Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-Finance | ₹5.3 L | L1 | Accepted-Finance L1 |
| Sl No | Description | Qty | Unit | All Star Group L1 |
|---|---|---|---|---|
| 1.00ELECTRIFICATION | ||||
| 1.00 | OD279388/2025-2026:Supply, Installation, Testing and Commissioning of wall mounting split Inverter type air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R32/410A eco friendly refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following
capacity including refrigerant copper piping 3m with insulation, control cable up to 3-5m, 3 m drain pipe, Copper
Condenser, stand, microprocessor control with cordless remote control etc. PCB should have minimum 5 year warranty and 10 year warranty on compressor(warranty card are to be provided).Minimum 2 Nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 2/2.2TR (3 Star& above) Inverter A.C unit, (Blue star/LG/ Daikin / carrier/Panasonic/Hitachi) | 7 | each | 66,500 ₹4.7 L |
| 1.00 | OD279389/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage
range of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent) - (Rate exclusive of GST) | 7 | each | 3,000 ₹21,000 |
| 1.00 | OD279390/2025-2026:Supply and fix 25mm pvc drain pipe with all accessories in surface/recess
including cutting walls and making good the damages etc as required | 20 | each | 132 ₹2,640 |
| 1.00 | 90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator | 7 | each | 242 ₹1,694 |
| 1.00 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator | 7 | each | 116 ₹812 |
| 1.01 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket | 7 | each | 288 ₹2,016 |
| 1.01 | 90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm | 25 | metre | 100 ₹2,500 |
| 1.01 | 90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm | 45 | metre | 50 ₹2,250 |
| 1.01 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm | 20 | metre | 215 ₹4,300 |
Updated dates
Tender Value
₹5.4 L
EMD Value
₹13,434
Closing Date
22 Jan 2026, 5:00 pmClosed
BDO
Block development office Kothamangalam
Kothamangalam Block Panchayath Project Number SO255/26-Supply Installation Testing and Commissioning of Air Conditioner for Block Panchayath Office-Electrical AC Work
2025_CRD_810783_3
122256 Supply Installation Testing and Commissioning of Air Conditioner for Block Panchayath Office
Open Tender
Electrical Works
Block development Office
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,185
₹13,434
20 Feb 2026
8 Jan 2026
24 Jan 2026
8 Jan 2026
22 Jan 2026
8 Jan 2026
ELECTRIFICATION
OD279388/2025-2026:Supply, Installation, Testing and Commissioning of wall mounting split Inverter type air conditioner unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R32/410A eco friendly refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with insulation, control cable up to 3-5m, 3 m drain pipe, Copper Condenser, stand, microprocessor control with cordless remote control etc. PCB should have minimum 5 year warranty and 10 year warranty on compressor(warranty card are to be provided).Minimum 2 Nos free service per year for the entire guarantee period and it should be ensured that the air conditioner is in perfect working condition during this period. 2/2.2TR (3 Star& above) Inverter A.C unit, (Blue star/LG/ Daikin / carrier/Panasonic/Hitachi)
OD279389/2025-2026:Supply and Fixing of 5 KVA voltage stabilizer for split type A/C unit with voltage range of 175-275V and out put range of 210 - 240V (V-Guard or its equivalent) - (Rate exclusive of GST)
OD279390/2025-2026:Supply and fix 25mm pvc drain pipe with all accessories in surface/recess including cutting walls and making good the damages etc as required
90.10.3.14:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A SP switch with indicator
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.10.3:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required32 mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm
1.17.25:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.7 x 4 sq. mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_1386290.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.04 MB
viewsbdAirconditioningblock.pdf
Tender Documents • 1.63 MB
BOQ_1386290.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid