Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC AT PO URIMARI DISTT HAZARIBAGH JHARKHAND PIN 825311 | URIMARI | HAZARIBAGH | JHARKHAND | 825311 | L1 | Accepted-AOC L1 | |
| 2 | L2₹4.1 L+₹84,577.20 (25.9%)Rejected-Finance | L2 | Rejected-Finance Not techno-commercially eligible | |
| 3 | Rejected-Technical | - | Rejected-Technical Not technically eligible | |
| 4 | Rejected-Technical BANK COLONY PATRAPALI BASTI RAMGARH JHARKHAND 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | - | Rejected-Technical Not technically eligible |
Tender Value
₹4.6 L
EMD Value
₹5,700
Closing Date
23 Nov 2024, 11:00 amClosed
PE (EnM) GIDI C
Office of Project Officer, Gidi-C
Erection of poles, drawing of conductor and earth wire of 3.3 KV Overhead line at extension at satkaria coal face of Gidi C Colliery under Argada Area.
2024_CCL_321051_1
PE(EnM)/GDC/eNIT/2024-25/14 Date 13.11.2024
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Gidi-C OCP
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,700
22 May 2025
13 Nov 2024
25 Nov 2024
13 Nov 2024
23 Nov 2024
14 Nov 2024
14 Nov 2024 - 21 Nov 2024
Amount
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. Above 11.00 metre and upto 13.00 metre.
Supply and erection of stay set complete (galvanished) with 19/20mm dia. X 1.9 mtr. Long stay rod anchore plate of size 45cm X 45cm X7.5 mm ,thimble stay clamps,bow tightner, 7/4.00 mmdia GI stay wire and insulator etc. in cement concrete 1:3:6 (1 cement : 3 corses sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required
Erection of all AASC conductor of 7/3.35 mm to 7/4.00 mm diameter and above including binding etc. as required. (3 wire X 50 Mtr X 100 = 1.50 km X 342.51 kg/km)
Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanished insulator fittings,ball and socket type and complete with galvanised strain clamps,bolts,nuts,washer etc. as required
Supply and erection of 11 KV pin insulator complete with large steel head GI pin, nut, washer etc. as required
Supply of 8 SWG G.I wire
Erection of G.I wires No- 8 SWG including binding etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/cross arm for single 11 KV over head line conductor complete with 50 mm X 6 mm flat iron clamp,bolts,nuts and washers including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm(Angle iron bracket welded to the channel iron and complete with 50 mm X 6 mm M.S Flat iron clamps,bolts and nuts including drilling holes for insulator pins,bolts,nuts and washers etc and painting with primer and finish paint as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm(7.14 kg per metre) cross arm for 4 wire over head line complete with clamps,bolts and nuts and washers etc including drilling of holes for insulator pins etc and painting with primer and finished paint as required.
Erection of pole top/straight two wire/V shape two wire,angle iron/channel iron,cross arm on steel tubular / rail /PCC pole for 11 KV as required
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying of two length channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arm together ,including drilling holes for insulator pins/fittings,bolts, nuts and washers etc(as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11 KV over head line as required.
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height ,complete with 50mm X 6 mm M.S flats iron clamps, bolts and nuts including drilling holes for insulator pins,bolts and nuts etc and painting with primer and paint as required
Dismantling of Pole/Street Light Standard/Strut embeded in cement concrete foundation etc. as required.
Dismantling of Over Head Lines comprising of copper/aluminium over head conductor,GI wire,Cross arms,Iinsulators etc as required.
R23 RADIANT ENERGY (BID ID -1102976)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .