Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC 24 | PRAYAGRAJ | UTTAR PRADESH | 211001 | ₹1.1 Cr | L1 | Accepted-AOC Accepted being lowest. |
| 2 | L2₹1.4 Cr+₹27.2 L (24.5%)Rejected-AOC | ₹1.4 Cr+₹27.2 L (24.5%) | L2 | Rejected-AOC Rejected not being lowest. |
Tender Value
₹1.2 Cr
EMD Value
₹2.0 L
Closing Date
30 Sept 2022, 6:00 pmClosed
CWE No 2 Meerut
Headquarters Commander Works Engineer No 2 Military Engineer Services Boundary Road, Near Supply Depot Meerut Cantt-250001
WIDENING OF CERTAIN ROAD AT ROORKEE UNDER GE ROORKEE
2022_MES_547691_1
95185/RKE/E8
Open Tender
Civil Works
Item Rate
270 days
GE Roorkee
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE Roorkee
₹2.0 L
8 Dec 2022
25 Aug 2022
7 Oct 2022
25 Aug 2022
30 Sept 2022
15 Sept 2022
Amount
Repair to potholes of depth exc 30cm not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth and making good by applying tack coat @ 5 kg per 10 sq m, putting in premixed bituminous macadam, well rammed and sealed with binder 9.8 kg per 10 sq m, blinded with 0.09 cu m of stone chippings, 6.3 mm size and again well rammed (including supply of premixed, macadam, binder & chippings) complete all as specified and directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out soft/loose complete all as specified and as directed.
Add to (or deduct from) item No 02 above for every 3cm or part there of above or below 15cm average depth.
Rolling and Consolidating formation surfaces in cutting by using power roller exc 8 tonne & n.exc 12 tonne complete all as specified and as directed.
M&L for Soling (or sub base) spread thickness 150mm with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and as directed.
M&L for 150 MM thick (75mm, thick each in two layers) (compacted thickness) WBM, with coarse aggregates of grading 2 (63 to40mm size)or of grading 3 (50 to 20mm size), quartzite spread, rolled and consolidated to gradient and camber required complete all as specified and as directed. Note for Item No 4,5 & 6:- Wherever width of road is restricted and power roller can't use then the compaction to be done using vibrating roller not less than 3.0 tonne.
Preparing Unsurfced WBM surfaces by brushing with wire brushes for removing caked mud etc. swe- eping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and as directed.
M&L for Applying evenly a priming/tack coat with bitumious primer of paving bitumen content (VG-10) @ 10 Kg per 10 Sqm of cleaned dry surface by a self propelled or bitumen pressure sprayer equipped for spraying the tack coat uniformlyr complete all as specified and as directed.
M & L for premix bituminous macadam laid/ rolled and compacted to required gradient and camber with Paving bitumen VG-10 blinder content of 4% by weight of total mix (consolidated thickness 75 mm or less) complete all as specified and as directed. Note:- Wherever width of road is restricted and power roller can't use then the compaction to be done using vibrating roller not less than 3.0 tonne.
M&L Preparing black top surfaces by brushing with wire brushes for removing caked mud etc. swe- eping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and as directed.
M&L for Applying evenly a priming/tack coat with bitumious primer of paving bitumen content (VG-10) @ 5 Kg per 10 Sqm of cleaned dry surface by a self propelled or bitumen pressure sprayer equipped for spraying the tack coat uniformly complete all as specified and as directed.
M&L for Bituminous premixed semi dense asphaltic concrete 30 mm thick (consolidated thickness) with 5.5% binder content ( VG-10) by weight of total mix, rolled with power roller exc 8 tonne & n.exc 12 tonne and compacted to required camber and gradient complete all as specified and as directed.
M&L for thermoplastic reflective paint as in road marking 2 mm thick single coat as in centre line or edge line road marking of 100/150 mm width using HOT MARK thermoplastic paint ( Hot application) white by indigeneous modern propelled raod marking machine as directed including all ingredients such as binder glass beads Titanium-diaoxide calcium carbonate lintar fillers thermoplastic requirement for glass beads shall be as per the table No. 800-4 specification including spraying of glass beads instrucions complete all as specified and as directed. Note: Make of paint STP, ASIAN or equivalent as approved by GE
Supply and fixing in repair cat eye solar reflective type of metal body alloy of size 100mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions.( Green/Yellow/Red colour)complete all as specified and as directed. Make:- (a) Future Vista Mumbai, item code 38239027. (b) Jiva Engineering Company, New Delhi, item code 78639603. (c) Industrial Handware Centre, New Delhi Item code 130784281.
Supply and fixing in repair metal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PAMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height above graund and 200mm below ground duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 complete all as specified and as directed. Make:- 3M/Dark eye
M&L for pre cast cement concrete Type B1 1:2:4 ( 20mm graded stone aggregate ) as in kerb stone set and jointed in cement mortar 1:4complete all as specified and as directed. Note:- Earth filling for back side filling of Kerb stone shall be used by earth obtained from surface excavation. Rate quoted is inclusive of back filling and levelling.
Removing excavated soil material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed.
M&L PCC 1:3:6 type C-1 (Using 40 mm graded stone aggregate) as in surface channel & drainh complete all as specified and as directed.
S&F in repair 110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints laid in ground/ foot path for rainwater drainage as rain water pipe and similar work including taking down old existing pipe complete all as sepcified and directed.
M&L for Concrete in PCC 1:3:6 type C2 bed to drain pipes including packing under for PVC pipe of dia 110mm and completely surrounding pipes with concrete after they are laid and tested complete all as specified and as directed.
Dismantling of steel LT poles 9.0 long including disconecting of cross arm and insulators complete for re-use from its original position incl Excavation and demolition of PCC work etc complete all as specified and as directed.
Dismantling of RCC / damaged Steel LT poles 9.0 long complete from its original position including disconecting of cross arm and insulators for depositing in store / giving credit to the tenderer complete all as specified and as directed.
Fixing only dismentalled old steel tubular Street light pole 9.0 meter long retrieved against Item No-21 and shifting & re installing it to new location as required on site complete all as specified and as directed. Note :- Excavation, MS work and PCC work will be measured and paid separately.
Supply & Fixing new steel tubular poles complete with cast iron base plate, final taper, plug, bolts, nuts & washers as specified type 410 SP-31 (9.0 mtr long) including painting two coats of aluminium paint on exposed surfaces to steel tubular pole of 9.0 mtr including crossarms, Bracket etc including 5 Nos. of strip / bands painted with postoffice red and nevy blue colour (300 mm each) in alternate layer from coaping, marking of pole number with black synthetic enamel paint 2.5 cm height including in 6" dia circle etc complete all as specified and as directed.
M&L for PCC work type D-2 (1:4:8) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etch complete all as specified and as directed
M&L for PCC work type C-2 (1:3:6) with 40mm graded aggregate for foundation to poles / stays/strutus or basements etc complete all as specified and as directed.
M & L for PCC work type B-1(1:2:4) with 20 mm graded aggregate for coping ( new and old damage coping) to poles / stays/strutus or basements etc complete all as specified and as directed.
Taking down rusted/unsv mild steel work and M&L for mild steel work as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and as directed.
Dismantling of ACSR or AAC conductorscomplete all as specified and as directed.
Dismantling insulators any type, any size complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and as directed Make : Havels/ KEI/Dynamic/ Poloy Cab/Rhino.
All as per Item No-31 above but of size 35 Sqmm 3.5 Core complete all as specified and as directed.
All as per Item No-31 above but of size 25 Sqmm 4 Core complete all as specified and as directed.
All as per Item No-31 above but of size 16 Sqmm 4 Core complete all as specified and as directed.
All as per Item No-31 above but of size 10 Sqmm 2 Core complete all as specified and as directed.
Excavation in trenches/post holes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for laying of pipes and for poles/stay and struts not exceeding 10 Sqm on plan and getting out, excavated earth, forming bottom surfaces to required level complete all as specified and as directed.
All as per Item No- 36 above but exceeding 1.5 meter in depth but not exceeding 3.0 meter in depth for erraction of pole complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil complete all as specified and as directed.
Removing surplus spoil to a distance not exceeding 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and as directed.
Supply and laying sand river for cushioning with layers of sand 8 cm before lying of cable and 15 cm after lying of cable (total 23 cm) in trenches complete all as specified and as directed. Note: Thickness after punning shall be measured for payment. (18 cm Punned thickness)
Supply and laying brick protection cable cover using sub class ‘B’ bricks laid flat adjacent to each other across the length of cable laid dry complete all as specified and as directed.
Supply & fix PVC Junction box of size 350x250x150 mm with Aluminium bus bars 04 Nos fixed on pole with the help of MS nuts bolts and MS clamps-2 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including provn of cable glands for incoming and outgoing cables complete all as specified and as directed. Make Syntix/ Hensel/ Napture.
Supply & fix PVC Junction box of size 250x200x105 mm with Aluminium bus bars 02 Nos fixed on pole with the help of MS nuts bolts and MS clamps-1 Nos of size 40mm X 5mm thick with one No MCB SP 6 Amp capacity includes making suitable hole on pole to take out connections to fitting if required at site and PVC insulated sheathed multistranded copper conductor 3 core 1.5 Sqmm for making connection from junction box to security light fitting complete including provn of cable glands for incoming and outgoing cables complete all as specified and as directed. Make :- Syntey/Hensel/Napturee.
Supply and fix LED Street Light Luminaire 60 Watt with pressure die cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP65 protection including brackets made out of GI pipe light grade of suitable dia or as per manufaturere recommonded, 1.2 Mtrs long, bent to shape incl 02 Nos MS flat clamps, nut bolts, termination complete all as specified and as directed.
S &F galvanized iron pipe of 50 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc complete all as specified and as directed.
S &F galvanized iron pipe of 40 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc complete all as specified and as directed.
S &F galvanized iron pipe of 32 mm bore light grade in trenches / road / nallah or fixed along wall/ pole including mild steel clamps, screws etc complete all as specified and as directed.
M & L for Stay assembly complete with accessories as shown in electrical plate No. 1 including 16 mm dia rod and loop type insulator, stay wite 7/16 mm, clamps, etc complete all as specified and as directed.
M & L for Horizontal Boring of holes under road, pavement, hard standing by trenchless technology using GI Pipe of required dia and necessary machine suitable for 0.4 mpa working pressure complete all as specified and as directed. Notes: GI pipe medium / Light grade will be measeured and paid saperately under respected item.
S & F street light timer panel suitable for three phase supply including astronomical digital timer, contactor three phase, MCB TPN 63 amos for incomer and outgoing for overload and short circuit protection, 63 Amp, 440 Volt complete all as specified and as directed. Make : Havells or equntet model in Legrand/ ABB.
S & F Street light timer panel suitable for single phase supply including astronomical digital timer, contactor single phase, MCB SPN 40 amos for incomer and outgoing for overload and short circuit protection, 40 Amp, 240 Volt complete all as sepcified and directed. Make : Havells or equivalent model in Legrand/ ABB.
M&L earthing complete with galvanized steel plate electrode 600 mm x 600 mm x 6 mm thick, burried directly in ground earth pit not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level and covered surrounded from all sides with mixture of charcoal and common salt in alternate layers upto 15cm above top of plate and electrode connected to galvanized iron wire 4 mm dia by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 20 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 15 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, 50mm thick RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 10 cm c/c both way for cover and MS frame etc., complete all as specified. Note: The unit rate includes earth strip and protection pipe upto (maximum 7.5 metre from earth plate) earth point/test point.
sagar associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .