| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-Finance | ₹7.4 L | L1 | Accepted-Finance LOWEST |
| 2 | L2₹7.9 L+₹46,000 (6.19%)Accepted-Finance | ₹7.9 L+₹46,000 (6.19%) | L2 | Accepted-Finance 2ND LOWEST |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
14 Jan 2021, 9:00 amClosed
Executive Engineer
Executive Engineer
supply installation testing and commissioning of 28m3/hr 8HP open well submersible pump
2020_PWD_1826_1
MDK/e-NIT/40 of 2020-21
Open Tender
Pumps/Motors
Turn-key
180 days
Lathang Drass
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
Executive Engineer
₹20,000
office of the Executive Engineer Mech Div Kargil
8 Feb 2021
2 Jan 2021
14 Jan 2021
2 Jan 2021
14 Jan 2021
3 Jan 2021
8 Jan 2021
Amount
Design, Supply, installation, testing and commissioning of 02 No. Multistage Vertical Open-Well Submersible Pump (01 running + 01 standby) with SS Impeller, SS stage casing, CI suction casing, mechanical Seal, bearing lubrication oil, coupled to energy efficient squirrel cage induction Motor resting. The motor shall be suitable for three phase 415 V ± 10%, 50 Hz supply. The job includes installation of the pump set at floor level of the Dug-well/ sump by way of suspending it from hoist platform on 02 No. High class steel wire rope (fastened either side of pump set) to support the live load of the pump and accessories. The pump shall be fitted with delivery pipe up to top of the well of MS make, 78 mm dia. with 01 No. Cast Iron NRV, 01 No. Cast Iron sluice valve, 01 No. Long radius bend, common pressure header of nominal dia. 78 mm with Flanges confirming to IS:3589-2001 GR:330 ERW C.S Steel Tube, Cork sheet Gaskets, Nuts Bolts with washers. The size of the NRVs, Sluice Valves and suction pipe shall be in accordance with the size of the pump i,e (Delivery). Capacity of Pump(min) = 28m3/Hr Total Dynamic Head = 43 mtr Speed =2900 RPM Efficiency ≥ 70% Driving Motor Rating at 415V ± 10%,50Hz = 8 HP Speed =2900 RPM Insulation = F-class
Star Delta Type Control Panel Design, fabrication, assembling, wiring, Installation testing and commissioning of fixed type, floor mounted, cubical design motor control centre suitable for 8 HP pumping set having Incoming MCB (ISI marked) of minimum 15 Amps manually operated with adequate space below for easy connection & operation. One number Volt meter, one number Ampere meter of suitable range shall be installed inside the panel. For phase indication, indication lamps, one number for each phase, of reputed make shall be provided. Control panels shall be equipped with three ISI marked Contactors, unit one for line, second for the Star connection and the third for the Delta connection, marked Thermal Over load Relay and Type Tested Single Phase Preventing Preventer. Delta connection shall be achieved by preset timer relay transmission period adjustable by suitable timer. ISI marked Contactor rating of main and delta contactor shall be of minimum 15 Amps. ISI marked Thermal Over Load Relay of 16 Amps and Type Tested Current sensing type Single Phasing Preventer of suitable rating. Complete job includes - all sheet metal components shall be de-rusted, degreased and shall be painted with two coats of synthetic enamel paint (light grey, grey)
Fully Automatic Voltage Regulator Duly Filled With Recommended Oil Upto Full Capacity Type = Fully Automatic Servo Voltage Regulator Rating = 15 KVA Input Voltage Range (Phase To Phase) =270-460 V Output Voltage Range (Phase To Phase) =415±10% Output Wave Form = True To Input Input Frequency = 45-55 Hz Response Time = 10 Msec Correction Speed = 25-65 V/Sec Correction Method = Stopless Correction Cooling = Oil Efficiency = Better Than 98% Control Circuit = Fully Automatic IC based solid stat, Operation = Fully Automatic Suitability = Suitable For 3-Phase Unbalanced Supply, Unbalanced Load OPERATING TEMPERATURE = -15°C TO 45°C Additional Features: i)High and low voltage cutoff system. ii)Over load and short circuit protection iii) Single phase prevention system. iv) Phase sequence change protection. v) Earth fault protection. vi) High grade CRGO lamination. vii) Simple rugged construction. viii) 99.9% pure copper. ix) High efficiency. x) Negligible wave form and power factor distortion. xi) Smooth and step less voltage control.
Miscellaneous Works: Providing of 01 no Manual Operated Triple Spur Gear Chain-Pulley Block ISI marked Of 500 Kg Capacity & Minimum Lift 12 mtr along with U-clamps with nuts & bolts -10 Nos, Tool kit – 01 set and 12mm dia. steel wire rope of 25 meter length.
Providing and Laying of 80 mm dia delivery pipe line: Providing and Laying of 110 meter MS pipe 3" (80 mm nominal Dia.) medium grade from Pump House to Delivery Point along the surface. Joints to be fitted with flanges min 8 mm confirming to IS:3589-2001 GR:330. Job includes p/f of long radius bends required as per site conditions, Carbon steel nut-bolts with washer and 3mm cork sheet gaskets of flange size( or any other materials best suited for high pressure leak proof joints), Job includes all earth works , RCC post for proper anchorage of pipes at recommended spaces (20 feet c/c spacing), and tools and tackles complete: Specifications: M.S Schedule 40 / ERW Pipe, Medium Grade Nominal Bore Size = 80 mm (3") Wall Thickness = 5.50 mm Internal Dia. = 77.90 mm Total Length = 110 Mtr. The job includes construction of RCC block with steel clamps, nuts & bolts at 20 feet c/c spacing = 20 Nos
M/S HIGHLAND ENGINEERING
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .