Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | L1 | Accepted-AOC Correctly quoted | |
| 2 | Rejected-Technical | - | Rejected-Technical High rate | |
| 3 | Rejected-Technical 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | - | Rejected-Technical High rate | |
| 4 | Rejected-Technical | - | Rejected-Technical High rate | |
| 5 | Rejected-Technical | - | Rejected-Technical High rate |
Tender Value
Refer Docs
Closing Date
15 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DEHRADUN
GE MES DEHRADUN CANTT
PROVN OF THREE PHASE CONNECTION TO WASHER MAN SHOP LAUNDARY PLANT AT 2/9 GR BLDG NO P-145 (OTM ACCN) AT BIRPUR DEHRADUN
2021_MES_429509_1
3015/20-21/99/E3
Limited
Job Works
Works
60 days
GE (MES) DEHRADUN
AS PER NIT CONDITIONS
2 documents required · 2 mandatory
₹0
Exempted
20 Mar 2021
10 Mar 2021
17 Mar 2021
10 Mar 2021
15 Mar 2021
10 Mar 2021
30 days
Amount
1. (a) Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with XLPE insulated multi stranded aluminum conductor served with an inner sheathing of PVC tape armored with galvanised steel wire or tape and overall PVC sheathed 50 Sq mm, 4 core nominal cross section for service connections complete all as specified and directed. Qty-RM/50 (b) All as per Item No 1 but 25 Sq mm, 4 core. Qty-RM/25 (c) All as per Item No 1 but 16 Sq mm, 4 core Qty-RM/70 (d) Excavating in trenches, n exc 1.5m wide and m exc 1.5m in depth, for foundation, etc or for shafts, wells, casspits, main holes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for hard and dense soil. Qty-Cum/18 (e) Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm. for hard/dense soil. Qty-Cum/8.2 (f) Removing excavated material n exc. 50m and depositing where directed at a layers not exc 25 cm. for hard/dense soil. Qty-Cum/9.8 (g) M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed. Qty-Cum/06 (h) M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed. Qty-Per 1000 Nos/77 (j) Supply and laying galvanized steel tubing 50mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed. Qty-RM/20 (k) S&F MCB distribution board, TPN 4 way double door, sheet steel, phosphates ,powder coated with 200 amps bus-bar, neutral link, earth bar and din rail 415V complete all as specified and directed. Qty-Each/01 (l) As per items above Ser No 1 (k) but 06 way Qty-Each/01 (m) S&F MCCB 63 Amps three pole 415 volts thermal magnetic trip release ICU=100% ICS having breaking capacity 16KA including connection terminal strip complete all as specified & directed Make: L&T. Qty-Each/02 (n) S&F MCB TPN 415 Volts 16 KA four pole 63m magnetic trip release and setting as incoming with fixing arrangement complete all as specified and directed. Make L&T Qty-Each/16 (o) MCB DB TPN 415 volt One way Qty-Each/06 (p) S&F MCCB 160 Amps four pole 415 volts thermal magnetic trip release ICU=100% ICS having breaking capacity 35KA including connection terminal strip complete all as specified & directed Make: L&T. Qty-Each/01 (q) M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 16 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistandard of size 10 Sq mm as earth wire upto common earth and connected to earth dolly drawing through and including PVC medium grade conduit 20mm dia complete incl taking out old unserviceable sub main all as specified & directed. Make: Finolex Qty-RM/20 (r) M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly drawing through and including PVC medium grade conduit 20mm dia complete incl taking out old unserviceable sub main all as specified & directed. Make: Finolex Qty-RM/200 (s) Supply, install ,testing and commissioning of factory made LT feeder pillar box outdoor type factory made totally enclosed dust & vermin proof single opening with double leaf shutter duly hinged with locking arrangement made of MS angle iron frame work & CRCA sheet of 3.15 mm thick as per IS 5039 duly painted with powder coated of approved shade over a coat of zinc chrome primer after min seven tank treatment process including numbering & lettering mounted on C channel of appropriate size. Necessary holes shall be kept on the kiosk box for incoming and outgoing cable entry, all holes shall be provide with brass cable gland of appropriate size. The feeder pillar box shall be suitable for 415 volts, 50Hz , 3 phase 4 wire system & shall comprise with suitable capacity aluminum TPN bus bar chamber having 3 phase 4 wire system fixed on porceilin insulator with suitable size PVC copper conductor and duly sleeved with 4 coloured heat shrinkable PVC sleeve, thimble & glands complete all as directed with following accessories. (Note:-The cost of the PCC platform deemed to be included in the quoted rates of above said item complete all as specified & directed). Qty-Each Job/01 (i) Incoming MCCB 4 pole 160 Amp, 35 KA Make: L& T 01 Nos (ii) Copper bus bar 300 Amps with air insulators for TPN – 01 set (iii) Outgoing MCCB 3P 63 Amp, 16KA - 03Nos (iv) R,Y,B indicator lamp LED type -01 Set (iv) Ammeter digital -0 to 300 Amps -01 No (v) Digital voltmeter 0-500 volt – 01 No (vi) Connection with suitable copper cable- 01 Job . (vii) ON load change over, 415V, 4 pole of cap.160 Amps. - 01 No. Make : L&T (t) M&L for earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6.3mm thick buried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised from strip of 32x6 mm earth lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcoal, salt including provision of earth lead protected by 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Qty-Each/01 Note: (i) If the desired earth resistance is not found within permissible limit shall be redone by contractor at no extra cost. (ii) Cost of galvanized strip 32 x 6mm earth lead and 40mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering upto 7.5 mtr is included in the rate quoted for this item. (u) All as per item No-15 as above but earth lead GI wire 4.00 mm. dia by means of bolts, Nuts, Check Nuts and washers of galvanized iron and thimbles and other ends of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15 mm. bore and water pipe 20 mm. bore GI light grade with funnel and wire mesh, complete all as shown in elect plate No. 5 of SSR part I of 1991. 2(a) M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm (i) One light point point /bell buzzer point controlled by one-one way switch. Qty-Per Point/30 (ii) One three pin 5 Amp socket on same board with other switches. Qty-Per Point/06 (iii) One three pin 5 Amp socket on independent board Qty-Per Point/10 (b) All as per item No 2 (d) above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sqmm. Qty-Per Point/06 (c) M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multi stranded copper conductor unsheathed in existing PVC / Steel, concealed and existing MS boxes, mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following Make of PVC Wire: Havells/KEI/Finolex/L&T. Note: The wiring to be done as per IE rule and maintain colour code accordingly (i) One light point point /bell buzzer point controlled by one-one way switch. Qty-Per Point/25 (ii) One three pin 5 Amp socket on same board with other switches. Qty-Per Point/06 (iii) One three pin 5 Amp socket on independent board Qty-Per Point/06 (d) All as per item No c (iv) above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sqmm. Qty-Per Point/04 (e) S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed. Qty-Each/83 (f) S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed. Qty-Each/12 (g) S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed. Qty-Each/28 (h) S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified. Qty-Each/12 (j) S&F Bell switch paino flush button type 5 Amp complete all as specified. Qty-Each/02 (k) S&F ding dong bell AC 230 V single pole complete all as specified and directed. Qty-Each/02 (l) S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts. Qty-Each/08 (m) S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC. Qty-Each/12 (n) S&F lamp holder,pvc/polycarbonate type with back platesuitable for batten fittings including 9w LED bulb complete all as specified & directed. Qty-Each/12 (o) M&L for sub main wiring with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm (nominal area) and one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 10 Sq mm as earth wire upto common earth and connected to earth dolly drawing through and incuding PVC medium grade conduit 20mm dia complete incl taking out old unserviceable submain all as specified & directed. Make: Havells/Finolex/L&T Qty-RM/20 (p) All as per Item No (o) but two 6 sqmm with 6.0 sqmm earth wire Qty-RM/20 (q) S&F sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed Make Legrand/Schneider/ABB. Qty-Each/02 (r) S&F sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed Make Legrand/Schneider/ABB. Qty-Each/01 (s) S&F MCB double pole 240 Volt 10 KA 40 - 63 Amp 'B' series conforming to ISI marked complete all as specified & directed Make Legrand/Schneider/ABB. Qty-Each/04 (t) S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed Make Legrand/Schneider/ABB. Qty-Each/24 (u) S&F MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed. Make Legrand/Schneider/ABB. Qty-Each/01 (v) S&F in replacement wall mounted tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten) CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE) Qty-Each/08 (w) Supply, Fixing and testing LED down lighter recessed mounted 2x2 feet36W ultra modern designed LED luminaire which provide soft light and glair free symmetrical illumination suitable for grid ceiling and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on as per Havells Cat Part no: ENDURASLIMPROPLUS2x2PLR28/36WLED 840MOD or equivelent make of PHILIPs/ CROMPTON all as directed by Engr-in-Charge. Qty-Each/06 (x) S&F LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size Make:WIPRO CAT PART NO - LW07-141-XXX-57XX or equivalent, HAVELLS/ CROMPTON Qty-Each/02 (y) S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1 x 40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable sizeAs per Havells Cat Part NO LHFOAJE1TN1IO60 or equivelent of Bajaj/ Philips. Qty-Each/06 (z) Supply and Fixing Integral LED Street Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 40/45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W including taking out old unserviceable street light. Qty-Each/08 (aa) Supply and fixing of LED tube rod 18/20 Watts single or double sided connections polycarbonate complete incl making connection alteration in existing tube light fitting complete. Qty-Each/10
VISHAL ELECTRIC STORE
KIRPAL AGENCY
R N ENTERPRISES
ASHISH ENTERPRISES
Bedi Refrigeration Works
C V ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_479519.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .