Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹2.5 CrQualified Make: ceasefire
Model: CEASEFIRE CF-000982 (SF) 602 DOLI CHAMBERS 06TH FLOOR BRAHMAKUMARIS MARG NEAR STRAND CINEMA COLABA MUMBAI CITY 2829 400058 INDIA | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | Make: ceasefire
Model: CEASEFIRE CF-000982 (SF) | ₹2.5 Cr Quoted ₹3.6 Cr | L2 | Qualified MSE, Category: General |
| 2 | Qualified Make: ASKA
Model: ASKA HiPRESS 02/050 C 19 20 21 DEV BHOOMI INDUSTRIAL ESTATE PUHANA IQBALPUR ROAD BANTAKHEDI ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | Make: ASKA
Model: ASKA HiPRESS 02/050 | - | - | Qualified MSE |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Oct 2018, 11:00 amClosed
Average Turn Over of Last 3 Years 1200 Lakh (s) Experience with Gov. Required 10 Year (s) Watermist And Caf Fire Extinguisher High Pressure Trolley Mounted ( 80 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Genric Conformity to DIN EN 1866-1:2007-08 standards The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 31 clauses (3.10
6.1
6.2.1
6.2.2
6.2.3
6.3.1
6.3.2
6.3
6.4.1-6.4.3
6.4.4
6.5
6.6
6.7
6.8.1
6.8.2
6.8.3
6.8.4
6.8.6.1
6.8.6.2
6.8.6.3
6.8.6.4
6.8.6.5
6.8.6.6
6.9.1
6.9.2
6.10
7.2.1
7.2.2
7.3
8.1
8.2 ) of DIN EN 1866-1:2007-08 Yes * 1/7 Standard mandatorily applicable for the complete system. For trolley mounted configurations as clause no. 8.1.3 specified fire ratings shall be tested on portable fire extinguisher of same design from such laboratory as per EN 3 - 7:2004 + Al: 2007-08 (E). Trolley Mounted Type Yes * The Trolley mounted configuration shall have water tank
compressed air cylinder and gun mounted on a free moving trolley provided with strong wheels as specified in DIN EN 1866-1:2007-08 Standards. Trolley mounted shall be supplied with two air cylinders. Yes * Main Components: Pressure vessel to hold the media with safety valve
compressed air cylinder coupled with a reducer
hose pipes for discharge of water mist media
extinguishing gun. Yes * System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause No. 6.1 of DIN EN 1866-1:2007-08 standards as per the accredited test report for Trolley mounted system Yes * 2/7 Constructional Model Number as per Accredited Laboratory Test Report is to be declared - * Air Cylinder Capacity 6 6.0 Air Cylinder Material Steel Steel High Pressure Type (Dynamic Operating pressure above 30 bar to be tested in the accredited laboratory test report which will be considered as high pressure as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) 30 * Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55
IV B
Spreading coefficient for special AFFF Compound shall be +5 minimum
concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55
concentration shall be 6%. If special foam mention the composition for special
otherwise put NA Water 96%
1
2-Ethandiol
Fluorinated surfactant < 0.5%
Octylsulfate< 1%
Decylsulfate<1%
Akylpolyglycoside<1% * Commercial Brand Name of the Standard foam (fire extinguishing medium) as per accredited laboratory test report where in IV B fire rating achieved
to be declared. STHAMEX * Characteristics of extinguishing medium of Special AFFF Compound with infrared spectro gram to be furnished
otherwise put NA Density 1.12
Viscosity 2.0
pH factor 8.5
Refractive index 1.3692 at 20 ± 2deg C * Fire Rating for Trolley Mounted IV B and Di Electric. With marking of Fire Class A & B as Yes * 3/7 per EN 3-7 Standard Pressure Vessel Material Aluminum alloy * Thickness of Material (mm) 8 * Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body) to measure the air Cylinder pressure Yes * Pressure Vessel should have CE Marking from Notified body Yes * Extinguishing gun material Stainless Steel * if others Mentions the material for Extinguishing gun
otherwise put NA na * Extinguishing gun weight (750 gram approx) 750 * Length of EN marked Hose (meter) 5 * Performance Air Cylinder pressure (Bar) 300 * Capacity ( Nominal Charge ) 50 * Lancing Distance of Gun 15 * The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes * Operating time in full throttle (seconds) 117 Any applicable numeric value Weight of fully charged Trolley Mounted system having Corrosion Free Aluminum Alloy vessel (kg) 105 * Fire Rating 55 A
1000V with Special AFFF Compound as per 55 A
1000V with Special AFFF Compound as per 4/7 manufacturer own specn manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes * No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur shall also be mandatory Yes * Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes * Availability of Test Report to DIN EN 1866-1:2007-08 standards Yes * Test Report No - * Test Report Date - * Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - * NOC Letter No Date of PESO Nagpur for Pressure Vessel - Any applicable text(s) Test Reports to be furnished to buyer on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Madhusudan Reddy 788001
OC OMC NO 2 MGAR DISTT CACHAR SILCHAR 20 90 2 Ajay Rawat 785005
OC OMC
No-3 MGAR Near Civil Airport Jorhat-785005 20 90 5/7 3 Deepak V Sharma 797112
OMC No-1 MGAR Walford Area Rajbari Complex Near Circuit House Dimapur Nagaland-797112 20 90 4 Vishal Chopra 795015
OC OMC NO 4 MGAR
MARAM 20 90
672001
GEM/2018/B/95299
watermist and caf fire extinguisher high pressure trolley mounted
90 days
Assam; Cachar, Assam; Dimapur, Nagaland; Senapati
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Average Turn Over of Last 3 Years 1200 Lakh (s) Experience with Gov. Required 10 Year (s) Watermist And Caf Fire Extinguisher High Pressure Trolley Mounted ( 80 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values Genric Conformity to DIN EN 1866-1:2007-08 standards The complete system shall be tested for compliance from an int ernationally/nationally accredited laboratory for compliance to all 31 clauses (3.10 | - | - | - |
| 6.1 | - | - | - |
| 6.2.1 | - | - | - |
| 6.2.2 | - | - | - |
| 6.2.3 | - | - | - |
| 6.3.1 | - | - | - |
| 6.3.2 | - | - | - |
| 6.3 | - | - | - |
| 6.4.1-6.4.3 | - | - | - |
| 6.4.4 | - | - | - |
| 6.5 | - | - | - |
| 6.6 | - | - | - |
| 6.7 | - | - | - |
| 6.8.1 | - | - | - |
| 6.8.2 | - | - | - |
| 6.8.3 | - | - | - |
| 6.8.4 | - | - | - |
| 6.8.6.1 | - | - | - |
| 6.8.6.2 | - | - | - |
| 6.8.6.3 | - | - | - |
| 6.8.6.4 | - | - | - |
| 6.8.6.5 | - | - | - |
| 6.8.6.6 | - | - | - |
| 6.9.1 | - | - | - |
| 6.9.2 | - | - | - |
| 6.10 | - | - | - |
| 7.2.1 | - | - | - |
| 7.2.2 | - | - | - |
| 7.3 | - | - | - |
| 8.1 | - | - | - |
| 8.2 ) of DIN EN 1866-1:2007-08 Yes * 1/7 Standard mandatorily applicable for the complete system. For trolley mounted configurations as clause no. 8.1.3 specified fire ratings shall be tested on portable fire extinguisher of same design from such laboratory as per EN 3 - 7:2004 + Al: 2007-08 (E). Trolley Mounted Type Yes * The Trolley mounted configuration shall have water tank | - | - | - |
| compressed air cylinder and gun mounted on a free moving trolley provided with strong wheels as specified in DIN EN 1866-1:2007-08 Standards. Trolley mounted shall be supplied with two air cylinders. Yes * Main Components: Pressure vessel to hold the media with safety valve | - | - | - |
| compressed air cylinder coupled with a reducer | - | - | - |
| hose pipes for discharge of water mist media | - | - | - |
| extinguishing gun. Yes * System shall be designed for maximum operating temperature TS max and minimum operating temperature TS min of 60 deg C or more and 5 Deg C or less respectively and certified by the manufacturer accordingly as per Clause No. 6.1 of DIN EN 1866-1:2007-08 standards as per the accredited test report for Trolley mounted system Yes * 2/7 Constructional Model Number as per Accredited Laboratory Test Report is to be declared - * Air Cylinder Capacity 6 6.0 Air Cylinder Material Steel Steel High Pressure Type (Dynamic Operating pressure above 30 bar to be tested in the accredited laboratory test report which will be considered as high pressure as per clause No. 3.15 of EN 3 - 7:2004 + Al: 2007-08 (E) Standard.) 30 * Type of Foam Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55 | - | - | - |
| IV B | - | - | - |
| Spreading coefficient for special AFFF Compound shall be +5 minimum | - | - | - |
| concentration shall be 6%. Special AFFF Compound conforming to manufacturer own specifications for higher fire rating A55 | - | - | - |
| concentration shall be 6%. If special foam mention the composition for special | - | - | - |
| otherwise put NA Water 96% | - | - | - |
| 1 | - | - | - |
| 2-Ethandiol | - | - | - |
| Fluorinated surfactant < 0.5% | - | - | - |
| Octylsulfate< 1% | - | - | - |
| Decylsulfate<1% | - | - | - |
| Akylpolyglycoside<1% * Commercial Brand Name of the Standard foam (fire extinguishing medium) as per accredited laboratory test report where in IV B fire rating achieved | - | - | - |
| to be declared. STHAMEX * Characteristics of extinguishing medium of Special AFFF Compound with infrared spectro gram to be furnished | - | - | - |
| otherwise put NA Density 1.12 | - | - | - |
| Viscosity 2.0 | - | - | - |
| pH factor 8.5 | - | - | - |
| Refractive index 1.3692 at 20 ± 2deg C * Fire Rating for Trolley Mounted IV B and Di Electric. With marking of Fire Class A & B as Yes * 3/7 per EN 3-7 Standard Pressure Vessel Material Aluminum alloy * Thickness of Material (mm) 8 * Pressure Vessel shall include a pressure gauge fitted on the vessel (CE Marked from notified body) to measure the air Cylinder pressure Yes * Pressure Vessel should have CE Marking from Notified body Yes * Extinguishing gun material Stainless Steel * if others Mentions the material for Extinguishing gun | - | - | - |
| otherwise put NA na * Extinguishing gun weight (750 gram approx) 750 * Length of EN marked Hose (meter) 5 * Performance Air Cylinder pressure (Bar) 300 * Capacity ( Nominal Charge ) 50 * Lancing Distance of Gun 15 * The air hoses shall be suitable for minus 40 deg C to 100 Deg C temperature and EN mark on hose Yes * Operating time in full throttle (seconds) 117 Any applicable numeric value Weight of fully charged Trolley Mounted system having Corrosion Free Aluminum Alloy vessel (kg) 105 * Fire Rating 55 A | - | - | - |
| 1000V with Special AFFF Compound as per 55 A | - | - | - |
| 1000V with Special AFFF Compound as per 4/7 manufacturer own specn manufacturer own specn Certification PED approval as per Directive 97/23/EC Yes * No objection certificate (NOC) for Pressure Vessel from Petroleum and Explosives Safety Organization (PESO) Nagpur shall also be mandatory Yes * Specific consent of the OEM for the value additions made along with a confirmation that fire ratings of the equipment would not be affected by these value additions. Yes * Availability of Test Report to DIN EN 1866-1:2007-08 standards Yes * Test Report No - * Test Report Date - * Name of ILAC/NABL/Central Govt.Accredited Laboratory where Test Conducted - * NOC Letter No Date of PESO Nagpur for Pressure Vessel - Any applicable text(s) Test Reports to be furnished to buyer on demand Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Madhusudan Reddy 788001 | - | - | - |
| OC OMC NO 2 MGAR DISTT CACHAR SILCHAR 20 90 2 Ajay Rawat 785005 | - | - | - |
| OC OMC | - | - | - |
| No-3 MGAR Near Civil Airport Jorhat-785005 20 90 5/7 3 Deepak V Sharma 797112 | - | - | - |
| OMC No-1 MGAR Walford Area Rajbari Complex Near Circuit House Dimapur Nagaland-797112 20 90 4 Vishal Chopra 795015 | - | - | - |
| OC OMC NO 4 MGAR | - | - | - |
| MARAM 20 90 | - | - | - |
Exempted
9 Oct 2018
9 Oct 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_672001.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .