption ≤ 26 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) > 80, SDCM < 5, UGR < 16, THD < 10%, Power Factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 2.5 kV with CRCA housing and PS diffusre, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify RC600B M LED30S-6500 PSU W60L60 WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of recess mounted 2' X 2' panel fixture with integral fixed output driver having LED light source engine, luminous flux ≥ 4200 lm, rated luminous efficacy ≥ 120 lm/W, power consumption ≤ 35 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, THD < 10% (at full load), power factor > 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs, surge protection level ≥ 4 kV with CRCA housing and polystyrene diffuser, IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: RC380B LED42S-6500 G6 L60W60 PSU OD or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux NOTES:- [i] The contractor shall furnish an LM80 report issued by the OEM and LM79 report from an NABL accredited laboratory.
S & F of recess mounted 4' X 1' panel fixture with integral fixed output driver having LED light source engine, 120° luminaire light beam spread, luminous flux ≥ 4400 lm, rated luminous efficacy ≥ 120 lm/W, power consumption ≤ 36.6 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) CRI90/R9<gt/>50 options, Indirect Lighting component, SDCM < 3 , UGR < 16, THD<10%- (higher power factor, lower peak currents, and higher efficiency) power factor ≥ 0.95, median useful life L70B50 @ Ta = 45 °C ≥ 50000 hrs,Safety class-I, surge protection level ≥ 2.5 kV with CRCA housing andOpal diffuser in polycarbonate cover,Ripple Current - 5% IP20 & IK02 protection, EMI / EMC (B1) compliant, and suitable for 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class B serviceability, along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify RC600B M LED40S-6500 PSU W60L60 WH or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux
S & F of LED strip of dimension 1 mm X 8 mm X 5000 mm (H X W X D) for indirect illumination of false-ceiling coves in officers' chambers having 120° luminaire light beam spread, symmetric optic, luminous flux ≥ 800 lm, luminous efficacy ≥ 105 lm/W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 4000K, colour rendering index (CRI) ≥ 80, SDCM < 5, power factor (fraction) > 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 30000 hrs, 2P connection unit and 1P cables without plug, with aluminum housing, IP20 protection, RoHS compliance and suitable for 24 V DC input voltage, ambient temperature range -20 to 35 °C, class III safety, along with all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Signify LS170S LED8 840 IP20 L5000 or equivalent model of Bajaj, Crompton, Lighting Technologies, Trilux
S & F LED Bathroom light suitable for wall mounting & 220- 240 V, 50 Hz mains voltage with built-in LED & driver, power rating ≤ 8 W, including IP 20 protection as well as electrical connection with 3 core 1.0 mm² PVC insulated copper conductor unarmoured cable to the fixture complete all as specified and directed by engineer-in-charge. Make: Philips PHILIPS 34034 7.5W Wall Light, Silver or equivalent model of Make given in PS.
S & F of 4' wall-mounted bulkhead having LED light source engine, integral fixed output driver,120° luminaire light beam spread, luminous flux ≥ 700 lm, luminous efficacy ≥ 107 lm/W, power consumption ≤ 6.5 W, power consumption tolerance ±10%, initial corrected colour temperature (CCT) 6500K, colour rendering index (CRI) ≥ 80, SDCM < 5, power factor (fraction) > 0.90, median useful life L70B50 @ Ta = 45 °C ≥ 25000 hrs, surge protection level ≥ 2 kV with aluminum die cast housing, polycarbonate optical cover / lens, IP65 & IK08 protection, and suitable for mounting on normally flammable surfaces, 140- 270 V input voltage, 50 Hz line frequency, ambient temperature range 0 to 45 °C, class I safety, along with wall-mounting bracket and all necessary accessories complete all as specified and directed by the engineer-in-charge. Make: Philips WT140W LED7S CW PSU S1 PC or equivalent model of Make given in PS.
S & F of wall fan having blade sweep 450 mm, air delivery ≥ 125 CMM, operating voltage 220- 240 V, frequency 48-52 Hz, complete all as specified and directed by the engineer-in-charge. Make: Atomberg, Crompton, Bajaj, Usha, Orient or equivalent model of Make given in PS.
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed by engineer-in-charge. Make: Crompton Cat-Part No. VENTILUS 10" or Havells Cat-Part No. Ventil Air - DX White or BAJAJ Cat-Part No. Maxima DX
S & F engery efficient metalic exhaust fan having blade sweep 300 mm, air delivery not less than 6000 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed by engineer-in-charge. Make: Crompton Cat-Part No. EXHD300- 4-1 or equivalent model of Havells Cat-Part No. Ventil Air - DSP or BAJAJ Cat-Part No. Max Air
S & F modular type 25/32 A SP MCB, conforming to IS 60898- 1: 2002 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Make: Legrand Mylinc Cat. Part No. 6759 74 or equivalent model of Make given in PS.
S & F modular type 3 pin 25/32 A socket, conforming to IS 1293: 2005 complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. Make: Legrand Ekinox³ Cat-Part No. 5734 66 or equivalent model of MK Cat-Part No. W26427, or Havells Cat-Part No. AHOKCXW251 or equivalent model of Make given in PS.
S & F factory made not less than 1.2 mm thick sunken, modular flush sheet galvanized metal enclosure haing zinc coating not less than 120 GSM, , conforming to IS 14772: 2000, having top, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover-plates complete all as specified and directed by the engineer-in-charge. (a) 8 module Make: Legrand Arteor Cat-Part No. 6890 42 or equivalent model of Havells or Anchor or equivalent model of Make given in PS.
S & F vertical triple pole & neutral, double door, metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed by engineer-in-charge. NOTES:-[i] FP MCCB & SP/TP MCBs shall be measured and paid separately. (a) vertical triple pole & neutral double door DB, 6 way
(b) vertical triple pole & neutral double door DB, 4 way
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. (a) 6- 32 A, 230 V, 50 Hz, SP MCB (C curve)
(b) 6- 32 A, 230 V, 50 Hz, SP MCB (D curve)
(c) 40- 63 A, 230 V, 50 Hz, SP MCB (C curve)
(d) 6- 32 A, 415 V, 50 Hz, TPN / FP MCB (C curve)
(e) 6- 32 A, 415 V, 50 Hz, TPN / FP MCB (D curve)
(f) 40- 63 A, 415 V, 50 Hz, TPN / FP MCB (C curve)
S & F residual current device (RCD) conforming to IS 12640 (Part 2): 2016, assembled for AC applications having front face indication for earth leakage fault, sliding shutters, IP 20 protected terminals suitable for cable sizes up to 35 mm² , colour coded on / off indication on dolly, integrated label holder, etc. complete all as specified in IS 732: 2019 and directed by the engineer-in-charge. (a) 20 A, 30 mA. 230 V, 50 Hz RCBO
S & F moulded case circuit breaker (MCCB), four pole, in single frame size up to 250 A with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 1.5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% Icu = 25 kA as per IEC 60947-2 complete all as specified and directed by engineer-in-charge (a) 32 A, 415V, 25 kA, 50 Hz 4P MCCB
(b) 63 A, 415V, 25 kA, 50 Hz 4P MCCB
(c) 100 A, 415V, 25 kA, 50 Hz 4P MCCB
M & L for 1.1 kV grade XLPE insulated armoured cable conforming to IS 7098 (Part 1): 1988, having stranded compact shaped conductors as per Cl. 2 of IS 8130: 1984, PVC inner sheath, single armouring of galvanised steel strip/wire and PVC Type ST-2 outer sheath conforming to IS 5831: 1984, including necessary clamping / dressing with cable ties and termination complete as all specified and directed by engineer- in- charge. (a) 4 core 10 mm2 , 2XWY
(b) 4 core 6 mm2 , 2XWY
(c)4 core 4 mm2 , 2XWY
S & F 300 x 300 x 60mm Terracotta brick tile with natural colour jointed with K2 adhesive complete all as specified and directed by Engineer-in charge
M & L steel work in tubular farme including special shaped washer etc including painted one shop coat of zinc chromate primer paint (including preparation of surfaces) complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St;240
M & L framed work such as grills, gratings etc.. With ends of bars shoulered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, ralings… etc complete all as specified & directed
S & F 6mm thick Galvanized Mild steel plate with CNC laser cuttings (Designer plate) complete all as specified & directed
S & F plain or corrugated steel sheets of any thickness of suitable size etc complete all as specified & directed
S & F MS wire rope for fixing the structure etc complete all as specified & directed
Supply and fixing Cubicle Work Station of following description, size & Shape, colour made with first quality Ply wood with decorative sunmica of any colour, glass work as directed by Engr-in-Charge (i) 25mm thick Ply - 120 Sqft (ii) 2mm thick PVC Edging - 152 Rft (iii) 0.6mm decoraticve laminate sheet - 112 Sqft (iv) Modular wire manager ABS Plastic - 1Nos (v) 18mm thick Ply - 66 Sqft (vi) 12mm thick Ply - 55 Sqft (vii) 9mm thick Ply - 62 Sqft (viii) Telescopic Channel -4Nos (ix) Auto Close hydraulic - 05 Nos (x) Lock - 03nos (xi) Caster wheel - 04Nos (xii) SS Handle - 03Nos (xiii) 8mm thick frosted glass -05Sqft
Supply and fixing Cubicle Work Station of following description, size & Shape, colour made with first quality Ply wood with decorative sunmica of any colour, glass work as directed by Engr-in-Charge (i) 25mm thick Ply - 58 Sqft (ii) 18mm thick Ply - 26 Sqft (iii) 12mm thick Ply - 24 Sqft (iv) 9mm thick Ply - 24 Sqft (v) Metal tray for keyboard with mouse- 04Sqft (vi) Metal for CPU - 09Sqft (vii) 0.6mm decoraticve laminate sheet - 82 Sqft (viii) 2mm thick PVC Edging - 60Rft (ix) Modular wire manager ABS Plastic - 1Nos (x) Aluminium locking arrangement - 01Nos (xi) 1.2mm aluminium frame -04Sqft (xii) Telescopic Channel -4Nos (x) Lock - 03nos (xi) Caster wheel - 04Nos (xii) SS Handle - 03Nos (xiii) 8mm thick frosted glass -08Sqft
Supply Chair for Work Station (Cubical & Linear). High Back Ergonomical Office Chair with Adjustable Arms and Tilt lock Mechanism. Weight 15 kgs. Colour Black. Dimensions 44x44x22cm. Upholstery Mesh type. Finish Chrome. Weight Cpacity 120 Kg. Frame Material Plastic, Alloy Steel and Nylon . Adjustable seat height, Height adjustable headrest, Swivel, Anyposition tilt locking mechanism, Lumbar support with height and depth adjustment, Adjustable armrest with soft top. Make Godrej/ Nilkamal/ Durian/Savya/Featherlite
Supply and fixing Compactor MS1 10 MC (Size 4500x2100 mm). Overall Ht-2130mm, Body Ht-1980mm, W-915mm, D-457mm, powder coated bodies with shelves-CR-22 No of shelves per body-04 (Compartment-05) Powder coated base frames in HR-16G-120mm base Ht powder coated track channels in HR-14G No of MS wheels in each movable base frames-4Nos. C-formed track channel welded with bright flat of 32x16mm. Centralized locking arrangement. PP-handle for easy driving chain & sprocket arrangement for driving the units. A total of 54 units each comprising of 05 compartments. Make Godrej/ Zuaril/ Durian/Methodex/Featherlite
M & L 200mm dia DWC PE pipes for sewage line laid and jointed as per manufacturer's instructions and as specified and directed. Make:- Rex/Poly/Gemini
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of chilled water type central air conditioning plant of capacity 2 x 135 TR installed, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Coast Guard Station Gandhinagar
1st year after expiry of defect liability .
2nd year after expiry of defect liability.
3rd year after expiry of defect liability.
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of Sewage Treatment Plant 15 KLD, comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Coast Guard Station Gandhinagar
1st year after expiry of defect liability .
2nd year after expiry of defect liability.
3rd year after expiry of defect liability.
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of 03 numbers Passenger Lift (13 Passengers/884 Kgs), comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Coast Guard Station Gandhinagar
1st year after expiry of defect liability .
2nd year after expiry of defect liability.
3rd year after expiry of defect liability.
Comprehensive maintenance comprising of routine, preventive & breakdown maintenance of 01 number Goods Lift (2000 Kgs), comprising of all devices and accessories through out 12 months on all days including sundays & holidays for a period of 03 years after expiry of defects liability period (i.e. 24 months after completion of all Phase II tests) all as specified and directed and as shown below: at Coast Guard Station Gandhinagar
1st year after expiry of defect liability .
2nd year after expiry of defect liability.
3rd year after expiry of defect liability.
Notes:- (i) Comprehensive maintenance consists of preventive and breakdown services including repair and replacment of all consumables like topping of gear oils/grease/door rollers etc and any hardware including rewinding of motor etc and load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the following (ii) Preventive maintaince consists of carrying out routine check by skilled personnel deputed by OEM as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart. (iii) Breakdown maintaince consists of attending to the faults that may occur and carrying out necessary repairs/replacement to electrical control circuits and electrical/mechanical components of the lift that may occur during the operation. (iv) Fortnightly,monthly,quarterly,halfyearly and yearly maintaince registeres shall be maintained and signed by site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge. (vi) Any delay in attending breakdown will attract penalty @ Rs 500 for first 8 to 16 Hrs after receiving complain and @Rs 1500 for every 24 Hrs of delay in rectification of complain. (vii) Payment will be released only after successull completion of maintenance as per schedule described here in before and submission of record signed by all concern persons Note-2 The contracto has to submit the AMC agreement with the OEM before the completion of defect liability period for commencement of item above
Outsourcing of services for operation of Lifts (1 shifts - General shift per day except Sunday/Holiday) during office hours excluding sundays and holidays including daily cleaning/maintenance of lifts etc, by one skilled lift operator all as specified and directed as under : Installation Location : Coast Guard Station Gandhinagar Details of equipments installed are as under :- 1. Passengers Lift(13 passengers / 884 kgs) -03 nos. 2. Goods Lift(2000 kgs rated load) -01 nos.
1st year after completion of Work.
2nd year after completion of Work.
3rd year after completion of Work.
4th year after completion of Work.
5th year after completion of Work.
Outsourcing of services for operation of Air conditioner screw type water cooled chiller machine for for 02 shifts of 8 hours each shift per day except Sunday/ Holiday) excluding sundays and holidays by semi-skilled FGM and routine maintenance of Machinery installed, all as specified and directed are as under : Installation Location : Coast Guard Station Gandhinagar Details of Installed Machinery :- AC Plant 2x135 Tr. --01 nos. Note :- (i) Maintain the record of installation as per format given by JE E/M (ii) Cleaning inside and outside/surrounding of installation are deemed to be included in the unit rate. (iii) The valves shall be operated on number of times, in a day as directed by JE. (iv) Necesary T&P will be provided by the contractor for minor repairs if any, without any extra cost. (v) The alternative arrangement of reliever employed without any exra cost is the sole responsibility of the contractor.
1st year after completion of Work.
2nd year after completion of Work.
3rd year after completion of Work.
4th year after completion of Work.
5th year after completion of Work.
Outsourcing of services for operation of 11 KV Sub Station , TOP, round the clock (3 shifts per day) including sundays and holidays including daily maintenance of VCBS, DG Set etc, by one skilled electrician all as specified and directed as under :. Installation Location : Coast Guard Station Gandhinagar Routine maintenance of equipments installed are as under :- Transformer 1000 KVA -01 No, DG Set 750 KVA - 01 No, 11 KV VCB - 01 No LT Panel with APFC Panel-01 nos. Notes :- (i) Power Factor of Sub stations is to be maintained not less than 0.95.If the power factor is less than 0.95, the same shall be brought to the knowledge of the concerned JE, in writing for taking necessary corrective measures, if there is any failure in intimation and has resulted in penalty by PGVCL, the contractor shall be liable to pay the penalty. (ii) Maintain records as directed by JE E/M or Engr-in-charge (iii) Cleaning inside and outside/sorrounding of the installation are deemed to be included in the unit rate. (iv) Replacement of DO fuse including material is deemed to be included in the unit rate . (v)Diesel for operation of DG sets,shall be issued under Sch 'B' at Free of Cost. The transportation from store yard to installation shall be borne by the contract.The barrels required for collection and storing of Diesel shall be proividing by the department. (vi) The alternative arrangement of reliever employed without any exra cost is the sole responsibility of the contractor.
1st year after completion of Work.
2nd year after completion of Work.
3rd year after completion of Work.
4th year after completion of Work.
5th year after completion of Work.
Outsourcing of services for operation of Fire Fighting equipments, pump set of any cap installed at Water Supply installation, and Sewage Treatment plant etc in 02 shifts of 8 hours each including sundays and holidays by FGM and routine maintenance of Pumps, Machinery installed, all as specified and directed. Installation Location : Coast Guard Station Gandhinagar Details of Installed Machinery :- Sewage Treatment Plant:- 1. Capacity -15 cum/day--01 nos. 2. Air blower -08 nos. 3. Submersible Pump (3 HP) -04 nos 4. Submersible Pump (5 HP) -08 nos 5. Panel Motor Control --------02 nos Fire Fighting equipments:- 1.Fire fighting Panel 2. Jockey pump 3. Diesel pump Note :- (i) Operator will maintain the record of Chlorination. (ii) Maintain the record of installation as per format given by JE E/M (iii) Cleaning inside and outside/surrounding of installation are deemed to be included in the unit rate. (iv) The valves shall be operated on number of times, in a day as directed by JE. (v) Necesary T&P will be provided by the contractor for minor repairs if any, without any extra cost. (vi) The alternative arrangement of reliever employed without any exra cost is the sole responsibility of the contracto
1st year after completion of Work.
2nd year after completion of Work.
3rd year after completion of Work.
4th year after completion of Work.
5th year after completion of Work.
Note for Item No 18.93 to 19.16 :- (a) The contractor has full resposibility to maintain the surrounding area neat and clean (b) Safety precaution should be maintained properly. Safety shoes,belt, helmet etc. required to the working staff would be provided by the contractor without any extra cost to the department. The same is included in this schedule. (c) T&P required for maintenance and repair work will be provided by the contractor without any extra cost. The same is included in this schedule. (d) Dress to the working staff will be provided by the contractor without any extra cost to Govt. (e) Daily attendance register, Log Book will be maintained by the contractor properly. (f) Daily attendance register,Log Books and statonary required for this work will be provided by the contractor wihout any extra cost. (g) The work will be carried out 7 days week. Necessary reliever will be provided by the contractor without extra cost to the Govt (h) Manpower involved in operation of plants can be utiised (rotation of duties) as direted by Engr in charge. (j) Tiimg of shifts shall be as directed by Engr in charge.
vijay infraprojects pvt ltd
SHREE GURUKRUPA CONSTRUCTION CO.
LUMOS INFRA PVT LTD
M/s Matadeen Ramchandra Agarwal
Agarwal Jagdish Construction Company Pvt. Ltd.
NAND LAL PURI AND SONS PRIVATE LIMITED
surendra infrastructure pvt ltd
NARSINGH DEVELOPERS LLP
GANGA INFRABUILD PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
B D Raizada Projects Pvt Ltd
DES RAJ AND SONS BUILDERS PVT LTD
Hariom Projects Pvt Ltd
stage.html
html • 0.09 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid