Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical | - | Rejected-Technical Disqualified |
Tender Value
₹35.4 L
EMD Value
₹50,000
Closing Date
22 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Deputy Vice President (HCD)
HLL Lifecare Limited, HCD Projects, HLL Bhavan, 6th Floor, Golden Jubilee Block, Poojapura, Thiruvananthapuram - 695012, Kerala, Ph 0471-2775651
Setting Pediatric care Unit (PCU) and ICU at GMCH Manjeri, Malappuram at Kerala as per Schedule of Work enclosed
2021_HLL_459946_1
HLL/CHO/HCD/PS/ECRPII/GMCHMLP
Open Tender
Civil Works - Buildings
Item Rate
45 days
GMCH Manjeri
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,800
₹50,000
Yes
4 Jun 2022
10 Dec 2021
23 Dec 2021
10 Dec 2021
22 Dec 2021
10 Dec 2021
180 days
Amount
ECRP Projects
ELECTRICAL WORKS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module (200mmX150mm)
Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box of sheet steel, dustprotected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FRLS PVC insulated copper conductor upto theterminal connector/ neutral link, earthing etc as required (But without MCB/ RCCB/ Isolator).(Note : Prewired vertical type MCB TPDB is normally used where 3 phase outlets are required.)8 way Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.100 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm) 42/43)
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
Supply & laying of one No. PVC insulated and PVC sheathed armoured copper power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.4 core 10 sq mm
AHU WORKS -HDU
SITC 4 -WAY PERFORATED AL DIFFUSER<br>SITC of 4 way perforated aluminum diffusers having the Frame fabricated from high quality extruded aluminum profiles with the advantages of corrosion resistance and rigidity. Perforated panel should be fixed to the frame by screws. having options for including different types of internal cores. Core is fixed to the frame with aluminum pins loaded with steel springs. Core can be easily removable and interchangeable to allow for maximum flexibility in installation and maintenance. For supply air diffusers, Perforated sheet is slightly lowered below the center line. This arrangement provides improved horizontal airflow, etc. complete as required.
FIRE DAMPER WITH FUSIBLE LINK<br>SITC of Fire damper with fusible link having certified fire withstand conditions for 2 hours - 4 hours, as per existing guidelines and UL555 testing standards and having suitable frame size made of galvanized steel of 1.6mm thickness. DAMPER BLADE shall be single skin and have 3 accurately roll formed longitudinal grooves for reinforcement and proper closure. etc. complete as required.
Supply, Installation of Acoustic Insulation of ducts using open cell processed nitrile rubber having a density of 140-180 Kg/m3 and thickness of 10 mm with Microban Certified anti-microbial protection etc. complete as required
Supply, Installation of Thermal Insulation of ducting using Closed Cell Elastomeric nitrile rubber having a density of 40-60 Kg/m3 and with Microban Certified anti-microbial protection etc. complete as required - 13mm
Supply ,Installation of Thermal Insulation of ducting using Closed Cell Elastomeric nitrile rubber having a density of 40-60 Kg/m3 and with Microban Certified anti-microbial protection etc. complete as required - 9mm
Supply, installation, testing & commissioning of of Hard PVC drain piping. Drain Piping with necessary clamps, supports, hangers, and fittings such as bend, reducers, tees, reducers, etc. with 13mm insulation.
VFD -CONTROL PANEL FOR AHU<br>Supply Installation Testing and Commissioning of VFD control panel for AHU operation with all necessary cutouts ,alarms, circuit wiring etc. as required. The scope includes all works prevailing to setting up the control panel and making operational with integrated services as required. Panel shall be fabricated with prior approval from Electrical Engineer and all test certificates shall be furnished before commissioning.
5.5 TR CONDENSING UNIT<br>Supply of 5.5 TR nominal capacity scroll condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventer, overload relays, microprocessor control with digital display, vibration isolation pads etc.(R22 Gas)
AHU-5.5TR<br>S.I.T.C. of Cabinet type Double skin ceiling suspended AHU with outer skin of 0.6 mm pre-coated GSS and inner skin of 0.6 mm plain GSS , 40 mm PUF insulation of 40 kg density with thermal break profile .The Air Handling Unit shall consist of Mixing Box with fresh air intakes with dampers, filter section with10 micron Pre filter( MERV 7) & 5 micron fine filter( MERV 14) Coil section ( with 6 Row DX cooling coil), Backward curved plug fan with Aerofoiled design , intertwined coil, access door, marine light, EFF1 quality motor with VFD(VFD as per AHU Manufacturer standard), outlet damper, & vibration isolators. Expansion Valve, Drier with digital display and other specifications as detailed. 5.5 TR , 2200 CFM, 100 mm SP, 6R and 3KW heater (Connected to 2 No.of 5.5 TR Condensing Unit - R22 Gas )
RETURN GRILLE<br>Supplying & fixing of powder coated extruded aluminium Return Air Grills with<br>louvers but without volume control dampers complete as required.
BACKDRAFT DAMPER - AC WORKS<br>Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round BACK DRAFT DAMPER complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications required sheet thickness complete as required.<br>
CANVAS CONNECTOR FOR AC WORKS<br>SITC of thermal insulated, flexible type canvas connector and ribbed rubber pads as vibration isolator in the existing machine to duct mouth using suitable adhesive compound as per technical specification, neatly bolted and adjusted for vibration free mounting etc as required.
DUCTING 1.00mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 1.00 mm thick
ACTUATOR ( FOR MOTORIZED GI VOLUME CONTROL-DUCT MOUNTING)<br>Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted Gl volume control actuator with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room/OH UNIT<br>Motorized (ON-OFF Type) duct mounted Gl volume control Actuator
MOTORIZED GI VOLUME CONTROL DAMPER <br>Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted Gl volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sq mm) for integration within AHU room/OH UNIT etc as required.
DUCTING .8mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
DUCTING .6mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
Description of Work / Item(s)
Amount
ECRP Projects
AHU WORKS -HDU
FIRE DAMPER WITH FUSIBLE LINK<br>SITC of Fire damper with fusible link having certified fire withstand conditions for 2 hours - 4 hours, as per existing guidelines and UL555 testing standards and having suitable frame size made of galvanized steel of 1.6mm thickness. DAMPER BLADE shall be single skin and have 3 accurately roll formed longitudinal grooves for reinforcement and proper closure. etc. complete as required.
RETURN GRILLE<br>Supplying & fixing of powder coated extruded aluminium Return Air Grills with<br>louvers but without volume control dampers complete as required.
DUCTING .8mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
DUCTING .6mm GSS<br>Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required.<br>Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.63 mm thick
HEPA FILTER - NEGATIVE PRESSURE<br>Supply and installation of 1500CFM Flange type HEPA filters (610X610X300MM) efficiency not less than 99.99% for particles of size down to 0.3 micron at exhaust system terminal collars.
4000 CFM cabinet Type Exhaust Fan with 60mm ESP<br>Supply, installation, testing & commissioning of Double skin construction Suspended type with 25 mm thick Sandwiched PUF insulation .Forward/ Backward curved fan with min 70% Efficiency, centrifugal fan belt drive and vibration isolators Guard for inspection door , Pre filter of 10 micron and squirrel cage induction motor EFF1 Grade. Motor with 3.7KW shall be suitable for 415±10% volts, 50 cycles/second, 3 phase AC supply and also suitable for DOL normal Starter switch
2000CFM cabinet Type Fresh Air Fan with 20mm ESP.<br>Supply, installation, testing & commissioning of Single skin construction Suspended type with min 70% Efficiency, centrifugal forward drive fan and vibration isolators, , Guard for inspection door , Pre filter of 10 micron and squirrel cage induction motor EFF1 Grade. Motor with .55KW shall be suitable for 220±10% volts, 50 cycles/second, 1 phase AC supply, or else any higher or equivalent as approved by Engineer in Charge.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
SITC 2 TON SPLIT AC<br>Supply, installation, testing and commissioning of 2 TR, 3 star rated (as per BEE) Air Cooled High Wall mounted Inverter type Split Air Conditioner consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of enegy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. Make: Voltas, Toshiba, Blue Star, Siemens, Mitsubuishi, Hitachi or equivalent
SITC 1.5 TON SPLIT AC<br>Supply, installation, testing and commissioning of 1.5 TR, 3/5 star rated (as per BEE) Air Cooled High Wall mounted Inverter type Split Air Conditioner consisting of high wall mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy efficient suitable rotary compressor for operation on single phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation and fixing of room (fan coil) unit on wall, standard 4 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1" dia drain PVC pipe with insulation 4m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. Make: Voltas, Toshiba, Blue Star, Siemens, Mitsubuishi, Hitachi or equivalent
PAINTING
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .