Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Tender | |
| 2 | L2₹8.5 L+₹55,360 (7.00%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L2 | Rejected-Finance Not Lowest Tender | |
| 3 | L3₹8.8 L+₹92,513 (11.7%)Rejected-Finance GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | L3 | Rejected-Finance Not Lowest Tender |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
18 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Ranikhet
GE Ranikhet
REPAIR / MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT KAUSANI UNDER GE RANIKHET
2021_MES_415321_1
GE/RKT/24 OF 2021-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kausani under GE Ranikhet
Class E cat b (i)
7 documents required · 7 mandatory
₹500
Yes
GE Ranikhet
₹20,000
Yes
8 Mar 2021
22 Jan 2021
20 Feb 2021
22 Jan 2021
18 Feb 2021
6 Feb 2021
60 days
Amount
BOQ ( Sch A ) Electric works Excavation in trenches not exceeding 1.50M wide and not exceeding 1.5M depth in hard/dense soil and getting out for laying pipes, cables etc and fitting including forming bottom surface to required level and slope complete all as specified and directed.
Returning, filling in, trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above starting point complete all as specified and directed..
Dismantling of existing LT pole any size/type from foundation including necessary earth work, dismantling of concrete etc and removed by the contractor complete all as specified and directed.
Material and labour for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, necessary excavation & earthwork in hard / dense soil, PCC sub base block as mass concrete of size 600 X 600 X 150 mm in cement concrete 1:4:8 Type D-2 in base of foundation, PCC foundation block of size 600 X 600 X 1500 mm in cement concrete 1:3:6 Type C-2, pole plinth of size 600 X 600 X 300 mm in cement concrete 1:2:4 Type B-1 including necessary form work as required at site and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed.
Dismantling and taking down unserviceable cross arm channels and angle from section of various sizes and shapes flat iron clamps, including nut bolts and washer and removing from site complete all as specified and directed.
Supply & fixing of cross arms bracing supports clamps, flat iron strips and back plates fabrication from structural steel section incl nuts, bolts washer MS pipe of required size and thickness for extension of height of pole by welding incl bending or welding cold or hot drilling holes for bolt in any shape or size as indicated or directed and inclusive of one primer coat under two finishing coat of aluminum paint complete all as specified and directed.
Supply and fixing in replacement Pin/shackle type insulator, porcelain, vitreous, white, brown or green of size 75mm height and 90mm dia for working pressure 1100 volts LT complete with insulator 12mm dia bolts, washers and nuts, MS strips of size 31 x 3 mm complete all as specified and directed.
Dismantling/taking down all Aluminum/ACSR conductor any size from existing OH lines incl disconnection and as directed.
Material & labour for stringing stretching and then strengthening of ACSR conductor of size 6/1x2.59 mm (weasel) and of size 6/1x2.11 mm (Squirrel) as over head conductor on existing steel tubular poles LT including binding and jointing the conductor with 14 SWG binding wire complete all as specified and directed.
Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.
Material & labour stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamps 50 x 6 mm size bolt, nuts washers, GI steel stay rod 16 mm dia and 1800 mm long stay bow 400 x14mm, GI steel plate 230x230x6mm, two nos thimble loop insulator of size 65x90mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work as shown in electrical plate No. 1 of SSR part - I 2009 on page No 495 including the following :- (i) Excavation in post holes in any type of soil, returning filling & well ramming including disposal soil to distance not exc. 50 mtrs from starting point. (ii) PCC 1:3:6, type C-2 using 40mm graded crushed stone aggregated as in foundation.
Material & labour for galvanised steel wire 4mm dia on LT electric lines including binding, jointing etc complete all as specified as directed.
Tightening / re-stringing of existing loose / broken ACSR conductor / copper conductor or any other type of conductor of any sizes and strengthening as required at site complete all as specified and directed.
Tightening/restringing existing loose/broken continuous GI earth wire 4mm dia on existing LT over head lines including stringing as required at site and all as specified and directed.
Dismantling/taking out LT UG cables/Service cables any size/type removing connection from existing OH lines/trenches/floor/pipe/road etc. all as specified and directed.
Supply, laying , jointing & testing of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 120 Sqmm 3.5 core laid in duct/trenches/along pole etc,making connection complete all as specified. Note : 1. The cost of Al thimbles/lugs etc is included in quoted rate and no extra payment will be made for the same. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items
All as per item No 17 hereinbefore but of size 95Sqmm 3.5 core
All as per item No 17 hereinbefore but of size 50 Sqmm 3.5 core
All as per item No 17 hereinbefore but of size 16 Sqmm 2 core
All as per item No 17 hereinbefore but of size 10 Sqmm 2 core
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note :-Punned down thickness of sand shall be considered for measurement)
Material & labour for brick protection with sub-class 'B' bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed.
Material & labour for PCC 1:2:4, type B-1 (using 20mm graded crushed stone aggregate) as in coping/coller, ducts etc including necessary form work complete all as specified.
Cutting/ trimming of tree branches of any width/ girth up to 2.0 mtr distance on both sides of HT/ LT over load lines and 7.2 m in vertical distance including collection and depositing the retrieved timber at a place as directed by Engr-in-charge. Note :- (i) Each span have a distance 40mtr approximately (ii) All cutting branches of trees shall be thrown away/ burnt at approximate 200 to 500 mtr away as directed.
Supply and fix cable end jointing kit for LT XLPE grade cable for heat shrinkable complete with jointing materials and accessories suaitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35sqmm complete all as specified and directed.
All as per item No 26 here in before but of size 50Sqmm to 95 Sqmm 3.5 core
Material and labour for preparation of old painted steel & iron surface and applying two coats of synthetic enamel paint opain on steel tubular pole of any type upto 1.5m above ground level (in white and black strips of 30cm each) and two coats of aluminum paint above 1.5 mtr height including cross arms, bracing ,clamps GI pipe fittings etc including writing pole Nos with black paint complete all as specified and directed.
Supply & Fixing LED street light fitting 45W 6000K pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded copper conductor cable of three core complete including taking down existing old light fitting any type complete all as specified and directed.
Supply & Fixing LED street light fitting 30 W 6000K pressure die cast aluminium IP66 roadway luminaire with high power LED as light source and electronic driver including GI bracket light grade 25/32mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded copper conductor cable of three core complete including taking down existing old light fitting any type complete all as specified and directed.
Supply & Fixing pressure die cast aluminium LED flood light of capacity 60 Watt complete , including connection to existing system by providing of 4 Sq mm PVC insulated sheathed copper conductor cable of required length and other accessories including taking down old one complete all as specified and directed.
Taking down and supply and fixing of separator/spacer made of good quality hard plastic to with stand on 1100 volt over LT OH line using required number of plastic nuts and bolts etc suitable for 2 conductor complete all as specified and directed. Make:-Jaipur/Dension/M-seal/Modern
All as per item No 32 hereinbefore but suitable for 3 conductor
All as per item No 32 hereinbefore but suitable for 4 conductor
All as per item No 32 hereinbefore but suitable for 5 conductor
Supply and fixing / laying of galvanized iron pipe of 50mm nominal bore light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc with clamps nuts, bolts and washers complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be included in the item rate.
All as per item No 36 hereinbefore but of 40 mm bore
All as per item No 36 hereinbefore but of 32 mm bore
Taking out old unserviceable service connection cable for replacement including Supply & Fixing service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed.
Supply and fixing in replacement of MCCB 315 Amp Four pole 415 volts Breaking Capacity 50 KA with Adjustable thermal & adjustable magnetic setting as per sample .complete all as specified and directed.
Supply and fixing in replacement of MCCB 200 Amp Four pole 415 volts Breaking Capacity 36 KA with Adjustable thermal & adjustable magnetic setting as per sample. complete all as specified and directed.
Supply and fixing in replacement of MCCB 160 Amp Four pole 415 volts Breaking Capacity 35 KA with Adjustable thermal & fixed magnetic setting as per sample .complete all as specified and directed.
Supply and fixing in replacement of MCCB 100 Amp Four pole 415 volts Breaking Capacity 25 KA with Adjustable thermal & fixed magnetic setting as per sample .complete all as specified and directed.
Supply and fixing in replacement of MCCB 63 Amp Four pole 415 volts Breaking Capacity 25 KA with Adjustable thermal & fixed magnetic setting as per sample complete all as specified and directed.
Supply and fixing Three phase Voltmeter Digital type class 0.5 including CT and PT of suitable capacity complete all as specified and directed.
Supply and fixing Three phase Ammeter Digital type class 0.5 incl CT and PT of suitable capacity of complete all as specified and directed.
Supply and fixing Changeover switch 63 Amp Four pole 415 volts ,Off load side handle operated complete all as specified and directed.
Supply and fixing Changeover switch 200 Amp Four pole 415 volts ,Off load side handle operated complete all as specified and directed. Make HPL Cat Part No. COS4FP200 or equivalent cat part No in make specified in particular specification.
Supply and fixing synthetic insulating mat of size 2m x1mx19mm thick complete all as specified and directed.
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 Sqmm stranded conductor complete all as specified and directed.
Supply, fixing and testing of solar tubular battery 100 AH including connection and coververd in metal box complete all as specified and directed.
Supply, fixing and testing of solar LED Street light 24 Watt with inbuiled CCU including connection with cable of suitable size complete all as specified and directed.
Supply and filling of distilled water for battery complete all as specified and directed.
Supply, fixing and testing of solar module / panel suitable for upto 100 watt as per site requirement including connection all as specified and directed.
Supply and filling in replacement of LED Driver for street lights of capacity 25/32 Watt complete all as specified and directed.
Supply and filling in replacement of LED Driver for street lights of capacity 45-50 Watt complete all as specified and directed.
Material and labour for earthing complete with galvanised steel, earth plate electode 600x600x6mm thick buried directly in gournd ( earth pit not less than 2.25mtrs below ground level ) with the top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised Iron Strip of size 25x4 mm as Earth lead by means of bolts, nuts check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 of MES schedule 2009 Part I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all-round the GI earth plate, watering pipe 20 mm dia GI medium grade, GI sheet 0.63 mm thick funnel, wire, gauge, 50mm thick RCC cover in 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C1 , GI protection pipe 15mm dia 'light grade' upto 7.5 Mtr from electrode etc, complete all as specified and directed including testing on completion. NOTE:- i) Earth lead beyond 7.5 m from electrode to earth terminal point/main switch board & GI pipe light grade 15 mm dia for protection against mechanical damage to lead shall be measured separately. ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Material and labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C1, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
Item 59 Contd (f) electronic sensing transformer - 3 Nos (g) Volt meter square type existing size and shape, Make-AE --1No (h)Push button switches - 6Nos (j) Indicator switches of existing sizes -- 6Nos (k) rotary switches for ampere meter R-Y-B off --1 No (l) 12 pin connector --1 No (m) DPDT switch of existing size --3Nos (n) R C Net work for servo motor 3Kg. --1 No
M/S BHATT ENTERPRISES
M/S NAYAL ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .