| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.0 LAccepted-AOC 41 CUSTODIAN ANNEXE BEHIND WOOD LAND SCHOOL SHIVPORA SRINAGAR JAMMU KASHMIR 190004 | SRINAGAR | JAMMU AND KASHMIR | 190004 | ₹73.0 L Quoted ₹73.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹75.8 L+₹2.0 L (2.77%)Rejected-Finance | ₹75.8 L+₹2.0 L (2.77%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹83.4 L+₹9.6 L (13.0%)Rejected-Finance | ₹83.4 L+₹9.6 L (13.0%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹94.0 L+₹20.2 L (27.4%)Rejected-Finance OPP KIRYAPA PARK NATIONAL HIGHWAY ROAD BARAMULLA J K 193101 | NA | NA | 193101 | ₹94.0 L+₹20.2 L (27.4%) | L4 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹2.0 L
Closing Date
17 Apr 2021, 6:00 pmClosed
CWE, HQ 133 Works Engrs
HQ 133 Works Engrs PIN-914133 c/o 56 APO
AUGMENTATION AND IMPROVEMENT OF EXISTING E S INFRA AT NAUGAM OR SPL REAPIR TO WIRING AT BLDG NO T 16 T 42 T 47 T 55 T 81 T 85 T 132 AND CERTAIN SANCTIONED WORKS AT RAMPUR AND BARAMULLA UNDER GE 969 EWS AT BARAMULLA
2021_MES_431907_1
CWEK-78/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 969 EWS
Class B Category a i a ii b i and b ii
7 documents required · 7 mandatory
₹1,000
GE 969 EWS
₹2.0 L
Yes
HQ 133 Works Engrs
24 Aug 2021
19 Mar 2021
19 Apr 2021
19 Mar 2021
17 Apr 2021
3 Apr 2021
19 Mar 2021 - 30 Mar 2021
30 Mar 2021
Amount
Supply, installation, testing and commissioning of transformer step down, outdoor type,HT 11 KV,3 phase,LT 433 volts,50 Hz,3 phase 4 wire oil cooled,copper wound in accordance with vector group DYN 11 with neutral brought out on LV side with tapping on HV side to vary secondary voltage upto + or -7.5% instep of 2.5% with externally operated off load type tap changing switch,locking arrengment complete all as IS : 1180 (Part-I) :2014 ( Latest version) with all standard fitting capacity 100 KVA all as specified and directed.
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 11000 volts grade of size 95 Sqmm 3.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 35 Sqmm 3.5 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 25 Sqmm 4.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 4.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 16 Sqmm 2.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 4.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 10 Sqmm 2.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
Supply laying and testing for XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 6 Sqmm 2.0 core ISI marked laid in trenches or passing through pipes/ducts or fixed to walls/poles complete all as specified. Note :- Earth work, brick protection and sand cushioning shall be measured and paid for separately
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 32x6 mm and protection pipe of 40 mm bore medium grade ISI marked,GI medium grade ISI marked 20mm bore watering pipe.
S & F for Switch air break gang operated, 15 insulator type, HT 11 KV, triple pole, vertical type, mechanically operated, for out door use on four pole / two pole structure including installation testing and commission up to 200 Amp current capacity with dropout fuse assembly with fuse carrier, fuse element 5-20 Amp mounted on insulator and steel frame with operating mechanism connection with down rod of 20mm dia medium grade GI pipe worked from ground level complete all as specified and directed.
S & F for ACSR conductor of any size drawn straight horizontal on over head lines on existing poles including binding with insulators, weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag ,jointing jumpers etc, complete all as specified & directed.
Supply and fixing of steel tubular swaged poles erected truly vertical or planted as strut complete with 300x300x6 mm thick mild steel base plate, welded to pole, B-118 final, taper cap,bolts,nuts & screws,poles made out of ERW MS tubing conforming to IS-2713 Part-11 type 410 SP-55 (11.0 metres long) including drilling of holes of reqd size foe fixing of cross arm, painting the exposed surfaces of pole with two coats of aluminium paint over one coat of red oxide zinc chrome primer and with black bitumenous paint externally for portition embedded in concrete, making five black & red bands at lower portition of pole each 300 mm wide alternately,and marking pole NO.with black paint at suitable height complete all specified and directed.
M & L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive two coat of aluminium paint over one coat of red oxide primer, fixed in repair complete all as specified and directed.
M & L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT,25X20cm size, , complete all as specified and directed .
M & L for disc type insulator porcelain vitreous white, brown or green 145mm high and 255mm dia ball and socket type, single disc assembly for tension with tension clamp for conductor of working pressure 11000 volts, fixed in repair complete all as specified and directed.
M & L for lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp, suitable for 11000 Volts, complete all as specified and as directed.
Supply,installation,commissioning and testing of Ring main unit one incoming two outgoing SF6 filled load break switch each of 11 KV,630 complete all as specified and as directed.
M & L for Cable Jointing Kit for 33 KV (Earthed) Grade cable for indoor termination, Heat shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed.
M & L for Cable Jointing Kit for 33 KV (Earthed) Grade cable for Outdoor termination, Heat shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed.
M & L for Cable Jointing Kit for 11 KV (Earthed) Grade cable for indoor termination, Heat shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
M & L for Cable Jointing Kit for 11 KV (Earthed) Grade cable for Outdoor termination, Heat shrink type, joint complete with jointing material and accessories suitable for 3 Core XLPE Armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm complete all as specified and as directed.
Excavation in trenches not exc. 1.5 m wide and not exc. 1.5m deep soft/loose for laying of underground cable, foundation of poles & stays etc., and getting out, complete all as specified and as directed.
All as per Srl Item 27 here-in-before above but depth exc 1.5 m and not exc 3m in hard/dense complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil, complete all as specified
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified.
Sub class ‘B brick,well burnt old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
M & L for 50mm bore `light grade` galvanised tubes ISI marked fixed on walls /laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as specified and directed
M & L for PCC 1:4:8 Type D-2 (using 40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L for PCC 1:3:6 Type C2 using 40mm graded aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
S & F plain, galvanised, 0.63mm thick, class-2, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) complete all as specified and directed.
Street light bracket made out of 40mm bore medium grade pipe of 1.2m length, bent to required shape for fixing on pole and suitable for street light fitting with 02 Nos. clamps of flat iron (25 x 10mm), nuts, bolts and washers including painting with two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed.
M & L for painting to HT poles, 11 mtr , one coat of aluminium paint including preparation of the old paint carefully to make smooth complete and painting strips of red and black from foot of pole upto 5 feet each strip of 30 cm height with one coat of synthetic enamel paint all as specified and directed.
Supply and fixing for junction box of size 250 x 250 x160 mm made of sintex SMC /FRP Nos MCBs 06 Amps including magnetic lock system all as required and fixed to poles with using MS strip of size 32x6mm and nuts and bolts of required size all as specified and directed.
Supply anf fixing multistandered twin core copper conductor (Flexible) FR PVC insulated industrial cables (unsheathed) 2.5 Sqmm 1100 Conforming to IS :694 complete all as specified and directed.
Supply and connecting copper conductor cable multistranded single core with copper lugs of appropriate size on both ends and connecting with pump set starter,fully secured through flexible pipes of suitable size 25 Sqmm complete all as specified and directed.
Making two nos of hole ( one above junction box,and another at bottom of bracket) for passing two runs of 2.5 Sqmm single core PVC cable inside the pole complete all as specified and directed.
M & L for dismantling earth wire or copper conductor, service feeder or distributor span., complete all as specified and directed.
M & L for dismantling cross-arms of M. S. channel or angle sections etc. complete and setting aside for re-use with in 50m, complete all as specified and directed.
M & L for dismantling or ACSR or AAC conductors. Dismantling earth wire or copper conductor, service feeder or distributor span., complete all as specified and directed.
Supply and fixing sluice valve, cast iron ISI marked with flanged ends drilled with iron wheels head shuts and open direction cast on it class PN 1.6 confirming to IS 14846-2000 including necesssary fixing arrengemenmt such as nuts,bolts washer,gasket and packings material etc for 100 mm dia complete all as specified and directed.
Supply and fixing copper thimble of size 25 Sqmm fixed in repair complete all as specified and directed.
Supply installation commissioning and testing of electric driven centrifugal pumping set of capacity 100 HP at 120m head,discharged capacity 20000 Gln/Hr (91.00 Cum/Hr) comprising of cast iron body gun metal impeller, water cooled type, stainless steel shaft complete with 3 phase 415 Volts 50 Hz induction motor of 1450 RPM complete with suitable oil immetsed star delta starter including safety device suitable PCC foundation nuts,bolts channels frame and grouting of starter and electric connection complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 32x6 mm and protection pipe of 40 mm bore medium grade, ISI marked ,GI medium grade, ISI marked 20mm bore watering pipe.
M & L for earthing complete with galvanised steel earth plate electrode 60x60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth strip 25x4mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel including PCC (concrete chamber) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate,with fair finish internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4,funnel with wire gauge of (0.68) 8 mesh per liner inch,80mm thick RCC pit cover 320 mmx320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM,JALLI and charcoal dust and common salt all as shown in electrical plate No.5 of MES SSR Part-1 and specified including provision of earth wire protected by 40 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore medium grade GI pipe,and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/LT panel etc.and testing on completeion complete all as spec ified and directed. NOTE: The quoted rate of earthing shall be deemed to included cost of 7.5m long galvanised earth strip 25x4 mm and protection pipe of 40 mm bore medium grade ,GI medium grade ISI marked 20mm bore watering pipe.
M & L for taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), and making good disturbed surfaces of walls floors, etc., complete all as specified and as directed by the Engineer-in-Charge
M & L for Point wiring in colour code with 1.5 Sqmm (7/0.53) single core multi-stranded copper conductor FRLS (multistrand) PVC insulated and un-sheathed heavy duty cable in and including PVC rigid concealed conduits 2.0mm wall thickness, ISI marked not less than 20mm dia with all fittings/accessories terminated into cast iron/pressed steel terminal boxes, joint boxes, other boxes made from 1.2mm thick MS sheet of suitable size for mounting switches, sockets, fan regulators, light fittings etc., on 3mm thick hylam brand IS-2036 laminated sheet top cover and also including PVC insulated 1.5 Sqmm copper stranded conductor as earth wire (green colour) connected to common earth dolly complete all as specified and directed.
M & L for All as per Srl item No. 53 here-in-before above but one light/fan/bell point controlled by one 5/6 Amps switch one way switch complete all as specified and directed.
M & L for All as per Srl item No. 53 here-in-before above but for 3 pin, 5/6 Amp socket outlet on independent board complete all as specified and directed.
M & L for All as per Srl item No. 53 here-in-before above but for 3 pin, 5/6 Amp socket outlet on same board with other switch complete all as specified and directed.
M & L for Point wiring in colour code with 2.5 Sqmm (7/0.67) single core stranded copper conductor FRLS (multistrand) PVC insulated and un sheathed heavy duty cable in and including PVC rigid concealed conduits 2.0mm wall thickness, ISI marked not less than 20mm dia with all fittings/accessories terminated into cast iron/pressed steel terminal boxes, joint boxes, other boxes made from 1.2mm thick MS sheet of suitable size for mounting switches, sockets, fan regulators, light fittings etc. on 3mm thick hylam brand IS-2036 laminated sheet top cover, and also including PVC insulated 2.5 Sqmm copper stranded conductor as earth wire (green colour) connected to common earth dolly for one Three pin socket outlet 15Amp Independent , complete all as specified and directed.
S & F for Switch piano, flush type, Single pole, One way, 6 Amp complete all as specified and directed.
S & F for Switch piano, flush type, Single pole, One way, 16 Amp fixed in repair complete all as specified and directed.
S & F Socket outlet, 2 in 1, 3 pin, 5/6 Amp flush type, fixed in repair complete all as specified and directed.
S & F for Socket outlet, 2 in 1, 3 pin, 5/6 and 15/16 Amp, flush type , complete all as specified and directed.
S & F for ceiling rose, surface bakelite, 65x50mm, two to three terminals, complete all as specified and as directed by the Engineer-in-Charge.
S & F for Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and as directed by the Engineer-in-Charge.
S & F for Fan step regulator, 120 W, 2 Module fixed in repair completet as specified and directed.
S & F for LED lamp 9W,base B-22 complete all as specified.
S & F decorative ultra slim aluminium LED lighgting fixture 22 W with high lumen output,environmental friendly,energy efficient ready to use pack completet as specified and directed.
S & F MCCB 4 pole,415 volts ,fixed type 63 Amps with breaking capacity 16 KA,OPTIUM 1.0 (fixed with ternal magnetic range) completet as specified and directed.
S & F MCCB 4 pole,415 volts ,fixed type 100 Amps with breaking capacity 16 KA,OPTIUM 1.0 (fixed with ternal magnetic range) completet as specified and directed.
S & F MCCB 4 pole,415 volts ,fixed type 160 Amps with breaking capacity 36 KA,OPTIUM 1.0 (fixed with ternal magnetic range) completet as specified and directed.
S & F Bus bar chamber current rating 200 Amps 8 way completet as specified and directed.
S & F OFF load change over switch AC 21 (side handle) 400 Amps capacity with enclosure rated voltage 415V AC 50Hz type FP completet as specified and directed.
S & F for sheet metal enclosure, factory made for DBs, double door when MCB's to be used, single pole & neutral, 415 volts, 4 way, complete all as specified and directed.
S & F for sheet metal enclosure, factory made for DBs, double door when MCB's to be used, single pole & neutral, 415 volts, 8 way, fixed as in repair complete all as specified and directed.
S & F for sheet metal enclosure, factory made for DBs, double door when MCB's to be used, single pole & neutral, 240 volts, 4 way, fixed as in repair complete all as specified and directed.
S & F for MCB, TPN, 63 Amp, AC, 415 Volt, C Curve complete all as specified.
S & F for MCB, single pole, 6 to 32 Amp, AC, 240 Volt, C Curve complete all as specified.
S & F for MCB, single pole neutral, 40 Amp, AC, 415 Volt, C Curve complete all as specified.
M & L for Sub main wiring with single core copper conductor cable multistrand (FR-PVC) insulated and unsheathed by using 2 single core, copper 6 Sqmm cable with one single continuous 6 Sqmm copper conductor cable PVC insulated and un sheathed (green colour) earth wire connected to common earth dolly in and including concealed PVC rigid conduit of 25mm dia, 2.0 mm wall thickness (ISI marked) with all fittings and fixing accessories, complete all as specified and as directed. Note :- Two runs of 6 sqmm and one one run of 6 sqmm cable as earth along with PVC casing will be measured as one lenght.
S & F for Trivector meter with PT ratio 33000/110V and CT ratio 100/5A,class of accuracy 0.5 with switch board,out door type,duly power coated fitted with "Secure" complete all as specified and as directed. Make : Electricfield, L&T/Legrand/Indoasian or as equivalent
S & F for Trivector meter with PT ratio 11000/110V and CT ratio 100/5A, class of accuracy 0.5 with switch board,out door type,duly power coated fitted with "Secure" complete all as specified and as directed. Make : Electricfield, L&T/Legrand/Indoasian or as equivalent
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the plate not less than 1.50 m below normal ground level, connected to galvanized earth wire 4.0 mm dia by means of bolts, nuts and washers of galvanized iron or steel and including earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 (Using 20mm graded stone aggregates) pre-cast RCC cover in 1:2:4 type B1, 40mm thick reinforced with XPM not weighting not less than 1.87 Kg/Sqm with suitable handle, charcoal common salt, 20mm bore GI ‘medium grade’ ISI marked watering pipe, funnel and 15mm bore ‘light grade’ protection pipe and testing on completion all as shown in electrical plate No 3 of SSR- 2009 Part-I, complete all as specified and directed.
M&L for Construction of shed for Transformer including steps,plinth protection,cable duct complete all as specified and directed as shown on drawing NO CESZ/TD-1110/2011 sheet 1/2 and 2/2 Dated 01/12/2011
Supply installation, testing & commossioning of feeder & piller box outdoor/ indoor type factory made dust & mermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee sanction 100x50x6mm (Frame) double door front/ rear with opening & looking arrangement floor/ wall mounted Bus Bar chamber (enclosed) with suitable size of 300 Amp aluminium Bas bar fixed on post imulated spray painting with two coats of synthetic enemal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on PCC block fixed with granted bolts nuts & washers complete in in all respect & including the following :- (a) MCCB 4 Pole, 415 Volts 200 Amp with 36 KA bracking capacity -01 Nos (b) MCB DP, 40/32 Amp with - 10Nos (c) Neon indicator lamp RYB-01 Set Digital Volt meter 0 to 400 Volts with ss-01 Nos Digital Ammeter 0 to 800 Amps with s/s & CT's-01 Nos
Supply installation, testing & commossioning of feeder & piller box outdoor/ indoor type factory made dust & vermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee section 100x50x6mm (Frame) double door front/ rear with opening & looking arrangment floor/ wall mounted Bus Bar chamber (enclosed) with suitable size 800 Amp aluminium Bas bar fixed on post imulated spray painting with two coats of synthetic ememal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on PCC block fixed with granted bolts nuts & washers complete in all respect & including the following:- (a) MCCB 4 Pole, 415 Volts 500 Amp with 36 KA bracking capacity-01 Nos (b) MCCB 4 Pole, 415 volts 100 Amp with 16 KA brack capacity - 05 Nos (c) Neon indicator lamp RYB - 01 Set (d) Digital volt meter 0 to 400 Volts with ss - CT's - 01 Nos (e) Digital Ammeter 0 to 800 Amps with s/s & CT's - 01 Nos
Supply installation, testing & commossioning of feeder & piller box outdoor/ indoor type factory made dust & vermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee section 100x50x6mm (Frame) double door front/ rear with opening & looking arrangment floor/ wall mounted Bus Bar chamber (enclosed) with suitable size 200 Amp aluminium Bas bar fixed on post imulated spray painting with two coats of synthetic ememal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on PCC block fixed with granted bolts nuts & washers complete in all respect & including the following:- (a) MCCB 4 Pole, 415 Volts 160 Amp with 36 KA bracking capacity-01 Nos (b) MCCB DP 40/32 Amp - 02 Nos (c) Neon indicator lamp RYB - 01 Set (d) Digital volt meter 0 to 400 Volts with ss - 01 Nos (e) Digital Ammeter 0 to 800 Amps with s/s & CT's - 01 Nos (f) MCCB 4 Pole, 415 Volts 63 Amp with 25 KA bracking capacity - 01 Nos
Supply installation, testing & commossioning of feeder & piller box outdoor/ indoor type factory made dust & vermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee section 100x50x6mm (Frame) double door front/ rear with opening & looking arrangment floor/ wall mounted Bus Bar chamber (enclosed) with suitable size 200 Amp aluminium Bas bar fixed on post imulated spray painting with two coats of synthetic ememal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on PCC block fixed with granted bolts nuts & washers complete in all respect & including the following:- (a) MCCB 4 Pole, 415 Volts 160 Amp with 36 KA bracking capacity-01 Nos (b) MCCB 4 Pole, 415 Volts 160 Amp with 36 KA bracking capacity - 01 Nos (c) Neon indicator lamp RYB - 01 Set (d) Digital volt meter 0 to 400 Volts with ss - 01 Nos (e) Digital Ammeter 0 to 800 Amps with s/s & CT's - 01 Nos (f) MCCB 4 Pole, 415 Volts 100 Amp with 16 KA bracking capacity - 01 Nos
Supply installation, testing & commossioning of feeder & piller box outdoor/ indoor type factory made dust & vermine proof fabricated from 3.15 thick CRCA sheet angal iron & tee section 100x50x6mm (Frame) double door front/ rear with opening & looking arrangment floor/ wall mounted Bus Bar chamber (enclosed) with suitable size 200 Amp aluminium Bas bar fixed on post imulated spray painting with two coats of synthetic ememal paint over a coat of red oxide primer & premised with suitable size of PVC insulated sheathed copper conductor cable dully mounted on PCC block fixed with granted bolts nuts & washers complete in all respect & including the following:- (a) MCCB 4 Pole, 415 Volts 63 Amp with 16 KA bracking capacity-01 Nos (b) MCCB 4 Pole, 415 Volts 63 Amp with 16 KA bracking capacity - 01 Nos (c) Neon indicator lamp RYB - 01 Set (d) Digital volt meter 0 to 400 Volts with ss - 01 Nos (e) Digital Ammeter 0 to 800 Amps with s/s & CT's - 01 Nos
Supply installation, testing & commossioning of Outdoor type Copper wound, three phase, oil cooled, powder coated, having following specifications for potential transformer 33 KV/110 Volt and Current transformer. PT : (1.) Primary Voltage : 33000 Volt, (2) Secondary Voltage : 110 Volt (3) Rated Burden : 10 VA, (4) Accuaracy Class : 0.5 (5) Frequency : 50 Hz, (6) Phase : 3, (7) Insulation Class : A (8) IS : 3156 : The potential transformer shall confirm to IS : 3156 CT : (1) Primary Current : 200A, (2) Secondary Current : 5 A, (3) Rated Burden : 5 VA, (4) Accuaracy Class : 0.5, (5) Frequency : 50 Hz (6) Phase : 3 (7) Insulation Class : A (8) IS : 2705 : The potential transformer shall confirm to IS : 2705
Supply installation, testing & commossioning of Outdoor type floor mounting 33 KV CT-PT meter, HT cable with following specifications:- PT : (1.) Primary Voltage : 11000 Volt, (2) Secondary Voltage : 1110 Volt (3) Rated Burden : 10 VA, (4) Accuaracy Class : 0.5 (5) Frequency : 50 Hz, (6) Phase : 3, (7) Insulation Class : A (8) IS : 3156 : The potential transformer shall confirm to IS : 3156 CT : (1) Primary Current : 200A, (2) Secondary Current : 5 A, (3) Rated Burden : 5 VA, (4) Accuaracy Class : 0.5, (5) Frequency : 50 Hz (6) Phase : 3 (7) Insulation Class : A (8) IS : 2705 : The potential transformer shall confirm to IS : 2705
Meterial ad labour for cutting of metallic road/ hard standing/ hard rock/ wall upto a size not exceedig 20 cm width and not exceedign 60 cm depth for laying of protection pipe for cable including making good the disturbed road/ hard standing by providing PCC (1:2:4) type B1 (using 20 mm grade crushed stone aggregated upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface including suitable size of GI pipe (if necessary) complete all as specified and directed. Note : 1. If damaged/ broken the any type of tiles while reomoving, the contractor shall replace the borken tiles with new one. 2. The Quoted rate is included for all materials/T&P/Machinery used in this item, no material can paid/ measured separately. 3. All the removable tiles/ refixable material shall kept carefully at a safe place for refixing with in this quoted rate. 4. GI Pipe shall measured and paid separately under relevant item.
Note : Srl items No 82 drawings are available with this office & GE office.Please visit this office/GE office during working hours before submission of tender for perusal of drawings.
M/S Noor Mohammad Shalla
M/S KULBIR SINGH SODHI AND CO
M/S GHULAM RASOOL LONE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .