Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.3 CrAccepted-Finance | ₹26.3 Cr | 1 | Accepted-Finance As per CQCCBS score 80.91 |
| 2 | 2₹29.0 CrAccepted-Finance 001 CASABLANCA SANGAM PRESS ROAD KOTHRUD PUNE 411038 | PUNE | PUNE | MAHARASHTRA | 411038 | ₹29.0 Cr | 2 | Accepted-Finance As per CQCCBS score 78.81 |
| 3 | 3₹32.7 CrAccepted-Finance SURVEY NO 14 EMBASSY GOLF LINKS BUSINESS PARK BLOCK D 2ND TO 4TH FLOORS BLOCK D INDIRANAGAR KORMANGALA INTERMEDIATE RING ROAD BANGALORE BANGALORE KARNATAKA 560071 | BENGALURU URBAN | KARNATAKA | 560071 | ₹32.7 Cr | 3 | Accepted-Finance As per CQCCBS score 73.18 |
| 4 | Rejected-Technical PLOT NO R 270 SYNERGIA IT PARK TTC INDUSTRIAL ESTATE GAUTAM NAGAR NEAR RABALE POLICE STATION RABALE NAVI MUMBAI THANE MAHARASHTRA 400701 | THANE | MAHARASHTRA | 400701 | - | - | Rejected-Technical Technically not Qualified |
| 5 | Rejected-Technical 12 SUBRAMANYA ARCADE BANNERGHATTA MAIN ROAD BENGALURU KARNATAKA 560029 | BENGALURU URBAN | KARNATAKA | 560029 | - | - | Rejected-Technical Technically not Qualified |
Tender Value
Refer Docs
EMD Value
₹10 L
Closing Date
28 Nov 2022, 3:00 pmClosed
Prof. Manish Agarwal
Head, Computer Service Centre, IIT Delhi, Hauz Khas, New Delhi- 110016
Appointment of an agency for Design, Site Preparation, Supply, Installation, Testing, Commissioning, Operations and Maintenance of Basic Infrastructure for the establishment of Data Centre at IIT Delhi, Sonipat Campus
2022_IIT_711231_1
IITD/COMP(SP-3960)/2022
Open Tender
Miscellaneous Services
170 days
IIT Delhi, Hauz Khas, New Delhi
As per tender documents
11 documents required · 11 mandatory
₹0
₹10 L
Yes
27 Feb 2023
8 Sept 2022
29 Nov 2022
8 Sept 2022
28 Nov 2022
8 Sept 2022
Electrical Panels and Distribution board : All floor mounted panels shall be of form 3B construction. All ACB/MCCB upto 250 A shall be thermal magnetic release and above 250A shall be microprocessor based release with Overload, short circuit and earth fault release. Supply, Installation, Testing and Commisioning of Following Panels and DB's with proper gauge MS sheet and shall comply with IS standards. All Panels should connected with earthing system.
HT tapping unit with CT, PT & DO fuse set
Distribution Transformer 2000 kVA, 11kV/433V, ∆ to Y ONAN type
HT panel
DG Control panel
LT Panel
LT Distribution panel
Floor PDU with Isolation transformer
HVAC panel
Chiller pump panel
UPS output panel
Power DB-1
500kVAr Capacitor Panel with APFCR & accessories
PAC Panel
Power DB
UPS Output DB for Non IT UPS
Light DB
Utility DB
Pump DB
Chiller ATS
Pump ATS
PAC ATS
Supply, installation, testing & commissioning of online IT UPS solution operating on 415V, 50 Hz, 3 phase input and 3 phase+N output with galvanized isolation, interconnecting suitable size copper cables between UPS & batteries,UPS input switch & UPS outgoing switch & UPS,UPS body & Body Earth,UPS neutral & neutral Earth as per actual site requirements.
Supply, installation, testing & commissioning of battery bank for IT Online UPS solution for providing end of life backup time of 10 mins & battery charger, battery stand with enclouser.
Supply, installation, testing & commissioning of online non-IT UPS operating on 415V, 50 Hz, 3 phase input and 3 phase+N output with galvanized isolation, interconnecting suitable size copper cables between UPS & batteries,UPS input switch & UPS,UPS outgoing switch & UPS,UPS body & Body Earth,UPS neutral & neutral Earth as per actual site requirements.
Supply, installation, testing & commissioning of battery bank for non-IT Online UPS for providing end of life backup time of 10 mins & battery charger, battery stand with enclouser.
Diesel genrator 1000 KVA
Supply, Erection, Testing and Commissioning of following KVA 415V, 3phase 50HZ, 4 wire Radiator cooled following rating DG set . The Diesel Engine shall be complete with necessary control and safety devices as per IS/ BS specifications. The Engine shall be suitable for continuous operation of Generator duty, inclusive of Flywheel, flexible coupling, air cleaner, corrosion resistor, Radiator, fan with guard, Fuel pump,fuel filter, Electronic governor, starting system with separate Battery charger with 2nos 24Vsealed Maintenance Free Batteries, Voltage regulator, Instrument panel with RPM Indicator, Exhaust silencer(residential), protections against Low Lub. Oil pressure, high water temperature with required supports, brackets and clamps, battery stand, anti vibration pads and first filling of lubricating oil and fuel oil for set. The Alternator shall be suitable for415V 3phase, 4wire, 50HZ AC supply operation and shall be able to deliver full load current at 100% Unbalance load. The set shall be supplied with acoustic enclosure as per CPCB norms.
Supply of exhaust piping of following sizes MS B Class exhaust pipes conforming to IS:3589 with welding joint including bends, clamps, dash fastener, flanges, nuts, bolts etc. complete requirement suitable for 1010 KVA DG's with aviation light & required accessories.
Electrical Cables: (a) Effecting proper and adequate connections at terminations. (b) Ensuring that provision is left in building components and trenches as the work proceeds for incorporation of cable supports at a later date. (c) Providing all fixing accessories such as clamping devices, Tie's, nuts and bolts, screws where laid in trenches or trays.(Not to consider Trays and Trenches rates, it will be paid Seperatly) (d) Providing proper supports for cable terminal boxes . (e) Providing heavy duty copper lugs, insulation tape etc. at joints and terminations. (f) All fixing accessories such as GI saddles, screws, raw plugs, suitable size Anchor Fasteners etc. (g)Cutting chases, holes and making good the same wherever required. (Not Valid for any Concrete Slab) (h)Testing of the Cables in the Manufactures works and providing test certificates with the handover documents is the sole responsibility of the Contractor.
3C x 300 Sq mm AL Arm XLPE, 11 KV HT Cable (Length upto)
4C x 300 Sq mm AL Arm XLPE, 440V LT Cable (Length upto)
4C x 240 Sq mm AL Arm XLPE, 440V LT Cable (Length upto)
1C x 120 Sq mm Cu Arm FRLS, 440V LT Cable (Length upto)
4C x 70 Sq mm AL Arm FRLS, 440V LT Cable (Length upto)
4C x 50 Sq mm Cu Arm FRLS, 440V LT Cable (Length upto)
4C x 40 Sq mm AL Arm FRLS, 440V LT Cable (Length upto)
4C x 10 Sq mm Al Arm FRLS, 440V LT Cable (Length upto)
1C x 10 Sq mm Cu Flexible, 440V LT Cable (Length upto)
1C x 2.5 Sq mm Cu Flexible, 440V LT wire RYB for point wiring (Length upto)
1C x 1.5 Sq mm Cu Flexible, 440V LT wire RYB for point wiring (Length upto)
Terminations for Cable
3C x 300 Sq mm AL Arm XLPE, 11 KV HT
4C x 300 Sq mm AL Arm XLPE, 440V LT
4C x 240 Sq mm AL Arm XLPE, 440V LT
1C x 120 Sq mm Cu Arm FRLS, 440V LT
4C x 70 Sq mm AL Arm FRLS, 440V LT
4C x 50 Sq mm Cu Arm FRLS, 440V LT
4C x 40 Sq mm AL Arm FRLS, 440V LT
4C x 10 Sq mm Al Arm FRLS, 440V LT
Bus-bar trunking (BBT) (a) Supplying, installation, testing and commissioning of continuous access copper conductor track busway system, Indoor type application having IP3X rating, insulation, suitable for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply with aluminium housing, maintenance free system, necessary joints & expansion joints, provision of tapping the plug in box without deenergize the busbar, including all the necessary components like clamping brackets/ suspenders, fasteners, accessoris for mounting screws, complete as required. Bolting and tourqing should not be accepted. (b) Note : The Bends & Joints shall not be measured separately, and shall be considered as straight pieces & measured along the centre line of BBT
800A,415V TP+2N Cu.Continuous access busbar
End Feed Unit Standard lugs, Large box with CPM Standard Left Lid, Reverse unit
End Caps
Housing Coupler
Hanger Bolt
Closure strip, 3 mtr per length
Supply, Installation, Testing & commissioning of following powder coated Tap OFF Boxes with IP 55 rating complete as per technical specifications, relevant standards, and direction of Engineer in charge. Tap off Unit with 63A, 415V TP+N MCB, D curve industrial type 5pin plug & socket of 2 Nos- 63A, 415V AC suitable for bus trunking system.
Cable Tray : (a) Supply and Installation with all nescessary supports and hardware. (b) The work should be carreid out as specified in the specification sheet. (c) Colour of the Trays has to be confirmed by the customer.
100mm x 1000 mm wide perforated Type Cable Tray
50mm x 600 mm wide perforated Type Cable Tray
50mm x 300 mm wide perforated Type Cable Tray
50mm x 450 mm wide Basket Type Cable Tray
50mm x 150 mm wide Basket Type Cable Tray
Earthing and earthing strips : (a) All earth pits shall be as per IS 3043 with latest amendments. (b) Earthing stations should contain relevant grade of charcoal/coke and salt packed around the earth plate/earth pipe as called for in the item. (c) Earthing shall be done at indicted location by the Consultants. The minimum distance between the two earth station shall be 3 meters and that from the building is 2500 mm. (d) An earth ring with relevant earth test terminal boxes shall to be provided at regular intervals. (e) Adequate number of earth strips with proper sized holes shall be provided for extending earthing/looping earth connections at various floors shall be provided and executed as per the requirement. (f) The Contractor has to provide heavy duty Cover of size 450 x 450 x 8 mm thick to the Earthing Chamber. (g) The cover is to be sand blasted and then Powder coated using Matt Jet Black Colour. The Cover is to be fabricated using 8 mm thick Chequered Plate.
Chemical Earthpits / Maintenance free Earthpits having better Earth Resistance value. This shall be for Data Centre including UPS. Bidder to make sure to achieve required earth resistance of < 1 Ohm.
6 sqmm green cable
25 x 3 copper Strip for Earthing of panel & DC LU grid
50 x 6 copper Strip for Earthing of panel
50 x 6 GI Strip for Earthing of panel
75 x 10 GI Strip for Earthing of panel
1c x 185 sqmm cu flexible (Green Colour)
Termination of 1c x 185 sqmm cu flexible (Green Colour)
Dedicated Earthing Box with 50mm x 10mm x 200mm Length,Tinned copper strip with 16mm holes
150x150x3mm Danger Notice Board & 415 Enameled Danger Board
150x150x3mm Danger Notice Board & 11kV Enameled Danger Board
1000 x 1000 mm wide 2.5mm thick Rubber Matting suitable for 1100 Grade
Light and Power point Wiring
Modular switch board with switches and sockets for wall
Modular switch board with switches and sockets for Desk
MS Conduit with accessories
PVC conduit with accessories
Smart LED Lights Square 2'x2'
Smart LED lights Square 1'x1'
Occupancy sensor range 6-7 meter
Flexible MS conduit
Flexible PVC conduit
BMS system
SITC of GUI based Building Managament software application
Rack Server with windows server OS, storage space required for log & audit history data and all required accessories
PC for Client work station with all accessories and windows OS
DDC Panel
SITC of supervisory controllers with accessories & power supplies
SITC of field level direct digital controllers with accessories & power supplies
Temperature & Humidity sensors
24 port Network Switch 100/1000 BASE-T
SITC of 2C*1.5 sqmm sheathed flexible cable with all accessories
SITC of 25 mm PVC conduits and complete related accessories
DCIM System
DCIM software
Field Controler and convertors with accessories
Power Supply unit 24 VDC 5 Amp
Power Supply unit 12 VDC 5 Amp
Networking cable
Network switches
Sensors
PC with accessories for DCIM system
Fire Alarm System & Fire Extinghuishers
Intelligent Addressable Fire Alarm Control panel with 2 Loop Capacity expandable up to 2 loops in future. The panel shall consisting with 80 character LCD display and RS 485 for networking. Each Loop should have the capacity to cater to 125 devices and 125 detectors per Loop. The vendor shall consider the necessary (if required) interface modules, integrators etc and all module necessary for successful operation and BMS integration of the complete system as per the site requirement.
Detector (multicriterion)
Heat Detector
Manual Call Point
Control Modulte/ relay module
Fault isolator Module
Monitor Module
Hooter
2 Core 1.5sq.mm armored cable
Response Indicator
Batteries for FAS panel
Fire extinguisher 2 Kg ABC type
Fire extinguisher 4 Kg DCP type
Fire extinguisher 4.5 Kg corbon dia-oxide (CO2) type
Related all other accessories to complete the solution
Access control system
Access Software Application with a client license
Electro Magnetic Lock (600Lbs)
Electro Magnetic Lock (1200Lbs)
Access Reader (Mifare cards)
Access Card compatible with Access reader (Mifare)
2 door/ 4 Reader Access controller with power supplies
Push Button
Emergency Door Release Switch
5 Amp 12V Power Supply
10 Amp 12V DC Power Supply
4 Core 1sq.mm. (Sheathed Cable)
8 Core 1sq.mm. (Sheathed Cable)
Network Cat 6 Cable
Rack Server with windows server operating system and MS-SQL server for access software application
Water leak detection system
4/6 Zone WLD Pannel for Server farm area and UPS room with BMS integration feature.
Water Leak Sening Cable with end connections
Alarm modules for constantly monitoring the cable and sends the alarm to panel.
Termination caps
PVC Junction Box
2 x 1 sq mm sc Un Armoured Cable for BMS integration
PVC Conduit 25mm including all fittings.
Very early smoke detection system
Aspirating Smoke Detection Unit with 2 tube inlets capable of LED indicator bar 3 relay output, single detector chamber, smoke detector sensitivity range 0.025 - 2.00% obs/m (0.008 - 0.625% obs/ft). - for Server Farm Area and UPS room
Capillary Tube with accessories
Sampling Point for Capillary tube end & label
Power Supply unit 24 VDC 5 Amp
PVC Conduit including all fittings 25mm/1 inch
Gas based suppression system
80 Litre Seamless Cylinder PESO/ CCOE Approved, complete with valve assembly and a pressure gauge with a safety burst disc and a safety cap.
Novec 1230/ FK-5112 Agent per KG
Electric Cum Manual Actuator
Pneumatic Actuator
Discharge Hose
Actuation Hose
Warning Sign Plate
Discharge Nozzle
Manifold Check Valve
M S Container Strap
Manifold fabricated from seamless pipe Pipe (S) : M.S. Seamless To ASTM A-106, SCH. 80
C.S./M.S. Seamless Piping, fittings (forged screwed/socket weld upto 50NB) & M.S. supports e.g. angle, channel, plates clamps, etc. As per ASTM A-106, SCH. 40.
Gas release 4 zone panel
Gas based suppression system
Software (RRS)
Rodent Repellent Controller
Satellite Transducer
Cables for connectivity between transducer & Controller
PVC Junction Box
PVC Conduit 25 mm including all fittings
Brackets MS Power Coated
PC or workstation with complete accessories for RRS monitoring application
230KW, 415 V, 3 phase, monitor level intelligent PDU
CCTV Solution
IP Dome Camera (Onvif Profile S&G Compliantwith all accessories)
IP Bullet Camera (Onvif Profile S&G Compliant with all accessories)
Video Mangement Software (with 25 Camera License)
POE Switch 24 Port
POE Switch 8 Port
Cat 6 Cable with RJ 45 Connectors
PC System With 43"inch LCD Monitor & all required accessories (For Client)
Rack Server (For VMS With Latest window server operating system Data Center Edition)
100 TB NAS Storage (with all accessories)
HDMI Cable (5 meter)
UPVC pipe 25 mm
PA system
Amplifier 75 Watt x 220Volt
Goose Neck Microphone Table Type With ON/OFF Button With Base/Stand.
Wall Speaker 60 Watt
Ceiling Speaker 40 Watt
2 Core 1.5 sq.mm Armored Cable
25 mm MS Condute ISI Mark
HVAC High & Low side
Air cooled Chiller of 53 Tr capacity
Chiller Plant manger software with controllers, cables PC & related accessories
Chiller low side work with pumps and realeted accessories
Direct expansion microprocessor based Precision A/C units (30 Tr)
PAC Low Side Work
Comfirt air conditioners (5.5 Tr ductable/VRV as per requirement)
CAC Low side work
Cold aisle containment
Fire exhuast system with dampers for server farm
Exhuast frills with dampers form electrical rooms
RDHX with accessories
Racks with accessories
Civil work
HT & LT room creation
Transformer foundation & releted work
Road crossing work
Server farm work
LT room work
DG foundation
Fuel storage & HSD tank
Chiller platform and related work
Tranches
Work stations for BMS & NOC room
Any other item required to make the package/work complete (Bidder has to specify item wise)
Project Monitoring ,Management & Documentation
Kyndryl Solutions Private Limited
PRASA INFOCOM AND POWER SOLUTIONS P LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid