Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.3 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | ₹53.3 L Quoted ₹54.7 L | L1 | Accepted-AOC LOWEST QUOTED BIDDER |
| 2 | L2₹54.9 L+₹23,260.41 (0.43%)Rejected-Finance | ₹54.9 L+₹23,260.41 (0.43%) | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 3 | L3₹55.7 L+₹1.0 L (1.90%)Rejected-Finance | ₹55.7 L+₹1.0 L (1.90%) | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 4 | L4₹61.6 L+₹6.9 L (12.6%)Rejected-Finance 2 EVEREST VIHAR PT T N MISHRA MARG NIRMAN NAGAR JAIPUR 302019 | JAIPUR | RAJASTHAN | 302019 | ₹61.6 L+₹6.9 L (12.6%) | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 5 | L5₹76.5 L+₹21.8 L (39.8%)Rejected-Finance | ₹76.5 L+₹21.8 L (39.8%) | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L1 | Rasam Engg Co. L4 | Srinivasa Consructions L3 | Dwarka Pershad Radhey Ramanlal L5 | OM SAI POWER SYSTEMS L2 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling cross-arms of MS channel or angle sections complete & setting aside for credit complete all as specified and as directed. [(329 Spans X 1.5 X 1.8) Kg (LI 30 x 30 x 4 mm for LT OH Lines) + 10% (for Nuts, Bolts, Washers, flats etc.) ] | 9.77 | Qtl | 117 ₹1,143.09 | 500 ₹4,885 | 500 ₹4,885 | 1,000 ₹9,770 | 100 ₹977 Lowest |
| 2.00 | Dismantling insulators any type, any size complete all as specified and as directed. [329 Poles X 4] | 1,316 | Each | 45 ₹59,220 | 5 ₹6,580 | 1 ₹1,316 Lowest | 5 ₹6,580 | 2 ₹2,632 |
| 3.00 | Dismantling ACSR or AAC conductors complete all as specified and as directed. [(329 Spans x 25 x 4 x 84.7/1000) Kg (Squirrel Conductor for LT OH Lines) + 10% (for Sag, Jumperings etc.)] | 30.65 | Qtl | 270 ₹8,275.5 | 500 ₹15,325 | 1,000 ₹30,650 | 2,500 ₹76,625 | 100 ₹3,065 Lowest |
| 4.00 | Supply and laying in trenches/through pipes or bare in road crossings/ paths / drains / ducts / floors / along poles / walls / ceilings / equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4.0 Core 25 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and as directed.
Make: Havells / Finolex / Polycab / Gloster
Note for Item Nos 4 : Quoted rate is deemed to be inclusive of fixing/placing of Cable Route Indicator of type/size as appoved by the Engr-In-Charge at an interval of not more than 50.0 meters & at each & every bend or corner with engraved marking e.g. " MES LT CABLE 25 SQMM 4 CORE " in bold letters during refilling of the trench complete all as specified and as directed. | 8,960 | RM | 216 ₹19,35,360 Lowest | 240 ₹21,50,400 | 234 ₹20,96,640 | 300 ₹26,88,000 | 280 ₹25,08,800 |
| 5.00 | Supply and laying in trenches / through pipes or bare in road crossings/ paths /drains /ducts / floors / along poles / walls / ceilings / equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4.0 Core 10 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and as directed.
Make: Havells / Finolex / Polycab / Gloster | 210 | RM | 162 ₹34,020 Lowest | 185 ₹38,850 | 170 ₹35,700 | 220 ₹46,200 | 200 ₹42,000 |
| 6.00 | M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed. | 100 | RM | 810 ₹81,000 | 800 ₹80,000 | 350 ₹35,000 | 350 ₹35,000 | 32 ₹3,200 Lowest |
| 7.00 | Excavation in trenches by mechanical means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil complete all as specified and as directed.
Note for Item Nos 4, 5 & 6 above :-
(i) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates.
(ii) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates.
(iii) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard.
(iv) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm. | 1,668 | Cum | 216 ₹3,60,288 | 200 ₹3,33,600 | 280 ₹4,67,040 | 350 ₹5,83,800 | 90 ₹1,50,120 Lowest |
| 8.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed. | 1,501.2 | Cum | 63 ₹94,575.6 | 80 ₹1,20,096 | 50 ₹75,060 | 50 ₹75,060 | 5 ₹7,506 Lowest |
| 9.00 | Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed. | 166.8 | Cum | 63 ₹10,508.4 | 80 ₹13,344 | 60 ₹10,008 | 100 ₹16,680 | 10 ₹1,668 Lowest |
| 10.00 | M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 77/75 mm & Min ID 63 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 complete all as specified and as directed.
Make : Supreme / Astral / Finolex / Polycab. | 7,410 | RM | 117 ₹8,66,970 | 100 ₹7,41,000 | 120 ₹8,89,200 | 105 ₹7,78,050 | 95 ₹7,03,950 Lowest |
Tender Value
₹66 L
EMD Value
₹1.2 L
Closing Date
22 Dec 2025, 6:00 pmClosed
CWE (AF) Secunderabad
CWE (AF) Secunderabad
SPECIAL REPAIRS TO OVERHEAD / UNDERGROUND CABLE AT AFA HYDERABAD
2025_MES_741312_1
86795/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AFA) Hyderabad
As per NIT
9 documents required · 9 mandatory
₹1,000
GE AFA HYDERABAD
₹1.2 L
Yes
20 Jan 2026
24 Nov 2025
24 Dec 2025
24 Nov 2025
22 Dec 2025
15 Dec 2025
24 Nov 2025 - 11 Dec 2025
Amount
Dismantling cross-arms of MS channel or angle sections complete & setting aside for credit complete all as specified and as directed. [(329 Spans X 1.5 X 1.8) Kg (LI 30 x 30 x 4 mm for LT OH Lines) + 10% (for Nuts, Bolts, Washers, flats etc.) ]
Dismantling insulators any type, any size complete all as specified and as directed. [329 Poles X 4]
Dismantling ACSR or AAC conductors complete all as specified and as directed. [(329 Spans x 25 x 4 x 84.7/1000) Kg (Squirrel Conductor for LT OH Lines) + 10% (for Sag, Jumperings etc.)]
Supply and laying in trenches/through pipes or bare in road crossings/ paths / drains / ducts / floors / along poles / walls / ceilings / equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4.0 Core 25 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and as directed. Make: Havells / Finolex / Polycab / Gloster Note for Item Nos 4 : Quoted rate is deemed to be inclusive of fixing/placing of Cable Route Indicator of type/size as appoved by the Engr-In-Charge at an interval of not more than 50.0 meters & at each & every bend or corner with engraved marking e.g. " MES LT CABLE 25 SQMM 4 CORE " in bold letters during refilling of the trench complete all as specified and as directed.
Supply and laying in trenches / through pipes or bare in road crossings/ paths /drains /ducts / floors / along poles / walls / ceilings / equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4.0 Core 10 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and as directed. Make: Havells / Finolex / Polycab / Gloster
M&L for cutting the existing hardstanding/PCC/WBM road/rocky surfaces at a depth of not less than 75 cm & 30 cm in width for passing of HT cables through GI pipes, returning filling in, complete incl finishing the surfaces by providing cement concrete type B1 (1:2:4) with 20 mm graded aggregate upto 20 cm, finishing to a uniform smooth surface complete all as specified and as directed.
Excavation in trenches by mechanical means n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil complete all as specified and as directed. Note for Item Nos 4, 5 & 6 above :- (i) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. (ii) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates. (iii) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard. (iv) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 77/75 mm & Min ID 63 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 complete all as specified and as directed. Make : Supreme / Astral / Finolex / Polycab.
M&L for anti-climbing devices, comprising of 2.24 mm dia galvanised steel 2-strand barbed wire with 2.00 mm dia barbs wrapped spirally round poles, to a length of 0.5 mtr to 1.0 mtr clamped & properly secured complete all as specified and as directed. (clamps measured separately).
S&F danger notice plate of size 25 x 20cm of 1.6mm thick mild-steel sheet, vitreous enamelled white, with letters, figures and conventioinal skull and bones in signal-red colour and fixed with MS clamps, bolts and nuts of approved size, for LT conforming to IS-2551 complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv earthing assy complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to GI earth strip 32 x 6 mm by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with suitable funnel and wire mesh, 40 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv earthing assy complete all as specified and as directed.
M & L for laying earth continuity conductor or main earthing lead of 32x6 mm galvanised iron strip, fixed to wall on batten or recess or chasses or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc, as required complete all as specified and as directed.
M&L for GI pipe light grade with all running fittings (ISI Marked), fixed on Perimeter/Street light PCC poles etc. of bore 15 mm complete all as specified and as directed. Make : TATA/JINDAL/PRAKASH.
M&L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 40 mm complete all as specified and as directed. Make : TATA/JINDAL/PRAKASH. Note for Item Nos 16 & 17 above : Wherever GI Protection pipes are to be placed/fitted above earths surface, cost of necessary clamping/fixing arrangements to the entire satisfaction of Engr-In-Charge is deemed to be included in the unit quoted rates.
S&F LED flood light fitting of capacity 200 Watts or higher rating, Power factor >0.95, colour temperature not >5700 K, luminous efficacy >100 lumens/watt, IP-66 including electronic driver (SMPS based constant current supply with lower THD, output open/short circuit protection, phase to phase protection, over voltage protection, surge voltage protection etc.) unit suitable for working voltage 140-270V AC, 50 Hz, pressure die cast aluminium housing and finishing epoxy powder coated with all accessories as per manufacturers instructions of Make: LUKER, Cat No : LFL200LNS or techno-commercially equivalent in HAVELLS/BAJAJ/PHILIPS/JAGUAR including necessary fixing arrangements by means of appropriate sized MS Clamps, nuts, bolts, washers etc. on RCC/Steel poles and connecting up electrically from Junction box to light ftg by means of 3 core 1.5 sqmm copper PVC round conductor passing through 15 mm dia light grade GI Pipe & necessary Aluminium clamps, nuts, bolts, washers etc. incl taking down old unsv conventional light fittings complete all as specified and as directed.
Supply and fix energy saving high power LED Street light of 50W or higher rating made up of pressure die cast aluminum housing with embedded PC cover having top opening, seperate driver compartment with IP66 protection & fixing/fitting on existing GI pipe bracket and connecting up electrically from Junction box to light ftg by means of 3 core 1.5 sqmm copper PVC round conductor passing through 15 mm dia light grade GI Pipe & necessary Aluminium clamps, nuts, bolts, washers etc. incl taking down old unsv conventional light fittings complete all as specified and as directed. Make: LUKER, Cat No : LSTE050S or techno-commercially equivalent in HAVELLS / BAJAJ / PHILIPS / JAGUAR.
S & F loop in-loop out junction box of internal dimension 140 x 140 x 95 mm or higher size made out of FRP sheet with weather proof canopy and locking screw comprising of 20 Amps rated 4 way connectors for 3 Phase and Neutral incoming/out going mounted in the box, fixing on RCC poles etc. with & including suitable sized Aluminium/MS clamps, cable glands, lugs, nuts, bolts etc. & fitted with 01 Nos MCB SP 10A, 10KA breaking capacity, C Series complete all as specified and as directed. Make of FRP Junction Box : Sintex/CAPE ELECTRIC/HENSEL or techno-commercially eqvt. Make of MCB SP : L&T/Legrand/ABB/SIEMENS. Imp Note for Item Nos 18 to 20 above : (i) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iii) Cost of 15 mm dia GI Pipes incl necessary clamping as directed by the Engr-In-Charge shall be measured & paid separately under relevant items.
S & F MCB, DB, TPN, 4 ways, DOUBLE DOOR, IP-43, Ik-09 with metal door, rated bus bars, earth bar, neutral links complete incl. blanking plates as required & fixed flush to wall/other surface complete all as specified and as directed. Make : L&T/ABB/SIEMENS/LEGRAND.
S & F MCB, TPN, 10KA, 415V, "C" curve, 20 A, ISI marked complete. (1W + 1S) complete all as specified and as directed. Make : L&T/ABB/SIEMENS/LEGRAND.
S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA complete all as specified and as directed. Make : L&T/ABB/SIEMENS/LEGRAND.
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA complete all as specified and as directed. Make : L&T/ABB/SIEMENS/LEGRAND. Note for Item Nos 21 to 24 above: The Make / Model of MCB DBs & MCBs shall be the same.
Supply, install, commissioning & testing of LT control panel board "out-door type" of size 1000 mm (height) x 900 mm (breadth) x 500 mm (depth) (minimum dimensions) factory fabricated CPRI approved (type-tested) with suitable neoprene rubber gasket to make it completely dust & vermin proof & degree of protection not less than IP-55 & general construction confirming to IS-13947, double door, front & back openable. The panel shall be provided with ventilation facility in the form of louvers for better heat dissipation & tinned copper bus-bar wrapped with coloured PVC tape/sleeves of rating in conformity to the Incoming ACB/MCCB rating. The panel board shall be fabricated out of 3.15 mm thick (for outer portions) & 2.0 mm thick (for inner portions) CRCA sheet duly pre-treated & powder coated, supporting angle iron frame & MC channel base suitable for 3 Ph, 4 wire system 415/440 volts grade incl complete internal wiring with not less than 2.5 sqmm copper wire incl cable glands of suitable sizes incl suitable PCC (1:3:6) type C-2 foundation , necessary earthwork (if any) complete all as specified and as directed with & incl the following accessories : [ Main 25 KVA O/G Transformer Panel ]
BUS-BAR & INTERNAL CONNECTIONS : The bus-bars shall be made up of 04 Nos high grade Aluminium 100 A rated, duly insulated with 1100 V grade standard colour coded PVC sleeves & rigidly mounted on suitable sized "F" class insulators of non-hygroscopic, non-combustible, all internal connections from main bus-bars to switch gears etc.
PROVISION FOR CABLE ENTRY : The provision for cable entry/exit shall be provided in the bottom for both incoming & out-going cables with the help of glands matching the existing LT cable sizes.
OUTGOINGS : (a) MCB, TPN, 10KA, 415V, "C" curve, 16 A, ISI marked - 02 Nos (1W + 1S). Make : L&T/ABB/SIEMENS (b) Street/Perimeter light Control Panel suitable for 6.0 KW load, Contactor Rating 32 A TP, MCB Rating 40 A TPN, Digital 24 hour switch suitable for mounting inside LT Panel for automatic operation. Make : Cat No IHXTS03060 OF Make Havells or techno-commercially equivalent confirming to IS/IEC 61439 & 60529 with & incl extended wide band coil, FRLS internal wiring, in-built short-circuit protection, Class H insulation.
Note:- (i) Design / drawing / BOM of the Panel Board incl all accessories showing the dimensions is to be obtained from the Manufacturer / Supplier & is to be got approved from the Engr-In-Charge & GE before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. (iii) The electrical connection of digital Multi Functional Meter in the ATS panel is to be done from load side so that monitoring of various parameters viz. Voltage, Current, KW, KVA, power factor, frequency etc. can be done for both SEB mains & DG mains. (iv) Necessary PCC foundation/plinth shall be as per the recommendations of OEM & cost of the same is deemed to be included in the quoted rates.
M&L for preparation of old painted surfaces of PCC Poles & applying two coats of weather coat paint of approved colour & grade incl writing of Pole Numbers & also painting of GI Pipe brackets & clamps with two coats of Aluminium Paint over a coat of red oxide primer complete all as specified and as directed. Note : Cost of use/hiring/rent including transportation of Aluminum Ladders/Scaffolding arrangements etc. required for successful execution of the complete work/Job is deemed to be included in the unit quoted rates. Quoted rate is also deemed to be inclusive of all safety precautions/measures to be taken by the contractor for labour employed at the site.
OM SAI POWER SYSTEMS (BID ID -3510732)
Srinivasa Consructions (BID ID -3504521)
Rasam Engg Co. (BID ID -3501024)
Dwarka Pershad Radhey Ramanlal (BID ID -3505161)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
86795TENDERPDF.pdf
Tender Documents • 0.81 MB
BOQ_830084.xls
BOQ • 0.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .