| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹43.8 LAccepted-AOC | 1st | Accepted-AOC Being Lowest | |
| 2 | 2nd₹46.4 L+₹2.2 L (4.91%)Rejected-Finance SHOP NO 1 KARGI CHOWK HARIDWAR BY PASS DEHRADUN UTTARAKHAND | 2nd | Rejected-Finance Being Not Lowest | |
| 3 | 3rd₹46.5 L+₹2.3 L (5.18%)Rejected-Finance | 3rd | Rejected-Finance Being Not Lowest |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
2 Apr 2021, 6:00 pmClosed
CHIEF ENGINEER R AND D DELHI
CE R and D Delhi Timarpur New Delhi 54
SPECIAL REPAIR FOR REPLACEMENT OF AC UNITS AT DEHRADUN
2021_MES_418622_2
CE Rand D DLI 24 DDN 2020 21
Open Tender
Civil Works
Item Rate
180 days
Dehradun
as Per NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE I R AND D DEHRADUN
₹1.1 L
Yes
3 May 2021
12 Mar 2021
5 Apr 2021
12 Mar 2021
2 Apr 2021
19 Mar 2021
12 Mar 2021 - 19 Mar 2021
Amount
Demlition of brick or stone boulders masonry built in cement mortar or cement lime mortor including all quions, arches, pillars etc but excluding ashlar facing, dressed stone works and precast concrete articles, complete all as specified and as directed.
M&L for brick work withsub class B bricks straight or curved on plan exc 6mtr mean radius built in cement mortar 1:6, complete all as specified and as directed.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of concrete/brick sufaces finished fair and even without using extra cement, complete all as specified and directed.
M&L for rendering 5mm thick in cement mortar 1:3 on ceiling of concrete/brick sufaces finished fair and even without using extra cement, complete all as specified and directed.
M&L for preparing old surfaces of walls plastered or un -plastered by brooming down with steel or wire brush and scraping down smoke soot, moulds moss and efflorescent salt and trading oil and greasy spots, washing, rubbing down and stopping of distempered and painted surface and removing all vegetation growth, nails and making good holes, crackes etc complete by 1 mm thick putty in two coats and making the surface smooth by rubing with sand papers etc. and applying two coats of oil bound distemper on old prepared surfeaces of walls complete all as specified.
M& L for preparing surfaces, plastered or unplastered new surfaces on walls and applying two coats of oil bound distemper, over and inluding one coat of primer, over and including applying 1mm thick wall putty in two coats complete all as specified and as directed.
Dismantling wall and ceiling boards (fiber pulp, insulation etc.) or insulation boards/ slabs/ blankets any thickness including grid work/ aluminium frame work, cover fillets complete all as specified.
M&L for Anodised aluminium snap grid frame work for false ceiling of grid size 605mm x 605mm. Aluminium sections incorporated in frame work shall conform to IS 733, IS 737 and IS 1285. Snap grid frame work consist of anodized aluminium main/cross tee shall be fixed to ceiling with supporting hanger consisting of 6mm dia mild steel rod, J bolts with necessary bolts, nuts and washers all as per manufacturer’s instruction or directed by engineer in charge. The main and cross tees shall be jointed at junction/crossings with anodized aluminium angle bracket of size15mm x 15mm x 1.5mm, weighing 0.12 Kg per running metre, fixed with suitable mild steel, bolts nuts and washers, all as per manufacturer’s instructions or directed by engineer in charge. The snap grid (main/cross tee section) shall be supported at ends all along the wall with anodized aluminium angle of size 40mm x 25mm x 2mm, weighing 0.36 Kg per running metre, complete all as specified and directed by engineer in charge. Note:- PVC protected sheeting shall be used to avoid scratches, damage to the framework while fixing to ceiling
S&F 12 mm thick Seamless calcium silicate ceiling 8 mm thick made out of 600x600 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specified and directed . Note : Frame Work for ceiling shall be measured and paid separately
S&F anodised aluminium frame work for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified.
S&F anodised aluminium window and vantilators shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing anodised aluminim snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No), hinges type B-21 100mm long (02 No), suitable handle(01 No) for each shutter, complete all as specified and directed by engineer in charge.
Taking down chowkhats or frame of any description exc 1.5 Sqm each and n. exc. 4 Sqm ( without taking off shutters from the frame ) and removing off the premises complete all as specified.
S&F solar heat control film 25 micron reflective type sicked to glass panes as per manufacturere's instuctions complete all as specified and directed by engineer in charge.
M&L for 5.5mm thick sheet glass ordinary quality in panes exc. 0.50 Sqm each, fixed with and including rubber gasket in aluminium frame work complete all as specified.
M& L preparing surfaces , plastered or unplastered new surfaces on ceiling and two coats of distemered oil emulsion after applying 1mm thick wall putty in two coats and one coat of primer complete all as specified and as directed.
M&L for rendering 15mm thick in cement mortar 1:4 on brick surfaces, mixed with water proofing compound (WPC) (as per manufacturer's instructions), finished even and smooth without using extra cement, complete all as specified and directed. Note:- WPC measured and paid seperately
M& L preparing surfaces, plastered or unplastered new surfaces on walls and applying two coats of cement based paint and one coat of primer complete all as specified and as directed.
Supply only liquid water proofing compound (WPC) ISI Marked ( Used 200ml per cement bag) complete all as specified.
M&L for earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized iron strip 32x6 mm, (main earthing lead ) by means of galvanized bolts, nuts and washers all as shown in electrical plate No. 3 of MES SSR Part-I (2009) connected to earthing point and testing on completion with and including GI pipe 40 mm bore (upto 7.5 metre beyond outer edge of earth pit) PCC pit in mix 1:3:6 type C1 with RCC 1:2:4 type B-1 40 mm thick cover reinforced with 6 mm dia M.S bars 3 nos both ways with lifting hook made out of 6 mm dia bar, watering arrangement with funnel and wire mesh and 20 mm bore light grade G.I. watering pipe, common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed by engineer in charge
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete, all as specified and directed by Engineer-in-Charge.
M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete, all as specified.
Material & labour for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete, all as specified and directed by Engineer-in-Charge.
M&L for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete, all as specified and directed by Engineer-in-Charge.
Supply, laying, connecting & testing of galvanised iron water tubing 25 mm bore 'light grade' conforming to IS-1239 light grade as in sleeving etc laid in trenches / ducts/road / Nala etc. complete, all as specified and directed .
All as per item no 26 above but 40 mm bore
All as per item no 26 above but 50 mm bore
Supplying, Laying, testing and commissioning XLPE insulated, IS 7098 (Part-I)-1988 marked screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 50 Sqmm 3½ core with aluminium conductor 1100V grade cross section area, laid in trenches/fixed on pole/wall / passed through pipe including making necessary connection, with busbar/MCCB/DB's & testing complete, all as specified and directed by Engineer-in-Charge. NOTE: Earth work, sand cushioning, GI pipe, clamps for holding cables and brick protection shall be measured and paid separately
All as per item no 29 above but 25 Sqmm 3½ core.
All as per item no 29 above but 16 Sqmm 4 core
All as per item no 29 above but 10 Sqmm 4 core
S&F in replacement of Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole and neutral MCB 32 amp 'C' series 240Volts power coated CRCA steel sheet enclosure recess mounted with chained metal cover for the socket outlet with and including one number single pole 'C' series MCB 32 amp complete,all as specified and directed by Engr-in-Charge.
Supply, fixing, connecting & testing sheet metal enclosures DBs for using MCCB as incomer and MCBs / MCB isolators as out going suitable for three pole and neutral, 8 way with having copper bus bars of capacity 250 Amps, double metallic door, IP-54 protection, including incomer MCCB 160 Amps rating , 25 KA , 4 pole, , complete,all as specified and directed by Engr-in-Charge , conforming to IS : 13032 double door ( Note: (i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate for Incomer MCCB is deemed to be included under above item.
Supply, fixing, connecting & testing sheet metal enclosures DBs for using MCCB as incomer and MCBs / MCB isolators as out going suitable for three pole and neutral, 06 way with having copper bus bars of capacity 250 Amps, double metallic door, IP-54 protection, including incomer MCCB 160 Amps rating , 25 KA , 4 pole, complete all as specified and directed by Engr-in-Charge, conforming to IS : 13032 double door. Note: (i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate for Incomer MCCB is deemed to be included under above item.
Supply, fixing, connecting & testing sheet metal enclosures DBs for using MCCB as incomer and MCBs / MCB isolators as out going suitable for three pole and neutral, 4 way with having copper bus bars of capacity 250 Amps, double metallic door, IP-54 protection, including incomer MCCB 100 Amps rating , 25 KA , 4 pole, complete,all as specified and directed by Engr-in-Charge , conforming to IS : 13032 double door. Note: (i) Fittings like MCB’s /Isolators etc. shall be measured and paid for separately under appropriate item of Sch ‘A’. (ii) -Sheet steel enclosure to be fixed flush to wall by cutting niche & make good to the disturbed wall surface as per existing (iii) Rate for Incomer MCCB is deemed to be included under above item.
S&F MCB distribution board powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with SPN, 240 V, 8 ways AC complete,all as specified and directed by Engr-in-Charge.
S&F MCB SP 240 volts 6 to 32 Amps, 'C' series 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete,all as specified and directed by Engr-in-Charge.
S&F MCB SPN 240 volts 6 to 32 Amps, 'C' series 10 KA breaking capacity, including connection with suitable size aluminium / copper lugs complete,all as specified and directed by Engr-in-Charge.
M&L for Sub main wiring with Two single core PVC insulated unsheathed cable 1100 volts grade, 10 Sqmm size with multistranded copper conductor, drawn in including suitable size of non metallic rigid PVC conduit (concealed conduit wiring in wall and surface in ceiling ) including PVC insulated unsheathed 1x10 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete,all as specified and directed by Engr-in-Charge. Note :- 3run of 10sqmm cable and PVC conduit shall be measurd and paind as one run of unit.
M&L for Sub main wiring with Two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, drawn in including suitable size of non metallic rigid PVC conduit (concealed conduit wiring in wall and surface in ceiling ) including PVC insulated unsheathed 1x6 Sqmm cable with multistranded copper conductor green PVC insulated as contineous earth conductor cable connected to earth dolly complete,all as specified and directed by Engr-in-Charge. Note :- 3run of 6sqmm cable and PVC conduit shall be measurd and paind as one run of unit.
Supply & fix 20/22 watts LED Surface and Wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integegrated elecronic driver with all accessories duly prewired, including connecting the fitting complete,all as specified and directed by Engr-in-Charge..
Supply, fixing & testing, 36/34 watts LED edge-lit luminaire suitable for armstrong/grid ceilng with driver complte for low ceilng applicationsly with all accessories duly prewired, including connecting the fitting complete,all as specified and directed by Engr-in-Charge.
Supply, fixing & testing' Suspended architetural 40 Watts LED luminiaire provides soft-light and glare free symmetical illumination (with continuous mounting end cap) complete with all accessories duly prewired, including connecting the fitting complete,all as specified and directed by Engr-in-Charge.
M&L for point wiring with single core PVC insulated unsheathed 1100 volt grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, (concealed conduit wiring in wall and surface in ceiling ) with GI saddles GI screws, rawal plugs in ceiling or roof including Tee, Junction boxes and provision of flush metal boxes, modular white cover plate with frame suitable for modular switch, socket and fan regulator as per site requirement and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade FRLS-IS 694 cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete, all as specified for one light/Fan point controlled by one Switch. Note:- Modular socket and fan regular shall be measured and paid seperately only.
S&F Modular switch piano flush button single pole one way 6 amp complete.
M&L for earthing complete for building with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given 15mm thick plaster in cement mortar 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed by Engr-in-Charge. NOTE : RCC pit cover shall be pre-cast of RCC (1:2;4) type B-1 80 mm thick reinforced with XPM weighting not less than 4 Kgs/Sqm in lieu of CI cover.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete,all as specified and directed by Engr-in-Charge.
Installation, commissioning and testing high wall invertor Split type air conditioner unit, capacity of 2.0 TR indoor/outdoor unit complete with fixing arragement of indoor unit on wall and outdoor unit with cooling and heating function, suitable size of MS angle/ strip stand on floor/roof including suitable size of coppper tubing with nitrile insulation, electric cable and drain pipe complete from inner unit to outdoor unit as required at site, all as specified and directed by Engr-in Charge. Note : The cost of Additional required Copper tube, insulation, drain pipe and Electric cable suitable size and MS angle iron /strip for indoor/outdoor unit will be measured and paid seperately under relevent items of Schedule 'A' & high wall invertor Split type air conditioner unit, capacity of 2.0 TR indoor/outdoor unit complete with standard cable copper tube & drain will be issued by the dept under shedule 'B'
Installation, commissioning and testing only high wall invertor Split type air conditioner unit, capacity of 1.5 TR indoor/outdoor unit complete with fixing arragement of indoor unit on wall and outdoor unit with suitable size of MS angle/ strip stand on floor/roof including suitable size of coppper tubing with nitrile insulation, electric cable and drain pipe complete from inner unit to outdoor unit as required at site, all as specified and directed by Engr-in Charge. Note : The cost of Additional Copper tube, insulation, drain pipe and Electric cable suitable size and MS angle iron /strip for indoor/ outdoor unit will be measured and paid seperately under relevent items of Schedule 'A' & high wall invertor Split type air conditioner unit, capacity of 1.5 TR indoor/outdoor unit complete will be issued by the dept under shedule 'B'
Installation, commissioning and testing Automatic operation, single phase naturally air cooled indoor type wall mounted voltage stabilizer & designed for input variation between 170 V to 250 V complete with connecting lead of three core copper flexible wire and connector for out put connection complete,all as specified and directed by Engr-in-Chagre. Note:- Automatic operation, single phase naturally air cooled indoor type will be issued by the dept under shedule 'B'
Supply and fixing refrigerant copper tubing with foam type insulation sleeve 5/8" dia with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply and fixing refrigerant copper tubing with foam type insulation sleeve 3/8" dia with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply and fixing refrigerant copper tubing with foam type insulation sleeve 1/2" dia with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply and fixing refrigerant copper tubing with foam type insulation sleeve 1/4" dia with 22 gauge , fixed on wall / ceiling with saddle as per site requirement including making joints by brazing / flairing and checking for any leakage complete, all as specified and directed by Engr-in-charge.
Supply only refrigerant gas R-410A (HYDRO CARBON)
Supply & fabrication of MS shed for protection of out door unit of AC and stands of mild steel to with stand load of outdoor unit of split type AC of 2 & 1.5 Tr of suitable size of flat iron/Angle iron etc., cut to shape, including bending and welding as necessary at site etc.conforming to Fe.290.Gde-E-165, with nut ,bolts washers and applying two coats of synthetic enamel paint over a coat of red oxide primer complete, all as specified and directed by Engr-in-charge.
M&L for flexible PVC drain pipe of suitable size for drain out water from indoor unit of split AC cap 2/1.5 Tr to directed site complete, as specified and directed by Engr-in-charge. (Make : Supreme/Prince).
M&L for PVC insulated PVC sheathed 2.5 Sqmm, 3 core copper cable 1100 Volts confirming to IS complete, all as specified and directed by Engr-in-charge.
Dismantling of Old unserviceable Central AC System such as AHU/Water pump sets, cooling towers, ducting and electrical conections/ducting etc including all accessories and depositing the same in MES store yard.
OM TRADERS
shivrefrigeration
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .