| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 CrAccepted-AOC | ₹3.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹3.1 CrRejected-AOC BANKERS VILLA VAZHOTTUKONAM VATTIYOORKKAVU P O TRIVANDRUM 695 013 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695013 | ₹3.1 Cr | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Bankers Construction L2 | CIVILCO ENGINEERING P LTD L1 |
|---|---|---|---|---|---|
| 0.00CIVIL WORKS | |||||
| 1.00DISMANTLING AND DEMOLITION | |||||
| 1.01 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge | 8 | Nos | 140 ₹1,120 | 138.85 ₹1,110.80 |
| 1.02 | Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead | 8 | each | 930 ₹7,440 | 933.75 ₹7,470 |
| 1.03 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above | 3.27 | cum | 4,625 ₹15,105.25 | 4,607.85 ₹15,049.24 |
| 1.04 | Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below | 59 | each | 150 ₹8,850 | 148.31 ₹8,750.29 |
| 1.05 | Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge | 302.18 | sqm | 60 ₹18,130.62 | 58.34 ₹17,629.01 |
| 1.06 | Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar | 79.31 | cum | 2,100 ₹1.7 L | 2,129.84 ₹1.7 L |
| 1.07 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 521.3 | sqm | 85 ₹44,310.84 | 75.87 ₹39,551.33 |
| 1.08 | Dismantling of wash basin/ Sink, closing the pipeline with end cap if necessary, including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead | 12 | each | 935 ₹11,220 | 932.25 ₹11,187 |
Tender Value
₹3.1 Cr
EMD Value
₹1 L
Closing Date
13 Nov 2025, 3:00 pmClosed
KURUVILLA PC
Hi-Care Division Corporate Head Office, Poojappura.P. O, Thiruvananthapuram 695012
Strengthening of Casualty and OP Block at TH Palluruthy, Ernakulam District, Kerala
2025_HCDPS_813862_3
HLL/CMO/HCD/OP/PTY/EKM/25-26
Open Tender
Civil Works - Buildings
365 days
TH PALLURUTHY
Please refer Tender documents.
17 documents required · 17 mandatory
₹8,850
Yes
₹1 L
Yes
30 Jan 2026
5 Nov 2025
14 Nov 2025
5 Nov 2025
13 Nov 2025
5 Nov 2025
Amount
CIVIL WORKS
DISMANTLING AND DEMOLITION
Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge
Dismantling of flushing cistern of all types (C.I. / PVC/ Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead:Of sectional area 40 square centimetres and above
Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
Dismantling of wash basin/ Sink, closing the pipeline with end cap if necessary, including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates,bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge.
Dismantling of plumbing pipe lines of 15mm dia to 110mm dia pipes, including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per the direction of engineer in-charge.
Engaging plumber for repairing, installation, replacement, etc. of pipelines with available materials or the materials should supplied separately if necessary. The rate is inclusive of labour and working tools. works as per the direction of engineer incharge.
Engaging coolie or Beldar for general works complete as per the direction of site engineer in charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm
Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
EARTH WORK EXCAVATION
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge
PCC WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -All work above plinth level up to floor five level: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
RCC WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position machine batched and machine mixed design mix M25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. .All work above plinth level upto floor V level
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
CENTERING AND SHUTTERING
Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
STONE WORK
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
MASONRY WORKS
Solid block masonry using pre cast solid blocks ( factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part 1 of 1979 for foundation and plinth with thickness 20 cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement: 6 coarse sand) etc complete.
PLASTERING
12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
ALUMINIUM WORK
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:250x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm
Providing and fixing Brass100 mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminum doors including necessary cutting and making good etc. complete
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
Providing and fixing glazing in door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): toughened glass of 6 mm thickness.
Providing and fixing frosted film in the fixed glass etc. Complete as per the direction of departmental officers
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm
DOORS AND WINDOWS
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width form 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:100x10 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856, including fixing to frames.
Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately)
Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete.
Providing and fixing Steel S.S- 304 (D) Door Handle of 450mm(1 Handles) ( best make of approved quality ) for Glass, Wooden or similar doors including necessary cutting and making good etc. complete
SITC of Hpl lead flush door 2mm thickness single leaf door for X-Ray room and frames totally flushed with the wall, specially developed for X ray , MRI equipments, Cath labs as well as rooms with radiation shielding requirements. Additional items like door closure, hardware like pull handles, SS hinge, dead lock shall be paid seperately
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty :Float glass panes of thickness 4 mm (weight not less than 10kg/sqm)
Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc
Providing and fixing Mosquito net of suitable size with all necessary screws, fittings etc. as per the direction of engineer in charge.
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S. angels 40x40x6 mm for diagonal braces
STEEL WORK
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
Providing and fixing 25mm V board of approved quality in aluminum doors, windows shutters and partition in aluminium or steel frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer in- Charge.(Frame work shall be paid separately)
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Alumini um sheets (each0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove)shall be measured in sqm. up to two decimal places.
TILE WORKS
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer,in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black , cherry / ruby red .Area of slab over 0.50 sqm
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M - 30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
FALSE CEILING
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
CURTAIN WORKS
Supplying and laying polyester, washable and stain free cloth(Bio-Active fabric washable germ free suitable for sterile area) curtain curtain system with maximum curtain curtain cloth height 230 cm(top 30 cm white colour net and 200cm light blue color as per approval) stitching with stifiner tape, pleats, ironing and laying around each bed using PVC runner with hooks & stopper for hanging/sliding etc. as per the direction of engineer in charge including conveyance to site, laying in line and level, sealing all cutting in false ceiling with powder coated MS cup, all leads and lifts including all labour charges etc. complete. (unpleated length of the cloth measurement will be considered for payment also the bottom and top foldings will not be considered in cloth measurement)/ supplying and fixing powder coated 20mm dia. GI round tube hanging support of required length(app. length 1.10m) one end fixing from slab by using 6mm dia expansion bolt at a distance not more than 2m, c/c down end fixed to powder coated aluminium channel frame 45 x 20mm x 1mm thick section by using SS screw as per the direction of engineer in charge including conveyance.
Providing and fixing of vertical/roller blinds width 100 mm regular quantity made from 100 % polyster/Fibre yarn coated with fade resistant polymer to ensure complete opaquety with zero light transmittance, having suitable coating on exterior, including all fixtures and fittings complete in all respect as per design and instruction of Engineer in-charge and as per site conditions. The colour will be approved by the competent authority.<br> and inclusive of all labour charges.
CUPBOARDS AND RACKS
Providing and fixing panelling or Making Shelf, Racks, Tables, etc : 19 mm thick Greenply Optima G BWP 710 and pressed with inner and outer mica SUD finish and white edge band and appropriate adhesive. Shades, design, etc. as per the direction of site-in-charge
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss/ matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS: 2046 Types S, including cost of adhesive of approved quality.1.0 mm thick
Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete :
Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete.40 mm
Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters, including fixing with necessary screws etc. complete.Triple strip vertical type
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:75 mm
SCRAPPING AND PAINTING
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured)
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineerin-Charge.
Melamine polishing on wood work (one or more coat)
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:One or more coats on old work
Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
PLUMBING AND SANITATION WORKS
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm. weighing not less than 170 gms
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including operated levers
Providing and fixing PTMT Bottle Trap for Wash basin and sink.Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the center of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing uplasticised PVC connection pipe with brass unions: 45 cm length15 mm nominal bore
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge Concealed work, including cutting chases and making good the wall etc. 15 mm pipe 10kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2
Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:20 mm nominal bore
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
Providing and fixing C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.15 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.20 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.32 mm nominal dia pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc.15 mm nominal dia pipes
Providing and fixing CP grating of 6mm thick with rim including setting in floor with white cement mortar and making good the floor :125 mm dia
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
Providing and fixing CP Waste Coupling for wash basin and sink etc, of approved brand, quality and colour. Waste coupling 32mm dia with precisely designed, corrosion resistance and perfect finish.
Providing and fixing square rain water gutter pipes including jointing.<br>150 mm diameter
Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching refilling & testing of joints complete as per direction of Engineer in Charge. 63 mm dia 6Kgf/cm2
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required: Kitchen sink without drain board610x510 mm bowl depth 200 mm
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerincharge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work including cutting chases and making good the wall etc. 63 mm pipe 6 Kgf/cm2
Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
SIGNAGES
Design, providing and fixing Digital Printed vinyl signage boards with transparent 3mm acrylic Sheet with 4 nos. SS Studs with lettering of size 15x45 cm. Complete as per the per the direction of Engineer in charge. <br>
NAME BOARD ACP SHEET WITH MULTIWOOD LETTERING : Design, Supplying and fixing Name Board as per the technical specifications given -1 Inch GI pipe frame (16Guage) for Frame (Size proportional), Primer Paint & Black Painted Pipes for Frame.,5mm ACP sheets (Aluminum Composite Panel) for Box area, 18mm thick Multi wood Lettering for Name Board as approved by<br> Engineer in charge.<br>For Measurement purpose, only area of ACP sheet to be measured
ELECTRICAL
POINT AND CIRCUIT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
CIRCUIT WIRING
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
SWITCH , SOCKET AND METAL BOXES
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 25 amps modular socket outlet and 25 amps modular switch, connection etc. as required for split ac points.
DB AND ACCESSORIES
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pol
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing 40A / 63A, TP MCB, 415 Volts, "C" curve, miniature circuit breaker in the existing MCB DB complete with connections, testing and commissioning etc as required.(VDB outgoings)
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.
CABLE SUPPLY AND LAYING
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
CABLE TERMINATION
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 35 sq. mm (32mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
EARTHING PROTECTION
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
LIGHT AND FAN FIXTURES
Supply Installation of 4 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 20 W, luminaire lumen output of 2000 lumens, luminaire efficacy > 100 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall be made of extruded PC housing, efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. Including all accessories necessary as required to complete installation.
Supply Installation of 2 feet surface/suspended mounted LED batten type luminaire with a power consumption not more than 10 W, luminaire lumen output of 1100 lumens, luminaire efficacy > 110 lm/W with an operating voltage range from 140 V - 270 V. The luminaire shall have a sleek design with extruded aluminum section, white CRCA housing with optically efficient poly carbonate diffuser to provide uniform illumination and wider light distribution. The luminaire shall have a CCT of 4000K /6500 K, CRI > 80, power factor >0.95, SDCM < 5, THD <10%. The luminaire shall be EMI/ EMC compliant and shall have an internal surge protection of 3 kV with 50,000 burning hours as per L70B50 criteria. The luminaire and driver shall be BIS approved and test certificates of LM79 and LM80 reports from NABL accredited labs. The luminaire shall have flicker content <5% and shall have high and low cut off with auto restart feature, including all accessories necessary as required to complete installation.
Supply and Installation of Low glare, high efficiency surface/ recess mounted 12W LED down light , circular profile
SITC of 5 star rated , BEE certified 28W, ceiling fan with BLDC motor, with super enameled copper wire winding, 230 V, single phase 50 HZ remote control operated fan with 1200mm sweep and 3 blades including all accessories as required with remote and standard length down rod all accessories required for complete installation.
Exhaust Fan: SITC of 250mm sweep, 900rpm light duty exhaust fan shutter type white colour, 9" or 10" star rated as per BEE, with its all accessories including mounting as required for complete installation.
SITC of 450mm sweep wall fan having speed control, oscillation control at bottom as suitable for operation on single phase 230 volt AC supply complete with continuous duty motor and all accessories including mounting as required for complete installation.
SITC of 36 W indoor recess mounted LED Light, square, 4000 lumens light output in 5700K CCT, greater than 100 lumens per watt system efficacy, with High Efficiency Extruded aluminium housing and Polycarbonate Diffuser with provision of End to End connection, along with high power LED having minimum 50,000 burning hours as per L70. The driver shall , power factor > 0.9, and including all the necessary accessories as required complete. The luminaire and Driver shall be saperately BIS Approved.
FIRE FIGHTING SYSTEMS
SITC OF ISI marked (IS:2878) fire extinguisher CO2 type capacity 4.5kg. Flat base including valve, discharge hose of not less than 10mm dia , 1 meter long and complete in all respects including initial fill with CO2 gas conforming to IS:307-1996 filled to filling rate of not more than 0.667 and wall bracket (fixed with anchor Fastner) or floor mounted
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required.
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning of manual call boxes of MS Construction in surface/recess with stainless steel chain & hammer assembly Complete with glass and push button etc. as required.
FIRE DETECTION AND ALARM SYSTEM (CONVENTIONAL)Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.6 Zone
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.speaker cable Single pair, 2-core, 1.5 sq mm
NETWORKING AND TELEPHONE
Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
Supply ,Installation ,Testing and Commissioning of 24-Port Gigabit Smart Switch with 4 Combo SFP Slots and 10/100/1000Mbps RJ45 Port with power supply of 100 240VAC, 50/60Hz Dimensions (W x D x H) 17.3 x 7.1 x 1.7 in. (440 x 180 x 44 mm), 19-inch Rack mount Steel Case, 1U Height
Supply, installation, testing and commissioning of Cat6 Information Outlet, RJ45 with all accessories required at site to complete the work as per technical specification
SITC OF 6U Rack with PDU unit with Suitable for all type of DVR Box & Double DVR / Network Switch / Server Rack with 4 Power Socket & Cable , Tray (1No) - 1 Cooling Fan Lock & Key.
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
EPABX System of 24 lines extendable to 64 lines, No. of Junctions -4, Console Operator-1, ISDN Compatible. Extendable to 64 intercom connection; Internal/External Music on Holding, Operator/Auto-attendant Mode, Remote Programming Day/Night Mode (Manual), Music and Ringing Recordable OGM (outgoing message), Music Duration 20 Seconds Caller ID, Call Transfer, Call Forwarding Manually, Outgoing Call Transfer, Power Failure Transfer, Specific Main Line (CO/Trunk Line) Dialing, Three Way Conference, Do Not Disturb, Auto/Manual Dial-Out Mode Type: Digital, Analog Temperature Range : 0-50 Operating Humidity: 0-95%, Non Condensing
Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
PA SYSTEM
PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required.
PUBLIC ADDRESS SYSTEMSupplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required.
CABLING & WIRINGSupplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply, installation, testing and commissioning of PA wired microphone handheld as per the direction of Engineer in charge.
PANELS
SUB PANEL :Fabrication, supply, erection, testing and commissioning of floor or wall mounting dust and vermin proof, cubicle type, front operated MV panel board as per IS 8623 - CPRI Certified made out of 16 SWG thick CRCA sheet (7 tank treatment) fully compartmentalized complete with hinged and earthed front doors with name plate, danger notice board, heavy duty rubber gaskets, removable gland plates made out of 3mm thick sheet steel including all components as shown in the schematic drawing. The panel shall be with Top/bottom entry to receive incoming & outgoing, all opening parts of the panel shall be sealable. Providing all connections and interconnections as required and providing all accessories as required for complete installation as instructed by engineer in charge/consultant and as shown in the schematic layout provided. Incomer - 125A 36kA FP Microprocessor based MCCB having isolation duty , isolation duty type 100A 433V, 25kA best conductivity extensible Al TPN bus bar with SMC supports, heat shrinkable sleeves etc. complete as required. Multifunction meter having multiline LED display with following parameters -Phase wise instantaneous and Average values–Voltage, Current, Power Factor, Phase wise instantaneous and Average values–Active Power, Reactive Power lead & lag, Apparent Power, Import & Export Cumulative values– Active Energy, Reactive Energy lead & lag, Apparent Energy, PF for 3 phases and average, Instantaneous Frequency, Total Harmonics Distortion – Phase wise Voltage and Phase wise Current - 1 Set RYB phase indicating LED lamps with control fuses and switches - 1 set. Outgoings: 63A 16kA FP MCCB Thermal Magnetic based - 8nos.
15KVA UPS
Supply installation, testing and commissioning of following three phase to three phase UPS with inbuilt battery backup, indoor (IP20) in stand alone configuration, true online double conversion DSP based UPS system, with min 15 min backup battery with, input pf>.9, less input current consumption, IGBT rectifier and IGBT inverter. It shall be 100% generator compatible with efficiency > 90% and output power factor > 0.8 and including all accessories etc as required. The UPS system shall be with manual maintenance bypass switch facility. The system shall comply to IEC /EN 62040-1 and relevant IS standard and.The acoustic noise of the system should be less than 58dB. The system shall comply to IEC /EN 62040-1, EN/IEC 62040-2, EN/IEC 62040-3 and relevant IS standard. 15kVA UPS - 1 Nos, Battery Circuit Breaker-1 nos, Battery Required nos. of SMF for providing 15Minutes Backup and Battery Accessories like battery rack, interconnecting cables etc.
Supplying and fixing FP CRCA sheet steel enclosure with provision to mount MCB/Isolator/RCCB/RCBO and other modular devices on surface/ recess complete with connections, testing and commissioning etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 4 x 10 sq. mm
LABOUR WORKS
Electrical Labour works - Dismantling of existing ceiling fan, light fittings using mechanical means or physical means without disturbing the overall structure of proposed area. All items dismantled and shall be made a checklist for returning back to concerned Authorities. All items shall be verified by Electrical Engineer (HLL) before handing over. If any working product is damaged during transit, the same shall be replaced without any additional claim.
COPPER PIPING
12mm OD X .7mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
15mm OD X .9mm THICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
22mm OD X .9mm THIICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
28mm OD X .9mm THIICK Cu PIPE - SITC of copper pipes manufactured from phosphorous deoxidised non-arsenical copper of grade CW024A (Cu-DHP), manufactured EN 13348:2008 to metric outside diameters and having mechanical properties, pipes shall be of R250 (half hard)temper. Pipes shall be degreased suitable for oxygen use and cleanliness is to be maintained by filling each pipe with dry, clean, oil and oxygen free nitrogen, fitting suitable end caps and protectively wrapping. Solid drawn, seamless, deoxidised, non- arsenical, half hard, tempered and degreased copper tubes manufactured to metric outside diameters and should have mechanical properties in accordance with HTM 02-01 and conforming to EN13348:2008.The pipes should also be accompanied with manufacturer’s test certificate for the physical and chemical composition. Copper Fittings should be as per HTM 02-01. All plastic saddles should have brass screws. as per the specifications and requirements, painting of the pipes installed as per color code for medical gas system is also under the scope of contractor.
VALVES
12 mm BALL VALVE (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
15 mm BALL VALVE (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
22 mm BALL VALVE (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards.
28 mm Ball valve (MGPS) SITC of Line Valves for use in plant rooms and to facilitate the isolation of areas or areas where area zone valve are unnecessary. These shall be of the ball valve type and shall be constructed of a nickel plated brass body, PTFE seats and brass chrome plated ball. The valve shall be operated by a manual operating lever by 90º turn. All medical gas line ball valves shall provide a full bore flow and shall be cleaned for oxygen service and fully tested. The valve assembly shall terminate in copper stub pipes to enable brazing directly into the distribution system using the flux less brazing technique. A locking device shall be provided to lock the valve in either the fully open or fully closed position. Line valves shall be located in readily accessible areas of ducts and shafts, however care should to ensure safety to prevent danger from leakage. Line valve installation should be carried out as per HTM 2022/HTM 02-01 standards. Net
GAS OUTLETS AND ACCESSORIES
Gas / Vacuum Outlets SITC of Gas/Vacuum Outlets with Front loading type terminal outlets designed to dispense medical gases or an inlet for medical vacuum to the secondary equipment flow meters, Surgical Tools, Suction regulators, etc. Terminal unit sealed by O ring. The outlets should Quick Connect Type and gas specificity is accomplished by Diametric indexing / Geometric indexing Should have Push to IN and press-to-OUT mechanism for probes. Allows plugging of probes from front. Parking Type probe / connector Self-sealing valve on disengaging the probe (Quick disconnect) Smooth quite action Non return valve for on line servicing/ repairing , Indexed to eliminate interchangeability of gas services, Color-coded gas specific front plate Flow rate exceeds the requirements of ISO 9170 – 1. Totally leak proof, safe & easy to operate Configurations possible: surface, flush & Bead-head. The terminal outlets should comply with ISO and NFPA. Body shall be of one piece brass construction.
Vacuum regulator with suction bottle SITC of Single piece wall mounted suction collection & regulation unit With jar capacity of 600 ml each shall be provided at each of the bed side. Jars would be made of autoclavable materials. The units shall be clamped neatly to the wall using suitable clamps
Oxygen Flow meter with Humidifier Bottle SITC of Flow meter Back pressure Compensated.Flow meter would be accurate gas flow measurement and control within a range of 0-15 liters per minute.It would meet strict precision and durability standards.Flow meter body would be made of brass material. Flow tube and shroud components would be made of clear, impact resistant polycarbonate. The humidifier bottle would be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier would have built in safety valve.
AREA VALVE SERVICE UNIT (AVSU) - 4 gas<br>SITC of 4 gas AVSU as required and as specified under the guidelines laid for Medical gas system, as approved by Engineer HLL
Area Line Pressure Medical Gas Alarm ( 4 gases) SITC of Four channel microprocessor controlled alarm for pneumatic & vacuum services with Digital display of line pressure for all the services with factory calibrated pressure sensors. Color coded LED display of line pressure status (High caution normalcaution- low) Audible Alarm for High & Low pressure condition. Test and Alarm Acknowledge (Mute) facility. (Alarm knowledge (mute) time span is programmable from 1 to 60 minutes). Protected programming facility of alarm limits. The electronic circuitry should be such that if the pressure / vacuum in the gas pipeline drops below the present limit, the equipment should give an audio-visual alarm. Visual alarm should remain active even after pressing of “Mute” button. It should come to normal condition only when gas pressure / vacuum return to normal level. Small and compact design. Mounted on a powder coated MS box. Nut & Nipples should be provided for connection with Pneumatic supply complete as required, all QA/QC should be furnished before Engineer (HLL) before installing the system.
AREA VALVE SERVICE UNIT (AVSU) 2 gas - SITC of 2 gas AVSU as required and as specified under the guidelines laid for Medical gas system, as approved by Engineer HLL
Area Line Pressure Medical Gas Alarm ( 2 gases) - SITC of two channel microprocessor controlled alarm for pneumatic & vacuum services with Digital display of line pressure for all the services with factory calibrated pressure sensors. Color coded LED display of line pressure status (High-caution normal caution- low) Audible Alarm for High & Low pressure condition. Test and Alarm Acknowledge (Mute) facility. (Alarm knowledge (mute) time span is programmable from 1 to 60 minutes). Protected programming facility of alarm limits. The electronic circuitry should be such that if the pressure / vacuum in the gas pipeline drops below the present limit, the equipment should give an audio-visual alarm. Visual alarm should remain active even after pressing of “Mute” button. It should come to normal condition only when gas pressure / vacuum return to normal level. Small and compact design. Mounted on a powder coated MS box. Nut & Nipples should be provided for connection with Pneumatic supply complete as required, all QA/QC should be furnished before Engineer (HLL) before installing the system.
MGPS MACHINES
AUTOMATIC OXYGEN CONTROL PANEL - SITC of automatic control panel having following features -Would be enclosed in a metal cabinet with a hinged cover. The side covers of the panel would be made of fiber glass. Panel cover would be fitted with a lock to prevent unauthorized access can be swung open for maintenance. It would be Fully Automatic Changeover operation and no manual action. The service gas would pneumatically operate gas change over system. Delivery of gas through control panel would not be dependent on electricity. Would be capable of delivering very high flow rate not less than 1300 litres per minute at delivery pressure. Would have Visual indication of the state of the manifold by 3 gauges within the control panel, which would be clearly visible through the transparent cover. Would have Audio – visual alarm indication for changeover of empty cylinder bank to filled cylinder bank. Built in transformer to ensure safe operation by low voltage. Microprocessor based alarm signal control with high ‘db’ Siren system and can be operated with single/Three phase AC system at 50 Hz.
BED HEAD PANEL- Supply, Installation,testing and commissioning of Bed head panels(1.2m) with Terminal unit with accessories - IV Stand, Monitor stand wall mounted, Ward vacuum unit clip, Provision for Gas/Vacuum outlets as follows - Two oxygen outlet, One Vacuum outlet, One Compressed Air outlet 4 Bar, Provision for electrical and data connections as per the direction of Engineer in charge
MEDICAL AIR SYSTEM WITH AIR RECEIVER AND CONTROL PANEL - The duplex compressed Air System with 02 Nos Oil free medical grade air compressor capacity to produce 300-500 liters approximately free air delivery at maximum pressure of 90 PSI. It would be fitted with 5 hp capacity induction electric motor of class F insulation It will be pre fitted with slide rails.The compressor would be installed duly fitted with suction filters, after coolers with moisture separator. The moisture separator and after coolers duly fitted with electrically operated auto drain traps will also be provided before air receiver. This system would also have one number vertical MS air receiver as per IS 226 with construction code IS 2825 of 250 ltr WC duly fitted with safety valves, drain valves, pressure gauges etc. An automatic twin chamber heat less air drier would also be installed to dry 20 CFM compressed air at 90-psi pressure at a temperature of 0-40 degree centigrade. Outlet dew point temperature would be degree centigrade. The dryer would be automatic duly fitted with pneumatic operated valve, set of filters, pre-filter, oil filter and duly fitted with pressure gauges for test the filter condition. This system would also be fitted with bypass airline, safety valve for pressure release and pressure indicators. * TECHNICAL SPECIFICATION: AIR COMPRESSOR:(2 nos), TYPE 5HP OIL FREE MEDICAL GRADED AIR COMPRESSOR, 2. Air delivery 500 lpm, 3.Working Pressure 60 psi, 4.Higher discharge 90-psi, 5.Driver Coupling, 6.Performance test As per IS 5456 7.Stages, 8.Mounting Skid (In case skid mounted) 9.Cooling Air, 10.Compressor speed650 RPM. ELECTRIC MOTOR: 1.Capacity, 415V 3 Phase, 5.Electric supply 50 Hz. 6.Performance test as per IS 325 7.Starter direct on line 8.Insulation Class F Air Receiver: 1.Construction IS2825 2. Capacity 1000 ltrs, 3.Foundation skid, 4.Blast cap.300psi, 5.Fittings, Pressure gauge Safety valve, Drain trap, Inspection window. Air Drier:-*INLET CONDITIONS 1. Flow Rate 20 cfm 2. Pressure 60psi 3. Temperature 40c Max and Moisture Contents 100%.
SITC of 8bar to 4 Bar pressure control in the pipeline system with necessary accessories and all mounting requirements. The control must be easy to operate and have provision for displaying line pressure with necessary cut of valve
AIR DRYER - SITC of Medical Breathing air dryer consists of Air dryer with 40 CFM and 6 nos of 15mm Valve , Bacterial filter with Voltage : 100 - 240 VAC, 50/60Hz, 1ph Power Consumption : 40 Watt Max, Maximum working pressure : 16 bar (g), Minimum working pressure : 4 bar (g), Rated inlet Temperature : 38&deg;C, Rated inlet pressure : 7 bar(g), CO Level : 10 PPM, (Alarm set point) as per NFPA 99, Air Quality : 20C PDP (Alarm set point), as per NFPA 99, 0.01 micron particle level, Cycle Time : 4 min, Dewpoint dependent change over as per the direction of Electrical Engineer in charge. The air dryer should have large condenser for high ambient temperatures, The dryers have been designed for nominal standard inlet conditions as per ISO 7183 - 2007, Dryer quality class - ISO 8573 - 1 : 2010 (E) class, Working Pressure 15kg/cm2 , Dew Point : 40 Degree.
VACUUM PLANT 2nos of 5HP with 1000 litre Air receiver and Control panel - The vacuum system is installed by providing 2 nos. vacuum pumps of reputed make of single stage, 2 cylinders.This pump is stationary, air cooled; splash lubricated, base plate mounted reciprocating type.This pump would fitted on base plate and belts would be guarded. The company also provide 2 no. vaccum tank of suitable water capacity as per IS 225 and construction code as per IS 2825 with all its accessories like vacuum gauge, drain valve, inspection window etc. The company will provide interconnection copper piping of size 12mm 0.0 to 28mm OD with BSP vertical non return valve of required size with vacuum gauge of required size of bottom connection with silencer and vacuums filters and all other work to complete the vacuum system and as per the entire satisfaction of Hospitals authority. The capacity of the pump would be about 45 cfm per minute vacuum at 684mm (HB). TECHNICAL SPECIFICATION :VACCUM PUMP : (2 NOS), Lubrication Splash, Vacuum/ Suction 45cfm, Vacuum 684mm (HB)(MAX.), Driver Electric Motor, Performance test International Standard, Stages 2, Mounting Skid mounted Vertical, Cooling Air cooled 10. Vacuum speed 600 RPM, ELECTRIC MOTOR : Capacity 5HP each, Insulation Class F, VACCUM RECEIVER : Construction IS2825, Capacity 1000ltr (appox.), Foundation Skid 4. Blast Cap.300psi, Fittings, Pressure Gauge ,Safety Valve ,Drain trap Inspection Window. (Necessary rate for valves also included in this item). The system should have filter, NRV, Silencer, Differential pressure switch.
NITROUS OXIDE MANIFOLD - 2X2 - SITC of 2+2 Size Nitrous Oxide Manifold would be suitable to withstand a pressure of 140 kg/cm2 and above along with high pressure copper annealed tail pipe with end Brass adapter suitable for Nitrous/oxygen Cylinder and Manifold. Top frame comprising of high pressure copper pipes of size 12mm O.Dx1.5mm wall thick, with high pressure brass fitting made of high tensile brass and connections through non –return values; high pressure copper tail pipes ,made of high pressure copper pipe of size 7mm I.d×1.5mm wall thick .The design of middle and bottom frames would be provide to fit both round and flat bottom cylinder safely.The manifold would be tested (hydraulically)at 3500 pig. Nitrous oxide 2+2 mainfold with MOX type regulator for control & 1 (outlets-Din point for emergency having suitable valve for both on & off purpose.
AIR CONDITION WORK
HVAC SYSTEM FOR CASUIALITY
Supply, Installation, Testing, and Commissioning of minimum 4.0TR 3 STAR BEE rated INVERTER type, 4-way cassette split AC units, suitable for single or three phase AC supply. Each unit shall consist of an outdoor unit with a hermetically sealed, suction-cooled, energy-efficient scroll or rotary compressor operating on R 32/ R-410A/ R-407C refrigerant, and a ceiling-mounted, 4-way cassette type indoor unit with a powder-coated, pretreated sheet metal cabinet. The indoor unit shall include an inbuilt drain pump, statically and dynamically balanced blower for silent operation, and synthetic washable media filters arranged for convenient cleaning. Installation shall include power and control cabling in PVC conduits, good quality copper refrigerant tubing with elastomeric nitrile rubber insulation, and an insulated drain line terminated at an agreed drain point. Each unit shall be supplied with a full function wireless remote control for temperature, mode, and fan speed settings, and a thermostat. The outdoor unit shall be equipped with overload protection, an air-cooled copper condenser coil of sufficient depth and face area, a propeller type fan with a suitable motor, service valves, and a refrigerant filter, all housed in a powder-coated cabinet. WARRANTY: The system must include a MINIMUM 01-year Original Equipment Manufacturer (OEM) warranty for the total machine and a 03-year warranty on compressor. Warranty Certificate to be submitted for approval. Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier
Supply and installation of HEAVY DUTY mild steel (M.S) OUTDOOR STAND for 3.0TR / 4.0TR split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in-Charge’s directions, ensuring level alignment with wall/floor mounting options
Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units (3.0TR/4.0TR), comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling.
Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system.
Supply, laying and testing of Protective layer for Copper piping with woven fibre glass cloth wrapped around copper piping tubular insulation and with foster painting as required and as directed by Engineer in charge .
HIWALL SPLIT FOR OTHER CRITICAL ROOMS
Supply, Installation, Testing and Commissioning of 1.5TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature). WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval. Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier
Supply and installation of automatic voltage STABILIZERS suitable for 1.0TR/1.5TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short circuit and surge protection
Supply and installation of heavy-duty mild steel (M.S) OUTDOOR STAND for split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in Charge’s directions, ensuring level alignment with wall/floor mounting options
Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system.
Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units, comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling.
HIWALL SPLIT FOR OTHER ROOMS
Supply, Installation, Testing and Commissioning of 1.5TR BEE 3 STAR rated INVERTER-Type Air-Cooled Hi-Wall Split-Type Air Conditioners, complete with Indoor Unit (IDU), Outdoor Unit (ODU), surface/concealed copper refrigerant piping with insulation (closed-cell elastomeric nitrile rubber tubular pipe section) up to 3 meters (IDU to ODU), copper power cable up to 3.5 meters (IDU to ODU), including drain pipe, R-32/R-410A/R-407C green refrigerant, wireless remote control, suitable for working between 180–260V with low & high voltage cutoff and 50 Hz, single phase AC supply, capable of performing cooling, dehumidification, and air circulation of the following capacity with scroll/rotary compressor—the system shall be able to deliver 100% of the rated capacity up to 42°C. The unit must be able to operate up to 50°C (outdoor ambient temperature). WARRANTY: The system must include a MINIMUM 5-year Original Equipment Manufacturer (OEM) warranty for PCB, 10-year warranty on compressor, and 1-year warranty for the total machine. Warranty Certificate to be submitted for approval. Approved Make : Hitachi, Daikin, Toshiba, Trane, O-General, Mitsubishi Electric, Voltas, Bluestar, Carrier
Supply and installation of heavy-duty mild steel (M.S) OUTDOOR STAND for split AC units, comprising of powder-coated mounting brackets with anti-corrosion treatment including all necessary galvanized mounting bolts, nuts, washers, and anchor fasteners. Installation shall be as per manufacturer guidelines and Engineer-in Charge’s directions, ensuring level alignment with wall/floor mounting options
Supply and installation of automatic voltage STABILIZERS suitable for 1.0TR/1.5TR split AC units, complete with all necessary wiring, connectors, and wall mounting hardware. The stabilizer shall feature intelligent microprocessor-based control with SMT/PTH IC technology, ±1% output voltage accuracy, and startup time delay protection. It shall operate within 170V-270V AC input range (50Hz) with auto-reset low/high voltage cut-off, manual-reset thermal overload protection, short circuit and surge protection
Supply and installation of insulated PVC condensate DRAIN PIPING for split AC units including wall chasing, solvent-welded joints, and complete with clamps at regular intervals. Installation shall be with adequate slope towards drainage point. Work includes all necessary bends, couplings, P-traps and termination into designated drainage system.
Supply and installation of ADDITIONAL REFRIGERANT PIPING KIT for split AC units, comprising of Seamless copper tubing with wall thickness as per AC manufacturer's specifications, flame retardant elastomeric nitrile rubber insulation of minimum 13mm thickness all including necessary power and control cabling.
DISMANTLING SPLIT AC
Dismantling, re installation and commissioning of HiWall Split AC (IDU and ODU) units (1.0TR/1.5TR/2.0TR) with water service, gas top up, including all necessary fittings for recommissioning complete as required as per the direction of Engineer in charge.
Bankers Construction (BID ID -2437223)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.60 MB
TEDOPALLURUTHY.pdf
Tender Documents • 4.68 MB
BOQ_1373360.xls
BOQ • 0.52 MB
Download all tender documents and submit your bid