Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-Finance | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹27.8 L+₹26,372.50 (0.96%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹30.5 L+₹3.0 L (10.9%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance HIGHEST | |
| 4 | L4₹39.1 L+₹11.6 L (42.2%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance HIGHEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Jan 2020, 6:00 pmClosed
SHRI TC SHISHODIYA, DCWE(C)
MULTAN LINE ARMY AREA JODHPUR-342010 (RAJ)
Preventive/ Corrective maint of several equipments at MRSS, Elect sub stn 11/33 KV line of E/M services, HT system and connected works at Nagtalao in Army area Jodhpur
2019_MES_306771_1
CWE (A) JODH/NAG -78 OF 2019-20
Open Tender
Civil Works
Item Rate
120 days
Army area Jodhpur
4 documents required · 4 mandatory
₹500
Yes
AGE(I) Nagtalao
₹70,000
Yes
17 Jan 2020
16 Dec 2019
14 Jan 2020
16 Dec 2019
13 Jan 2020
30 Dec 2019
Amount
Excavating in trenches n.exc 1.5 m width and n.exc 1.5m in depth for taking out cable and cable cover and getting out in soft soil
Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 Cm
Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point
M&L for sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables. Note :- For the purpose of payment only punned thickness will be measured
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection
Taking out existing HT under ground cable 11KV/33KV volts grade PVC insulated armoured aluminium conductor of size 185 sqmm to 300 sqmm from trenches/duct/pipes, on walls, poles of following unserviceable cable from site.
Supplying ,laying, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armourred electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade, cross sectional area 185 sqmm 3 core suitable for 11KV earthed systems all as specified and directed.
Supplying ,laying, jointing, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armourred electric power cable (Heavy duty ) with aluminium conductor 33000 volts grade, cross sectional area 300 sqmm 3 core suitable for 33 KV earthed systems all as specified and directed.
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm .
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm .
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm .
M&L for Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 sqmm .
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm.
M&L for finding the fault in 180sqmm 3 core 11Kv cable including excavation and return filling complete as specified and directed by Eng-in-charge.
Taking out old damaged cable protection pipe and supply and fix light grade GI pipe of bore 150 mm as specified and directed by eng-in-charge.
Taking out old unserviceable 11 KV pin insulator including taking out 11 KV OH ACSR conductor and Supply and fix 11 KV pin type , porcelain, vitreous, white, brown, green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut , 150mm height, 150mm dia for 11000 Volts grade suitable for fixing of insulator on HT pole including refixing the OH ACSR conductor at the same place incl binding the conductor to insulator with new binding wire complete all as directed Make : BHEL, jayshree, ABB, Pactil , Areva
M&L cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nut/bolts washers welding bending cold or hot drilling holes for bolts of any shape and size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including taking out old unserviceable complete all as directed.
Dismantling of existing defective HT 11 KV Gang operated air break switch and Supply and installation, commissioning and testing of HT 11 KV outdoor type triple pole gang operated air-break switch suitable for horizontal mounting rotating type with 9 insulator 200 amps current rating complete mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore medium grade GI pipe of suitable length with locking arrangement, flat iron clamp 50x6mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers complete all as directed Make:- Jaipuriya or its equivalent
Supply & laid copper strip in repair of size 32 mm X 6 mm as a ring conductor network buried in ground 1 mtr below from surface complete all as directed at site by Engr-in -charge
Taking out old Unsv lightning protection system including Air termination rod, Aluminium strip , GI strip and earthing of any type complete all as specified and directed by Engineer-in-charge.
Supply installation testing and commissioning of lightening protection system Early Streamer Emission (ESE) lightening protection Air terminal OPR 60(Optimized Pulse Rod) complies with NF C-17-102 standards complete all as specified and directed by Engr-in-Charge. Make – ABB Model OPR-60 and equivalent in Alstom/OBLUM
Supply and fix stainless steel pipe of 50 mm dia mounting mast 2 m , 30 mm dia fabricated with support structure and guying kit provided with suitable mounting base plate having provision for fixing of optimised pulse rod and arrangement for down conductor of lightening protection system all as specified and directed by Engr-in-Charge.Make:- Cat Part No MAST 2M30 of ABB or its equvalent in Alstom/OBLUM
Supply, fixing, testing and commissioning of lightening stroke counter working electro mechanically without any power supply. Eqpt should have capacity of counting lighting stroke of 0.4 KA to 150 KA, all as specified and directed by Engr-in-Charge. Make- LS Counter of ABB or its equivalent in Alstom/Oblum
Supply and laying of single core multi stranded copper cable down conductor of size 70 sqmm incl mounting accessories and clamps with suitable fixing material all as directed at site.
Supply and fix undermentioned spares for gang operating switch/DO fuse 33/11 KV complete all as specified and directed by Engr-in-charge. .Make - Jaipuriya or its equivalent :- (a) Male Contact/moving contact Blade heavy duty high conductive metal cap 200/400 amp for GO switch11 KV
(b) Male Contact/moving contact Blade heavy duty high conductive metal cap 200/400 amp for GO switch 33 KV
(c) Female Contact/Fix contact Jaw heavy duty high conductive metal cap 200/400 amp for GO switch 11 KV
(d) Female Contact/Fix contact Jaw heavy duty high conductive metal cap 200/400 amp for GO switch 33 KV
(e) Fixtop contact/L contact or Bottom contact for DO fuse 11 KV
(f) Fixtop contact/L contact or Bottom contact for DO fuse 33 KV
(g) Post insulator for 11 KV
(h) Post insulator for 33 KV
Taking out old unserviceable silica gel breather and Supply & fix new Silica Gel breather having threaded bore as per site required.
Taking out old unserviceable silica gel and Supply & filling new silica Gel dehydrating breathers in crystals
Taking out old unserviceable PG Clamp and supply and fix new PG clamp in repair all as directed and specified.
Supply and topping of transformer oil with adequate dielectric strength as mentioned in relevent IS as and when required to top up as replacement /evaporation ,leakage all as specified and directed by Engineer-in-Charge. Make : Shell , Power oil , servo
Dehydration of Transformer oil (mounted on plateform/ poles etc) with the help of filtering and drying plant by mechanical machine of suitable capacity to achive dielectric strength of 50 KV complete all as specified and directed by Engineer-in-charge. Note : a) The filteration of the transformer oil is to be carried out at different sub station in AGE (E/M) Nagtalao and also at Main receiving sub Station. b) The report along with sample of oil before filteration & after filteration to be submited by contractor for approval by AGE(E/M) c) The filteration is to be carried out on load i.e. without switching off supply. d) Transformer oil for topping up will be paid separately under relevant item of Sch 'A'.
Disconnecting of existing HT 33 KV 3 phase indoor type SF6 complete with indoor controlling box from electric supply and overhauling the same as per manufacturer instruction with complete servicing including gas filling, relay caliberation, oiling and greasing the mechanical moving parts such as moving contacts, plunger & tripping and closing lever and checking the complete tripping/closing system as per manufacturer instruction all as directed by Engr-in-charge.
Disconnecting of existing HT 11 KV 3 phase indoor type VCB complete with indoor controlling box from electric supply and overhauling the same as per manufacturer instruction with complete servicing including relay caliberation, oiling and greasing the mechanical moving parts such as moving contact, plunger & tripping and closing lever and checking the complete tripping/closing system if required replacing the actuating and the restraining coils as per manufacturer instruction all as directed by Engr-in-charge. .
Supply and fix Over Current and Earth fault protection relay suiable for 33/11 KV VCB Panel complete all as specified and directed by Engr-in-Charge.Model SLR 140 C of CG or its equivalent.
Supply and fix Master Trip relay suiable for 33/11 KV VCB Panel complete all as specified and directed by Engr-in-Charge.Make:-CG/Schneider/Seimens
Supply and fix announciator as per existing make and capacity complete all as specified and directed by Engr-in-Charge.CG/Schneider/Seimens
Supply and fix in repair Buch, WTI , OTI Trip relay suitable for 33/11 KV VCB Panel complete all as specified and directed by Engr-in-Charge.Make:- CG/Schneider/Seimens
Supply and fix in repair Digital Volt meter suitable for HT VCB Panel complete all as specified and directed by Engr-in-Charge.Make:-Alpha + V of ELMEASURE or its equivalent
Supply and fix in repair Digital Ammeter suitable for HT VCB Panel complete all as specified and directed by Engr-in-Charge.Make:-Alpha + V of ELMEASURE or its equivalent
Supply and fix in repair Auxialiary relay for Buch, WTI,OTI Alarm suitable for HT VCB Panel all as specified and directed by Engr-in--Charge. Model: CGXH1 3 element Aux relay or its equivalent
Dismantling and taking down defective/damaged HT 11 KV PT and S & F, testing & calibration of 11 KV single phase indoor, Epoxy cast PT of ratio 11KV/√3/110/√3 class 1.0, burden 100 VA/Phase insulation level 28/75 KV, voltage factor 1.2 Cont and 1.5 for 30 Sec, confirming to IS-3156 incl suporting insulator all as directed.
Dismantling and taking down defective/damaged HT 33 KV PT and S & F, testing & calibration of 33 KV single phase indoor, resin cast PT of ratio 33KV/√3/110/√3 class 1.0, burden 100 VA/Phase insulation level 36/70/170 KV, voltage factor 1.2 Cont and 1.9 for 30 Sec, confirming to IS-2705 all as directed.
Supply and fix in repair Current Transformer conforming to IS: 3156-1992 , rated voltage 11 KV, rated frequency-50 HZ, HSV-12, IL-35/75 KV, VF - 1.2 CONT/1.5 for 30 sec , three phase complete all as specified and directed by Engr-in-Charge.Make:-ABB or its equivalent
Supply and fix in repair L 1, L 2, and L 3 Digital phase indicator ,input current-1A or 5 A , Acc Class : CL 1.0, Model Conserv EM 6436 of schneider or its equivalent
Taking out old unserviceable 33 KV pin insulator incl taking out 33 KV OH ACSR conductor and supply and fix 33 KV pin type, porcelain, vitreous, insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut for fixing of insulator on HT pole incl refixing the OH ACSR conductor at the same place incl binding the conductor to insulator with new binding wire complete all as directed. Make: Jaipuria brothers, BHEL, ABB or equivalent.
Taking out old unsv stay assembly and Supply and fix stay assembly complete comprising of MS galvanized stay plate 30cm x30cmx6mm , MS galvanized stay rod 20 mm dia with nut 180 cm long , MS galvanized stay bow 40cm long with 2 Nos galvanized thimbles with and including all fittings incl Excavation, PCC for foundation (PCC 1:3:6) , loop type insulator, shackle & clamp incl GI stay strand wire of size 7/4mm complete all as specified in SSR 2009 Part I.
M&L for repair of microcontroller, transistors,filters,and transformer of 24 V , 1600 Watt battery charger unit in the MRSS to provide DC Power supply to the relay of HT Panel complete all as specified and directed by Engr-in-Charge.Make:-Luminous/Sukom/microtek
Supply and fix in repair Power pack unit of 110 V DC out put to existing HT VCB Panel of 33/11 KV complete all as specified and directed by Engr-in-Charge.
Supply, installation,testing and commissioning single phase input supply, single phase output,PWM technology IGBTbased, ONLINE battery charger for standard maintainance free (SMF) battery bank with feauteres of protection in case of High and Low voltage etc of capacity not less than 5 KVA all as specified and directed. Make:- Exide/Elka/Vintech/ Volina or its equivalent
Material and labour for painting of transformer 11 KV/440 V of 63 - 400 KVA, from outside with two coat of synthetic enamel gray paint after washing / removal of all dust, grease, oil etc after scraping old painted surfaces,writing MES No,stopping of minor leakage through soldering and brazing including PCC, plaster and putty work reqd for basement of transformer & painting with wall primer complete all as directed by Engineer-in- Charge.
M&L for spray painting minimum two coats on old surface with synthetic enamel aluminium paint (ICI asian, Burger or equivalent make) with preparation of surfaces duly rubbing the surfaces with sand paper etc complete in all respect on steel works Note:- Rates are inclusive of paint, paint brush, sand paper, spray gun and any scaffolding material , if required On pole tower of 33 KV
Trimming and prunning upto safe distance from the over head lines including cutting branches of tree of size not exceeding 3" dia complete all as directed at site and disposel of branches/bushes to distance and cleaning the site all as directed by E-I-C Note :-(i)The necessary man power tool and plant , cutting tools and JCB if required for cutting/ prunning of branches is deemed to incl in the rate quoted for the job (ii) Proper shut down will be taken from JE E/M only :- (a)Up to 2" dia of branches
(b) From 2" to 3" dia of branches
Supply anf fix Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 volts all as specified and directed by eng-in-charge.
Supply anf fix Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 33000 volts all as specified and directed by eng-in-charge.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6.3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 metre deep below ground level) with the top edge of earth plate at a depth not less than 1.5 metre below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm in alternate layers on all sides and including GI earth strip of 32x 6 mm as earth electrode bolted with GI nuts, bolts & check nuts and as per electrical plate No. 3 rivetted to earth (Plate) electrode at one end and connected to Panel at the other, earth strip protected by and incl GI pipe 40 mm dia (medium grade) from top of electrode to Panel and also incl watering pipe GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B0 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation & earth work, etc as shown on electrical plate No of SSR Part I.
Shri Electrical Enterprises
Anil Builders
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .