Assistant Executive Engineer
PWD Electrical Sub Division kottayam
GENERAL Supply and installation of 8KWP On Grid Solar and connected Electrical works Erumeli rest house,Kottayam SITC of solar panel at Rest House General Electrical Work
2026_PWD_861870_1
ESDK_ET_60_2026-2027
Open Tender
Electrical Works
Item Wise
180 days
Kottayam
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,675
₹18,946
22 Jul 2026
22 Jul 2026
31 Jul 2026
22 Jul 2026
29 Jul 2026
22 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ON grid solar | |||||
| 1.001 | OD279533/2024-2025:Supply and providing wall mounted on grid solar Power Conditioning Unit (PCU) of
200-1000 V DC Input voltage range or nearest range and 400V AC, three phase, 4
wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency
not less than 97%, total harmonic distortion less than 3% and suitable for ambient
temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency
level to suit the Grid Voltage Frequency and adustiable for connecting time to grid as
per KSEB norms, including Data Monitoring System complete with accessories
wifi/LAN connecting and connected application software etc. fixing on wall using
wall brackets and giving all connection as required | - | kW | - | - |
| 1.002 | OD279532/2024-2025:Supply and providing Solar Photovoltaic Module Mono Perc Half Cut of capacity
540 Wp or nearest size, manufactured in India, conforming to IS 14286/IEC 61215,
IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion
efficiency shall not be less than 16.5%. PV modules used in solar power plants/
systems must be warranted for their output peak watt capacity, which should not be
less than 90% at the end of 10 years and 80% at the end of 25 years. fixing on
existing steel frame work using nut bolts/screws etc in suitable direction at site
condition and giving connection and inter connection wire tied using suitable steel
wire tie as per the system string design and direction of department staff | - | each | - | - |
| 1.003 | OD279534/2024-2025:Supply and providing wall mounted AC DB for on grid solar system for connecting
Inverter AC side consists of a). Poly carbonate Enclosure IP65 protection with
trasperant front cover with hinged door and termination arrangement, b). SPD
Up1.5kV,Up 335VDC In 20kA, Imax 40kA and giving internal connection using
suitable wire, c). 6-32A 4Pole AC MCB for outgoing side, giving all connection and
DB fixing on wall using suitabel screws and plugs ets as required. | - | each | - | - |
| 1.004 | OD279535/2024-2025:Supply and providing wall mounted DC DB for on grid solar system for connecting
2Nos solar panel string and DB consists of a). Thermoplastic Enclosure IP65
protection with transparent front cover with hinged/screws door and termination
arrangement, b). 2set 20A DC Fuse and Holder for +ve and connector for -ve
incomer side, c). 2set SPD 1000V DC Up1.9kV,Ucpv 585VDC, In 15kA, Imax 40kA
and giving internal connection using suitable wire, d). 2set of 10 - 20A 2Pole DC MCB for outgoing side, giving all connection and DB fixing on wall using suitable
screws and plugs ets as required. | - | each | - | - |
| 1.005 | OD279525/2024-2025:Supplying and drawing 1run x 4 sq. mm PVC insulated tinned copper conductor, single core Solar DC cable in the existing surface / recessed steel/ PVC conduit as required. | - | metre | - | - |
| 1.006 | OD279528/2024-2025:Supply & installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB- 6545) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required. | - | each | - | - |
| 1.007 | 2.10.5:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Triple pole and neutral | - | each | - | - |
| 1.008 | OD279527/2024-2025:Supplying and fixing Three phase 4wire KWh meter, 415V, 10 - 100 A range ,electronic type in the existing meter board complete with connections, testing and commissioning etc. as required (including testing if required, test certificate for submitting KSEB). | - | each | - | - |
| 1.009 | OD279523/2024-2025:Supply and wiring with PVC insulated stranded single core copper conductor cables for interconnecting the control devices/ equipment's including the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required. 10Sqmm single run | - | metre | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbd.pdf
Tender Documents • 2.30 MB
BOQ_1457595.xls
BOQ • 0.33 MB
LISTOFMATERIALS.pdf
Other Document • 0.20 MB
Specificcondition.pdf
Other Document • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].