| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC accept |
| 2 | L2₹1.5 Cr+₹5.3 L (3.67%)Rejected-AOC VILLAGE DOHAL PO PATTI TEHSIL PALAMPUR DISTRICT KANGRA | KANGRA | HIMACHAL PRADESH | 175013 | ₹1.5 Cr+₹5.3 L (3.67%) | L2 | Rejected-AOC accept |
| 3 | L3₹1.5 Cr+₹5.4 L (3.74%)Rejected-AOC | ₹1.5 Cr+₹5.4 L (3.74%) | L3 | Rejected-AOC accept |
| 4 | L4₹1.6 Cr+₹13.3 L (9.25%)Rejected-AOC | ₹1.6 Cr+₹13.3 L (9.25%) | L4 | Rejected-AOC accept |
| 5 | L5₹1.7 Cr+₹26.3 L (18.3%)Rejected-AOC VPO TEHSIL JAWALI DISTT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | ₹1.7 Cr+₹26.3 L (18.3%) | L5 | Rejected-AOC accept |
Tender Value
₹1.5 Cr
EMD Value
₹1.8 L
Closing Date
12 Jan 2022, 11:00 amClosed
EE
Jal Shakti Division Dehra
LIS Masot
2021_HPIPH_55164_1
DHR-KNG02-728
Open Tender
Civil Works
Item Rate
730 days
Dehra
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,500
₹1.8 L
Yes
21 Mar 2022
29 Dec 2021
12 Jan 2022
29 Dec 2021
12 Jan 2022
29 Dec 2021
Amount
Excavation in foundation, trenches etc. in earth work in all kinds of soil lift upto all height, stacking the excavated soil not more then 3 mtrs. clear from the edge of excavation & then returning the stacked soil in 15cm layers when required into plinth sides of foundation etc. consolidating each deposited layer by ramming & watering and then disposing of all surplus excavated earth as directed within all leads and lifts.
Pick jumper work 50% each
Providing and laying cement concrete 1:3:6(One cement :Three sand : Six graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth within all leads and lifts.
Providing and laying cement concrete 1:4:8(One cement :Four sand : Eight graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth within all leads and lifts.
Providing form work of ordinary timber plankings so as to give a rough finish including centring, shuttering, strutting and propping etc. height of propping and centring below supporting floor to ceiling not exceeding 4 mtrs.and removal of the same for in-situ-reinforced concrete and plain concrete work in:-
Foundation, footing bases of columns and the like and mass concrete within all leads and lifts .
Beams, cantilevers, girders and lintels:-Sides and soffits of beam haunching cantilever, girder, bressumers and lintels not exceeding 1 meter in depth within all leads and lifts.
Flat surfaces such as soffits of suspended floors, roofs, landing and the like within all leads and lifts.
Vertical surface such as walls (any thickness) partitions and the like including attached pillasters,buttresses, plinth and string courses and the like within all leads and lifts.
Providing and laying cement concrete 1:1:2 (One cement : one sand : two graded stone aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-.
Foundation, footing bases of columns and the like and mass concrete within all leads and lifts .
Beams, cantilevers, girders and lintels:-Sides and soffits of beam haunching cantilever, girder, bressumers and lintels not exceeding 1.00 meter in depth within all leads and lifts.
Flat surfaces such as soffits of suspended floors, roofs, landing and the like floor etc. upto 200mm in thickness within all leads and lifts.
Providing and laying cement concrete 1:2:4 (One cement : Two sand : Four graded stone aggregate 20mm nominal size and curing complete excluding cost of form work in foundation and plinth within all leads and lifts.
Providing and laying cement concrete 1:1.5:3 (One cement:one & half sand:three graded stone aggregate 20mm nominal size) and curing complete excluding the cost of form work and reinforcement for reinforced concrete work in:-.
Foundation, footing bases of columns and the like and mass concrete within all leads and lifts .
Wall (any thickness but not less than 0.10 mtrs.thickness) attached pillasters, buttresses plinth & string courses etc. from top of foundation level upto floor two level within all leads and lifts.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring, shuttering, strutting and propping etc. with wooden battons and ballies, height of propping and centring below supporting floor to ceiling not exceeding 4.00mtrs. and removal of the same for in-situ-reinforced and plain concrete work in:-
Vertical surface such as walls (any thickness) partitions and the like including attached pillasters,buttresses, plinth and string courses and the like within all leads and lifts.
Flat surfaces such as soffits of suspended floors, roofs, landing and the like floor etc. upto 200mm in thickness within all leads and lifts.
Providing in RCC work smooth finishing of the exposed surface with cement motor 1:3(One cement:Three sand) within all leads and lifts.
Providing tor steel reinforcement for RCC work including bending, binding and placing in position complete upto floor two level within all leads and lifts.
Steel work welded in built up sections, trusses & framed work including cutting, hoisting and fixing in position and applying a priming coat of red paint:- In grating, framed, guards bars, ladders,railing, brackets & similar works within all leads and lifts.
Laying in trenches GMS pipe (L/M class) tube fitting (earth work in trenches to be measured and paid for separately) complete within all leads and lifts .
i) 150mm dia (LC)
Providing & fixing of Kartar/Bir make Cast Iron sluice valve following dia Class-PN-1.0 with M.S.flange table-5 conforming to IS:14846-2000 latest with uptodate ammendments having seat pressure 10.20Kg./cm2 including nut, bolts and gasket sheet within all leads and lifts.
150mm dia
Providing & fixing of Kirloskar/Leader make Cast steel Non return valve as per BS: 1868/API-600 with M.S.flange table-5 conforming to IS:14846-2000 latest with uptodate ammendments having seat pressure 21.00Kg./cm2 including nut, bolts and gasket sheet within all leads and lifts.
200 mm dia
Constructing chamber for sluice valve, with C.I.surface box 100mm top dia,160mm bottom dia & 180mm deep(inside) with chained lid RCC top 1:2:4 mix (One cement : Two sand :Four graded stone aggregate 20mm nominal size)100mm thick foundation concrete 1:5:10 (One cement : Five sand : Ten graded stone aggregate 40mm nominal size) and in side plastering with cement mortor 1:3 (One cemet : Three sand) finished with a floating coat of neat cement including curing complete 600x600x750mm in side size with 150mm thick walls of RCC 1:2:4 )One cement:two sand : four graded stone aggregate 20mm nominal size complete with form work and reinforcement with 6mm bars at not exceeding 150mm centres both ways within all leads and lifts.
Brick work using common burnt clay building bricks (IInd class) in super structure above plinth level upto floor two level in cement mortar 1:6 (One cement: Six sand) within all leads and lifts.
15mm cement plaster in single coat on rough side of bricks/concrete /stone walls for interior plastering up to floor two level including arrises, internal rounded angles chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth cement mortar 1:3 (One cement: Three sand) within all leads and lifts.
Beam ISMB 450 for hoisting chain pully including chain pully arrangement complete in all respect.
Providing and fixing cast iron manholes cover 500mm dia (Medium duty) with frame weight not less than 116Kgs. (weight of frame 58Kgs. And weight of cover 58 Kgs. within all leads and lifts.
Providing and fixing steel bar cage for fastening of pump with piers of 300 mm dia of mesh size 50mm x 50 mm 16mm square steel bars complete in all respect.
Miscellaneous expenses for 50 m approach channel, ISMB 450, MS railing, RS Joist, Chain pully and stairs or like items required during the execution as per site condition, mathematical model studies. Protection of civil and mechanical units from flood and silt providing rough filter media etc. complete in all respet.
Providing wood work in frames of doors, windows, clearstory, windows and other frames wrought, framed and fixed in position in 2nd class deodar wood within all leads and lifts.
Providing and fixing wood paneled glazed or panelled and glazed shutters for doors windows & clear story windows including black enamelled iron butt hinges with necessary screws 40mm thick 2nd class deodar wood with in all leads and lifts.
Providing and fixing wire gauge shutters using glavanised MS wire gauge of IS gauge destination 85 G with wire of dia 0.56mm for doors, windows including bright finished black enamelled iron hinges with necessary screws 40mm thick 2nd class deodar wood (40mm thick) within all leads and lifts.
Applying two coat of wood preservative on new wood based surface after and including preparing the surface by thoroughly cleaning dirt ,dust and other foreign matter ,sand papering and knoting within all leads and lifts.
Applying a priming coat over new wood and wood based surface after and including preparing the surface by thoroughly cleaning oil dirt grease and other foreign matter sand papering and knotting ready mixed paint brushing wood primer pink within all leads and lifts.
Painting two coats (excluding priming coat) on new wood and wood based surfaces with ready mixed paint brushing to give an even shade including cleaning of all dirt, dust and other foreign matter and sand papering and stopping with ready mixed paint other than white within all leads and lifts.
White washing with lime on un-decorated walls surfaces( two coats) to give an even shade, including thoroughly brooming the surface to remove all dirt, dust mortar, dust and other foreign matter within all leads and lifts.
Finsihing wall with water proofing cement paint of approved brand and manufacture and required shade on un-decorated wall surfaces (two coats) to give an even shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials within all leads and lifts.
Providing 40x3 mm flat iron hold fast 40 cm long including fixing to frame with 10mm diameter bolts nuts and wooden plugs and embeding in cement concrete block 30x10x15cm 1:3:6 (One cement: three sand: six graded stone aggregate 20mm nominal size) within all leads and lifts.
Providing and fixing of following anodized alluminium fittings of anodized transparent and shade with necessary screws etc. within all leads and lifts.
Sliding door bolt 250x16mm.
Tower bolts ( Barrel type) 200x10mm.
Tower bolts ( Barrel type) 150x10mm
Handles 125mm.
Providing and fixing MS grills of required pattern in wooden frames of windows etc with MS flats square or round bars with rounded headed bolts and nuts or by screws within all leads and lifts.
Wiring for light point/fan point/fan point/exhaust fan point/call bell point with 1.5 Sqmm PVC insulated copper conductor cable in surface/recessed PVC conductor as required within all leads and lifts (Group -C)
Wiring for power plug with 2x4 Sq.mm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/ recessed steel conduit alongwith 1 No. 4 Sq.mm HRFRLS/PVC insulated single core copper conductor cable for earthing as required within all leads and lifts.
Wiring for circuit wiring with 2x1.5 Sqmm. PVC insulated ,copper conductor, single core cable in surface/recessed steel conduit pipe as required complete in all respect. (2x6 Sq.mm)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smole single core (flexible) copper conductor cable in surface/recessed steel conduit alongwith 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required within all leads and lifts.
2 x 6.0 Sq.mm
Supplying & fixing metal box of 180x100x60mm deep (nominal size) on surface or recessed with suitable size of phenolic laminated sheet cover in the front including providing and fixing 3 pins 15/16 Amp. socket outlet and 15/16 tumbler/piano type switch connection and painting etc.as required (for power plugs) complete in all respect.
Supplying and fixing of backellite batten/angle holder including connection as required complete in all respect.
Providing, installing, testing and commissioning of 1200mm sweep ceiling fan and regulator of Bajaj/Ysga/Khaitan/GEC/Crompton and any approved make including wiring the down rod of the standard length upto 30cm with 1.50mm Sqmm PVC insulated copper conductor single core cable etc. as required complete within all leads and lifts.
Providing, installing, testing and commissioning of prewired flourocent tube fitting 1x40 ceiling category-A Bajaj, Philips and other reputed make complete with ballast starter and capacitor suitable to operate on 230 volts single phase AC supply diretctly on surface with copper wiring as required complete in all respect.
Supplying and fixing of 40 Amps to 63 Amps rating 240 Volts "L" series miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required incluidng carriage of material within all leads and lifts Category-A, 63 Amps.
Supplying and fixing of following two way single pole and netural sheet steel MCB distribution board 240 Volts on surface/recessed completed with tinned, copper bus bar, netural link, earth bar, din bar detachable gland plate inter-connections, including painting, earthing etc. as required Bus bar 8 way complete in all respect.
Supplying & fixing or 5 to 32 Amp. rating 240 volts "G" series MCB of single pole in the existing MCBDB complete with connection, testing and commissioning etc. as required complete in all respect.
Earthing with G.I.earth pipe 4.5 Mtr. long 40mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. complete in all respect. ( but without charcoal coke and salt)
Extra for using salt and charcoal for pipe earth electrode as required within all leads and lifts.
Supplying and laying 6 Sq.mm G.I. wire at 0.50 mtr. Below ground level for conductor earth electrode including soldering etc. as required within all leads and lifts..
Providing,fixing and testing Street Light Fixture with CFL of 36 Watt, copper ballast, GI pipe bracket complete in all respect.
Providing , laying, fixing, jointing and testing in trenches GMSERW pipe of following dia meters confirming to ISO 3183-2007 (with up to date ammendments), of following grade and having wall thickness as specified below with bevelled ended and capable of withstanding required test pressure in random length of 4 to 7 meters, including specials, short pieces, bends, reducers, tees etc. made from parent tube, including the cost of jointing by way of circumfrential butt welding(94% welded and 6% flenged) conforming to IS 816-1969 or latest as applicable with up to date ammenments. The MS flanges shall be confirming to IS 6392-1971 (The cost of flange to be measurede and paid for seperately) The laying of pipe will include all operation such as cutting, welding, jointing, fabrication of bends, tees etc. including lowering and laying in excavated trenches to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the satisfaction of the Engineer in charge. The fabricated bends shall have three or four cuts having its radius not less than five times the dia of pipe. The pipes shall be factory galvanized (zinc coating both inside and outside) as per relevant IS standards. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. (Earth work in trenches be measured and paid for separately).
i) 200mm dia 4.80 mm thickness M.S flange Table-17 ( L210 or A)
i) 200mm dia 4.80 mm thickness M.S flange Table-11 ( L210 or A)
i) 200mm dia 4.80 mm thickness M.S flange Table-5 ( L210 or A)
Providing and welding M.S flanges at suitable point, conforming to following tables as per IS: 6392-1971 ( Latest with upto date amendments) with plain end GMS/MSERW pipe in requisite number of layers on both faces to make the joint leak proof ( The cost of providing and laying of MSERW pipes to be measured and paid for separately). The welding of flanges should conform to IS: 816-1969 with electrodes as per IS: 814-1991 and required number of nuts and bolts conforming to IS: 1364. including cost of gasekt sheet nuts and bolts. The thickness of gasket sheet not less than 3.00mm conforming to IS 2712-1998. The work shall be done to the entire satisfaction of Engineer-in-Charge within all leads and lifts.
i) 200mm dia 4.80 mm thickness M.S flange Table-17
ii) 200mm dia 4.80 mm thickness M.S flange Table-11
iii) 200mm dia 4.80 mm thickness M.S flange Table-5
Providing circumferential butt welding joints by electrodes arc welding to GMS/GMSERW pipe, welded in requisite number of weld runs so as to achieve the minimum effective throat thickness of weld conforming to IS: 816-1969 specifications, by using welding electrodes conforming to IS: 814-1991, at site of work complete in all respect including manual/mechanical handling of pipes in all leads and lfits to the entire satisfaction of Engineer-in-Charge.
i) 200mm dia
Laying and jointing of HDPE pipe of grade PE 63 following dia and pressure complete in all respect incluidng all fittings and accessories complete in all respect.
110mm dia (OD) 4.00Kg/Sq.cm
125mm dia (OD) 4.00Kg/Sq.cm
140mm dia (OD) 4.00Kg/Sq.cm
160mm dia (OD) 4.00Kg/Sq.cm
Laying and jointing of HDPE pipe of grade PE 63 class PN 4 following dia provided at each outlet for sprinkler/flood irrigation with average 02 tee with plugging arrangement and pipe @ 100 meter per hectare complete in all respect incluidng all fittings and accessories complete in all respect.
50mm dia
Providing and fixing tee and reducer with flange of PN 4.0, PE 63 provided at each outlet complete in all respect.
Providing and fixing Alfa valves of reputed and approved make like Kirloskar/Leader/Bouge etc. on distribution system of confirming to IS: 780-1984 with latest ammendments of appropriate class, diameter and capable to withstand the requisite nominal seat pressure 10 Kg/Sqm incluidng testing complete in all respect.
110mm dia
125mm dia
140mm dia
160mm dia
C/o RCC outlet Chamber of size 0.90mx0.90mx1.20m complete in all respect.
Providing and fixing V-notch complete in all respect.
Fabrication, providing and fixing of MS screen for supply of clean water in distribution complete in all respect.
Submersible Pumping Machinery Booster stage including automation :- Supply of submersible pumping set of Kirloskar/ Kilburn/ Clama/ Crompton/KSB/BS make conforming to BIS; 8034-1976 latest suitable for lifting Raw water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head =28.06 mtr.
Discharge required from each pum = 15.16 LPS
No. of pump required = 2.00 Nos .
Location of the site of inatallation of machinery = the site is located at a distance of 30.00 kmts from Ranital Railway station by road & 0.500 KM on head load ( for the installation of both machineries.
The Altitude of installation. The altitude of place is 420.00 mtrs above MSL,Type of current. AC Three phase supply with, Rate Voltage Rate Voltage 415+ 10%,Type of water and its source Raw water from Beas River,Charactristics of water. Ambient Temperature dig.c 20 dig. C,b)Turbidity NTU/PPM 3000 PPM, c)Hardness 260Mg/Ltrs(as CaCO3) = -,d) PH -- ,e)total solid Mg /Ltrs = -,f)Other = -,Depth of Sump well/ check dam ---- mtr., LWL in sump well ----, Center line level of pump = 420.00 mtr.,Discharge level of highest point = --- ,Static head in Mrs = 25.00mtrs.,Length of R/Main = 100 mtr.,Dia of Rising main = 200MM dia No of working hours per day = 20.00 Hours,Limit of pump operation. = (-) 15 % (+) 10% of total head,R.P.M. of pumping set.= 2900 RPM ( or to be specified by the tenderer)Test run.= 8 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating 12.50 HP automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES
Variable frequency drive starter of 12.50 HP Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES = 2 No
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens = 1 No.
MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release. = 1 No.
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments. = 2 No.
Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB = 2 No.
On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. = 1 No.
Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal = 1 No.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. = 1 No.
Output contactors in the output of VFD to run the pump = 2 No.
Transporatation and Carrage Charges for panel till site = 1 No.
Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta = 1 No.
HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon. = 1 No.
Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users=1 No
Level Sensor to indicate the water level of tank remotely= 1 No
Cloud GateWay for Data Cluding to Server = 1 No.
Cable for Communication for Water Level Sensor = 1 No.
Installation and Commissioning (scada based) = 1 No.
Supply of fixing of doble flanged acctuator cast iron sluice valve heavy size one dia higher tha pump size to delivery of pump class PN 1.0 of Kirloskar/Kilburn/Leader make conforming to BIS 14846-2000 laest with up to date ammendments having seat pressure of 10.20kg/cm2 complete in all respect. (200mm dia)
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged accuator swing check type reflux valve class ASA-150 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat presure of 16 Kg/Cm2 as per BIS 5312-1984 Part-I
Supply of Kirloskar/ Kilburn/Leader make Cast iron class ASA-150 double flanged acctuator swing check type reflux valve having bypass arrangement equal to dia of Risng main i.e. 300mm shall be suitable for withstanding nominal seat pressure of 16 Kg/Cm2 as per BIS 5312-1984 ( Latest edition)
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 16.00 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 10.00 mm^2 ( From Switch & Starter to Motor) pump installed in the check dam.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to 15 BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer).
Supply of standarad make 100 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe 200 mm dia ( To be specified by the tenderer)
Delivery pipe 200 mm dia ( To be specified by the tenderer)
Common header = 200 mm dia
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Centrifugal Pumping machinery collection tank to delivery tank Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB/Mather & Platt/Jyoti/Kirloskar/BE/Maxflow/Beaconweir/Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC( Marrathon) /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.
Total Head= 122.03 Mtrs. Discharge required from each pump = 15.16 lps of each pump No. of pump required 2.00 set ( one will act as stand by) Location of the site of installation of machinery = the site is located as a distance of 30 Km from Ranital Railway station and 0.500 KM on head load ( for the installation of both machineries) The altitude of installation = 420 MSL Type of current AC three phase supply with freqduency of 75 cycle per second. Rate Voltage 415+ 10%, Type of water and its source Raw water from Beas River , shaft level = 445 mtr. , level of discharge poine = 553.35, Static head = 100.00 Charactristics of water. Ambient Temperature dig.= 20 degree b)Turbidity NTU = 115 NTU, c) Hardness 260Mg/Ltrs(as CaCO3) = -,d) PH - 6 to 8,e)total solid Mg /Ltrs = -,f)Other = -,Depth of well assembly -- No of working hours per day = 20.00 Hours, length of Rising main = 2000 Rmt. Dia of Rising main = 200 mm Limit of pump operation. in the completem Range of = (-) 15% R.P.M. of pumping set.= 2900 RPM Test run.= 8 Hours continueously for 7 days
Supply , Installation, Testing and Commissioning of Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump of rating automatically through Variable Frequency Drive Starter. Starter should be capable to handle all the faults like short circuit, over current, under current, over voltage, under voltage, dry pump protection. It should get on and off command automatically from PLC and HMI. Monitoring and controlling of Pump running and tripping status should be monitored and controlled remotely through IOT enabled device. Access should be given to 3 users. Make: Aarmation Electric Private Limited/MAS/ELLES
Variable frequency drive starter of Heavy Duty for smooth start and smooth stop of pumps and for the energy conservation in the system. It Should be capable to control the frequecy of pumps through out the operation and also should be capable to maintain the power factor of the system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3C2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/MAS/ELLES = 2 No
Multi function meter indicating different parameters like Current, Voltage, KWH, PF, THD etc with RS 485 communication Make L&T/Conserve/Siemens = 1 No.
MCB /MCCB suitable capacity of L&T / Standard make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release. = 1 No.
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments. = 2 No.
Incommer MCCB with for proper short circuit capability for both the starters make L&T/Schnieder/ABB = 2 No.
On / Off indicator and push button, Control and power wiring,Power capacitor,Cooling fan 230 VAC, Contorl terminal, Buss Bar, i.e.Bolt, insulator, etc. = 1 No.
Input Choke which should be installed at the input of VFD starter, so that there should be proper protection in case of any voltage surge and distortions in signal = 1 No.
Control Transformer to safegaurd the control circuit of all the components from the voltage surges and spikes. = 1 No.
Output contactors in the output of VFD to run the pump = 2 No.
Transporatation and Carrage Charges for panel till site = 1 No.
Programmable logic controller with appropriate digital and analog inputs and outputs to give automatic command to star delta and also will get data from Multi function Meter for Current, Voltage, KWH, PF and THD. Make Mitsubishi/L&T/Delta = 1 No.
HMI 7" display with IOT to give on and off command manually and also to show pump running and breakdown status at pump station Make Wientek/Exor/Mitsubishi/Mecon. = 1 No.
Supply of software with license to monitor data at Laptop/Mobile in form of Software and Mobile Application for 3 users = 1 No
Level Sensor to indicate the water level of tank remotely = 1 No
Cloud GateWay for Data Cluding to Server = 1 No.
Cable for Communication for Water Level Sensor = 1 No.
Installation and Commissioning ( SCADA BASED) = 1 No
Supply of Kirloskar/ Kilburn/Leader make Cast iron double flanged swing check type reflux valve class PN 1.6 having bye pass arrangement ( to be provided on delivery side) of size of one size higher than the delivery size of pump and shall be suitable for withstanding nominal seat presure of 16.32 Kg/Cm2 as per BIS 1868-API-600
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 50mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 32 mm^2 ( From Switch & Starter to Motor)
Supply of standarad make 200 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe 200 mm dia
Delivery pipe 200 mm dia
Common header = 200 mm dia
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries)
Errection of all equipments including cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
GANTANTAR THAKUR
Raman Kumar JAswal
Sanjeev
Sushant Puri
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .