Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance SAHU THEATRE BUILDING HAZRATGANJ LUCKNOW LUCKNOW UTTAR PRADESH 226001 | LUCKNOW | UTTAR PRADESH | 226001 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹8.5 L
EMD Value
₹86,000
Closing Date
12 Mar 2024, 3:00 pmClosed
EE Mentenance Section HQ
UPHDB 104 MG Road Lucknow
Providing, Installation, Commissioning and Testing of LG / O General / Mitsubishi Electric make Cassette Air Conditioner 05 No. Of 3 Tr. capacity i/c dismantling of old units and entertaining the buyback value
2024_UPHDB_902093_1
85/Maint HQ dated 14.02.2024
Open Tender
Miscellaneous Services
Item Wise
60 days
Mentenance Section HQ
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE Mentenance Section HQ
₹86,000
21 Mar 2024
21 Feb 2024
14 Mar 2024
21 Feb 2024
12 Mar 2024
21 Feb 2024
Amount
Supply of air cooled Eco friendly Split Type Ceiling Mounted 4 Way Cassette inverter type Air conditioner units,suitable for cooling by inverter driven capacity control Twin Rotary Invertor Compressor,Supply of BLDC Motors in Indoor and outdoor unit along with individual controller with fittings ,Outdoor units panels along with aluminium fins shall have factory applied (Anti corrosive coating +Hydrophilic Coating),Compressor should be of same make ,havng 5 star rating for the below units mentioned. , Dual sensors based (Temperature and Pressure) operation, Copper condenser & Evaporator coil, Single phase .Factory charged ecofriendly refrigerant R32 refrigerant. Suitable for high ambient application upto 53 Deg C. Refrigerant control should be through electronic expansion valve.
3.0 TR Cassette AC
Installation, testing and commissioning of Cassette AC.
3 TR Cassette AC
Supply, installation, testing and commissioning of interconnecting refrigerant copper pipe work suitable for R-410A refrigerent with (19 mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor and outdoor units , all piping inside the room. All piping shall be properly supported with MS,GI STUDS/CLAMPS/HANGERS. All pipe shall be pressure tested for 1.5 times the working pressure . The refregerant pipes running in vertical shaft shall be supported on MS angle and saddle at every 1200 mm distance and the pipes which are running horizontally above the false ceilling should be supported on MS angle/slotted angle at every 1200 mm distance complete in all respect.
Supply, installation, testing and commissioning of hard PVC drain piping complete with fittings, supports, valve and 6 mm thick closed nitrile rubber foam insulation commplete in all respect as per site requirement.
32 mm dia
Supply, installation, testing and commissioning of 2C x 1.5 sqmm control cum transmission wiring/power/control cabling with PVC insulated, PVC sheathed, multicore copper conductor control cable in suitable conduits between indoor and outdoor unit
Supply, and errection of Outdoor MS Stand /Mounting with vibration isolation pads, complete in all respects as per site requirement.
Buy Back value of 05 No old dismantled cassette Air Conditioner from building.
Note:-GST paid extra as applicable
M/S SS REFRIGERATION AND INFRA PRAMOTORS PVT LTD
UURJAVARAN
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .