Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹40.1 L+₹1.1 L (2.91%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹41.6 L+₹2.6 L (6.70%)Rejected-AOC PLOT NO 626 627 GIDC BEHIND GANGOTRI DIARY PORBANDAR 360 577 | PORBANDAR | GUJARAT | 360577 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹41.9 L+₹3.0 L (7.72%)Rejected-AOC | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹42.6 L+₹3.7 L (9.42%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
21 Mar 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG PORBANDAR
Military Engineer Services, GE I CG Porbandar, DHQ No. 1, Opp. Birla Cement Factory, Porbandar-360575
PROVISION OF CERTAIN SANCTIONED WORK UNDER PARA 35 AT RESTRICTED AREA OF RHQ (NW) OFFICE COMPLEX UNDER GE (I) CG PORBANDAR
2023_MES_584874_1
8869
Open Tender
Civil Works
Item Rate
180 days
LEKAWADA
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹68,000
Yes
28 Apr 2023
8 Mar 2023
22 Mar 2023
8 Mar 2023
21 Mar 2023
15 Mar 2023
Amount
SCHEDULE 'A'
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed
Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed .
S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed
M&L for 12 mm thick Seamles calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish (Frame work for ceiling shall be measured and paid separately complete all as specified and directed
M&L for applying two coats of Oil emulsion distemper (OBD) over a coat of Ceiling putty including preparing the ceiling surfaces complete all as specified and directed
S & F Anodised aluminium snap grid 605mmx605mm frame work for false ceiling complete all as specified and directed
Providing and fixing Perforated particle board/ tiles for insula-tion and accoustic purposes, 60x60 cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
M & L for double charged Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
Providing and fixing Gypsum Board 12mm thick in walling fixed with screw as per manufacturers instructions complete all as specified and directed
M & L for Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats over a coat of plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth.
S & F of aluminium frame for doors,windows, ventilators, Partitions, powder coated (Minimum thickness of powder coating 50 micron) with one or more rebates including joining cleat for fixing etc. complete all as specified and directed
S & F of powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
S & F of 6mm thick Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sqm in each pane complete all as specified and directed
S & F of 6mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to timber frame work or aluminium section complete all as specified and directed
Taking down carefully aluminium/copper point wiring (light,fan,socket or power) concealed and casing caping complete including fittings and fixtures such as switches,ceiling roses,pendants,regulators,sockets light fittings and making good the disturbed surfaces of walls/ceiling/floor etc.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces complete all as specified and directed.
Disconnecting electric connections and taking down old unserviceable MCB SPN/SP/TP and DB's of any capacity complete all as specified and directed.
Taking down old unserviceable fittings complete all as specified and directed.
M&L for Point wiring complete with 1.5 sqmm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable 650/1100 Volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit (minimum 20 mm dia external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR part- I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/ recessed in wall or ceiling etc including 1.5 sqmm PVC insulated but unsheathed multistranded copper conductor FRLS cable as earth continuity wire including modular type metal flush box with cover plate and frame of required modules for mounting of modular switches, sockets, switch sockets, fan regulators with required modules all as specified etc for the following:-
One light /fan point controlled by one, one way switch
One 3 pin 6 Amps socket outlet on same board
One 3 pin 6 Amps socket outlet on independent board .
M&L for Point wiring complete with 2.5 Sqmm single core PVC insulated but unsheathed multistrand copper conductor FRLS cabeI 650/1100 Volts grade conforming to IS-694 drawn through PVC conduit (minimum 20 mm dia (external) but shall be increased as per actual site requirement in accordance with clause 19.125 of SSR Part I) ISi marked with wall thickness not less than 1.8 mm heavy duty including conduit accessories concealed pressed steel terminal boxes of size cover white/coloured including 2.5 Sq mm PVC insulated but unsheathed copper conductor FRLS cable as earth continuity wire for one 3 pin 15 or 16 Amps socket outlet on independent board, including modular type metal flush box with cover plate and frame of required module for mounting of modular switches, sockets, switch sockets with required modules all as specified.
Supply & fix modular switch 1 way, 6 Amps, 1 modular (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular switch 1 way, 16 Amps, 1 modular (ISI marked).complete all as specified and as directed.
Supply & fix modular socket, 6 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
Supply & fix modular socket, 6/16 Amps, 2/3 pin combind 2 module (ISI marked).complete all as specified and as directed. Make : Legrand / Anchor (Roma)/ L&T
S&F of LED Down lighter 7 w complte all as specified of make Philips Cat No:7W Sky COB Tilt LED Spotlight (NW) or equivalent in Wipro/GE complete all as specified and directed
S&F of LED False ceiling light fitting, 11 Watt (Mollis LD06 - 5700K) and including connected with 2 core flexible copper wire 0.50 Sq mm from ceiling rose after fixing fitting in position at site all complete all as specified and directed. Make:Wipro Cat No DS73100/ Philips DN296B LED12S-6500 PSUor equivalent to Havells /CG
S&F of LED down lighter 2x2 ,36 w down lighter complte all as specified and directed of make : wiproCRCO10R036HP57HEG2/Philips RC383B LED 36S-4000 PSU or equivalent in GE
M&L for sub main wiring with two single core 2 x 4 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1x 2.5 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&L for sub main wiring with two single core 2 x 6 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 4 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&L for sub main wiring with two single core 4x6.0 sq. mm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 6 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
M&L for sub main wiring with two single core 4x 10 Sqmm PVC (FRLS) insulated multistranded flexible copper conductor cable 660/1100 volts grade down in through including Concealed PVC Conduit with all accessories, PVC insulated 1 x 10 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC conduit will be measured and paid one unit.
S & F in repair VTPN DB 04 Way made of CRCA sheet, for flush mounting type with 250 Amp busbar copper, fully insulated & shrouded neutral bar, earth bar, fixed on wall, Prefitted masking sheet, Reversible Door confirming to IP 54 all as specified and comprising of following:- (i) MCCB 63 amp FP 36 KA 01 no (incoming) (ii) MCB 40/63 amp TP 10 KA C Curve : 07 Nos (iii) MCB 6/32 amp SP 10 KA C Curve : 03 Nos MAKE: DB & MCCB/MCB : SCHNEIDER/ LEGRAND/ HAGER
S & F in repair VTPN DB 08 Way made of CRCA sheet, for flush mounting type with 250 Amp busbar copper, fully insulated & shrouded neutral bar, earth bar, fixed on wall, Prefitted masking sheet, Reversible Door confirming to IP 54 all as specified and comprising of following:- (i) MCCB 100 amp FP 36 KA 01 no (incoming) (ii) MCB 40/63 amp TP 10 KA C Curve : 07 Nos (iii) MCB 6/32 amp SP 10 KA C Curve : 03 Nos MAKE: DB & MCCB/MCB : SCHNEIDER/ LEGRAND/ HAGER
S & F in replacement of MCB DB 12 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up complete all as specified and directed. Make : Legrand/ Havells/ ABB
S & F in replacement of MCB DB 8 way SPN, double door, vertical type, IP - 53 with 200 Amps rated bus bar, Concealed and connecting up complete all as specified and directed. Make : Legrand/ Havells/ ABB
Supply and fixing in replacement of MCB SPN, 240 volt, 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fixing in replacement of MCB SP, 240 volt, 6 to 32 Amps complete all as specified. Make : Legrand/ Havells/ ABB
Supply and fix earthed metal clad socket outlet with earthed plug top 20 Amps capacity with sheet metal enclosure and one 20 Amps MCB SPN complete all as specified and directed. Make : Legrand/ Havells/ ABB
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed
Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor complete all as specified and directed
M & L for LT panel Board cubical KIOSK Outdoor type compact 415 Volts AC 50 Hz, 4 wire +E, , RAL 7035 finish confirming to IP 54 complete including Cu bus bar 300 Amps, 30 KA, 4 strip mounted on porcelain insulated & enclosed in chamber, bottom cable entry comprising of following :- Make:-Hensel/Hager/Schneider
(a) Incoming MCCB 125 Amps four pole with thermal based release, having breaking capacity 25 KA, ---01 No Make:-ABB/C&S/Siemens/Legrand
(b) Outgoing MCCB 63 Amps four pole with thermal based release, having breaking capacity 16 KA, ---04 No. Make:-ABB/C&S/Siemens/Legrand
(c) MCB SPN , 230 Volt 20 Amps - 1
(e) Digital Voltmeter 0-500 V 96x96m---01 nos.
(f) Digital Ammeter 0-500 A 96x96m---01 nos.
Disconnecting electric connections and taking down old unserviceableVTPN DB with MCC and MCB of any capacity.
Taking down unserviceable indoor unit for Duct AC 8.5 TR with copper piping complete all as specified and directed
Material and labour for Indoor unit for compactable for Air cooled Ductable airconditiner for Model No: DSA1021R1/R2 Blue star complete of capacity 8.5 TR ,Nominal Air flow 5780 CMH& 3400 CFM and power supply 380/420 V ,3 PH ,50 Hz with Blower motor ,Air filter Controller module complte all as specified and as directed of Make : Blue star /Diakin/Hitachi Note : Rate includes all necessary fitting and fixtures including charging of gas suitable for model and neccessary testing and commissioning complete all as specified and directed..
M&L for refrigerant tubing for suction /discharge copper pipe of suitable size including insulation tubing all as per site requirement complete all as specified and directed.
S & F in repair VTPN DB 04 Way made of CRCA sheet, for flush mounting type with 250 Amp busbar copper, fully insulated & shrouded neutral bar, earth bar, fixed on wall, Prefitted masking sheet, Reversible Door confirming to IP 54 all as specified and comprising of following:- (i) MCCB 63 amp FP 36 KA 01 no (incoming) (ii) MCB 40/63 amp TP 10 KA C Curve : 07 Nos (iii) MCB 6/32 amp SP 10 KA C Curve : 03 Nos MAKE: DB & MCCB/MCB : SCHNEIDER/ LEGRAND/ HAGER
Supply and fixing RCBOs double pole 300 mA 32 Amp rating suitable for 240V, 50 Hz in the MCB DB complete with connection testing and commissioning. Make : Legrand/ Havells/ ABB
Supply and fixing RCBOs double pole 300 mA 63 Amp rating suitable for 240V, 50 Hz in the MCB DB complete with connection testing and commissioning. Make : Legrand/ Havells/ ABB
Supply and fixing RCBOs four pole 300 mA 63 Amp rating suitable for 240V, 50 Hz in the MCB DB complete with connection testing and commissioning. Make : Legrand/ Havells/ ABB
Supply and fixing in replacement of MCB SPN, 240 volt, 40 to 63 Amps complete all as specified. Make : Legrand/ Havells/ ABB
SNEH TRADERS
K K Construction Co
M/s PATEL ENGINEERING
Leo Elevator Company
Ramdev and Sons
Shree Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .