Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23,150.35Accepted-AOC | L1 | Accepted-AOC LOWEST CONTRACTOR AGMT EXECUTED | |
| 2 | L2₹24,371.46+₹1,221.11 (5.27%)Rejected-AOC | L2 | Rejected-AOC LOWEST CONTRACTOR AGMT EXECUTED |
Tender Value
₹25,387
Closing Date
15 Jul 2026, 4:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
O/o Assistant Executive Engineer, PWD Electrical Subdivision, Civil Station, Alappuzha-688001
DEPOSIT-DEO office-Urgent repairs of DEO office at Alappuzha to prevent leakage of roof.-Work-General Electrical Work
2026_PWD_850675_3
PWD/BLDG/TR/7206/2026_6_1_1/1
Open Tender
Electrical Works
Percentage
270 days
Alappuzha
Please refer tender documents
12 documents required · 12 mandatory
₹335
25 Aug 2026
4 Jul 2026
18 Jul 2026
4 Jul 2026
15 Jul 2026
4 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical Maintenance | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | 1,689.22 | - |
| 1.002 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture | - | each | 1,245.56 | - |
| 1.003 | OD21751/2026-2027:Supplying and fixing PVC batten/ Straight holder including connection etc. as required. | - | each | 118.42 | - |
| 1.004 | OD21716/2026-2027:Supplying and fixing 9W Inverter Bulb as required. | - | each | 490.06 | - |
| 1.005 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. | - | each | 99.8 | - |
| 1.006 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply | - | each | 2,244.96 | - |
| 1.007 | OD20780/2026-2027:Supply and renewing ceiling fan capacitor including giving connections | - | each | 51.68 | - |
| 1.008 | OD21752/2026-2027:Supply, conveyance, installation, testing and commissioning wall mounting fan of 400 mm sweep sizes using mounting brackets supplied along with the fan and giving connection with existing wire. | - | each | 2,788.76 | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1452309.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.04 MB
Tendernotice_2.pdf
PDF • 0.06 MB
BOQ_1452309.xls
BOQ • 0.26 MB
viewnit7206.pdf
Tender Documents • 0.02 MB
viewsbd7206.pdf
Other Document • 1.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .