Loading…
Loading…
Tender Value
Refer Docs
EMD Value
₹67.5 L
Closing Date
30 Oct 2026, 3:30 pm
SE C and P II
SE CandP II PTCUL
Substation Augmentation of Transformers capacity at 132 kV S/s Bhowali 66 kV S/s Thithki Manglore and 66 kV S/s Karanprayag and Kothiyalsain in Kumaon and Garhwal Zone under Package 6
2026_PTCU4_100602_1
PTCUL/CandP-II/SS-10/2026-27
Open Tender
Electrical Works
Item Rate
540 days
Dehradun
Please refer tender documents and NIT
4 documents required · 4 mandatory
₹29,500
Yes
MD PTCUL
₹67.5 L
Yes
office of SE CandP II PTCUL Dehradun
25 Sept 2026
25 Sept 2026
31 Oct 2026
25 Sept 2026
30 Oct 2026
16 Oct 2026
9 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Price Schedule-A (Supply of Material) for (AUGMENTATION OF TRANSFORMERS CAPACITY FROM 55 MVA (2×20 MVA+3×5 MVA) TO 85 MVA (2×20 MVA+3×15 MVA) INCLUDING CONSTRUCTION OF ASSOCIATED 132 KV & 33 KV BAYS AT 132 KV SUBSTATION, BHOWALI (NAINITAL) ) | - | - | - | - |
| 2 | Supply of the following equipments/material as per the approved technicial specifications/drawings/GTP at 132 KV substation Bhowali. | - | - | - | - |
| 3 | 15 MVA, 132/33 KV, 1-Phase Transformer including Bushings, All Accessories, First Filling of Oil, Online Bushing Monitoring System, Fibre Optic Temperature Measurement System with all associated accessories | 4 | Nos. | - | - |
| 4 | Mandatory Spares of 15 MVA Transformer i.e. HV Bushing (1 no.), LV Bushing (1 No.), WTI (1 No.), OTI (1 No.), MOLG (1 No.), PRV (1 No.), Gaskets (1 set), Valves (1 set) & Buchholz Relay (1 No.) | 1 | Lot | - | - |
| 5 | Nitrogen Injection Fire Prevention & extinguishing system for 3×15 MVA, 132/33 KV, 1-Phase Transformer | 3 | Set | - | - |
| 6 | Online Dissolved Gas Analysis System (Multi Gas Type) for 3×15 MVA, 132/33 KV, 1-Phase Transformer | 4 | Nos. | - | - |
| 7 | Oil Storage Tank (15 KL) | 1 | Nos. | - | - |
| 8 | 145 KV SF6 Circuit Breaker | 1 | Nos. | - | - |
| 9 | 145 KV Horizontal Double Break Bus Isolator without Earth Switch | 2 | Nos. | - | - |
| 10 | 145 KV Current Transformer, 5-Core, Ratio (400/200/1A), Accuracy Class-0.2S with CT Clamp with Rod Type Bushing (Without thread bushing) and Junction Box | 3 | Nos. | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.21 MB
TenderDocument.pdf
Tender Documents • 0.94 MB
vendorregistrationform.pdf
Additional Documents • 3.31 MB
PQRsheetPartI.xls
Other Document • 0.15 MB
BOQ_118573.xls
BOQ • 0.39 MB
TS_1. Tf 23.09.2026.pdf
Other Document • 1.87 MB
TS_2. Switchgear 27-04-2026.pdf
Other Document • 0.97 MB
TS_3. Control & Relay Panel 23.08.2023.pdf
Other Document • 0.43 MB
TS_4. Switchyard Erection 13 DEC 23 CORRECTED.pdf
Other Document • 0.79 MB
TS_5. Power and Control Cables 1.1kV 30-05-2018.pdf
Other Document • 0.17 MB
TS_6. Section Structure Rev 6.pdf
Other Document • 0.27 MB
TS_Annexure- Rating Plate 7.5MVA.pdf
Other Document • 0.17 MB
TS_scope_Scope bhowali.PDF
Other Document • 1.80 MB
TS_scope_Scope Karanprayag & Kothiyalsain.pdf
Other Document • 0.13 MB
TS_scope_Scope Thithki.pdf
Other Document • 0.31 MB
AnnexureA.pdf
Additional Documents • 0.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .