Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.3 LAccepted-AOC | ₹13.3 L | L1 | Accepted-AOC Lowest.Accepted by tender Committee |
Tender Value
₹12.0 L
EMD Value
₹18,100
Closing Date
10 Sept 2021, 6:00 pmClosed
The Executive Engineer Electrical HEED Harbor Engi
O/o The chief Engineer, Harbour Engineering Electrical Division, Kamaleswaram,TVPM
Fisheries - Ullanam Fish Seed Farm - Providing additional light masts and electrical up gradation works of Quarantine unit and office buildling
2021_HED_436133_1
24/HEED/2021-22/S
Open Tender
Electrical Works
Item Rate
60 days
Ullanam Malappuram
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,300
Yes
₹18,100
Yes
30 Nov 2021
25 Aug 2021
13 Sept 2021
25 Aug 2021
10 Sept 2021
25 Aug 2021
Amount
Fabricating, supplying, conveying, lifting and erecting tubular post of overall height 11.70 m using 150mm and 125mm of Heavy duty G.I. Pipe sections having ISI mark and of approved quality(TATA , ZENITH , APOLLO) as per the drawing erected on a RCC footing, using 1:2:4 CC with nominal reinforcement and 6 Nos. of PCC well steining having 0.9m dia and 0.30m height with a muffing of 0.6mx0.6mx1m and 8 numbers of 20mm dia 2.50m long MS foundation bolts having 150mm long standard thread on both ends and 3Nos 20mm and 2Nos 20mm nuts at the top and bottom for each bolt . The post is to be provided with a 20mm thick MS flange of OD 300mm with 8 nos of 20mm bolt holes and a base plate of 600mm square 10mm thick with 8 Nos 20mm dia bolt holes embedded in the concrete 1.8m below ground level. The post should have a 1500mm dia ring made out of 50mm heavy GI pipe with cross supports using 40mm heavy GI pipe at the top for mounting the luminaries and its control gears. A 10mm thick MS flange having OD 300mm at 1200mm below the first ring mounted to the post . The top of the pipe should be sealed with 125mm table F Dummy flange.12mm dia wire rope is to be provided for the entire length of the post as mechanical support for the cables to the luminaries. Inverted Y arrangement using 50mm heavy GI pipe, flange and dummy flange cover and 75mm 4kgf/cm2 PVC pipe with bend to be provided in the concrete muffing for taking out cables. 8 x 75mm stainless steel Bolt & Nut shall be used for fixing all the flange covers.The post is to be painted with two coats of UV resistant polyeruthene paint of approved quality and colour over two coats of best quality industrial epoxy primer and epoxy paint.All MS materials used for fabrication shall be dip galvanised.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker of the following poles suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker of the following poles suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker of the following poles suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size upto 35 sq. mm (clamped with 1mm thick saddle) on wall surface as required.Upto 35 sq. mm (clamped with 1mm thick saddle)
Supply of 4 core 16 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 10 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Supply of 4 core 6 sq mm PVC insulated and PVC sheathed armoured aluminum cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
Supply of 50/40mm (OD/ID) Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to under ground power/communication/ OFC / Signal cable conforming to IS 14930 Part - II
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 x 16 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.upto 4 X 10 sq. mm
Supplying and fixing 50 mm steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.
Providing and fixing10 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : Providing and fixing tie bolt, spring coil and plastic cone in wall shuttering complete as per the direction of Engineer-in-charge 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) for pile cap and plinth beam concrete.
Supplying and fixing steel sheet 4 way prewired vertical type double door TP&N MCB distribution board with MCCB as incomer for 415 volts on surface/ recess complete with loose wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with adequate size of FR PVC insulated copper conductor upto the terminal connector/ neutral link, earthing etc as required .
Supply, conveyance and fixing 40 A, 25 kA (Ics=100%Icu), 3pole, MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing DB as required
Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres.
Supply and fixing Cable Junction Boxes IP 67for outdoor applications (with knock outs for cable entry - Black Colour) suitable for cable sizes 2.5 sq.mm ,93 X 93X 62 mm Hensel model No KF 0202 B or equivalent and accessories for Cable Junction Boxes such as Copper Terminal Set 2.5 sq.mm 5 Pole 1 No,Support for Terminal 1No including fixing the accessories using suitable size Stainless steel Bolt and nut, giving necessary connections, making good the damages etc. as required.
Providing and fixing 6 SWG copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply of superior quality copper earth socket for the 6 SWG earth conductor including crimping etc. as required.
Supply of superior quality copper earth socket for the 3.15mm (10 SWG) earth conductor including crimping etc. as required.
Supply and fixing cubicle type dust and vermin proof 300x600x170 mm, (Mi 2400) Hensel make thermoplastic IP 65 junction box with lid including supplying and fixing 2 Nos Hensel make 10 sq.mm 5pole terminal set for phases and neutral in the existing masonry cubicle fixing the departmentally supplied double pole MCB including giving connection using 2.5 sq.mmpvc insulated copper wire ,drilling necessary holes for termination as well as entry and exit of cable,terminating the earthwire in the earthstrip etc complete.All the bolt nut & washer shall be brass.
Supplying IP66 optical tightness,IP67 driver tightness, IK 10 Impact resistance 200W ,24000 Lumens flood light luminaire with body of aluminium extrusion having operating voltage range 100-277 V, luminaire efficacy >= 120lumen/watt, colour temperature 5700 K colour rendering index - 75,electrical class- I,Lumen maintenance L70@60,000 hrs. Preffered make:Keselec-K Flood 200W- NW with 5 year warranty for the light fitting.
Fabricating and supplying special clamping arrangement for fixing an asymmetrical beam integral LED flood light on 50 mm dia GI pipe ring with two clamps each made out of 50 x 6mm MS flat and 8x40mm SS nuts and bolts for one luminaire. The clamps are to be linked with 40x6mm MS flat with suitable holes 8mm ,10mm or 12mm size with suitable size SS Bolt& Nut to fix the luminaire. All the items are to be painted with two coats of epoxy based industrial primer of approved quality and two coats of epoxy paint of approved colour as per drawing.
Supply of SCHREDER SID or equivalent Street light luminaire 20W LED having>=1915 lumens, an IP66 optical & control gear compartment, a die cast aluminium painted housing, Polycarbonate protector with in built lenses, with easily accessible control gear compartment, suitable for horizontal mounting (Ø32- 42mm), System power (including driver loss) of 20W with luminous efficacy > 95 Lumen/W at Ta 25⁰C. Lifetime residual flux @ Tq 35⁰C @ 50,000 hours = 70%, Ta = 50⁰C, in built surge protection of 4/4 kV (in Differential and Common mode), Power Factor > 0.95, Colour Rendering Index > 70 and Cool white light (5700⁰K) with 5 year warranty for the light fitting.
Conveyance, installation, testing and commissioning of departmentally supplied flood light luminaire with lamp on the existing tubular post of height upto 15m from ground level. All bolt and nut shall be Stainless steel.
Supply and drawing 3 core 1.0 sq.mm multi-core PVC insulated & PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections .
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply, fabrication, conveyance and fixing of 40 mm dia Medium class GI pipe with clamps made from 20 x 3 mm MS flat bent to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of epoxy paint over a coat of epoxy primer, making good the damages, colour washing etc as required (for the installation of outdoor light fittings).
Conveyance, installation, testing and commissioning of T 5 outdoor light fitting with FL lamps/LED/ SV/ MH/ CDMT light fittings with all accessories and lamp etc. of all types directly on the existing pipe/ pole including giving connections with the existing wiring etc as required
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete.
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Supplying and fixing medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
Supplying and fixing medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.6 x 4 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supply and fixing 3/5 W LED ,BC, lamp OSRAM or equivalent
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100 mmX75 mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125 mmX75 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.16A 1 way switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
Supplying and fixing following size / modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying 20 W LED Tube with box type fixtures Essential LED tube 1200 mm 20W 865 T8 API Philips or equivalent
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable etc. as required.
Supply of ceiling fans of 1200 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply and fixing cast aluminium stove enamelled elliptical shaped bulk head fittings with porcelain holder and mesh guard suitable for 3-14W LED lamps including connection etc as required.
Engaging labourers for dismantling the electrical wiring and installations and keeping the same safely at a place as per the direction of the departmental officers at site Wireman
Engaging labourers for dismantling the electrical wiring and installations and keeping the same safely at a place as per the direction of the departmental officers at site Beldar
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)4 way (4 + 12), Double door
Supplying and fixing 40A, four pole, (three phase and neutral), 415 volts,Residual current circuit breaker with Overcurrent Protection (RCBO), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 thermoplastic meterbox with provision for fixing KSEB meter, cut out & Neutral link with sufficient holes for fixing KSEB electronic energy meter.Supply and providing 3 Nos of 63A Porcelain HRC fuse units with 40A HRC fuse link and 1No 63A 2way porcelain neutral link in the meter portion. Necessary holes are to be provided in the box for entry and exit of wire The inter connection should be done using 10.0 sq.mm copper wire.
Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 Hensel make thermoplastic box including supply and fixing 63A, 25kA,4pole MCCB with BUC rotory drive kit setted to 50A , including giving connection using 10.0 sq.mm pvc insulated copper wire.
Fabricating, supplying, conveying, lifting and erecting Single arm tubular post of overall height of 7m using 6m 80mm and 1.5m 50mm Heavy G.I. Pipe having ISI mark and of approved quality with suitable mounting pipe for fixing led fitting with socket diameter 32-40 mm as per the drawing, erected on a RCC 1:2:4 foundation in 3 Nos well steining of 0.25m depth and 0.6 m dia. and a muffing of 0.45x0.45m with height 0.6 m above ground level. The post shall be erected on 4 numbers of 20mm dia GI foundation bolts of length 2.00m having 100mm long standard thread with a 12mm thick GI flange suitable for 80mm C class pipe at the bottom of the post and 20mm thick MS flange on the muffing with 4 nos of 20mm bolt holes and 3Nos of 20mm nuts per bolt. The bottom of the post shall be provided with suitable size stiffner pieces.The post is to be painted with two coats of best quality industrial epoxy paint over two coats of industrial epoxy primer . Muffing to be plastered using cement mortar 1:4, 12mm thick colour washing 2 coats using approved colour etc. complete.All GI pipe sections to be used for the fabrication of the post shall be of TATA/ZENITH/APOLLO make with ISI mark.All steel items shall be hot dip galvanised.
Supply and drawing PVC insulated & sheathed 650/1100 V grade 1.5 sqmm 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.
Supply and fixing Cable Junction Boxes IP 66 for outdoor application( with metric knock outs for cable entry - Black Colour)) suitable for cable sizes upto 16/25 sq.mm ,205 X 255 X 112 mm Hensel model No KF 2525 B or equivalent and Terminal Set 2.5 sq.mm / 4 sq.mm including giving necessary connections, making good the damages etc. as required.
Supplying and making end termination nickel plated single compression brass cable gland for 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Supply of 4 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Supply of BIS approved LED Luminaire with system wattage of 35W, made up of pressure die cast Aluminium body and anti UV PC Protector with integrated lenses for increased pole spacing and uniform light distribution, IP66, IK 08, system efficacy of 110 lm/W, CCT 4000K, operating temp range up to 50 degree and designed for efficient thermal management, lumen maintenance L70@ 50000Hrs, Upward Light Output Ratio is 0% at zero degree inclination to avoid light pollution, suitable for side / vertical mounting up to 48mm diameter, Colour Rendering Index > 70, a driver efficiency > 85%, with internal surge protection of 4kV and Power factor > 0.95.Make: Keselec Cat Ref: Nice-R 35W NW LED or equivalent with 5 year warranty for the light fitting.
Supply and installation testing and commisioning of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi9410 thermoplastic box or equivalent including supplying and fixing TP MPCB Suitable for 5H.P DOL, Rail mounting 415V ,16A, 3pole contactor AC 3 Duty with 1 NO+1 NC -1 No,MPR 303 BE 080 L&T make motor protection Relay - 1 Nos,25 A,415V,50Hz Push button unit ON and OFF - 1 set,2A SPMCB - 3 Nos , 32A two way disconnectable type neutral link-1 No, phase indication lamps-1 set,Legend Plate Danger,415V 100x75mm , MOTOR start and run - 1No,20A 415V AC ELMEX Connecter DIN Rail - 6Nos giving connection using 4.0 sq.mm and 2.5 sq mm pvc insulated copper wire for control wiring ,drilling necessary holes for termination as well as entry and exit of cable,terminating the earthwire in the earthstrip etc complete.All the bolt nut & washer shall be brass.
Supply and installation of wall mounting cubicle type dust and vermin proof size 4 , 600x300x214 mm, Mi2410 thermoplastic box with 25A,16 kA,TP MCCB with 32A 2 way porcelain neutral link and rotary handle , one set phase indication lamp,2A C-curve MCB - 3 Nos ,Panel surface mounting 96sq.mm backlit LED Multifunction meter with RS 485 communication port three line display to read V,A,KVA,KVAr,PF and frequency of make Schneider or equivalent suitable for 415V ,50Hz - 1 No,30/5 tape wound class 1 CT -3 Nos and 2A SP MCB-3 Nos. Sufficient holes for fixing phase indication lamp,multifunction meter and rotary handle in the thermoplastic box are to be provided.Necessary interconnection with suitably rated copper conductor with copper socket are to be provided .
Supply of Exhaust fan 305mm sweep single phase, light duty 1400 RPM, Almonard or Equivalent
Installation of exhaust fan upto 450mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Supply of ceiling fans of 1400 mm sweep Category B Ceiling fan excluding resistance type regulator
Supply and fixing 40/25A, 25kA 3 pole MCCB with rotory drive kit including BUC handle in the existing panel
Supply and fixing DOL starter (L&T , CH or equivalent )for 230V, 2hp induction motor with thermal overload relay and contactor of coil voltage230V/415V AC of approved make as per the direction of Deptl officer
Supply of 2 core 2.5 sq mm PVC insulated and PVC sheathed armoured copper control cable
Supplying and making end termination nickel plated single compression brass cable gland for 2 core 2.5sq mm PVC insulated and PVC sheathed armoured copper conductor cable 1.1 KV grade, including providing earth clip and superior quality copper cable socket.
Conveyance, installation, testing and commissioning of departmentally supplied street light/ area light luminaire with lamp to a height upto 8m from ground level.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. (but without charcoal/ coke and salt) as required.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_619811.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .