| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹35.2 L+₹1.3 L (3.97%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹35.5 L+₹1.6 L (4.65%)Rejected-Finance 22 JANKALYAN SOCIETY NAVJIVAN AJWA ROAD BARODA 390 019 | BARODA | VADODARA | GUJARAT | 390019 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹36.7 L+₹2.8 L (8.28%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹36.7 L+₹2.9 L (8.46%)Rejected-Finance 160 PREM NAGAR BAREILLY | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
23 Feb 2021, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO CWE / HILLS /RKT /68 OF 2020-21 SPECIAL REPAIR TO OTM BLDG NO T-191, T-203, T-280, 1/5115, 9/5115, 26/5115 AND 52/5115 AT MIL STN HALDWANI UNDER GE RANIKHET
2021_MES_414919_1
CA No CWE/HILLS/RKT/68 of 2020-21
Open Tender
Civil Works
Works
150 days
RANIKHET
CLASS D
10 documents required · 10 mandatory
₹500
GE RANIKHET
₹77,800
Yes
23 Mar 2021
21 Jan 2021
25 Feb 2021
21 Jan 2021
23 Feb 2021
10 Feb 2021
21 Jan 2021 - 7 Feb 2021
Amount
Demolition of brick work in cement mortar including all quoins, arches, pillars etc, but excluding ashler facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of cement concrete as in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Dismantling of Ppain or corrugated steel sheeting, any gauge and thickness complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) any thickness, including cover fillets but without frame work complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed.
Dismantling of wrought iron or mild steel work any description and fixed in any position complete all as specified and directed.
Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc complete as directed and specified.
Taking down Chowkhats or frames n exc 1.5 sqm each (without taking off shutters from frames) complete all as specified and directed.
Taking down Chowkhats or frames exc 1.5 sqm but n exc 4 sqm each (without taking off shutters) complete all as specified and directed.
Taking down shutter of any description exc. 1.0 Sqm but n.exc 2.0 Sqm each complete all as specified and directed.
Taking down shutter of any description n exc. 1.0 Sqm each complete all as specified and directed.
Taking down of existing aluminium door of any description including renewal of unserviceable parts and refixing in the same opening complete all as directed.
Taking down 15 mm bore steel tubing and connections including cleaning for refixing complete all as specified and directed.
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed.
Shoring and strutting timbers complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
M&L for brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 complete all as specified and directed.
M&L for cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required, depth of holdfasts exc half brick but n exc one brick complete all as specified and directed.
M&L for precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in cover slabs (for manholes etc) shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 including necessary form work complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20mm grade stone aggregate) as in cills, steps seismic and other similar bands, plinth courses, coping, parapets and railings slightly rounded or charfered complete all as specified and directed.
M&L for 2nd class hard wood plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
M&L for 2nd class hard wood in scatling , clean swan,including to replace old and decayed timber (including piecing, scarfing, etc., of old and new timbers if required) complete all as specified.
M&L for 2nd class hard wood in scantling fixed clean swan complete all as specified and directed.
M&L for second class hard wood in scantling fixed wrought complete all as specified and directed.
S&F 35 mm thick IInd class hardwood, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
S&F 35mm thick Glazed and skeleton shutters in 2nd class hardwood, open rebated and prepared to receive glass, gauze, etc. (without sash bars) edges of forming plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 200mm long, aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm long, aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F of 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
S&F 100 mm long, butt hinges medium weight cold rolled complete all as specified and directed
S&F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
S&F of 75mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed.
S&F in repair hasp and staple, 150mm long safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
M&L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass,other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
S&F in repair galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified including applying evenly a tack coat of industrial bitumen 58/25 at the rate of 1.2 kg/Sqm including cleaning surfaces complete all as specified and directed.
M&L for PCC 1:2:4, type B-1 (using 20 mm grade stone aggregae) in roof paddings, kerbs and the like complete all as specified and directed.
M&L for 4mm thick non asbestos fibre cement building boards for insulation and accoustic purposes,60 X60 cm in size , fixed with screw to timber frame work or staples on snap grid as in ceiling complete all as specified and directed.
S&F anodised aluminium snap grid frame of size 605 x 605 mm as in false ceiling complete all as specified and directed.
S&F 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dipped galvanished with high durable protective triple coated self tapping screws /self drilling serews, to suit the roofing in customized colour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified and directed.
S&F 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with hot dipped galvanished with high durable protective triple coated self tapping screws /self drilling serews, to suit the roofing in customized colour matching with the colour of roofing and screws are to be fixed using torque adjustable electronic gun screws drills of suitable capacity complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6, type C-2 (using 40 mm grade stone aggregate) alloy in plinth protection including finishing even and smooth without using extra cement complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out glazing pins/spring clip and providing and fixing new ones complete all as specified and directed.
S&F 4.0 mm thick sheet glass, ordinary quality and glazing with oil putty in squares exceeding 0.5Sqm in each pane complete all as specified and directed.
S&F 3.0 mm thick, sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sqm in each pane complete all as specified and directed.
S&F 3.0 mm thick figured glass, pin headed type and glazing with oil putty in square n. exc 0.5 sqm in each pane complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats oil bound distemper over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats cement base paint complete all as specified and directed.
Preparation of old / newly plastered surfaces of wall and applying wall care putty of not less than 3mm thick complete to true surfaces for receiving wall finishes complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying two coats of oil bound distemper over a coat of primer with alkali resistant complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel surfaces any description, over 10cm in width or girth,not otherwise applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of old steel surfaces of any description over 10cm width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description and applying two coat of french polish including a coat of wood filler on new works with two or more coats complete all as specified and directed.
S&F hand rails, half round or other stock section or core for wooden hand rail straight portion, wind ties for roof cut tops to shape as directed, drilling holes, riveting securing bolts washers etc and simillar works conforming to Fe-290, Gde-E-165 complete all as specified and directed.
S&F mild steel flat iron for hold fast and simillar works conforming to Fe-290, Gde-E-165 complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape requred, including cranking, binding spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F plates (plain or chequered) channels, sqaure cut or notched forming holes with or without attachments Fe-290 (Gde E-165) complete all as specified and directed.
S&F rolled sections as in main and cross beams, hip and jack rafters; purlins, posts where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde -E-250) Quality A complete all as specified and directed.
M&L for 15mm thick cement plaster in CM 1:4 on fair faces of brick or concrete surfaces using WPC where ever required as per manufacturerer's instructions and finishing the surface even and smooth without using extra cement complete all as specified and directed. NOTE -WPC shall be measured and paid separetely.
M&L for rendering 15mm thick on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral waterpoofing compound complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation and mass concrete complete all as specified and directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for machine pressed precast cement concrete interlocking paver block any shape and size 60 mm thick with grey cement and pigments confirming to IS 15658-2008 of M-35 complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in floors /sub base complete all as specified and directed.
M&L for screed bed or bedding Layer 15mm thick in cement mortar 1:6 for laying floor finishes/ tiles complete all as specified and as directed.
M&L rendering 10mm thick in cement mortar 1:4 on brick work or concrete surfaces to receive tiles complete all as specified and directed.
M&L for light shade virtified ceramic tiles 600mm x 600mm x 10 mm size on floor set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
M&L for light shade virtified ceramic tiles 600mm x 150mm x 10 mm size on vertical surface as skirting set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
S&F coloured non skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
S&F coloured glazed ceramic tiles in vertical surface 450 x 350 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to matchcomplete all as specified and as directed.
M&L for kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar including 10mm thick plaster in cement mortar 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L grinding and polishing to existing kota stone complete all as specified and directed.
S&F fillets square rectangular or trianguler in section clean sawn secured with nails 2nd class hard wood sectional area exc 13 but n exc 25 sqcm complete all as specified and directed.
M&L for 18/19 mm thick pre laminated particle board interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber framework complete all as specified and directed.
M&L in repair 12mm thick veneered decorative plywood , grade-1 ( with BWR resin ) with decorative face venners on both faces; fixed with screws to timber frame work complete all as specified and directed.
S&F 30mm width of flaps (when opene) continuous (piano) hinges, mild steel, bright finish or electrogalvanised complete all as specified and directed.
M&L for 12mm wide external teak wood lipping , 6mm thick fixed with nails complete all as specified and directed.
S&F 15 mm bore bib taps standard of PTMT any colour hingh pressure screwed for iron pipe and fixed minium wt 90gms complete all as specified and directed.
S&F Vitreous China wash down water closet pan (pedestal pattern), white/coloured (including fixing bolts & flush pipe, plastic water closet seat,black, closed pattern with bottom, and cover and mild steel chromium plated or aluminised hinging device etc.) complete all as specified and directed.
S&F PVC flushing cistern 10 litre capacity, low level valve less, symphonic action type, white, with Inlet, ball valve, float and handle including 32mm dia PVC flush pipe, a pair of MS brackets,CP flush bend including cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 including taking down unserviceable flushing cistern and connected Items of any description complete all as specified and as directed.
S&F tubular towel rail CP brass, 20 mm dia chromium plated D type with CP brackets, 600 mm long between flanges complete all as specified and directed.
S&F in repair vitreous china urinal, half stall type,white complete including flush pipe and waste pipe fixed omplete bedding urinal against wall in CM 1:2 including brass screws pointing around urinal complete all as specified and directed.
S&F in repair vitreous china wash basin, white, flat back, size 550mm x 400mm, including brackets, PVC waste pipe 32mm dia, waste coupling brass, chromium plated and including cutting for and pinning in ends of brackets or erecting stand, fixed complete all as specified and directed.
S&F in repair 15 mm dia, fancy type, pillar tap, cast copper alloy, with capstan heads, with chromium plated, screwed down high pressure with or without lettered 'hot' or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F of 15 mm bore steel water tubing medium grade galvanised with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S&F in repair 15 mm dia angle cock, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair 15 mm bore bib taps, chromium plated fancy type long body cast copper alloy crutch or butter fly handle, screwed down, screwed down,screwed for iron pipe or for brass ferrule with flange fixed complete all as specified and directed.
S&F in repair 15 mm bore PVC connections with PTMT Nuts of length 600mm long complete all as specified and directed.
S&F brass chromium plated shower rose 125mm size with swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed.
S&F decorative MS PVC coated tubular curtain rail of wooden finish of 40mm dia including six nos curtain ring per running mtr and one number of brackets on each end and one no of globe on each end of the rod per opening of door / window complete all as specified and directed.
Surface excavation n exc 30 cm deep and average 15 cm deep and getting out in soft/disintegrated rock complete all as specified and directed.
M&L for PCC (1:4:8 ) type D-2 as in sub base finished even and rough 75mm thick complete all as specified and directed.
Taking down existing wash hand basin and providing angle iron brakets including necessary nut and bolts & necessary welding for fixing of WHB including securing and fixing complete all as specified and directed.
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc complete all as specified and directed.
S&F for door closer aluminium extruded section hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and directed.
S&F powder coated aluminium windows and ventilator shutters,sliding or fixed type without sash bars , aluminium section weighting 0.55 kg / m including necessary joining cleats , glazing clips ,roller, rubber packing, anodised aluminium snap beading , screws,anodised aluminium fitting such as peg stays hinges,handle,locking device, louvers, rollers etc. complete all as specified. (Note:- Glass pane and mesh will be measured and paid separately )
Taking down carefully aluminium/copper wiring of any size (for light, fan, socket or power etc complete) (fittings such as switches, sockets, ceiling roses, pendent holders regulators, tube lights etc to be measured and paid separately) and making good disturbed surfaces of wall, roof etc to match with existing surface complete all as specified and directed.
Taking down carefully by unscrewing from the boards/outlets boxes fittings and fixtures such as switches, sockets ceiling, rose, lamp holders, tube light fittings, regulators etc and making good of disturbed surfaces complete all as specified and directed.
Taking down unserviceable main switches MCB DB’s incl MCB SP/DP/SPN of any make and type including teakwood board etc complete and making good the disturbed surfaces including colour wash complete all as specified and directed.
Taking down carefully sub main wiring complete with conductor, cast conductor and PVC casing and coping and make good to the disturbed surfaces complete all as specified and directed.
M&L for point wiring for one light point/ fan/ bell (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including PVC casing/capping and accessories including sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge)
All as per item No.111 herein before but one socket outlet 5 Amps on the same board.
All as per item No.111 herein before but one switch socket combination 5 Amps on independent board
All as per item No 111 herein before but wiring with 2.5 sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board.
M&L for point wiring for one light point/ fan/ bell (independent) point controlled by one, one way switch with 1.5Sqmm size, PVC insulated and unsheathed 1100volts grade, single core stranded (multistrand) copper conductor (FRLS) PVC cable drawn into & including medium grade PVC conduit (not less than 20mm outer dia ) with all fittings and accessories fixed concealed (including chase cutting in brick/ stone masonry walls for fixing conduit and plastering and whitewash/colouring the external surface and matching the same with existing surface), fixing on wall by using saddles, screw ect and sunk cast iron or pressed steel terminal boxes for mounting fittings like switches, sockets & fan regulators etc with 3 mm thick plastic laminated sheet covers fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.5 Sqmm multistranded copper conductor cable earth wire and connected to earth dolly complete all as specified and directed (Note:- wiring shall be done in colour coding as directed by Engineer in charge)
All as per item No. 115 herein before but one socket outlet 5 Amps on the same board.
All as per item No. 115 herein before but one socket outlet 5 Amps on independent board
All as per item No 115 herein before but wiring with 4 sqmm copper wire (FRLS) PVC and 2.5 sqmm earth wire for socket outlet 5 pin 15 amps on independent board.
S&F switch piano flush type single pole, one way 5 Amp complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 Amp, flush type universal complete all as specified and directed.
S&F ceiling rose, PVC/ polycarbonate, isolated body three terminal complete all as specified and directed.
S&F lamp holder PVC insulated body with back plate for angle/battern fitting complete all as specified and directed
S&F 150 watt steped type electronic fan regulator flush type on the existing phenolic laminated sheet etc complete all as specified and directed.
S&F isolator TPN 415 Volts, 50 Hz, 100 Amps complete all as specified and directed.
S&F isolator Four pole 415 Volts, 50 Hz, 63 Amps, 10 KA complete all as specified and directed.
S&F isolator four pole 240 Volts, 50 Hz, 40 Amps, 10 KA complete all as specified and directed .
S&F isolator DP 240 Volts, 50 Hz, 40 Amps, 10 KA complete all as specified and directed.
S&F isolator DP 240 Volts, 50 Hz, 63 Amps, 10 KA complete all as specified and directed.
S&F isolator SP 05-40 Amps, 10 KA complete all as specified and directed.
S&F sheet metal enclosure for DBs(double door type) single pole and neutral 4 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed.
S&F sheet metal enclosure for DBs(double door type) single pole and neutral 8 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed.
S&F sheet metal enclosure for DBs(double door type) single pole and neutral 12 way including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed complete all as specified and directed.
S&F sheet metal enclosure for DBs (double door) TPN 4 way with 415 V 200 Amps rated bus bar fixed complete all as specified and directed.
S&F Metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 6-32 amps complete all as specified and directed.
M&L in replacement of 250 Amps MCCB 4 pole 415 V adjustable with breaking capacity of 36 KA complete all as speicified and directed.
M&L for sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to and including Rigid non metallic PVC conduit ( ISI marked) Heavy grade, 20 mm dia (external) inclusive of junction/terminal boxes, all fittings and accessories fixed concealed with and including 2.5Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB including cutting and chasing and making good surface as original by plastering and whitewash/ colour/ distemper etc including taking down existing old sub main wiring complete all as specified. Note :1 The cost of earth wire is included in the quoated rates. 2. Two run of 4 sqmm, one run of 2.5 sqmm and one run of PVC conduit will be measured as one unit ie one running metre”
M&L for sub main wiring with 2 single core PVC FRLS insulated, unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6 Sqmm drawn through rigid PVC heavy grade concealed conduits incluidng 4 Sqmm PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified, directed and shown on drgs. (Note :- Two runs of cables and continuous earthwire in conduit will be measured as one length of sub main.)
Taking down carefully existing study lamp on wall of bldg and refixing the same fittings at the same location after completion of wiring/repair works complete all as specified and directed.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, cross section area 25 Sqmm 2 core laid in trenches or passing through pipes/ducts and incl the disturbence surface of road making good with using PCC complete all as specified and directed.
Excavating in trenchs, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/ dense soil complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) n exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L for dry clean sand filling in trenches below and around under ground cable cushioning complete all as specified and directed. Note :- Thickness of sand cushioning shall be measured after punning.
M&L for brick sub class 'B' for protection of cable complete all as specified and directed.
S&F steel tube medium grade galvanised 25 mm bore with all fittings for protection of UG cable under road/culvert and fixing on wall with saddle, screw complete all as specified and directed.
Supply, laying, connecting, testing and commissioning sevice cable of 10 Sqmm 2 Core, stranded conductor , PVC insulated screened, PVC bedded, heavy duty electric cable with solid aluminium conductor 1100 Volts, fixed to walls/ air with suitable GI wire for tightening/support to cable complete all as specified and directed.
M&L for taking down ceiling fans / wall mounted fans of any size / sweep after disconnecting the wire from existing ceiling rose and refixing the same after painting the same with synthetic enamel paint by spray machine including filter after cleaning dust, taking out burnt/damaged winding, bushes & cleanig of stator and rotor incl etc. Rewinding with 26/27 SWG of enamelled copper winding wire replacement of bearing /bushes, condencer 2.5/4 mfd handing and testing of fan with and including provision of 23/0.0076 copper flexible core twin core not less than 1.5 meter in length and make the fan operational with a guarantee period of one year after installing the repair fan complete all as specified and directed.
S&F landscaping wall light sun/ prismatic made up of unbreakable carbonate, suitable on wall/ surface mounting lamp holder with 12w LED lamp complete all accessories and fitiing complete all as specified and directed.
S&F 5 Watt LED mirror light complete all accessories and fitiing complete all as specified and directed.
Supplying, fixing ,testing and commissioning of pre-wired 36 watt LED light fitting of approved make, complete with CRCA housing,replaceable driver, high quality difuser etc, all as specified and as directed. The rates shall include all fixing accessories that are required to make the installation complete in all respects including the required GI flexible conduit with wiring from true ceiling to false ceiling for fixtures recessed in false ceiling,providing connecting wires and channel support wherever required,Internal wiring between accessories,Self interlocking connector blocks for connecting the wires from fixtures to the points, earthing of fixtures with 1.5 sqmm FRLS PVC insulated copper conductor wire, and other components and fixing accessories wherever required complete all as specified and directed.
S&F universal batten for T8 LED tube suitable for retrofit lamps complete all as specified and directed.
S&F ultra bright LED polycarbonate tubelight with very high efficacy suitable for installation in existing T8 fitting with G13 lamp holders complete all as specified and directed.
S&F 10W bulk head light PDC aluminium housing with polycarbonate diffuser, SMD LED and heat sink integrated with housing complete all as specified and directed.
Shri Siddhi Vinayak Constructions
aditya construction
kumar automobiles
Builders Harpal
URBANS CONSTRUCTIONS
YASH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .