Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.6 Cr+₹19,902.52 (0.12%)Rejected-Finance | ₹1.6 Cr+₹19,902.52 (0.12%) | L2 | Rejected-Finance L2 |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
16 Dec 2021, 5:00 pmClosed
Superintending Engineer
Office of Superintending Engineer Construction Circle UKPJN Dehradun
Supply Installation Construction maintenance and handing over to maintenance body of Rising Main Pump House Over Head Tank Distribution System all E and M works at Tikaula Kalan Water Supply Scheme Block Narsan
2021_MDPEY_39455_1
Letter No. 6197/NIVIDA/802 dt. 30.11.2021
Open Tender
Civil Works
Item Rate
270 days
Haridwar
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Executive Engineer PIU Amrut UKPJN
₹3.5 L
Dehradun
10 Aug 2023
4 Dec 2021
18 Dec 2021
6 Dec 2021
16 Dec 2021
9 Dec 2021
7 Dec 2021
Amount
Pipe Line Work Supply of HDPE pipe including laying jointing Field testing,commissioning complete at site of HDPE (pe100 grade compound) pipe PN-6 as per IS 4984-2016 or as latest relevant code and specifications for water application including all cost of material,labourrequired,transpotation,loading,unloading& stacking etc.(Make- Appollo, Jain Irrigation, Aashirwad, Supreme, Vectus,Astral, Reliance)
63mm HDPE PE-100 PN-6
75mm HDPE PE-100 PN-6
90mm HDPE PE-100 PN-6
110mm HDPE PE-100 PN-6
140mm HDPE PE-100 PN-6
160mm HDPE PE-100 PN-6
200mm HDPE PE-100 PN-6
Supply, carting and fixing in position of following CI D/F sluice / Gate valve for flow regulation & scouring including cost of valve specials, labour & T&Pcomplete.
C.I. D/F Sluice Valves Confirming to IS: 14846-2000 ( Kirloskar or equivalent) of Pressure PN 1.0
Air valve 50 mm dia
Excavation of pipe line in soil mixed with course sand, shingle, kankar, including refilling of trenches after laying of pipe line including watering ramming etc.
House Hold connection including ( G.I pipe ferrule, brass bib cock etc) all material etc complete. Taking 100 % connection in initial Stage.
Dismantling of following type of road surfaces for laying of pipe line including sorting out of serviceable materials and disposal of unserviceable materials.
Cement concrete road
Reinstatement of following type of road surfaces after laying of pipe line including supply of all material ,labour,T&P etc complete.
Cement concrete road (1:2:4)
Constructing of following size of masonry Chamber with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand) for sluice valve,with C.I. surface box 100x100x75 mm with hinge cover fixedin RCC slab 1:2:4 cement sand and 20mm grit necessary excavation foundation concrete 1:5:10 and inside plastering with cement mortar 1:3:12 mm chambers as per type design including supply of all materials labour t&p etc complete.
(i) Air valve chamber (60X60X75 cm)
(ii) Sluice valve chamber (90X90X100 cm)
Transportation of Air Compressor, O P Unit and camp equipages, connected T&P and necessary material required for drilling up to site of work, including loading, unloading etc. complete.
Supply & shrouding of pea gravel in between bore & tube well assembly to the entire depth of tube well.
Development of TW by 250 PSI/900 CFM Air compressor as below including Erection of compressor at site of work.
Running of compressor for development and testing of tube well.
Development of TW by suitable size of OP Unit as below including Erection of OP Unit and camp equipage at site of work.
Lowering of suitable size submersible pump motor set with column pipe and running of D.G. Set, running of OP Unit for development and yield test of tube well.
Chemical & bacteriological testing of water sample
Supply of submersible pump capable of delivering 1425 Lpm discharge at 48 mt. head with suitable electric motor to be operated on 415 volt (+\- 10% ), 3 phase,50 C\s AC supply with 5 Mtr. submersible cable.
Supply of spare pumping plant as above .
Smart electrical panel cum starter suitable for automation of 30 HP capacity .
Supply of 63 amp. 3 phase with neutral main switch with enclouser and HRC fuses.
Supply of submersible cable 1x3x10 sq.mm .
Supply of aluminum armored cable 25 sq.mm 3.5 core .
SUPPLY OF MAIN PIPING AND VALVE OF 150 mm DIA HAVING FOLLOWING ITEM .
C class M S column pipe (confirming IS: 4270 or latest IS code) in 3 mt. length with interlocking arrangement (flanged/socketed) .
CI D\F PN-1.6 Sluice Valve with hand wheel .
CI D\F PN-1.6 Reflux Valve .
MS D\F pipe of 1.5 Mt. length- 2 Nos, MS D/F pipe of 1.0 Mt. length-1 No., Ventury - 1 No, Tee-1 No, CI D\F bend-2 Nos, TW Cap-1 No., Packing & nut bolt etc. - 1 Lot.
S/o 150 mm dia M.S.D.I. clamp set .
S/o Jointing material for wiring connection including lugs, thimble, insulation tapes etc.
S/o Pressure Gauges with control cock & fitting, nipple, pipe, elbow etc complete- 10Kg/Sq Cm.
Installation & testing of pumping plants and accessories.
SITC of dozing pump with all necessary connecting accessaries complete.
Testing of pumping plants at manufacture`s works.
Earthing with G.I Earth plate of 600mmx600mmx 6mm size including accessories and providing masonry enclosure with providing and fixing 25mmx5mm GI strip on surface or in recess for connections with charcoal, salt as required.
Supply of 3 ton capacity and 4.5 mt. lift chain pulley block .
Supply of rubber resistance insulated sheet 2M x 1M x 25mm thick .
Supply of three phase rolling contact servo voltage stabilizer 60 KVA capacity with input voltage range 300 to 480 with constant output of 415+/-1% complete in all respect ONAN Type.
Earthing with G.I Earth plate of 600mmx600mmx 6mm size including accessories and providing masonry enclosure with providing and fixing 25mmx5mm GI strip on surface or in recess for connections with charcoal, salt as required.
Installation, Testing & commissioning of Three phase servo voltage stabilizer.
Wiring for light point, fan point etc. with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface PVC conduit with piano type switch, phenolic laminated sheet, suitable size GI box, with earth wire of 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/sub main along with earth wire with the following size of FR PVC insulated copper conductor single core cable in surface PVC conduit as required.
2x2.5 sq. mm + 1x2.5 sq. mm earth wire
2x4 sq. mm + 1x4 sq. mm earth wire
Supply and fixing of metal box of 180 rnmx100mmx160 mm deep on surface with suitable size phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 amp and 15x16 amp socket outlet and 15/16 amp piano type switch, connections, painting etc as required.
Supply and fixing of following way S.P.N. sheet steel, MCB DB, 240 V on surface complete with copper bus bar, neutral bus bar, earth bar, inter connections including earthing etc as required. (But without MCB/RCCB/Isolator)
6 Way double door ,
Supply and fixing of 5 A to 32 A, 240 V, 10 KA, C serious MCB suitable for inductive load of following pole in the existing MCB DB complete with connection, testing etc as required.
Supply and fixing of double pole, 240 V, isolator in the existing MCB DB complete with connection, testing etc as required.
Supply and fixing of 20 W LED tube light complete in all respect (Bajaj/Philips OR Equivalent make)
Supply in fixing of LED external lighting luminaries with mounting bracket etc. complete.
O & M of pumping plant for six months
S.S ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .