Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹70.2 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | ARGOS ARKAYA POWER SOLUTIONS LLP L1 |
|---|---|---|---|---|
| 1.00 | Supply of SMD 500W LED Floodlight fixture with System efficacy of 130 lm/W or more . Luminaire shall be made up of Aluminium Extrusion housing with PC/Borosilicate glass lens. Luminaire should be moduler. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Manlux/ Osram/Seoul should be provided and high Power LED of 3W to 5W should be used. LED must be of ceramic base type. Luminaire shall be with IP66 and IK5 protection. Luminaire must be available with beam angle of 10/15/45Deg. The LED shall be compliant with LM80-08 standard with L70 life of 50,000 Hrs tested at maximum current +/-10% tolerance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. Driver will be potted type, Integral / Non Integral type Constant Current operated driver with range 100-305V AC. Driver Efficiency > 90% & 4KV internal surge protection with additional 10KV SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Operating temperature range: -10deg C to +45deg C +/-10% tolerance. Driver shall provide ultra low ripple current of < 3%. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; EN IEC 55015:2019; ENIEC 61000-3-2:2019; EN 61003-3-3:2013; EN 61547:2009, EN 61347-2-13:2014; EN IEC:62384/IS:16104 | 56 | Nos | 37,561 ₹21,03,416 Lowest |
| 2.00 | Supply of 12M (Top of headframe) fixed head frame stadium High Mast with close (Monkey) Ladder complete with all accessories, designed for mounting up to 14 nos. X 500W LED floodlights and the wind loading as per IS 875 (Part III) for Delhi, with recommended safety factors. Supply of Foundation bolt sets for above High Masts complete with anchor plates and template. Unloading, Shifting, stress fitting, mounting of head frame and other accessories and installation thereof on existing foundations with suitable capacity main and auxiliary crane, adhering to all safety protocols. Proper alignment, orientation and levelling of High Mast is an integral part of this activity | 4 | Nos | 3,28,660 ₹13,14,640 Lowest |
| 3.00 | High Masts Foundations - Design and construction of open raft type foundation for High Masts with 'M25' grade concrete and High grade steel reinforcement. The foundation shall be designed as per the safe soil bearing capacity at the location, considering the bending moments and other forces expected to be transferred on to the foundation. Fixing of foundation bolt assembly and provision of HDPE pipes for copper flexible cables is an integral part of this work and includes all material, labour and T&P, shuttering and curing, etc. This item includes back-filling, compacting of soil, removal of surplus earth and restoration, as applicable | 4 | Job | 56,342 ₹2,25,368 Lowest |
| 4.00 | Aviation obstruction Light
SITC of Low intensity LED type aviation obstruction luminaries on high masts. | 8 | Nos | 6,198 ₹49,584 Lowest |
| 5.00Earthing | ||||
| 6.00 | Earthing with G.I. earth plate including accessories, and providing masonry enclosure with cover plate having locking arrangement and with charcoal/ coke and salt as required. | 8 | Set | 37,561 ₹3,00,488 Lowest |
| 7.00Control Panel | ||||
| 8.00Supplying, erecting, testing and commissioning outdoor duty floor mounted weather proof IP65 feeder pillar with lockable outer door) and sloping roof. | ||||
| 9.00Master Control Panel | ||||
| 10.00 | 1 No 200A TPN MCCB
1 no 96mm x 96mm multi parameter digital meter with LCD display for voltage & current with suitably rated CTs and MCB protection.
1 set of three phase indicating lamps with suitable protection. | 1 | Set | 71,784 ₹71,784 Lowest |
Tender Value
₹52.0 L
EMD Value
₹1.0 L
Closing Date
9 Jan 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer DRDA Senapati.
Office of the EE DRDA Senapati
Installation of Flood Lighting System in Senapati Public Turf Ground, Senapati DHQ.
2025_RDnPR_3115_1
No.12/DRDA(SPT)/SPA/FL/2025.
Open Tender
Electrical Works
Works
As Per Tender Document
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,000
Acc No - 30396437886
₹1.0 L
29 Jan 2026
20 Dec 2025
12 Jan 2026
20 Dec 2025
9 Jan 2026
20 Dec 2025
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Executive Engineer DRDA Senapati.
Name of Work: Installation of Flood Lighting System in Senapati Public Turf Ground, Senapati DHQ
Contract No: 12/DRDA(SPT)/SPA/FL/2025.
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT With Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 Supply of SMD 500W LED Floodlight fixture with System efficacy of 130 lm/W or more . Luminaire shall be made up of Aluminium Extrusion housing with PC/Borosilicate glass lens. Luminaire should be moduler. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Manlux/ Osram/Seoul should be provided and high Power LED of 3W to 5W should be used. LED must be of ceramic base type. Luminaire shall be with IP66 and IK5 protection. Luminaire must be available with beam angle of 10/15/45Deg. The LED shall be compliant with LM80-08 standard with L70 life of 50,000 Hrs tested at maximum current +/-10% tolerance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. Driver will be potted type, Integral / Non Integral type Constant Current operated driver with range 100-305V AC. Driver Efficiency > 90% & 4KV internal surge protection with additional 10KV SPD, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Operating temperature range: -10deg C to +45deg C +/-10% tolerance. Driver shall provide ultra low ripple current of < 3%. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967; EN IEC 55015:2019; ENIEC 61000-3-2:2019; EN 61003-3-3:2013; EN 61547:2009, EN 61347-2-13:2014; EN IEC:62384/IS:16104 1 56 Nos 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
2 Supply of 12M (Top of headframe) fixed head frame stadium High Mast with close (Monkey) Ladder complete with all accessories, designed for mounting up to 14 nos. X 500W LED floodlights and the wind loading as per IS 875 (Part III) for Delhi, with recommended safety factors. Supply of Foundation bolt sets for above High Masts complete with anchor plates and template. Unloading, Shifting, stress fitting, mounting of head frame and other accessories and installation thereof on existing foundations with suitable capacity main and auxiliary crane, adhering to all safety protocols. Proper alignment, orientation and levelling of High Mast is an integral part of this activity 2 4 Nos 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
3 High Masts Foundations - Design and construction of open raft type foundation for High Masts with 'M25' grade concrete and High grade steel reinforcement. The foundation shall be designed as per the safe soil bearing capacity at the location, considering the bending moments and other forces expected to be transferred on to the foundation. Fixing of foundation bolt assembly and provision of HDPE pipes for copper flexible cables is an integral part of this work and includes all material, labour and T&P, shuttering and curing, etc. This item includes back-filling, compacting of soil, removal of surplus earth and restoration, as applicable 3 4 Job 1 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
4 Aviation obstruction Light SITC of Low intensity LED type aviation obstruction luminaries on high masts. 4 8 Nos 1 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
5 Earthing 5 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
6 Earthing with G.I. earth plate including accessories, and providing masonry enclosure with cover plate having locking arrangement and with charcoal/ coke and salt as required. 6 8 Set 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
7 Control Panel 7 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
8 Supplying, erecting, testing and commissioning outdoor duty floor mounted weather proof IP65 feeder pillar with lockable outer door) and sloping roof. 8 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
9 Master Control Panel 9 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
10 1 No 200A TPN MCCB 1 no 96mm x 96mm multi parameter digital meter with LCD display for voltage & current with suitably rated CTs and MCB protection. 1 set of three phase indicating lamps with suitable protection. 10 1 Set 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
11 Pole Control Panel 11 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
12 1 no. 40A TPN MCB 15 nos.10A/16A/32A SP MCB other accessories 12 4 Set 1 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
13 Cables 13 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
14 Supply of 4C - 6 Sq.mm, Aluminium Armoured Power Cable of 500 Meter for connection between the Master Control Panel to Pole Control Panel and Laying of Cable 14 500 Meter 1 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
15 Laying of aluminium armoured power cable of 1.1 KV grade as given in 7.1 direct in ground including excavation, sand cushioning, and refilling the trench etc as required. 15 500 Meter 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
16 Supply of 3C - 2.5 Sq.mm, Copper Cables for Connecting from Pole Control Panel to the Luminaries 16 1000 Meter 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
17 Laying and connection of unarmoured Copper Control cable, PVC insulated, as mentioned in 7.2 17 1000 Meter 1 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
18 Generator (50 kva CPCB IV+ three phase silent DG set conforming relevant to IS) 18 1 Nos 1 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
19 Installation, testing and Commissioning of poles with 19 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
20 1. Erection of poles 2. Installation of Lights on the poles 3. Adjustment of Lights 4. Control Panel Installation 5. Testing 6. Commissioning 20 4 Job 1 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
stage.html
html • 0.03 MB
techsummary_3393.pdf
BOQ Comparative Chart
xlsx
cancelled_1.pdf
pdf • 0.26 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.54 MB
BOQ_3393.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .