CWE (AF) Borjhar
HQ CWE (AF) Borjhar Military Engineer Services PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele 0361 2841626
CERTAIN REPAIR TO AC AND REFRIGERATOR SYSTEM AT AF STN TEZPUR UNDER GE(AF) TEZPUR
2023_MES_607011_1
CWE(AF)/TEZ/TOKEN-12 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Tezpur
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Tezpur
₹80,000
25 Aug 2023
30 Jun 2023
4 Aug 2023
30 Jun 2023
31 Jul 2023
17 Jul 2023
Amount
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Package type air cooled AC plant of capacity 3x5.5 TR, by cleaning of airfilters, condensor cleaning with coil cleaner, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring,greasing of blower motor, checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results,in presence of Engineer-in-Charge, complete all as specified and directed. [Package type air cooled AC plant of capacity 3x5.5 TR,Model – DPA1052R2 (Make:Bluestar) installed in Transmitter Building].
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Package type air cooled AC plant of capacity 2x8.75 TR by cleaning of airfilters,condensor cleaning with coil cleaner,cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring, greasing of blower motor,checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site, including test run for 24 hrs to achieve satisfactory service and designed condition test results, in presence of Engineer-in-Charge complete all as specified and directed. [Package type air cooled AC plant of capacity 2x8.75 TR,Model – DPA661R2 (Make:Bluestar) installed in Parachute Building].
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Package type air cooled AC plant of capacity 6x16.5 TR by cleaning of airfilters, condensor cleaning with coil cleaner, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring, greasing of blower motor, checking of all safety measures,topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site including test run for 24 hrs to achieve satisfactory service and designed condition test results in presence of Engineer-in-Charge, complete all as specified and directed. [Package type air cooled AC plant of capacity 6x16.5 TR Model – DPA1983R2 (Make:Bluestar) installed in MPR Building ].
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Package type air cooled AC plant of capacity 3x11 TR by cleaning of airfilters, condensor cleaning with coil cleaner, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring, greasing of blower motor,checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site including test run for 24 hrs to achieve satisfactory service and designed condition test results in presence of Engineer-in-Charge complete all as specified and directed. [Package type air cooled AC plant of capacity 3x11 TR Model – DPA1322R2 (Make:Bluestar) installed in PTT Building (Stimulator)]
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of floor mounted Package type air cooled AC plant of capacity 3x11 TR Model – DPA1322R2 by cleaning of airfilters, condensor cleaning with coil cleaner,cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring (cost of control wiring included), greasing of blower motor in quote rate, checking of all safety measures, topping of required refrigerant gas and compressor oil it retained as required, balancing of blower etc and including repair/replacement of unserviceable spare parts as and when required i.e compressor of the package unit, micro processor control unit, indoor blower motor, outdoor fan motor, fan motor blade, condensor coils, airfilters, dampers, liquid line gas filter, charging valve, contractors, blower motor bearing, required size V-belts, leak test by nitrogen gas and charging the refrigerant as required at site including test run for 24 hrs to achieve satisfactory service and designed condition test results in presence of Engineer-in-Charge complete all as specified and directed. [Package type air cooled AC plant of capacity 3x11 TR Model – DPA1322R2 (Make:Bluestar) installed in Base OPS Building].
Preventive and comprehensive maintenance as per Original Equipment Manufacturer's (OEMs) reccommendations of central AC chiller plant of capacity 2x52 TR, water cooled screw chiller type by checking the functioning of Chiller unit/Air Handling unit/ Pumps /Cooling tower/Controls and all such equipment covered installed, Descaling of condensers/ chemical cleaning of evaporator coils/replacement of pre filters based as per requirement, descaling of cooling tower and replenishing as required refrigerant gas and compressor oil in the system as per requirement respectively, servicing/replacing and descaling of chiller plant any type of spare parts of chiller unit as and when required related to compressors, thermostat, cut outs, micro processor unit control modules of the plant, control boards, pressure transducer, sensors, capacity transducer, phase protector, timer, chillers/condensing unit water cooled screw chiller compressors, evaporators, expansion valves, water cooled condensers, oil cooler, oil pipings, oil filters, refrigerant pipings, refrigerant filters, solenoid and automatic control valves, cooling tower nozzle, condensor water pump with motors, electrical control wiring and including coil changing, cleaning of AHU drain, AHU V belts, replacement of hessian cloth with chain,heat varnishing, baking,connecting plates,checking of all electrical connections (removing of carbon deposits if any), pre-filter and micro filrter cleaning,greasing of all bearings etc.,complete with the following all as specified and directed. [Water cooled screw chiller type Model – XWC4S-052AR2 – 2 x 52 TR (Make:Bluestar) installed in HK Bose Building]. Note: Please refer NOTES on Annexure to BOQ for serial item No 01 to 06 enclosed with tender documents.
Supply and Fix in repair, 40 Amps,4 pole,open bakelite terminal block connector,complete all as specified and directed.
Supply and Fix in repair 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 18, AC-3 rating 18 Amps and AC-1 rating 30 Amps,complete all as specified and directed. [Cat No.CS94100/CS94101 of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB]
Supply and Fix in repair 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type MNX 32, AC-3 rating 32 Amps and AC-1 rating 55 Amps,complete all as specified and directed. [Cat No.CS94111 of Make “L&T” or equivalent Model of Make Siemens/ Schneider / ABB]
Supply and Fix in repair, 3 pole power contactors conforming to IS / IEC 60947-4-1 & IEC 60947-4-1, Type ML 3, AC-3 rating 40 Amps and AC-1 rating 45 Amps,auxillary contacts 2 NO + 2 NC,complete all as specified. [Cat No.SS90721 of Make “L&T” or equivalent Model of Make Siemens/Schneider/ ABB.]
Supply and Fix in repairs, panel mounted protection device for,single phasing preventor ,complete all as specified and directed. [Cat No. VSP3 of Make Minilec or equivalent Model of Make L&T/ Seimens]
Supply and Fix in repair,thermal overload relay,Type MN - suitable for MNX contactor, with built-in single phasing protection,manual and auto reset mode,type of mounting (Operation) MN 2 (Directly Operated), relay range 9 to 15 Amps,complete all as specified and directed. [Cat No.SS94142OOBO of Make “L&T” or equivalent Model of Make Legrand/ Hager/Seimens /GE/ Schneider/ABB.]
Supply and Fix in repair,Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 63 Amps and 18 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In, complete all as specified and directed. [Cat No.CM90518OOHO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repair,Moulded case circuit breakers (MCCBs),conforming to IEC 60947-2& IEC 60947-2, AC 415V, 4 pole, with current rating 100 Amps and 25 KA breaking capacity Icu at 415V, AC, 50Hz, with adjustable Over Load setting: 0.8 - 1.0 x In and adjustable Short Circuit setting: 6-10 x In.complete all as specified and directed. [Cat No.CM90642OOLO of Make “L&T” or equivalent Model of Make Siemens/ Legrand / ABB.]
Supply and Fix in repair,miniature circuit breaker (MCBs) single pole and neutral,C curve, 240 Volts,10KA, 6 to 32 Amps,complete all as specified and directed. [Cat No. BB20060C/BB20100C/BB20160C/BB20200C/BB20250C/BB20320C of Make L&T or equivalent Model of Make Legrand/ Hager/Seimens/GE/ Schneider/ABB]
Supply and Fix in repair,Miniature Circuit Breaker (MCBs) triple pole & neutral,C curve,415 Volts, 10KA, 63 Amps.,complete all as specified and directed. [Cat No.BB40630C of Make L&T or equivalent Model of Make Legrand/ Hager/Seimens/GE/ Schneider/ABB]
M/L for Disconnection of existing Control Panel, form all incoming and outgoing electrical connections, repair to internal wiring / burnt out wiring of LT panel and supply and rewiring with suitable size upto 6 Sqmm single core PVC insulated FRLSH , unsheathed multi stranded 1100 volts grade copper conductor cable up to 20 RM from bus bar to outgoing feeders/ starters including replacement of defective lugs,thimbles etc properly lugged at end terminals , and through cleaning of panel both internally and externally, re interconnection of parts including reconnection of all incoming and outgoing electrical connections after repairs,testing and commissioning,complete all as specified and directed.
Supply Only, digital hygro thermometer,with clock, temperature and humidity display,temperature range 10 ~ 60°C / (14 ~ 140°F) accuracy ± 1°C / (± 1.8°F),temperature resolution : 0.1°C / °F, humidity range 20% RH ~ 95 % RH,humidity resolution 1 % RH accuracy 8% RH,complete all as specified and directed. [Model KM 918A of Make Kusam-MECO or equivalent Model of Make HTC/Mextech]
De-Scaling of Condensers of capacity 26 TRX 3 Units installed at Signal Section by using dilute de-scaling agents, filling it for 24 Hours, removing the scalings by mechanical wire brush after opening the side plates,cleaning throughly including replacement of gaskets, refixing the end plates,complete all as specified and directed.
De-Scaling of Condensers of capacity 26 TRX 2 Units installed at CRRW by using dilute de-scaling agents, filling it for 24 Hours, removing the scalings by Mechanical wire brush after opening the side plates,cleaning throughly including replacement of gaskets, refixing the end plates complete plant all as specified and directed.
Overhauling of Air-Handling Unit of AC Plant of capacity 26 TR x 2 installed at CRRW including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat varnishing, baking,connecting plates, checking of all electrical connections (removing of carbon deposits if any), pre-filter and micro filter cleaning and greasing of bearings, AHU V Belts, thermostat & humdistate,complete all as specified and as directed.
Overhauling of Air-Handling Unit of AC Plant of capacity 26 TR x 3 installed at Signal Section including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat vernishing, baking, connecting plates, checking of all electrical connections (removing carbon depositsif any), pre-filter and micro filter cleaning, greasing of bearings, AHU V Belts, thermostat & humdistate,complete all as specified and as directed.
Disconnecting defective Condensor pump of capacity 2.0 HP, 3 Phase, transporting to OEM's service centre for checking,segregating serviceable and unserviceable parts, cleaning the serviceable parts viz.stator,rotor, terminal box,bearings,shaft, key etc. thoroughly as per OEM's reccommendations,replacement of unserviceable parts and refixing the pump in original position,reconnecton including testing on full load and commissioning,complete all as specified and directed. Note :- Spares parts for replacement will be measured and paid separately under respective items of this BOQ.
Disconnecting existing defective Chiller pump of capacity 3 HP, 3 Phase, transporting to OEM's service centre for checking,segregating serviceable and unserviceable parts, cleaning the serviceable parts viz.stator, rotor, terminal box,bearings,shaft, key etc. thoroughly as per OEM's reccommendations,replacement of unserviceable parts and refixing the pump in original position,reconnecton including testing on full load and commissioning,complete all as specified and directed. Note :- Spares parts for replacement will be measured and paid separately under respective items of this BOQ.
Disconnecting defective Chiller pump of capacity 5 HP, 3 Phase, transporting to OEM's service centre for checking,segregating serviceable and unserviceable parts, cleaning the serviceable parts viz.stator, rotor, terminal box,bearings,shaft, key etc. thoroughly as per OEM's reccommendations,replacement of unserviceable parts and refixing the pump in original position,reconnecton including testing on full load and commissioning,complete all as specified and directed. Note :- Spares parts for replacement will be measured and paid separately under respective items of this BOQ.
Disconnecting defective water pump motor, transporting to OEM's service centre for checking, dismantaling of parts,removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor motor of capacity 2.0 HP, Three Phase, 230 V, 50 Hz, with super enamelled copper wires of existing size/gauge including provision of all insulating materials and varnishing,lubrication of bearing / bushes using fresh lubricant all as per OEM's reccommendations, replacement of defective parts,re-assembling, including testing and commissioning,complete all as specified and directed. Note :- Spares parts for replacement will be measured and paid separately under respective items of this BOQ.
Disconnecting defective condensor/Chiller/Hot water pump motor,transporting to OEM's service centre for checking,dismantaling of parts,removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor motor of capacity 3 HP,Three Phase, 415 V, 50 Hz, with super enamelled copper wires of existing size/gauge including provision of all insulating materials and varnishing,lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations,replacement of defective parts,re-assembling, including testing and commissioning,complete all as specified and directed. Note :- Spares parts for replacement will be measured and paid separately under respective items of this BOQ.
Disconnecting defective condensor/Chiller/Hot water motor,transporting to OEM's service centre for checking,dismantaling of parts,removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding motor motor of capacity 5 HP,Three Phase, 415 V, 50 Hz, with super enamelled copper wires of existing size/gauge including provision of all insulating materials and varnishing,lubrication of bearing / bushes using fresh lubricant all as per OEM's reccommendations, replacement of defective parts,re-assembling, including testing and commissioning,complete all as specified and directed. Note :- Spares parts for replacement will be measured and paid separately under respective items of this BOQ.
Taking down carefully shafts from various type/capacity of pump motor sets of capacity 03 HP, re-metalling worn out portion by welding with suitable electrode as per the material of construction of the shaft, turning and machining to its existing dia./size,including re fixing in original position,complete all as specified and directed.
Taking down carefully shafts from various type/capacity of pump motor sets of capacity 05 HP, re-metalling worn out portion by welding with suitable electrode as per the material of construction of the shaft, turning and machining to its existing dia./size,including re fixing in original position,complete all as specified and directed.
Supply Only,chrome steel ball , for Pump motor capacity upto 3 HP complete all as specified. (Make: TATA/NBC/SKF)
Supply Only,chrome steel ball bearing Pump motor capacity upto 5 HP,complete all as specified. (Make: TATA/NBC/SKF)
Supply Only, impeller suitable for Condensor/Chiller/Hot water generator pumps of capacity of 3.0 HP as per OEM's specifications.
Supply Only, impeller suitable for Condensor/Chiller/Hot water generator pumps of capacity of 5.0 HP as per OEM's specifications.
Supply Only, mechanical seal set suitable for Condensor/Chiller/Hot water generator pumps of capacity up to 5.0 HP as per OEM's specifications.
Supply Only,coupling suitable for Condensor/Chiller/Hot water generator pumps of capacity up to 3.0 HP as per OEM's specifications.
Supply Only,coupling suitable for Condensor/Chiller/Hot water generator pumps of capacity up to 5.0 HP as per OEM's specifications.
Supply Only, gland packing (teflon asbestos with mechanical seal) suitable for Condensor/Chiller/Hot water generator pumps of capacity up to 5.0 HP as per OEM's specifications.
Supply Only, electrical terminals including terminal plates suitable for pump motors,3 Phase, 415V as per OEM's specifications.
Supply Only, PVC cooling fan blade suitable for pump motors,3 Phase, 415V as per OEM's specifications.
Materials and Labour for carring out the leak test by nitrogen gas filling for desired pressure testing for 24 Hours, arresting the leakages, removing the entire Nitrogen gas after testing, evacuating the system by vaccum Pump and charging the fresh refrigerant to full capacity of 2x 26 TR plant for smooth functioning of AC Plant installed in CRRW Building,complete all as specified and directed. Note: Charging of fresh refrigerant will be measured and paid separately under relevant item
Materials and Labour for carring out the leak test by nitrogen gas filling for desired pressure testing for 24 Hours, arresting the leakages, removing the entire Nitrogen gas after testing, evacuating the system by vaccum Pump and charging the fresh refrigerant to full capacity of 3x 26 TR plant for smooth functioning of AC Plant installed in Signal Section Building,complete all as specified and directed. Note: Charging of fresh refrigerant will be measured and paid separately under relevant item
Material and Labour for painting to Air-Conditioning Plant machinaries, Motors, Condensers, Pipe Lines , pumps,air handling unit, etc. of AC plants of capacity upto 26 x2 TR, with with one coat of synthetic enamel paint after preparation of old painted surfaces,all as per the existing and OEM's reccommended colour code,complete all as specified and directed. AC Plant installed in CRRW Bldg
Material and Labour for painting to Air-Conditioning Plant machinaries, Motors, Condensers, Pipe Lines , pumps,air handling unit, etc. of AC plants of capacity 26 x3 TR, with one coat of synthetic enamel paint after preparation of old painted surfaces,all as per the existing OEM's reccommended colour code,complete all as specified and directed. AC Plant installed in Signal Section Building
Supply and Fix in repair,pressure gauge,round,with analog display of pressure range 0-150 psi,suitable for discharge line of AC Plants, all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,pressure gauge,round,with analog display of pressure range 0-300 psi,suitable for liquid line of AC Plants,all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,Water Temprature Thermometer,100 mm dia, temperature range 0-100 Degree Centigrade,suitable for water line of AC Plants,all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,water flow switch,suitable for water line of AC Plants,all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,Oil Pressure Gauge,with analog display of oil perssure range 0-5 bar,suitable for compressor of AC Plant,all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,V Belt,B-68/B-65 suitable for drive pulleys of AC Plant equipments all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair, V Belt,B-112 suitable for drive pulleys of AC Plant equipments all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair, V Belt,B - 72 suitable for drive pulleys of AC Plant equipments all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,Solonoid Valve,size 1/4",suitable for AC Plants of capacity 26 TR to 52 TR,all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,Safety Valve,rating 350 psi,suitable for discharge line of AC Plants,all as per OEM's specifications,complete all as specified and directed.
Supply and Fix in repair,LWT/ HWT Sensor,thermowell insert type,SS 304,encapsulated probe,operating temperature 0-120 Degree Celcius,suitable for 26 TR capacity AC plants,all as per OEM's specifications, complete all as specified and directed.
Supply Only,refrigerant R 22 suitable for various AC plants,all as per OEM's specifications,complete all as specified.
Supply Only,refrigerant R134a suitable for various AC plants,all as per OEM's specifications,complete all as specified.
Supply and Fix in repair,scroll type sealed compressor of capacity 13 TR with all accessories,base mounting accessories,liquid line and discharge line valves,safety valve including refrigerant charging and oil charging all as per OEM's specifications,including testing for satisfactory cooling effect and commissioning,complete all as specified and directed. Note:- Old unserviceable compressor shall be deposited to AGE E/M store yard and receipt voucher obtained.
Supply and Fix,32 mm bore,galvanized steel tubing,medium grade with all fittings in pipe line of AC plants including all required jointing arrangements as per OEM's reccommendations and including taking down existing unserviceable pipeline,complete all as specified and directed.
Supply and Fix in repairs,gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe 25 mm bore, complete all as specified and directed.
Material and Labour replacement of insulations for ducting of AC Plants,size 5ft x 5ft ,all as per OEM's reccommendations and specifications,complete all as specified and directed.
Supply and Fix in repair,micro processor controller with PCB card suitable for water cooled unit of AC Plant of capacity 26 TR,all as per OEM's specifications,complete all as specified as directed. all as per OEM's specifications,complete all as specified and directed.
Supply and fix as in repair pressure transducer for Evaporator /suction /discharge / condensor suitable for AC plant 26 TR/52TR all as per OEM's specifications,complete all as specified and directed.
M&L for indoor type industrial factory made pedestal type cubical panel board of Suitable size made out of MS sheet 2 mm thick and Passivated Gland Plate, dust and vermin proof and surface provided by equal angle 50x50x5mm protection paneling for instrument/electrical items by 2mm thick MS sheet Degree of protection: - IP42/IP54 as per IS 1394 including surface painted with powder coated ionized spray paint (The Panel Boards shall be cured by 9 tank chemical tank treatment process) by spraying including filling cavities of pillar, 2 coats of painting after primary coat (red oxide) , front and back opening with locking arrangement . Provision of danger notice board and the following electrical items including all connection , grouting etc. LT panel with following accessories :- Note:-Contractor should submit the drawing for approval of GE befor Procurement. Note: Please refer Annexure to BOQ for details of accessories for this item, enclosed with tender documents.
M/S LAKSHMI COOLING CENTRE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .