Part-A (AMC of UPS Systems)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 2 KVA to 3 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 15 KVA to 20 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 25 KVA to 30 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Only Labour / Engineering Supervision Service Charges for Dismantling, Shifting and Re-installation of ON-Line UPS System with battery Bank.
Supply and fixing of 12V 26 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 42 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 65 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 100 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12 V 180 AH Lead Acid Exide battery XP -1800/ equivalent for DG set with 3 years warranty including wire leads, connections etc complete.
Supply of 24V 20 Amps Battery Charger Working Voltage 230V AC with battery Reverse & Over load / Short circuit protection without Volt / Ammeter.
Supply of 3 Pole 250Amps Power Contactor.
Supply Installation Testing and commissioning of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. Makes: L&T/Seimens/Epcos/Schneider/Havells
Heavy duty Three phase 440V, 50 Hz capacitor (Bank)
Supply and Fixing of DC Filter Capacitors 2.5Kmfd to 10 kMFD / 100 to 250VDC 1 Set (3Nos) 72V to 192 VDC operating System 3 to 10 KVA ON - LINE UPS System.
Supply and Fixing of DC Filter Capacitors 2.5Kmfd to 10 kMFD 1 Set (3Nos) 120V to 400VDC operating System 10 to 30 KVA ON - LINE UPS System.
Purchase cost for old life over (failure) existing batteries any make any model under buyback offer.
Part-B (AMC of AMF & APFC Panels)
Annual Comprehensive Maintenance Service Contract Charges for preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG set 100KVA to 750KVA) and Inclusive of Spares Cost for Replacement of during AMC Period such as timers, contactors, fuses, indicators, MCB's etc., complete including ACB servicing (except AMF relay,100A and above main incomer Contactor / MCCB/ACB switch etc.)
Annual Comprehensive Maintenance Service Contract Charges for preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750 KVA) and Inclusive of Spares Cost for Replacement of during AMC Period, such as timers, contactors, fuses, indicators, MCB's etc., complete (except AMF relay,100A and above main incomer Contactor / MCCB/ACB switch etc.)
Supply & fixing of AMF Relay suitable for AMF Panel of 100 to 750 KVA DG Set.
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and Inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete. (Except APFC relay, Capacitors, 100A and above main incomer MCCB / SFDU switch etc.)
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel 100 to 200 KVAR (Capacitor Duty Thyristor contactors type) inclusive of all Spares Cost for Replacement of during AMC Period, Such as timers, contactors, fuses, indicators, MCBs, Capacitor Duty Thyresistor contactors etc., complete (Except APFC relay, Capacitors, 100A and above main Incomer MCCB / SFDU switch etc.)
Supply Installation Testing and commissioning of microprocessor based intelligent power factor correction relay having sensitivity up to 50 milli Amp secondary current and following way, self analysing auto c/k setting according to targeted power factor setting, the relay shall have minimum three digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release etc. as required Makes: L&T/Seimens/Epcos /Schneider/ ABB/Neptune
6 to 14 stage - sensitivity upto 50 milli Amp
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
Part-A (AMC of UPS Systems)
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 2 KVA to 3 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 4 KVA to 6 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 7.5 KVA to 10 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 15 KVA to 20 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Annual Comprehensive Maintenance Service Contract Charges for preventive maintenance, Repairs & Servicing of 25 KVA to 30 KVA On-Line UPS systems with Battery Bank maintenance and inclusive of all spares cost for Replacement of During AMC period such as Charger PCB, SCRs, IGBTs, Inverter PCBs, fuses, MCBs, etc., Complete. (except Batteries, DC Filter capacitors 100 Mfd / 100VDC or above, Transformers & Chokes etc).
Only Labour / Engineering Supervision Service Charges for Dismantling, Shifting and Re-installation of ON-Line UPS System with battery Bank.
Supply and fixing of 12V 26 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 42 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 65 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12V 100 AH SMF battery with 3 years Warrenty, including wire leads ,connections etc complete., Makes: Quanta / Racket / Exide.
Supply and fixing of 12 V 180 AH Lead Acid Exide battery XP -1800/ equivalent for DG set with 3 years warranty including wire leads, connections etc complete.
Supply of 24V 20 Amps Battery Charger Working Voltage 230V AC with battery Reverse & Over load / Short circuit protection without Volt / Ammeter.
Supply of 3 Pole 250Amps Power Contactor.
Supply Installation Testing and commissioning of self healing MPP/MP type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz and total wattage loss less than 0.5 Watt per KVAR. including making connections with suitable capacity conductors/cables testing as required. Makes: L&T/Seimens/Epcos/Schneider/Havells
Heavy duty Three phase 440V, 50 Hz capacitor (Bank)
Supply and Fixing of DC Filter Capacitors 2.5Kmfd to 10 kMFD / 100 to 250VDC 1 Set (3Nos) 72V to 192 VDC operating System 3 to 10 KVA ON - LINE UPS System.
Supply and Fixing of DC Filter Capacitors 2.5Kmfd to 10 kMFD 1 Set (3Nos) 120V to 400VDC operating System 10 to 30 KVA ON - LINE UPS System.
Purchase cost for old life over (failure) existing batteries any make any model under buyback offer.
Part-B (AMC of AMF & APFC Panels)
Annual Comprehensive Maintenance Service Contract Charges for preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG set 100KVA to 750KVA) and Inclusive of Spares Cost for Replacement of during AMC Period such as timers, contactors, fuses, indicators, MCB's etc., complete including ACB servicing (except AMF relay,100A and above main incomer Contactor / MCCB/ACB switch etc.)
Annual Comprehensive Maintenance Service Contract Charges for preventive Maintenance, Repairs & Servicing of AMF Panels (Application to DG Set 100KVA to 750 KVA) and Inclusive of Spares Cost for Replacement of during AMC Period, such as timers, contactors, fuses, indicators, MCB's etc., complete (except AMF relay,100A and above main incomer Contactor / MCCB/ACB switch etc.)
Supply & fixing of AMF Relay suitable for AMF Panel of 100 to 750 KVA DG Set.
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel (Capacitor Duty Contactor type) 100 to 200 KVAR and Inclusive of all Spares Cost for Replacement of During AMC Period, Such as timers contactors, fuses, indicators, MCBs, Capacitor Duty contactors etc., complete. (Except APFC relay, Capacitors, 100A and above main incomer MCCB / SFDU switch etc.)
Annual Comprehensive Maintenance Service Contract Charges for Preventive Maintenance, Repairs & Servicing of APFC Capacitor Panel 100 to 200 KVAR (Capacitor Duty Thyristor contactors type) inclusive of all Spares Cost for Replacement of during AMC Period, Such as timers, contactors, fuses, indicators, MCBs, Capacitor Duty Thyresistor contactors etc., complete (Except APFC relay, Capacitors, 100A and above main Incomer MCCB / SFDU switch etc.)
Supply Installation Testing and commissioning of microprocessor based intelligent power factor correction relay having sensitivity up to 50 milli Amp secondary current and following way, self analysing auto c/k setting according to targeted power factor setting, the relay shall have minimum three digit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, indication of switching on units, auto/manual status, and shall have over load protection, no volt release etc. as required Makes: L&T/Seimens/Epcos /Schneider/ ABB/Neptune
6 to 14 stage - sensitivity upto 50 milli Amp
NOTE (i)The rates are of basic rates excluding GST. (ii) The applicable GST will be reimbursed/paid as per actuals on production of proof. (iii)Statutory deductions will be made as per norms, if applicable. Any modalities imposed on GST by the Government from time to time, the same will be implemented.
(Rupees Thirty three lakhs eighty one thousands ninety two and paise eleven only)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ 224.xls
TENDER_DOCUMENT • 2.01 MB
NIT 224.docx
TENDER_DOCUMENT • 0.17 MB
NIT 224.xlsx
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .