Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC LANE NO 11 HOUSE NO 4 INDRAPRASTHA COLONY UPPER NATHANPUR RING ROAD DEHRADUN | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC ok | |
| 2 | L2₹29.7 L+₹32,303.38 (1.10%)Rejected-AOC | L2 | Rejected-AOC ok | |
| 3 | L3₹30.3 L+₹91,967.28 (3.13%)Rejected-AOC D 89 SHASTRI NAGAR MEERUT UTTAR PRADESH PIN 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L3 | Rejected-AOC ok | |
| 4 | L4₹30.9 L+₹1.5 L (5.20%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | L4 | Rejected-AOC ok | |
| 5 | L5₹31.3 L+₹1.9 L (6.57%)Rejected-AOC 11 CIVIL LINES ROORKEE 247667 DISTT HARDWAR UK | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-AOC ok |
Tender Value
₹43.3 L
EMD Value
₹86,660
Closing Date
28 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Dehradun
HQ CWE Dehradun
ADDNL/ALTN AND IMPROVEMENT OF JCOS/OR MD ACCN AT MH DEHRADUN
2023_MES_583399_1
9785/DDN/E8
Open Tender
Civil Works
Item Rate
180 days
Dehradun
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE Dehradun
₹86,660
Yes
13 May 2023
28 Feb 2023
30 Mar 2023
28 Feb 2023
28 Mar 2023
14 Mar 2023
Amount
Taking down chowkhats or frames n. exc 1.5 sqm each without taking off shutter from the frame complete all as specified and as directed.
All as per item No 1 here in above but exc. 1.5 Sqm but not exceeding 4 Sqm each complete.
S&F mild steel pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed.
S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed. Note for item No. 3 & 4: Cost of framed filled with cement concrete1:2:4 type B0 (12.5 mm stone aggregate) shall deemed to be included in the quoted rates.
S & F 35mm thick second class hardwood (Golden Teak) glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified and as directed.
S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side plain with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire retardant and having screw holding capacity complete all as specified and as directed.
S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing complete all as specified and as directed.
S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc. complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc. without glazing bars, dovetailed or welded complete all as specified and as directed.
S&F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc. complete all as specified and as directed.
S&F Aluminium body door cill at bottom part of door to stop entry of insect inside the room complete all as specified and as directed.
S&F stainless steel wire cloth 1.40 mm nominal dia of wire and average width of aperture 12 mm complete all as specified and as directed.
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified and as directed.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe. 290.Gde-E-165 including necessary welding, drilling hole complete all as specified and as directed.
S&F stainless steel barrel tower bolts 150 mm long one piece and fixed complete all as specified
S&F stainless steel butt hinges, medium weight 100 mm long one piece and fixed with screws/welded to frame , complete all as specified and as directed.
S&F stainless steel handles 150 mm long one piece and fixed with screws/welded to frame complete all as specified and as directed.
S&F 300 mm long stainless-steel sliding door bolt (bolt not less than 12 mm dia) with hasp & staple and fixing clips of SS sheet, and SS fixing bolts and fixed complete all as specified and as directed.
S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified and as directed.
M&L for applying two coats of Synthetic paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and as directed.
S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws and profile should match with galvalume sheet complete all as specified and as directed.
Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed.
S&F mild steel rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified and as directed.
S&F stain less grade 204 drapery rod 20mm dia including decorative brackets, decorative finals at both ends complete all as specified and as directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified and as directed.
M&L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base complete all as specified and as directed.
M&L non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4, and including dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed.
M&L glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and including dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and including dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete.
All as per item No 34 here in above but as in skirting including 10 mm thick rendering in cement mortar 1:4, complete.
Demolition of stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed. .
M&L 18 to 20 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
S&F PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified and directed.
S&F vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and directed.
S&F 10 litre capacity PVC low level cistern ‘white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified and directed.
S&F vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified and directed.
S&F pillar taps, brass, with capstan head, fancy type chromium , screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make: Jaquar/Cat part No KUP-35001PM/Hindware cat part No F370001/Parryware Cat part No T4302A2
S&F brass chromium plated overhead shower with shower arm complete all as specified and directed. Make : - Parryware Cat Part No T9985A1(Shower) & T-9999A1(Arm)/Hindware Cat Part No F160054 (Shower) & F190016(Arm)/Jaquar Cat Part No OHS 1999 (Shower) & SHA479L300 (Arm).
S&F 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make : - JAQUAR Cat Part No FON-40053/Hindware Cat Part No F160017/Prayag Cat No 9410
S&F 15mm bore Bib taps long body cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : - JAQUAR CAT Part No ALI-85037/Hindweare CAT Part No F-370004/Prayag CAT Part No S9906
S&F CP grating 100mm to 125 dia round fix on floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed.
Taking up or down steel tubing and connection incl removal from site bore of pipe 15mm complete all as specified and directed.
Taking up or down steel tubing and connection incl removal from site bore of pipe 20mm complete all as specified and directed.
S&F 15mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed.
S&F 20mm bore pipe medium grade galvanised iron with all fittings fixed to wall and ceiling or laid in floor complete all as specified and directed.
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting exc half but n exc full brick wall complete all as specified & directed.
S&F 75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified and directed.
S&F 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenches complete all as specified and directed.
S&F 75 mm bore UPVC (SWR) bend with oval access door, 'T' socket reducer etc complete all as specified and directed.
S&F 110 mm bore UPVC (SWR) bend with oval access door, 'T' socket reducer etc complete all as specified and directed.
Providing & fixing false ceiling of Designer tile Ivory painted (High Pressure Steam cured) of 4mm thickness (as per IS : 14862) of size 595x595mm and any one of the design (Cascade or electra) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel section (Galvanised @120 grms, both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 15x32mm made from 0.30mm thick sheet spaced at 1200mm c/c and cross 'T' of size 15x32mm made of 0.30mm sheet 1200mm long spaced between main "T" at 600 mm c/c to form a grid of All as per item No 136 (Contd/--) ...1200x600mm and secondary cross "T" of length 600mm and size 15x32 mm made of 0.30mm thick sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x22x0.40mm and laying false ceiling tiles in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI soffit cleats fixed to existing RCC lintel with dash fasteners, GI adjustable wire of 4mm dia with galvanised butterfly level clips, spaced at 1200mm c/c along main 'T', bottom exposed width of 15mm of all 'T'' sections of 4mm dia GI wire shall be pre-painted with polyester paint and black painted groove at center of size 4mm depth and 4.5mm width, including taking down existing ceiling of any type all complete at all heights as per direction of Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L brick work with sub class 'B’ brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of existing old brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L brick work with sub class 'B’ brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall including demolition of existing brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M & L for 15 mm thick rendering on brick work or concrete surface in cement mortar 1:6, surface finished even and fair complete all as specified and directed.
M & L 15 mm thick rendering in cement mortar 1:4 on brick work or concrete surface, surface finished even and fair complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L, preparation of wall and applying1-2 mm thick exterior grade wall care putty to make the surfaces smooth complete all as specified and directed.
M&L for preparing of old decorated surfaces and applying two coats of cement-based paint on walls complete all as specified and directed.
M&L for preparing of old plastered and un plastered surfaces of wall and applying two coats of distemper oil emulsion complete all as specified & directed.
Taking down carefully copper /aluminium point wiring (light, fan, socket or power) any type including unscrewing from board, fitting and fixture such as switches, ceiling roses, holders, regulators sockets , light fittings etc removing materials from site and making good disturbed with the existing surfaces complete all as directed.
M&L for Point wiring with1100 Volts, grade 1.5 Sqmm. (nominal area) ,PVC insulated but unsheathed multistranded copper conductor single core FRLS cable drawn through and including nonmetallic medium duty rigid PVC concealed conduit (medium duty) 20mm dia or higher size complete with all accessories such as socket, elbow, junction box, bell mouth, bend, reducer etc including pressed iron/steel modular suction box of thickness 1.2mm for mounting of switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLS, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable green colour as earth wire up to common earth and connected to earth dolly including cutting chases for conduits and sinking's for boxes and making good to walls, floors etc complete all as specified and directed by Engr.-in-charge of following.
(a) One light point /fan controlled by one way switch.
(b) One bell point, controlled by bell push switch.
(c) One three pin 5 Amp socket on same board with other switches
(d) One three pin 5 Amp socket on independent board
All as per Item No 69 mentioned here-in- before but one three pin 15 Amps switch socket out let on the independent board with 2.5 sq mm PVC insulated FRLS copper conductor and 2.5 Sqmm FRLS copper conductor for continuous earthing complete.
S&F in repairs switch modular 6 Amps 230 Volts one way switch complete all as specified and directed.
S&F in repairs Socket 6 Amps AC 230 Volts 2/3 pin combined 2 modular type complete all as specified and directed.
S&F in repairs Socket 6A/16 Amps-2/3 pin AC 230 Volts combined 2 modular type complete all as specified and directed.
S&F in repairs Switch modular type AC 230 volts 16 Amps one way complete all as specified and directed.
S & F in repairs Modular white cover plate with frame 2 module complete all as specified and directed.
S & F in repairs Modular white cover plate with frame 3 module complete all as specified and directed.
S & F Modular white cover plate with frame 4 module and metal flush box 4 module complete all as specified and directed.
S & F Modular white cover plate with frame 6 module complete all as specified and directed.
S & F Modular white cover plate with frame 8/12 module complete all as specified and directed.
S & Fix calling bell ding dong type AC 230 Volt single pole complete all as specified and directed.
S & Fix in repairs for modular type step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts, 6 Amps,100/120 watts complete all as specified and directed.
Supply and fix in repairs for ceiling rose, three terminal ISI marked surface bakelite suitable for batten fitting complete all as specified and directed.
S & Fix in repairs for lamp holder polycarbonate insulated body, with back plate suitable for Batton fitting complete all as specified and directed.
S&F wall mounted LED tube light fitting 1x10 watts, 2 feet extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
S&F wall mounted LED tube light fitting 18/20 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed.
S&F in replacement of energy saving, surface mounted, LED 10 watt Bulk head luminaire with decorative oval diffuser comprising of high brightness LEDs complete all as specified and directed.
Supply and fixing in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete pre-wired including bracket made out of 32 mm bore medium grade GI pipe made to shape with bolts, buts & washers of min 1.2 Mtr incl grouting of nuts or fasteners clamps and conductor to fitting with 3 core 1.5 sqmm PVC insulated cable complete all as specified including taking out old unserviceable fitting complete all as specified and directed.
S&F Meter Distribution board made out of Thermoplastic polycarbonate of size 600x600x170 mm (dust proof & weather proof, Shock proof, rust proof ,corrosion free ,acid & Chemical resistance ,UV resistance , Halogen free & free recyclable material) with 230v Ac 50 HZ 3 Wire , Gasket shall be embedded with T-locking arrangement and suitable for mounting of Electronic Meter -04/6 Nos including electrical connection with existing KWH meter and sealing properly & taking out of old unserviceable broken/rusted box of any size and type complete all as specified and directed. Note :- Cost of refixing of taken out serviceable meter deemed to be inclusive in the quoted rates.
S&F in replacement temper proof LCD display Digital Energy Meter, single phase, 2 Wire AC, 230V, Cap 10-60A, Push to fixed type Box with marker of qtr nos complete all as specified and directed. Note :- Old u/s electric meter will be deposited in MES store yard.
Removing & refixing as its existing position or new location the ceiling fan carefully including electric connection and arrangement of fan hooks suitable for hanging of ceiling fans complete all as specified & directed.
Supply and fix electric water heater, storage type steel body and heating element up to 2 KW of capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostat, NRV, connection pipes, fastener suitable for hanging to geyser etc complete all as specified and directed.
S&F exhaust fan, steel body AC single phase ,230 V of size 300 mm sweep with, blades, frame and louvers and connecting up ceiling source to connector block of fan including making of holes and grounting nuts and bolts PCC (1:2:4) B-1 block complete all as specified and directed.
Supply and fixing in replacement for Distribution board Vertical type TPN 4 Way double door, suitable for MCCB 63/100 Amps MCCB as incoming and MCBs for outgoing factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar. DBs shall be semi glossy finished with epoxy polyester-based powder paint sprayed and baked at high temperature, painted in seven tank process. The DBs shall be of IP 43 protection including taking out old unserviceable distribution board. Note:- DB and MCCB/MCB shall be of same make and shall be paid separately
Supply and fixing in replacement for Distribution board TPN 4 Way double door, for mounting MCBs/isolator, etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make
Supply and fixing in replacement for Distribution board SPN 8 Way double door, for mounting MCBs/isolator, etc factory made, IS: 13032 marked with valid CM/L No fabricated out of CRCA sheet not less than 1.2 mm thick fitted with DIN channel, neutral and earthing link and bus bar complete all as specified and directed. Note:- DB and MCCB/MCB shall be of same make
Supply and fix in repairs MCCB 63 Amps FP 415 Volts having breaking capacity 16 KA with and incl spreader link kit complete suitable for fixing as incoming in polycarbonate busbar complete all as specified and directed.
S&F in repairs MCB TPN 240 Volt 10 KA 63 Amp 'C' series conforming to IS complete all as specified & directed.
S&F in repairs MCB SPN 240 Volt 10 KA 32 Amp 'C' series conforming to IS complete all as specified & directed.
S&F in repairs MCB single pole 240-volt, 10 KA, 5-32 Amp, 'C' series confirming to IS complete all as specified and directed.
M&L for sub main wiring in repairs with 2 Single core PVC insulated unsheathed cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm (nominal area) drawing in and including 25 mm dia or higher medium duty PVC concealed conduit/flexible conduit where required and conduit accessories and fittings. Including one single core green colour PVC Insulated unsheathed cable copper conductor multistranded of size 6 Sq mm as earth wire upto common earth and connected to earth dolly complete including taking out old unserviceable submain wiring complete all as specified & directed.
Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized wire 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 15 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 5 of SSR part 1 including testing on completion all as specified and directed. including demolition to existing earthing complete all as specified & directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor 1100 volts grade, cross sectional area size 25 Sqmm 4 Core complete all as specified & directed.
Supplying, laying, testing and commissioning of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) with aluminium conductor 1100 volts grade, cross sectional area size 16 Sqmm 4 Core complete all as specified & directed.
Excavation in trenches n exc. 1.5 m wide and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling of excavated soil, including spreading leveling, watering and well ramming in layers, not exceeding 25cm complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete.
Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable) and gently punned down to 18cm thickness all complete all as specified and directed. Note:- Only punned down sand thickness 18CM shall be measured and paid.
Supplying and laying old size bricks, laid flat ie length of brick shall be laid across the cable, common burnt clay building bricks sub class `B' designation 75 complete all as specified and directed and testing on completion complete all as specified and directed.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 50 mm dia for cable protection complete all as specified and directed.
M/S JAI PRAKASH GOEL
MOHAN LAL GUPTA
PRAGATI ENTERPRISES
Alankar Traders
m/s rajesh bros.
M/s RP AGRAWAL
kalakriti enterprises
M/s RK ENTERPRISES
M/s RAM RATAN AND SONS
SARASWATI CONSTRUCTION CO
BALAJI AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .