Loading…
Loading…
Tender Value
₹12.3 Cr
EMD Value
₹12.3 L
Closing Date
15 Jun 2026, 6:30 pm
Vice President, (P), GUDC Ltd., Gandhinagar
Vadnagar Cattle Shed under SJMMSVY (3rd Invitation) : Vadnagar Cattle Shed under SJMMSVY: “Design, Development and construction of Cattle Shade with Electrification, Framed Shed, Water Supply, Compound & Retaining wall, RCC Road, Office other Buildings, Sign Board, Sound and CCTV System, Incinerator for animals and various Artefacts etc. Including 03-[Three] Years Defect Liability Period for Vadnagar Nagarpalika, Tal: - Vadnagar, Dist.: Mehsana, Gujarat” Under SJMMSVY on EPC Basis
310310
GUDC/PROJECTS/SJMMSVY/Vadnagar/Cattle Shed
Open
Civil Works - Others
Gandhinagar
3 documents required · 3 mandatory
₹21,240
GUDC Ltd., Gandhinagar
₹12.3 L
1 Jun 2026
1 Jun 2026
1 Jun 2026
15 Jun 2026
1 Jun 2026
1 Schedule B-1 Construction of RCC Road
Earthwork, Brickbat Chara filling at open area and Paver
3 Schedule B-3 Construction of Compound Wall
4 Schedule B-4 Construction of Retaining Wall
5 Schedule B-5 Entry Gate Including Sign Board
6 Schedule B-6 Security Room and Control Panel Room
7 Schedule B-7 SLTC of Solar Street Light Work & High Mast Work
8 Schedule B-8 Percolating Well
9 Schedule B-9 Development of Garden and Plantation
10 Schedule B-10 Veterinary Hospital
11 Schedule B-11 Office Building
12 Schedule B-12 Milk Processing Unit
13 Schedule B-13 Soakpit & Septic Tank
14 Schedule B-14 Tube Well of 250 mm Dia. Depth 300 Rmt
15 Schedule B-15 Furniture arrangement at different Building
16 Schedule B-16 Electrical and Instrumentation Work
17 Schedule B-17 Construction of Various Shed
18 Schedule B-18 Cow Urine Collection
19 Schedule B-19 Water Distribution Network & Connection at Each Pit
21 Schedule B-20 SITC of Sound System
22 Schedule B-21 SITC of CCTV Camera System
Provision of Sculpture, Statue, Benches & Various artifects
23 Schedule B-22
Design, supply, install and commission a 1 Ton Double
24 Schedule B-23 Chamber Animal Incinerator System with pollution control
and CPCB compliance on turnkey basis.
Total Net Cost (In Rs.)
Construction of RCC Road
Description Unit Quantity Rate Amount
Clearing and grubbing road land including uprooting rank vegetation grass
bushes,shrubs,sapling and trees girth upto 300 mm removal of stumps of
trees cut earlier and disposal of unserviceable materials (A) By manual
means in area of light jungle
Box cutting the road surface to proper slope and camber for making a base
2 for road work including removing the excavated stuff and depositing on the cum 2608.88 109.05
road side slope as directed upto 50Mt.lead.
Supplying of graded stone aggregate of following sizes (for W.B.M. Road)
(2) Hand broken stone aggregate 40 mm to 63 mm size.
Spreading the stone aggregate for rolling and W.B.M. including filling the
4 interstices to required camber and gradient (excluding spreading of cum 1159.50 261.94
Blindage) (ii) 40mm to 63mm size aggreagates (H.B.)
Rolling and consolidating water bound macadam (W.B.M) (except laterite
and Kankar) including watering with required thickness (Main layer
5 including binding materials) including filling in depressions which occur sqm 1159.5 22.02
during the process. (A) With power roller exceeding 8 tonne and not
exceeding 12 tonne.
Providing and laying cement concrete 1:3:6 (1‐Cement : 3‐ coarse sand : 6‐
6 hand broken stone aggregates 40 mm nominal size) and curing complete cum 579.75 2,968.91
excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and laying controlled cement concrete M.200 and curing
complete excluding the cost of formwork and reinforcement for reinforced
concrete work (A) Foundations, footings, Base of columns and Mass
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete.
Total cost (in Rs.)
Earthwork, Brickbat Chara filling at open area and Paver Blocks at Road
Description Unit Quantity Rate Amount
Earthwork for embankment including breaking clods, dressing with
all lead and lift and including watering rolling and consolidation of
1 subgrade in layers at O.M.C. to required dry density including Cumt. 14420.00 201.81
filling the depression which occur during the process using power roller
8T to 10T. (E) From Borrow area within 6 km lead
Excavation for foundation upto 1.5 m depth including sortingout
2 and stacking of useful materials and disposing off theexcavated stuff Cumt. 151.00 268.21
upto 50 meter lead (C) Hard Murrum
Add extra for Disposing off the excavated stuff of above items for lead of
Add extra for Disposing off the excavated stuff of above items for lead of
Add extra for Disposing off the excavated stuff of above items for lead of
Filling in foundation and plinth with brick Bats Chhara in layers of
3 20cm. thickness including watering, remming and consolidating etc. Cumt. 336.00 621.46
Lime Mortar 1:1 (1-lime putty / Equivalent dry Hydrated Lime : 1-Fine
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete
block 60mm thick with grade of concrete M300 pnumatic compressed /
vibrated mechanically and as per approved design Confirming to IS
15658 : 2006 including 35 mm Sand layer for levelling and filling the joint
with sand in proper line and level as per guidlines of IRC : SP 63-2018 etc.
Providing and fixing pre-cast concrete kerb stone of gray cement
based concrete block 30cm length,30cm height and 15cm thick of
6 M300 grade concret as per approved design and including excavation Rmt 510 404.05
for fixing in proper line and level,filling the joint with C:M 1:3
(1cement:3fine sand) etc complete.
Providing & laying spreading and compacting 200mm thick WBM Grade -
I of B.T.M.C. metal 45mm to 90mm size including using 29% (22+7%)
filler i.e. stone screeing 13.2 mm at the rate 0.27 Cumt. & stone dust
at the rate 0.08 cumt. including spreading in uniform thickness,
hand packing, rolling with vibratory roller 8-10 tonnes in stages to
proper grade and camber, applying and brooming type of
screning/binding materials to fill up the interstices of coarse
aggregate, watering and compacting to the required density.
Total cost (in Rs.)
Construction of Compound Wall
Description Unit Quantity Rate Amount
Excavation for foundation including all safety provision using site rails and
1 stacking excavated stuff up to a lead of 90 mtr. Cleaning the site etc. cum 367.24 102.35
Completed. In all sorts of soil and soft murrum
Add extra for Disposing off the excavated stuff of above items for lead of
Add extra for Disposing off the excavated stuff of above items for lead of
Add extra for Disposing off the excavated stuff of above items for lead of
Providing and laying cement concrete 1:3:6 (1 Cement : 3 Coarse sand :
2 Hand Broken stone aggregates 40 mm nominal size) and curing complete cum 84.93 2,968.91
excluding cost of formwork in Foundation and Plinth
Providing and laying controlled cement concrete M.200 and curing
3 complete including the cost of formwork and including the cost of cum 56.00 4,337.95
reinforcement for reinforced concrete work in (A) Foundation & Footing
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and including the cost of
reinforcement for reinforced concrete work in (D) Columns, Pillars posts
and struts upto floor two level
Providing and laying controlled cement concrete M.200 and curing
complete including the cost of formwork and including the cost of
5 reinforcement for reinforced concrete work in (C) cum 64.84 6,614.49
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and Cantilever upto
floor two level.
Providing and laying controlled cement concrete M.200 and curing
6 complete including the cost of formwork and including the cost of cum 21.62 6,614.49
reinforcement for reinforced concrete work for Coping at Top of Wall
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete.
Brick work using common burnt clay building bricks having crushing
strength not less than 35 kg./Sq.Cm. in foundation and plinth in Cement
Mortar 1:6 (1‐Cement : 6‐fine sand) and conventional extra for brickwork
in superstructure above floor to level
20 mm thick sand faced cement plaster on walls upto height 1.5 metres
above ground level consisting of 12 mm thick backing coat of C.M. 1:3 (1
cement : 3 sand ) and 8 mm thick finishing coat of C.M. 1:1 (1Cement :
Sand ) etc. complete.
Refilling including ramming, watering, consolidating disposal of surplus
stuff as directed within a radius of 3 kms
Finishing wall with water proofing cement paint of on wall surfaces (Two
coats) to give an approved brand and manufacture and of required shape
11 even shade after thoroughly brushing the surface to remove all dirt and Sqm 4065.00 71.86
remains of loose powered materials and extra for every subsequent coat
of finishing with cement paint on ceiling and sloping roofs.
Description Unit Quantity Rate Amount
Providing and Fixing 'Y' Shaped Barbed wire fencing on compound wall top
with verical angle of 50x50x6 mm x 0.60 Mtr height, two cross angles
50x50x6 mm x 0.45 Mtr. Length, having 2 Horizontal and 2 diagonal rows
of barbed wire(9.38 kg/100 rmt) on two cross angle incl. cost of barbed
wires, necessary GI stapplings, fixing in Coping on top of compound wall,
painting angles with one coat of anticorrossive primer and two coats of
enamel paint of approved quality, necessary scaffolding etc. complete as
per the direction of the Engineer in Charge.
Providing and fixing 1 mm thick M.S. sheet sliding shutters with frame and
diagonal braces of 40 x 40 x 6 mm angle iron, 3.15 mm M.S. gusset plate at
junctions and corners 25 mm dia pully 40 x 40 x 6 mm angle and T‐iron
guide rail at top and bottom respectively with handles, stoppers and
locking arrangement etc. including applying a priming coat of red lead
Painting two coats (excluding priming coat) on new steel and other metal
surface with synthatic enamel paint, brushing to give an even
shade,including cleaning the surface of all dirt, dust and other foreign
Total cost (in Rs.)
Construction of Retaining Wall
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5 m depth including sorting
1 out and stacking of useful materials and disposing off the cumt 288.00 432.08
excavated stuff upto 50 Meter lead.g (C) Hard Murrum
(i) Uncoursed Rubble Masonry with hard stone of approved quality in
2 foundations and plinth in Cement Mortar 1:6 (1- cement : 6-coarse cumt 20.16 2,523.34
sand including levelling up etc. complete
Providing & casting in situ ordinary cement concrete M-100 mix and
providing necessary pin headers including shuttering, scaffolding, laying,
vibrating, curing and finishing complete with V-Groves.(A) Height from
Providing and laying controlled cement concrete M.250 andcuring
complete excluding the cost of formwork andreinforcement for
reinforced concrete work in (A) Foundations,footings, Base of columns
and Mass concrete.
Providing and laying controlled cement concrete M.250 and curing
complete excluding the cost of formwork and reinforcement for
reinforced concrete work in (B) Walls, from top of foundation level upto
floor two level.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
6 bending, binding and placing in position complete Kg 35424.00 77.29
upto floor two level
Providing fusion bonded Epoxy coating not less than 175 micron
thickness and up to 300 micron to reinforcement bars as per IS-13620-
1993/ASTM-775 M including testing of coating at plant and all taxes
(A) 10mm to 16mm dia bar
Filling available excavated earth (excluding rock) intrenches. plinth,
sides of foundations etc. in layers notexceeding 20 cm. in depth
consolidating each dispositedlayer by ramming and
Providing formwork of ordinary timber planking so as to give arough finish
including centering shuttering strutting and proppingetc. Height of
propping and centering below supporting floor to
9 ceiling not exceeding 4 M. and removal of the same for in Sqmt 192.00 181.85
situreinforced concrete and plain concrete work in. (A)
Foundations Footings Bases of Columns etc. and Mass
Providing formwork of ordinary timber planking so as to give arough finish
including centering shuttering strutting and proppingetc. height of
propping and centering below supporting floor to ceiling not
10 exceeding 4 M. and removal of the same for in situreinforced concrete Sqmt 960.00 258.28
and plain concrete work in. (C) Verticalsurface such as walls (any
thickness) partitions and the likeincluding attached buttresses & string
course & the like
Total cost (in Rs.)
Entry Gate Including Sign Board
Description Unit Quantity Rate Amount
Providing & fixing M.S. grills of required pattern to wooden frames
of windows etc. with M.S. flats at required spacing and frame all-
round square or round bars with round headed bolts and nuts or by
screws. (B) ORNAMENTAL GRILL
Applying priming coat of over new steel and other metal surface after and
including preparing the surface by thoroughly cleaning, oil grease, dirt
2 and other foreign mater and scoured with brushes fine steel wool, Sqmt 47.50 36.87
scrapers and sand paper with ready mixed priming paint brushing red
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brusing interior to give an even
shade including cleaning the surface an even shade including cleaning
the surface of all dirt, dust and other foreign matter.
Providing & Fixing Sign Board Made out of 50-75 mm thick Real Wood
Including Cost of Hand/ cnc Carving Letter As per Instruction Given
4 By Nagar Palika. The Item Include Cost of Alll Kind Of Material Nos 2.00 62,500.00
Polishing Work Weather Proof Treatment Hanging Fixures Etc All The
Size Of Board Should Be 600 x 1200 mm
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure
die cast aluminium housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and Polycarbonate optics/
lenses with company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED
driver efficiency > 85 %.( fittings required LM-79 & LM-80
certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) Cat III - Above 24 To 36 Watts
Excavation for foundation upto 1.5 mt. Depth including sorting out and
6 stacking of useful materials and disposing of the excavated stuff upto 50 Cum 3.18 157.08
meter lead. (B) Dense or Hard Soil (For Footing)
7 (C) Hard murrum Cum 3.18 268.21
Providing and laying cement concrete 1:3:6 (1-Cement : 3- Coarse sand : 6 -
8 Hand broken stone aggregates 40 mm nominal size) and curing complete. Cum 0.58 2,968.91
Excluding cost of form work in Foundation and plinth.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
Description Unit Quantity Rate Amount
Providing and laying cement concrete work 1:2:4 (1 : cement, 2:coarse
sand, 4: graded stone aggregates 20 mm nominal size) and curing
10 complete excluding cost of form work and reinforcement for reinforced Cum 1.09 3,875.94
concrete work in
(A) Foundation, footing, base of columns and mass concrete.
11 (D) Columns,pillars,posts and struts up to floor two levels Cum 2.30 3,971.75
Providing formwork of ordinary timber planking so as to give a rough
finish including centering,shuttering, strutting and proping etc. height of
proping and centering below supporting floor to ceiling not exceeding
mt. And removal of the same for in situ reinforced concrete and plain
concrete work in
(A) Foundation, footing, base of columns and mass concrete.
(G) columns, pillars, posts and struts (square, rectangular, polygonal in
Providing 15 mm thick cement plaster in single coat on brick / concrete
14 walls for interior plastering upto floor two level and finished even and Sqmt 11.22 165.31
smooth in Cement mortar 1 : 4 (1: Cement, 4: Sand)
finishing wall with water proofing cement paint of on wall surfaces(Two
coats) to give an approved brand and manufacture and of required shape
even shade after thoroughly brushing the surface to remove all dirt and
remains of loose powered materials.
Total cost (in Rs.) =
Security Room and Control Panel Room
Description Unit Quantity Rate Amount
Security & Panel Room:
Designing (aesthetically) and constructing R.C.C frame structure of Without
Gantry structure (Upto 3.60 M)
1 1. Minimum 15 % opening for ventilation should be provided. Sq.mt 12.25 11,920.53
2. Pump room rolling shutter, door and windows of aluminium section
and window grill of iron should be provided (Included in Cost).
3. Plinth level of Pump house should be min.1 meter above GL.
4.Cost does not include foundation for pumping machinery.
Total cost (in Rs.) =
SLTC of Solar Street Light Work & High Mast Work
Description Unit Qty Rate Amount
Supplying and erecting approved make Octagonal pole made from HR sheet steel. The pole
should be made as per IS. and shall be coated with hot dip galvanizing as per IS
2629/2633/4759, suitable suspend local wind speed with integral Junction box consist of
terminal plate of min 12mm Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB
Mounting, stud type terminal and arrangement for cable termination to be erected on suitable
foundation as per detils given by manufacturer considering site requirment. (E) 7 Mtr. Long
mm Top X 135 mm bottom dia, 3 mm thickness with 225mmX225mmX16mm base plate, 4-M20
Bolts and 600mm long with necessary G.I. J Bolts .Approx Pole weight 67 kg
Providing & Fixing of Solderless Crimping Type Aluminium Lugs (4 Nos. per termination)
conforming to IS suitable for 1 x 4.0 Core x 16 Sq. MM PVC Insulated Aluminium Armoured cable
evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. - (8 Nos. per St. Light Pole)
Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA
3 breaking capacity & confirms to IS : 8828 in existing box having following capacity.(A) 6 to 32 Each 60.00 268.13
Amp. Cat.III - (1 No. Per St. Lght Pole)
Providing and erecting Pipe type earthing having 150cms. long and 2.5cms dia. galvanised iron
pipe with coupling and buch buried in specially prepared earth pit complete with necessary
4 SWG earth wire. required size HOT deep Galvanised iron strip for earthing of H.T., OCB/ACB/ Job 60.00 613.02
Transformer LT panel board, Motors etc. using proper clamp. For using salt and charcoal / coke
as required for pipe type earthing.
Providing and erecting Street Light pole bracket comprising main B Class GI pipe of
cm/require outside dia. complete with suitable B Class G.I. sleeve tubing of approx.
45cms.length and suitable for 76.5 mm /80mm / required size of pole top having sufficient
5 fasteners for fixing the brackets and having spread of 1.5.mtr. length with 110 deg.with vertical Each 60.00 677.43
plane & suitable welded stays, reducer and with check nuts complete painted with one coat of
Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following nos of
arms. [A] Single Arm Bracket 1.5 Mtr (1 No. Per St. Light Pole)
Supplying and erecting LED Solar street lights with High power White LEDs wattage of 1Watt
and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High
pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded
6 aluminium with diffuser and Polycarbonate optics/ lenses with company mark/name engraved Each 60.00 35,797.00
or embossed with 36 hours battery backup & MPPT 24V,7.5 A charge controller with 12 hours
automatic switch on/off with wind speed resistance 44 m/s as per IEC
E) 36W,3000 lumens, IP-65, PV Module – 2x100W and 6 mtr poles complete erected
Supplying and erecting Flexible FR PVC insulated multi strand multi core 1.1 kV grade ISI Marked
7 Copper wires of 2.5 Sq. MM.,3 core round PVC sheathed in exising pipe/ in street light pole Mtr 660.00 73.02
erected with green colour for earth continuity.
Providing & erecting of 1 x 4.0 Core x 16 Sq. MM, XLPE (IS: 7098 (i) - 88), ISI Mark, Armoured
cable, Multistranded Aluminium Conductor suitable for 1.1 kV grade to be laid on wall with
necessary clamps or to be laid 90 Cms underground in existing cable trench/ pipe at road
crossing or on floor and making the ground as per original. - For Streetlight between two poles &
Service Connections.(Considering 25 Mtr. Distance between two poles and extra cable for loop =
Providing & laying of approved make 50 MM outer dia Doubled Walled Corrugated Pipes (DWC)
of polyethylene (conforming to IS 14930 - II) with necessary connecting accessories like coupler,
Tee, L - Bow, etc. of same material at required depth (90 cms) for laying of cable below ground/
road surface for enclosing cable and back filling the same to make ground as per original & as
per instruction of Engineer Incharge - for Streelight Cable of 1 x 4 core x 16 Sq. MM. (30 Mtr Per
Between two Pole)
Description Unit Qty Rate Amount
Providing & laying of approved make 90 MM outer dia Doubled Walled Corrugated Pipes (DWC)
of polyethylene (conforming to IS 14930 - II) with necessary connecting accessories like coupler,
Tee, L - Bow, etc. of same material at required depth (90 cms) including excavation for laying of
cable below ground/ road surface for enclosing cable and back filling the same to make ground
as per original & as per instruction of Engineer Incharge - for Streelight Cable of 1 x 4 core x
Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding
power supply by making up to 100mm dia.size of holes at both ends complete.
Making trench in soft soil of suitable width of 90 cm deep for laying cable or locating the fault
all over the run and back filling the same and making the surface as normal ground.
Painting the number and words for inventory Identification on erected fittings / equipment’s or
13 Such accessories as may required with good quality of enamelled paint as directed by engineer Each 60.00 22.09
in charge(i) up to 20 characters, up to 50 mm height.
Providing and erecting Three Phase IoT GSM/GPRS Central Control & Monitoring System (CCMS)
Panel for Streetlights Smart Feeder Panel with 3 Phase GSM/GPRS CCMS Streetlight Controller
with LCD Display (1 Nos.). Streetlight Controller with Individual each Phase Control (Energy
Saving feature) and Spare relay facility. Streetlight Controller having 10 years of reserved
battery for RTC. With 50 programmable schedule, month-wise offset settable facility,
Astronomic sunrise/sunset time programming in-built for year long schedule. Operating Voltage
@ 440 V AC with Over Voltage & Short Circuit protection. 2 hour Battery Back-up for Streetlight
Controller. Panel to have 1 Nos. of 3 Phase – Class 1 Energy Meter for Energy & Fault monitoring
on CCMS Web Dashboard. Panel consisting of 3 Nos. of 3 Pole Contactors (3 x 18 A), 7 Nos. of
Pole Miniature Circuit Breakers (32 Amp.) for Bypass, Input / Output supply functionalities,
Nos. of 4 Pole Earth leakage circuit breaker for safety protection. Standard lock & key facility for
Panel security.
Door Switch for unauthorized access & tamper detection. Accelerometer for panel movement
detection & tamper alerts. Suitable amount of Wires, Connectors, Terminal Blocks included in
Panel. 16/18 gauge M S with industrial exterior powder coated PP with seven tank process RAL
7035 All weather-proof Enclosure Panel having IP65 rating. Waterproof Glands & Grounding
Stand included. Dedicated IoT communication GSM/GPRS SIM Card (with minimum 5 years of
recharge) for Wireless Communication with CCMS Web Dashboard. 5 Years Data Hosting &
Server Charges to be included with CCMS Web Dashboard. Load status, Live analytics, Energy
Meter monitoring (Parameters such as kW, kWH, PF, I, V), comparative analytics, reports
generation facility. Fault detection on web dashboard. GIS Mapping of CCMS Panel on Web
Dashboard. Secured MQTT Communication for Cloud. Includes Android & iOS Mobile
Application. Local communication facility via Mobile Application in case of GPRS connectivity
Providing & erecting Approved make Four pole moulded case circuit breaker having breaking
capacity ICU of 25 KA. at 415 V,having normal current rating up to 25 A to 100A. with Fixed
15 thermal & magnetic release suitable to work on A.C. supply 50 c/s. with all internal connections Each 1.00 6,113.28
& complete erected in existing 16 G.M.S. housing. (Cat - III) suitable to work on AC supply with
all internal connection-ICS=100% of ICU only.(1 No. per Distribution Box)
Providing & Fixing of Heavy Duty Flange type Double Compression brass double Compression
type Cable Gland with rubber ring suitable for 1 x 4.0 Core x 16 Sq. MM PVC Insulated Alu.
Armoured cable complete with outgoing tails, insulating taps etc. - (3 Nos. Glands per
distribution box).
Providing & Fixing of Solderless Crimping Type Aluminium Lugs (4 Nos. per termination)
conforming to IS suitable for 1 x 4.0 Core x 16/25 Sq. MM PVC Insulated Aluminium Armoured
cable evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (12 Nos. Lugs per Distribution Box).
Description Unit Qty Rate Amount
Supplying & erecting in earthpit of minimum bore dia. 150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50 mm having 80-200 Micron galvanising, Inner pipe
dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12 mm with
constant ohmic value surrounded by highly conductive compound with high charge dissipation
suitable for following type of applications with chamber and heavy duty cover.(approved make
OEM has to submit test certificate including value of earth resistane of installation.) & having
18 back filling compound of (B) Inner Chemical (CCm Compound) - Resistivity :- 0.2 Ohm/meter Each 1.00 8,556.73
testing as per IEC 62561-2017 , Voltage Drop :- < 1 volt at no load & dry form , Sulpher content :-
<2% .(C) Back filling copound :- Earthing compound should be capable to retain moisture for log
time. Necessary test report must be submitted.
(C) For Electrical Installation covering Transformer Neutrals, Lightning arrester Earthing,
A.C.Plant & Sensitive Computer System (like Automation, SCADA) i.e. independent Earthing
located in other than normal soil i.e. Soft Rock, Marshy Soil etc..-Length of Pipe : 3 Mtrs. -Back
filling Compound :2 nos Bags of 25 Kg.- (1 Job per Distribution Box)
SITC of 16 Mtr. - M.S. polygonal High Mast with following accessories.( Item no. a to g)
Supplying, erecting, testing, commissioning approved make M.S. Polygonal High Mast Pole
having following general Specification.
(a) Polygonal Section fabricated from M.S. Plate confirms BSEN 10025 & Hot deep galvanized
minimum 65/86 micron (as per IS 2629 /1985) Lantern carriage with ring and rubber lines for
erection of luminaries of suitable site.
(b) Maximum telescopic section not more than four
(c) Double drum gear pipe motorized winch with 6mm dia S.S. Rod (For 16 mtr and above size)
(d) Approved make L.E.D. aviation light = 1 No. Lightening arrestor = 1 No. with necessary wiring
of 2.5 sq.mm 5 core ISI copper cable Unarmoured.
19 (e) Bottom most section suitable for mounting reversible motor and switchgears having door Each 1.00 1,71,574.17
not more than 1400mm x 300mm with waterproof gasket & hinges & locking arrangement.
(f) Pole structure comprises suitable size of reversible motor, cable and necessary switchgears
with control panel.
(g) bottom section shall have suitable size of thickness supports ribs foundation bolts nuts etc.
(h) Item not comprises the cost of lanterns.
(i) Necessary Cement Concrete foundation as per IS including testing & commissioning of the
entire structure for following size of High Mast poles
[3] High Mast 16 Mtr. TOP A/F 150 mm, BOTTOM A/F 450 mm, No. of Sec. No. - 2, Bottom
Thickness - 4 mm, Top Sec. 3 mm, Size of Base Plate - dia.560 mm x 20 mm thick, Foundation
Bolt Size M24 x 880 mm, Qty - 8 Nos., Suitable for mounting Fitting of Light - 8 Nos.
Supplying and Installation of Approved make Integrated LED Solar light fitting comprising in built
Poly crystalline solar panel,Lithium-ion 3.7 V battery, LED CRI Greater than 70, CCT-6500K,
lum/watt all housed in Extruded Aluminium body,with motion sensor & auto on -off device
20 erected on existing pole with following specifications. Each 8.00 9,848.85
(A) 6 watt LED light, with 7 W Solar panel, 3.7 V 13000 to 15000 mAh battery, 450 lm luminus
flux, suitable for mount on 3 mtr height pole.
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable multistrand / Solid Aluminium
conductor for 1.1 KV. to be laid on wall with necessary clamps or in existing trench / pipe of
following size of cables (C) 4 core 10 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber ring for PVC insulated
armoured cable complete with out going tails, insulating tape etc for following size of cables. (D)
2 to 4 core 16 Sq. mm
Description Unit Qty Rate Amount
SITC of Solder less crimping type Aluminium lugs conforming to IS suitable for cable of following
size evenly crimped with high pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner. (C) 16/25 Sq.mm.
Providing & laying approved make Double walled corrugated pipes (DWC) of
polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material
24 at required depth in existing trench for laying of cable. below ground / road surface for Mtr 750.00 62.09
enclosing cable (A)50 mm outer dia
Drilling the road without breaking the road surface (Asphalt) for laying of cable for feeding
power supply by making up to following size of holes at both ends complete. (B) Up to 150 mm
providing and erecting Approved make RCCBs conforming to IS: 12640 and having sensitivity of
30 mA and Short Circuit withstand capacity of 10 KA and suitable for operation on single phase
240 V,50Hz. having characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component. for following Max. rating erected as directed (ii)
40Amps. DP ( Cat. III)
Providing and erecting AC-3 duty 3 pole power contactor with 2 NO & 2 NC aux contacts
complete with 415V/220V operating coil suitable for (L&T, BCH,T.C., Siemens, C&S make). (B)
for 40 A rating
Providing & erecting 415V MCB Four Pole Switch for Lighting Load (B curve) having 10KA
breaking capacity & confirms to IS :8828 in existing box having following capacity (b) 40 Amp.
Supplying & erecting earth pit of minimum bore dia.150mm size approved make Earthing
Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I. Pipes having Outer pipe dia of 50mm having 80-200 Micron galvanising, Inner pipe
dia of 25 mm having 200-250 Micron galvanising, connection terminal dia of 12mm with
constant ohmic value surrounded by highly conductive compound with high charge dissipation
suitable for following type of applications with chamber and heavy duty cover. (A)(approved
make OEM has to submit test certificate including value of earth resistance of installation duly
stamped and signed by agency and officer In charge has to ensure the value of Earthing
resistance mentioned in test Certificate) & having back filling compound of (B) Inner chemical
(CCM Compound)- Resistivity:- 0.2 ohm / meter testing as per IEC 62561-2017, Voltage drop:- <
1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill Compound :- Earthing compound
should be capable to retain moisture for long time Necessary test report must be submitted by
Agency. (a) For Electrical Installation up to 440V in normal soil Length of pipe - 1 Mtr Back filling
compound - 1 Nos Bag of 15 Kg. with Providing and erecting Pipe type Earthing with 40 mm dia
2.5 mtr long 'B' grade G.I. pipe with necessary coupling buch buried in specially prepared earth
pit & G.I. earth wire of 8 SWG erected & connected as directed (For panel) and Providing and
erecting HOT deep Galvanised iron strip wire 8 to 16 SWG.
Description Unit Qty Rate Amount
Supplying & erecting IP 55 grade following size section pillar fabricated from joint less M.S.
Sheet with angle iron legs made from joint less M.S. Angle with cable clamps to be buried in
ground to have appropriate erection to work uniform until erected with cement concrete
foundation and 45 cm high bricks work finishing with plaster etc. hinged double door internally
supported on both side, with internal and outside looking arrangement with look and keys in
duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos. one is welded and other with nut and bolt for
erecting Bakelite sheet. Painting the Section Pillar inside and outside with three tank powder
coated paint. section pillar roof should be without joint with water leakage proof & tested as
per IP 55 test & followed by IS 2147 of
(B) 75 X 60 X 45 cm section pillar fabricated from 16 Gauge MS Sheet with angle iron legs 45 cm
long made from 35 X 35 X 5 mm thick MS angle.
Supplying and erecting HYLAM sheet on existing angle iron frame.for following thickness (F)
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative
and operate battery backup 1 channel day clock with 14 memory programme, suitable to
operate on 240V + 5%, 16A with, floating contacts Minimum switching setup time 1 minimum &
32 LCD display. Also comprised permanent ON/OFF switching. Programming switches & housed in Ea 1.00 3,137.44
fire proof thermoplastic enclosure & transparent cover erected as required with necessary
connection erected as directed.
Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or required depth for
laying any size of cable or locating the fault all over the run and back filling the same and
making the surface as normal ground..
Providing , erecting , fabricating the M.S. structure as per requirement on site incorporating
proper size of M.S. angles,square,round, flats, bars, channels, sections complete with cutting,
welding, grinding & finishing duly painted with one coat of red oxide with erection on site as per
direction of engineer in charge with necessary grouting, cementing, plastering & finishing
Total cost (in Rs.) =
Percolating Well
Description Unit Qty Rate Amount
Security & Panel Room:
(I) Providing & Installing , commissioning & Testing of One number of Horizontal Filtration Module is
Precast Modular Step well og M 25 grade, designed to capture sediments primarily from surface runoff
water. This Octagonal shape structure has a circumscribing diameter of approximately 1500mm and a
height of 3475mm. A part of the top module is usually kept above the ground however same can be
flushed with ground. 300/400/610mm are the available height options in case part of it has to be kept
above the ground level. Top module accommodates indigenously designed 4-Nos Array Filters to capture
sediment effectively within the Horizontal Filtration Module. This easily removable array filters can be
cleaned within or outside the module using pressurized water. Total filtation area of this filter is
approximately 6000 cm2. Filtration capacity is 20m3 to 30m3 per hour. These module is installed prior to
the Sand Filtration Module. The inlet and outlet of is 160mm diameter UPVC Pipes.(II) Providing &
Installing, ral ladder at 1125 mm with water cleaning system, labours, hand bucket, lari & other tools. ie.e
Trikam , Pavda, rassa, Battery, G.T. silica etc. with disposing silt as appropriate places as directed by
engineer in charge. No any additional payment shall be made for cleaning and maintenance work. All
required testing shall be carried out by bidder without any extra cost for preparing design and drawing
for above work and approval of design from competent authority of GUDC is in the scope of bidder. No
any extra payment shall be made for the same. Precase slabs held together between two horizontal
precasr slabs ( with 590,, edge length , 50mm thick and hole of 100mm diameter in the centre) Bottom
module holds another type of filter media in the form of sand bed around a continuous slot fine aperture
stainless screen ( 420 mm diameter and 300 or 450 mm length). Screen is fixed to the bottom slab and is
fully covered by filtration sand. Screen creates entry points of the filtration water. Module filtration
capacity & testing upto 20m3 to 30m3 per hour from modular systems only.
This module is used for Roof water harvesting and it is connected with the Exisiting tubewell / recharge
well / UG Storage tank.( III ) Providing and Fixing 200mm M.S. Casing Pipe ( 114 mtr. 5mm Thick) approved
make like (Tata, Jindal, Surya Or as approved by engineer incharge) with to be connected 200mm LCG V-
wire Screen (36 Mtr) with 450 mm Dia Drilling, water, mudslurry tankers, loading unloading, providing
Gravel, Clay/Sand, gravel packing, Clay/Sand Packing and Cleaning with compressor 750/200 PSI) total
depth of recharge well should be 152 mtr inclusive of mud pit and mud refilling, site cleaning etc. (IV) The
above work is including as per approved drawing and required to completed the work, (i) Excavation for
foundation with refilling upto required depth including sorting out and stacking of useful materials and
disposing off the excavated stuff with all lead and lift in any kind of soil, (ii) Providing and Laying on
concrete 1:2:4 (1 Cement : 2- course sand : 4 graded stone aggregate 20mm nominal size ) and curring
complete including cost of form work and rainforcement etc complete ( iii) Brick work using common
burnt clay building bricks having crushing strength not less than 35 kg/Sq.Cm in foundation and plinth in
Cement Mortar 1:6 (1- Cement : 6- Finesand) (B) Conventional with 15mm. thick in Cement Plaster 1:3 ( 1-
Cement : 3- Finesnad) n single coat on rough (similar) side of single or half brick walls. (iv) Providing and
fixing 150MM Dia (S.S.304) 600MM Length Leaf Trap (6mm Slot) (v) Job work for cleaning of modules for
every pre monsoon for total 5 year (once in a Year) with in built intergral ladder at 1125mm with water
cleaning sysyem, labours , hand bucket, lari* other tools.ie.Trikam, Pavda, Rassa, Battery , G.T. Salia etc.
with disposing slit as appropriate places as directed by Engineer in Charge. No Any Additonal Payment
shall be made for cleaning and maintenance work. All reuqired testing shall be carried out by bidder
without any extra cost for preparing design and drawing for above wprk and approval of the design from
compentent authority of GUDC is in the scope of bidder. No any extra payment shall be made for the
Total cost (in Rs.) =
Development of Garden and Plantation
Description Unit Quantity Rate Amount
Supplying and stacking of well decayed cattle manure at site including
royalty and carriage upto 5 k.m.lead complete.
2 Rough dressing the trenched ground including breaking clods. Sqmt 14840.00 1.50
3 Fine dressing of the ground. Sqmt 14840.00 3.70
Spreading and Mixing earth and sludge or manure and/or good earth in
4 required thickness as per direction of officer-in-charge (cost of sludge, Cumt 5194.00 52.35
dump manure and/ or good earth to be paid separately).
Grassing with selection No. 1 Doob grass including watering and
maintenance of the lawn for 30 days or more till the grass forms a thick
lawn, free from weeds and fit for mowing including supplying good earth,
if needed (the grass and good earth shall be paid for separately).
Supplying & Stacking of Selection No.1 doob grass turf at site fresh & free
6 from weeds having proper roots in green including loading, unloading, Sqmt 14300.00 50.80
carriage and all taxes paid etc.and as per direction of officer in charge.
Preparation of beds for hedging and shrubbery by excavating 60 cm deep
and trenching the excavated base to a further depth of 30 cm, refilling the
excavated earth after breaking clods and mixing with sludge or manure in
the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%:
one part of stacked volume of sludge or manure after reduction by 8%),
flooding with water, filling with earth if necessary, watering and finally fine
dressing, leveling etc. including stacking and disposal of materials declared
unserviceable and surplus earth by spreading and leveling as directed,
within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or
extra earth to be paid for separately)
Digging holes in ordinary soil and refilling the same with the excavated
earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of
stacked volume of earth after reduction by 20% : 1 part of stacked volume
8 of manure after reduction by 8%) flooding with water, dressing including Each 1376.67 18.70
removal of rubbish and surplus earth, if any, with all leads and lifts (cost of
manure, sludge or extra good earth if needed to be paid for separately)
Holes 45 cm dia, and 45 cm deep
Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of
9 unserveiceable material’s as per direction of officer in charge (excluding Each 960.00 7.30
cast of plant & water)
Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm
10 in big polybag of size 25 cm as per direction of the officer-in-charge. Each 60.00 65.00
Providing and stacking of Ficus bengalensis (Bargad) of height 120-135 cm.
11 in big poly bags of size 25 cm as per direction of the officer-in-charge. Each 60.00 65.00
(Wad Banyan, Ficus benghalensis )
Description Unit Quantity Rate Amount
Providing and stacking of Plumeria alba dwarf dwarf of height 90-105 cm.
12 with 3-4 branches and thick stem in big size HDPE bags as per direction Each 60.00 750.00
of the officer-in-charge. (West Indian Jasmine)
Providing and stacking of Pterospermum acerifolium (Kanak Champa) of
13 height 150-165 cm. in big poly bags of size 25 cm as per direction of the Each 60.00 65.00
officer-in-charge.
Providing and stacking of Ficus religiosa (Peepal) of height 150-165 cm. in
14 big poly bags of size 30 cm as per direction of the officer-in-charge. Each 50.00 65.00
Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in
15 big poly bags of size 25 cm as per direction of the officer-in-charge. Each 50.00 65.00
(Amaltash , Garmado)
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm.
in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Foxtail palm of ht. 240-270 cm bottom girth 35-
17 40 cm well developed in big size HDPE bags as per direction of the officer- Each 27.00 650.00
Providing and stacking of Calliandra hybrida of height 105-120 cm., well
18 branched, bushy inbig size HDPE bag as per direction of the officer-in- Each 150.00 90.00
Providing and stacking of Caesalpinia pulcherrima species of height 45-60\
cm. in earthen pot of size 20 cm as per direction of the officer-in-charge.
Providing and stacking of Bauhinia tomentosa (yellow) of height 60-75 cm.
in earthen pots of size 20 cm as per direction of the officer-in-charge
Providing and stacking of Euphorbia caracasana (bronze colour leaves) of
21 height 60-75 cm. with 4-5 branches in bag of size 25 cm as per direction of Each 150.00 55.00
the officer-in-charge.
Providing and stacking of Hamelia patens of height 30-45 cm. with 3-4
22 branches in poly bags of size 20 cm as per direction of the officer-in- Each 120.00 20.00
Providing and stacking of Hibiscus rosasinensis of height 90-105 cm., bushy
in big size HDPE bag as per direction of the officer-in-charge
Providing and stacking of Tabernaemontana coronaria (Chandni single) of
24 height 90-105 cm.,bushy in big size HDPE bag as per direction of the officer- Each 120.00 80.00
Total cost (in Rs.) =
Veterinary Hospital
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5 m depth including sorting out and
1 stacking of useful materials and disposing off the excavated stuff upto 50 cum 91.00 122.99
Meter lead. (A) Loose or soft soil.
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting
2 out and stacking of useful materials and disposing off the excavated stuff cum 24.00 136.33
upto 50 Meter lead. (A) Loose or soft soil.
Filling available excavated earth (excluding rock) in trenches. plinth, sides
3 of foundations etc. in layers not exceeding 20 cm. in depth consolidating cum 59.40 136.92
each disposited layer by ramming and watering.
Providing and laying cement concrete (M-10) 1:3:6 (1-Cement : 3- coarse
4 sand : 6- hand broken stone aggregates 40 mmnominal size) and curing cum 33.00 2,968.91
complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying controlled cement concrete M.250 with and curing
complete including the cost of formwork and reinforcement for reinforced
concrete work in (A) Foundations, footings, Base of columns and Mass
Providing and laying controlled cement concrete M.250 with and curing
6 complete including the cost of formwork and reinforcement for reinforced cum 14.00 7,729.49
concrete work in (D) Columns, Pillars posts and struts, upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
7 complete including the cost of formwork and reinforcement for reinforced cum 35.00 6,176.56
concrete work in (C) Beams, Girders upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
8 complete including the cost of formwork and reinforcement for reinforced cum 43.00 6,237.40
concrete work in (C) Slabs. upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
9 complete including the cost of formwork and reinforcement for reinforced cum 3.00 7,223.22
concrete work in (C) Lintels. upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
10 complete including the cost of formwork and reinforcement for reinforced cum 2.00 6,202.27
concrete work in (C) Cantilever Chajja upto floor two level.
Providing and laying controlled cement concrete M-250 for RCC works
including the cost machine mixing, vibrating, scaffolding, incl. cost of form
work / shuttering but excluding cost of reinforcement etc. complete up to
floor 2 level for Stair- Steps and Sofit Slab
Providing and laying controlled cement concrete M-250 for RCC works
including the cost machine mixing, vibrating, scaffolding, incl. cost of form
work / shuttering but excluding cost of reinforcement etc. complete up to
floor 2 level for copping
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
Description Unit Quantity Rate Amount
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
Brick work using common burnt clay building bricks having crushing
strength not less than 35kg / Sq. C. M. in ramp, steps and Foundation &
Plinth in cement morter1:5 (1 cement : 5 coarse sand) including racking
out joints, curing, scaffolding required if any etc.complete, as directed.
Brick masonry in cement mortar (1:5) using common burnt clay building
16 bricks having crushing strength not less than 35kg/csmt including cum 69.00 3,489.80
scaffolding,curing, etc. complete for walls, parapets, etc. at all levels.
Providing Half brick masonry in common burnt clay building bricks having
crushing strength not less than 35 Kg/csmt in C. M. 1:4 for partition work
including raking out joints, curing, scaffolding etc. complete as directed for
Providing and applying 15 mm thick cement plaster in single coat on brick
work with floating coat of net cement slurry for interior plastering of
pumphouse and outside plastering upto finished even and smooth in
Cement motar 1 : 3 (1 cement : 3 sand) including racking out joint curing,
scaffolding required if any, with necessary cement finishing etc. complete
20 mm thick sand faced cement plaster on walls upto height 10 metres
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8 mm thick finishing coat of C.M. 1:1 (1-cement :
sand) etc. complete.
Finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly
brushing the surface to removal dirt, and remains of loose powdered
materials.etc complete
Distempering (two coats) with oil bound distemper of approved brand and
manufacture and or required shade on undecorated wall surface to give an
even shade, over and including a priming coat with distemper primer of
approved brand and manufacturer after thoroughly brushing the surface
free from mortar dropping and other foreign matter also including
preparing the surface even and sand papered smooth.
Applying two coats of Birla (white cement based) or Asian (acryliclapy
putty) or equivalent & two coats of primer of approved brand and
22 manufacture on new wall surface to give an even shade including Sqmt 497.00 40.59
thoroughly brushing the surface free from mortar dropping and other
foreign matte rand sand papered smooth.
Providing 100 mm x 100 mm size vata in cement mortar (1:1) including
smooth finish, curing, etc. complete.
Providing and laying 50 mm thick heavy duty cement concrete flooring
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) with ironite powder including finishing with a floating of neat cement
Description Unit Quantity Rate Amount
Providing and laying Vitrified tiles 8 to 10 mm thick , 36'' x 36'' in flooring
25 treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 Sqmt 170.00 1,531.82
(1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of
26 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse Sqmt 7.00 1,592.40
sand) and jointed with white cement slurry
Providing and laying polished Kota stone slab flooring over 20 mm
(average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid
over and jointed with grey cement slurry including rubbing and polishing
etc. complete at Kitchen room & Store room. 30 mm thick
Providing and laying polished Kota stone slab 25 mm thick in riser of steps,
skirting Dedo & pillars laid on 10 mm thick cement mortar 1:3 (1 cement :
3 coarse sand) and jointed with grey cement slurry including rubbing and
polishing etc. complete
Constructing a cooking platform 60 cm. width and 70 cm high resting on
B.B.Masonry walls 23 cm.thick in C.M.(1:6) with (ii) Fixing black kadappa
stone 30mm thick laid on precast R.C.C. (1:2:4) slab with plastering on
exposed faces of wall in C.M. (1:4) etc complete.
Providing and fixing 35mm thick factory made moulded door shuter
consisting of solid core single leaff lush door of 30mm thickness, lipped
with 15mm (5mmx3) thick x30mm width on one stiles and top rail and
10mm (5mmx2) thickx 30mm width on the other stiles and bottom
rails.The inner panell aminated with 2mm thick termite proof, water proof
30 and fire resistant moulded PVC sheet with 2,4,6 raised panel design in smt 27.00 2,152.31
different plain and/or prelim colour so none side after routing the
moulded design on flush door and 2mm plain and/or prelim PVC sheet on
other side using rubber adhesive on flush door and solvent cement
adhesive on the PVC liping etc.complete as per direction of Engineer
incharge, manufacture’s specification and drawing.
Providing and fixing glazed louvered glass windows and ventilators
with teak wood frame 10cm. x 7cm. size including 3 coats of oil painting
to wood work etc.complete. with wooden louvers plank 12mm thick (upto
Providing and fixing M.S. grills of required pattern to wooden frames of
windows etc. with M.S. flats at required spacings and frame alround,
square or round bars with round headed bolts and nuts or by screws (A)
Providing precast cement concrete jali or louvers 40 mm thick 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size)
reinforced with 1.6 mm dia. Mild steel wire including roughening,
cleaning, fixing and finishing in CM 1:3 and curing, painting complete
34 Providing and fixing 160 PVC SWR pipes IS 13592 for Drain - 160 mmdia Rmt 98.00 515.27
Painting two coats including priming coat on new steel & other metal
35 surfaces with enamel paint, brushing, interior to give an even shade Sq.M. 100.00 92.17
including cleaning the surface of all dirt, dust, other foreign matter.
Description Unit Quantity Rate Amount
Providing throating or plaster drip and moulding to R.C.C. Chhajja as
instructed by Engineer in charge.
Providing and laying broken China Mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to be laid over Cement mortar 1:3
to plain or slope and to be tempered to bring mortar crème out upto
surfAEC using white cement including rounding of junctions and extending
them upto 15 cm. along the wall, clearing with water and oxalic acid etc. as
Extra for providing and mixing water proofing material in Cement concrete
38 per Quintal 90.00 49.16
in mix proportion recommended by the manufacturers.
Providing and laying coloured glazed tiles of the size 300 mm x 200 mm x
mm / 300 mm x 450 mm x 8 mm in skirting, risers of steps and dedo on
mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with
white cement slurry.
Providing and fixing wash down watercloset (Europeantype,W.C.Pan) with
integral Por S trap including jointing the trap with soil pipei n Cement
Mortar1:1(1-Cement:1-fine sand) (Seal and cover to beme asured and paid
40 for separately) (A)vitreous China Pattern :(i) in white colour No 1.00 2,274.09
32 dia. C. P. brass half turn flush cock complete including earthwork, bed
concrete of 1:4:8. , & Jet spray heavy duty with S.S. Braided hose 60 cm
Providing and fixing flat back white colour vitreous china wash basin
mm x 400 mm size with CI brackets painted white. Wash basin shall have
15 mm dia GI supply pipe, overflow chase, 15 mm dia pillar cock and stop
cock with chromium plated bottle trap, Rubber ring and PVC pipe piece
41 upto wall plus 32 mm dia PVC waste pipe upto floor level connected to 32 No. 2.00 2,506.67
mm dia CI pipe below floor and connected to nearby floor trap complete
with unions and plumber's white soldered joints with necessary cleaning
eye, complete. All chases cut in wall for fixing pipes shall be made good in
Providing and fixing Flat Back Urinal ( Hindware- 44cmx31.5cmx26.5cm)
or equivalent approved and of approved shade including fixing the same
42 in concealed CI brackets, CP spreader, CP dome shaped waste coupling, CP No. 1.00 1,619.12
bottle trap with flanges, CP angle cock flush pipe making inlet and out let
connections all complete as per the instruction of Engineer - In - Charge
Providing and fixing 600 mm. X 450 mm. Bevelled edge mirror of superior
43 glass mounted on 6 mm. Thick A.C, sheet or plywood sheet and fixed to No. 2.00 859.41
wooden plugs with C.P. brass screws and washers
Description Unit Quantity Rate Amount
Providing, laying and jointing in true line and level U.P.V.C. Pipe (SCH-40)
for including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall be fixed on the
44 wall with the help of clamp at every two metre C/C or shall be concelled as Rmt. 10.00 72.65
directed including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C
(Type B) conforming to IS 13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe shall be fixed on wall using of PVC
clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at
every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of
Providing & fixing gun metal check or non return full way wheel valve
52 Providing and fixing brass screw down stop tap. (A) 15mm dia. No 7.00 205.83
Providing and fixing screw down bib taps of following size.(C)Gun metal
screw down bib tap. i) 15mm dia.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement: 2-
coarses and :4- graded stone aggregate 20 mm nominal size) foundation
concrete 1:3:6 mix (1-cement : 3-coarse sand : 6-Brick bats 40+50 mm size)
inside plastering 15 mm thick with Cement Mortar 1:5 (1-Cement : 5-
coarse sand)finished with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-Cement: 2-Coarses and : 4-stone
54 aggregate 20 mm nominal size) finished smooth complete including curing No 2.00 11,042.74
and festing (i) Inside size 900mm x 1200 mm and 2.0 M. deep including C.I.
cover with frame size 560mm diameter total weight of cover and frame to
be not less than 128kgs. (Wt. of cover 64Kg. and Wt. of frame 64Kg.) (A)
With 230 mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg./Sq.cm. in Cement Mortar 1:5 (1- Cement : 5-
Coarse sand) (1) A type depth 0.90 Metre for 150 mm diameter sewer.
Description Unit Quantity Rate Amount
Providing and supplying in standered length ISI mark rigid unplasticised
PVC pipes suitable for potable water with ringfit joint including cost of
rings, as per IS specification no. 4985/1988 including all local and central
55 taxes, transportation, freight charges,octroi,inspection charges, loading, Rmt 15.00 326.20
unloading conveyance to the departmental stores and including cost of
jointing material etc. complete Test pressure of 4 Kg./csmt of 160 mm dia
Providing and fixing cast iron (Spun) Nahni trap of the following nominal
diameter of self cleaning design with C.I. screaed down or hinged grating
including cost of cutting and making good the walls and floor 100mm inlet
and 50mm outlet. (C) 100mm dia.
Providing and fixing S.W. gully trap with C.I. grating brick masonry
chamber and water tight C. I. cover with frame of 300 mm x 300 mm size
(inside) with standard weight. (i) Square mouth traps.(B) 150mm x 100mm
size P or R type
Providing and fixing100mm size P or Strap for water closet squatting pan
58 including jointing the trap with the pan and soil pipe in cement Mortar1:1 No 4.00 332.52
(1-Cement : 1-Fine sand) (A) Vitreous China.
Providing and laying (to level or slopes) and jointing with stiff mixture of
59 Cement Mortar in proportion 1:1 Selt glazed stone ware pipes including Rmt. 40.00 317.28
testing of pipes and joints complete.(B)150mm dia.
Constructing brick masonry chamber for under ground C.I. Inspection
chamber and bends with bricks having crushing strength not less than
35Kg.Cm 2in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm
internal dimensions total weight of cover with frame to be not less than
38Kg. (Wt. of cover 23Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab e with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar
1:3 finished smooth with a floating coat of neat cement on walls and bed
concrete etc. complete. (ii) Inside dimensions 500mmx700mm and 450mm
deep for pipe line with one or two inlets. (upto 10 ton)
Providing erecting and fixing double coated ISI water tank of required
61 capacity of approved manufacture with all necessary fittings and liter 2000.00 3.95
connection etc. complete on terrace.
Description Unit Quantity Rate Amount
Providing and constructing Sewer manholes, scraper manholes and unit
house connection chamber, as per the type design in brick masonry in C.M.
1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary
100 mm coping with reinforcement in R.C.C.M. 200 fixing C. I. steps and
fixing manhole frame and covers (But excluding supply of manhole frame
and covers) over manholes and house connection chambers and fixing
Manhole covers (but excluding supplying of manhole covers) over scraper
manhole etc. complete, providing and fixing safety chain wherever
necessary as per the stipulations in the type design complete as per latest
CPHEEO manual.(excl. excavation). Manhole type "A" Circular type having
inside diameter of 1200 mm for depth upto 1.5 m depth (for 150 mm to
500 mm dia sewer) Manhole type "A" as above but upto 1.0 M depth.
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store
or at site of work precast RCC M.200 Frame & cover suitable to drainage
63 M.H. and as per type design & Drawing including cost of reinforcement Nos 1.00 1,289.15
M.S. Angles or Flat, curing mold work etc. Frame suitable for 50cm
opening of MH (A) For Circular manhole (heavy duty)
Cover suitable for 50 cm opening of MH (A) For Circular manhole (heavy
Providing and supplying ISI marked only Standard length Stoneware pipes
in standard lengths of following class and diameter including all taxes,
65 insurance, transportation, freight charges, octroi, inspection charges, Rmt 20.00 180.79
loading, unloading, conveyance to departmental stores, stacking etc.
complete. (IS - 651 / 1989) Class AA 150 mm Dia
Lowering, laying and jointing Stone Ware pipes of following diameters with
cement joints in C. M. 1:1 proportion in proper position, grade and
66 alignment at all level as directed by Engineer-in-charge including Rmt 20.00 101.20
conveyance from stores to site of work, Jointing material etc. comp.150
Dewatering by pumping set of required capacity including temporary
67 platform carting pumping at site and fixing the same in position including HP/hr 200.00 21.07
all accessories, and fuel and labour etc. complete.
68 Providing and fixing in position cowel went to pipes. (B) 75mm dia. No 2.00 393.04
Door closers (Heavy type of 765 number) Hardwire or EveritePrabhat or
71 C.P. Brass toilet paper holder of stand and size No 6.00 220.83
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets
fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
74 C.P. Brass 1/2 turn flush cock 32 mm dia No 6.00 236.24
75 Abonite ball cock 25mm dia No 6.00 88.16
Description Unit Quantity Rate Amount
Applying priming coat of over new steel and other metal surface after and
including preparing the surface by thoroughly cleaning, oil grease, dirt and
other foreign mater and scoured with brushes fine steel wool, scrapers and
sand paper with ready mixed priming paint brushing red lead.
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brusing interior to give an even shade including
cleaning the surface an even shade including cleaning the surface of all
dirt, dust and other foreign matter.
For Gate :- Steel work, welded in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat of red lead
78 paint. (A)In beams and joists, channels angles Tees, flats, with connecting kg 1200.00 91.08
plates or angle cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
5000 Litre Capacity UG Ractangular Tank
"Preparing structural design of RCC Under Ground / Partially under ground
/ above high ground level Reservoir of required capacity as per relevant I.S.
standards and constructing the same, including excavation in all types of
soil strata (including rock) including shoring strutting if required, for loose
soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course
in M-15, Refilling the pit with proper soil and disposing of the surplus stuff
at all lead. Including cement plaster in CM 1:2 withapproved water
proofing compound to all over inside container (i.e. walls, base, top
79 slab/dome bottom etc. all). including all typesof labour and material Litre 5000.00 6.50
charges of lowering, laying, erecting / hosting and jointing of pipe
assembly to inlet, outlet overflow, washout and bye pass arrangement as
per hydraulic design. Providing and fixing accessories, CI Manhole frame
and cover, water level indicator, adequate cowl type ventilators or lantern
type ventilator with stainless steel jail. RCC chambers for valves.
Providing and applying three coats of cement paint / snowcem to the out
side face of structure. It also includes satisfactory water tightness test as
per relevant I.S. code and painting name of scheme and capacity on the
tank as per direction of engineer in charge."
Total cost (in Rs.) =
Office Building
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5 m depth including sorting out and
1 stacking of useful materials and disposing off the excavated stuff upto 50 cum 75.00 122.99
Meter lead. (A) Loose or soft soil.
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting
2 out and stacking of useful materials and disposing off the excavated stuff cum 20.00 136.33
upto 50 Meter lead. (A) Loose or soft soil.
Filling available excavated earth (excluding rock) in trenches. plinth, sides
3 of foundations etc. in layers not exceeding 20 cm. in depth consolidating cum 55.67 136.92
each disposited layer by ramming and watering.
Providing and laying cement concrete (M-10) 1:3:6 (1-Cement : 3- coarse
4 sand : 6- hand broken stone aggregates 40 mmnominal size) and curing cum 20.00 2,968.91
complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying controlled cement concrete M.250 with and curing
complete including the cost of formwork and reinforcement for reinforced
concrete work in (A) Foundations, footings, Base of columns and Mass
Providing and laying controlled cement concrete M.250 with and curing
6 complete including the cost of formwork and reinforcement for reinforced cum 25.00 7,729.49
concrete work in (D) Columns, Pillars posts and struts, upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
7 complete including the cost of formwork and reinforcement for reinforced cum 31.00 6,176.56
concrete work in (C) Beams, Girders upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
8 complete including the cost of formwork and reinforcement for reinforced cum 44.00 6,237.40
concrete work in (C) Slabs. upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
9 complete including the cost of formwork and reinforcement for reinforced cum 2.00 7,223.22
concrete work in (C) Lintels. upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
10 complete including the cost of formwork and reinforcement for reinforced cum 3.00 6,202.27
concrete work in (C) Cantilever Chajja upto floor two level.
Providing and laying controlled cement concrete M-250 for RCC works
including the cost machine mixing, vibrating, scaffolding, incl. cost of form
work / shuttering but excluding cost of reinforcement etc. complete up to
floor 2 level for Stair- Steps and Sofit Slab
Providing and laying controlled cement concrete M-250 for RCC works
including the cost machine mixing, vibrating, scaffolding, incl. cost of form
work / shuttering but excluding cost of reinforcement etc. complete up to
floor 2 level for copping
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
Description Unit Quantity Rate Amount
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
Brick work using common burnt clay building bricks having crushing
strength not less than 35kg / Sq. C. M. in ramp, steps and Foundation &
Plinth in cement morter1:5 (1 cement : 5 coarse sand) including racking out
joints, curing, scaffolding required if any etc.complete, as directed.
Brick masonry in cement mortar (1:5) using common burnt clay building
16 bricks having crushing strength not less than 35kg/csmt including cum 93.00 3,489.80
scaffolding,curing, etc. complete for walls, parapets, etc. at all levels.
Providing Half brick masonry in common burnt clay building bricks having
crushing strength not less than 35 Kg/csmt in C. M. 1:4 for partition work
including raking out joints, curing, scaffolding etc. complete as directed for
Providing and applying 15 mm thick cement plaster in single coat on brick
work with floating coat of net cement slurry for interior plastering of
pumphouse and outside plastering upto finished even and smooth in
Cement motar 1 : 3 (1 cement : 3 sand) including racking out joint curing,
scaffolding required if any, with necessary cement finishing etc. complete
20 mm thick sand faced cement plaster on walls upto height 10 metres
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8 mm thick finishing coat of C.M. 1:1 (1-cement :
sand) etc. complete.
Finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly
brushing the surface to removal dirt, and remains of loose powdered
materials etc. complete
Distempering (two coats) with oil bound distemper of approved brand and
manufacture and or required shade on undecorated wall surface to give an
even shade, over and including a priming coat with distemper primer of
approved brand and manufacturer after thoroughly brushing the surface
free from mortar dropping and other foreign matter also including
preparing the surface even and sand papered smooth.
Applying two coats of Birla(white cement based) or Asian (acryliclapy
putty) or equivalent & two coats of primer of approved brand and
22 manufacture on new wall surface to give an even shade including Sqmt 691.00 40.59
thoroughly brushing the surface free from mortar dropping and other
foreign matte rand sand papered smooth.
Providing 100 mm x 100 mm size vata in cement mortar (1:1) including
smooth finish, curing, etc. complete.
Providing and laying 50 mm thick heavy duty cement concrete flooring
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) with ironite powder including finishing with a floating of neat cement
Description Unit Quantity Rate Amount
Providing and laying Vitrified tiles 8 to 10 mm thick, 36'' x 36'' in flooring
25 treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 Sqmt 191.00 1,531.82
(1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of
26 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse Sqmt 6.00 1,592.40
sand) and jointed with white cement slurry
Providing and laying polished Kota stone slab flooring over 20 mm
(average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid
over and jointed with grey cement slurry including rubbing and polishing
etc. complete at Kitchen room & Store room. 30 mm thick
Providing and laying polished Kota stone slab 25 mm thick in riser of steps,
skirting Dedo & pillars laid on 10 mm thick cement mortar 1:3 (1 cement :
coarse sand) and jointed with grey cement slurry including rubbing and
polishing etc. complete
Constructing a cooking platform 60 cm. width and 70 cm high resting on
B.B.Masonry walls 23 cm.thick in C.M.(1:6) with (ii) Fixing black kadappa
stone 30mm thick laid on precast R.C.C. (1:2:4) slab with plastering on
exposed faces of wall in C.M. (1:4) etc complete.
Providing and fixing 35mm thick factory made moulded door shuter
consisting of solid core single leaff lush door of 30mm thickness, lipped
with 15mm (5mmx3) thick x30mm width on one stiles and top rail and
10mm (5mmx2) thickx 30mm width on the other stiles and bottom
rails.The inner panell aminated with 2mm thick termite proof, water proof
30 and fire resistant moulded PVC sheet with 2,4,6 raised panel design in smt 27.00 2,152.31
different plain and/or prelim colour so none side after routing the
moulded design on flush door and 2mm plain and/or prelim PVC sheet on
other side using rubber adhesive on flush door and solvent cement
adhesive on the PVC liping etc.complete as per direction of Engineer
incharge, manufacture’s specification and drawing.
Providing and fixing glazed louvered glass windows and ventilators
31 with teak wood frame 10cm. x 7cm. size including 3 coats of oil painting smt 1.00 4,434.35
to wood work etc.complete. with wooden louvers plank 12mm thick.
Providing and fixing M.S. grills of required pattern to wooden frames of
windows etc. with M.S. flats at required spacings and frame alround,
square or round bars with round headed bolts and nuts or by screws (A)
Providing precast cement concrete jali or louvers 40 mm thick 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size)
reinforced with 1.6 mm dia. Mild steel wire including roughening,
cleaning, fixing and finishing in CM 1:3 and curing, painting complete
34 Providing and fixing 160 PVC SWR pipes IS 13592 for Drain - 160 mm dia Rmt 98.00 515.27
Painting two coats including priming coat on new steel & other metal
35 surfaces with enamel paint, brushing, interior to give an even shade Sq.M. 100.00 92.17
including cleaning the surface of all dirt, dust, other foreign matter.
Description Unit Quantity Rate Amount
Providing throating or plaster drip and moulding to R.C.C. Chhajja as
instructed by Engineer in charge.
Providing and laying broken China Mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to be laid over Cement mortar 1:3
to plain or slope and to be tempered to bring mortar crème out upto
surfAEC using white cement including rounding of junctions and extending
them upto 15 cm. along the wall, clearing with water and oxalic acid etc. as
Extra for providing and mixing water proofing material in Cement concrete
38 per Quintal 90.00 49.16
in mix proportion recommended by the manufacturers.
Providing and laying coloured glazed tiles of the size 300 mm x 200 mm x
mm / 300 mm x 450 mm x 8 mm in skirting, risers of steps and dedo on
mm. thick cement plaster 1:3 (1 cement : 3 coarse sand) & jointed with
white cement slurry.
Providing and fixing wash down watercloset (Europeantype,W.C.Pan) with
integral Por S trap including jointing the trap with soil pipei n Cement
Mortar1:1(1-Cement:1-fine sand) (Seal and cover to beme asured and paid
for separately) (A)vitreous China Pattern :(i) in white colour 32 dia. C. P.
brass half turn flush cock complete including earthwork, bed concrete of
1:4:8. , & Jet spray heavy duty with S.S. Braided hose 60 cm long
Providing and fixing flat back white colour vitreous china wash basin
mm x 400 mm size with CI brackets painted white. Wash basin shall have
15 mm dia GI supply pipe, overflow chase, 15 mm dia pillar cock and stop
cock with chromium plated bottle trap, Rubber ring and PVC pipe piece
41 upto wall plus 32 mm dia PVC waste pipe upto floor level connected to 32 No. 2.00 2,506.67
mm dia CI pipe below floor and connected to nearby floor trap complete
with unions and plumber's white soldered joints with necessary cleaning
eye, complete. All chases cut in wall for fixing pipes shall be made good in
Providing and fixing Flat Back Urinal (Hindware- 44 cm x 31.5 cm x
cm) or equivalent approved and of approved shade including fixing the
same in concealed CI brackets, CP spreader, CP dome shaped waste
coupling, CP bottle trap with flanges, CP angle cock flush pipe making inlet
and out let connections all complete as per the instruction of Engineer - In -
Providing and fixing 600 mm. X 450 mm. Bevelled edge mirror of superior
43 glass mounted on 6 mm. Thick A.C, sheet or plywood sheet and fixed to No. 2.00 859.41
wooden plugs with C.P. brass screws and washers
Description Unit Quantity Rate Amount
Providing, laying and jointing in true line and level U.P.V.C. Pipe (SCH-40)
for including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall be fixed on the
44 wall with the help of clamp at every two metre C/C or shall be concelled as Rmt. 10.00 72.65
directed including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all materials.
Providing, laying and jointing in true line and level 110 diametre U.P.V.C
(Type B) conforming to IS 13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe shall be fixed on wall using of PVC
clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at
every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of
Providing & fixing gun metal check or non return full way wheel valve
52 Providing and fixing brass screw down stop tap. (A) 15mm dia. No 7.00 205.83
Providing and fixing screw down bib taps of following size.(C)Gun metal
screw down bib tap. i) 15mm dia.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement: 2-
coarses and :4- graded stone aggregate 20 mm nominal size) foundation
concrete 1:3:6 mix (1-cement : 3-coarse sand : 6-Brick bats 40+50 mm size)
inside plastering 15 mm thick with Cement Mortar 1:5 (1-Cement : 5-
coarse sand)finished with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-Cement: 2-Coarses and : 4-stone
54 aggregate 20 mm nominal size) finished smooth complete including curing No 2.00 11,042.74
and festing (i) Inside size 900mm x 1200 mm and 2.0 M. deep including C.I.
cover with frame size 560mm diameter total weight of cover and frame to
be not less than 128kgs. (Wt. of cover 64Kg. and Wt. of frame 64Kg.) (A)
With 230 mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg./Sq.cm. in Cement Mortar 1:5 (1- Cement : 5-
Coarse sand) (1) A type depth 0.90 Metre for 150 mm diameter sewer.
Providing and supplying in standered length ISI mark rigid unplasticised
PVC pipes suitable for potable water with ringfit joint including cost of
rings, as per IS specification no. 4985/1988 including all local and central
55 taxes, transportation, freight charges,octroi,inspection charges, loading, Rmt 15.00 326.20
unloading conveyance to the departmental stores and including cost of
jointing material etc. complete Test pressure of 4 Kg./csmt of 160 mm dia
Description Unit Quantity Rate Amount
Providing and fixing cast iron (Spun) Nahni trap of the following nominal
diameter of self cleaning design with C.I. screaed down or hinged grating
including cost of cutting and making good the walls and floor 100mm inlet
and 50mm outlet. (C) 100mm dia.
Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber
and water tight C. I. cover with frame of 300 mm x 300 mm size (inside)
with standard weight. (i) Square mouth traps.(B) 150mm x 100mm size P or
Providing and fixing100mm size P or Strap for water closet squatting pan
58 including jointing the trap with the pan and soil pipe in cement Mortar1:1 No 4.00 332.52
(1-Cement : 1-Fine sand) (A) Vitreous China.
Providing and laying (to level or slopes) and jointing with stiff mixture of
59 Cement Mortar in proportion 1:1 Selt glazed stone ware pipes including Rmt. 40.00 317.28
testing of pipes and joints complete.(B)150mm dia.
Constructing brick masonry chamber for under ground C.I. Inspection
chamber and bends with bricks having crushing strength not less than
35Kg.Cm 2in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm
internal dimensions total weight of cover with frame to be not less than
38Kg. (Wt. of cover 23Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab e with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar
1:3 finished smooth with a floating coat of neat cement on walls and bed
concrete etc. complete. (ii) Inside dimensions 500mmx700mm and 450mm
deep for pipe line with one or two inlets. (upto 10 ton)
Providing erecting and fixing double coated ISI water tank of required
61 capacity of approved manufacture with all necessary fittings and liter 25000.00 3.95
connection etc. complete on terrace.
Providing and constructing Sewer manholes, scraper manholes and unit
house connection chamber, as per the type design in brick masonry in C.M.
1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary
100 mm coping with reinforcement in R.C.C.M. 200 fixing C. I. steps and
fixing manhole frame and covers (But excluding supply of manhole frame
and covers) over manholes and house connection chambers and fixing
Manhole covers (but excluding supplying of manhole covers) over scraper
manhole etc. complete, providing and fixing safety chain wherever
necessary as per the stipulations in the type design complete as per latest
CPHEEO manual.(excl. excavation). Manhole type "A" Circular type having
inside diameter of 1200 mm for depth upto 1.5 m depth (for 150 mm to
500 mm dia sewer) Manhole type "A" as above but upto 1.0 M depth.
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store
or at site of work precast RCC M.200 Frame & cover suitable to drainage
63 M.H. and as per type design & Drawing including cost of reinforcement Nos 1.00 1,289.15
M.S. Angles or Flat, curing mold work etc. Frame suitable for 50cm opening
of MH (A) For Circular manhole (heavy duty)
Description Unit Quantity Rate Amount
Cover suitable for 50cm opening of MH (A) For Circular manhole (heavy
Providing and supplying ISI marked only Standard length Stoneware pipes
in standard lengths of following class and diameter including all taxes,
65 insurance, transportation, freight charges, octroi, inspection charges, Rmt 20.00 180.79
loading, unloading, conveyance to departmental stores, stacking etc.
complete. (IS - 651 / 1989) Class AA 150 mm Dia
Lowering, laying and jointing Stone Ware pipes of following diameters with
cement joints in C. M. 1:1 proportion in proper position, grade and
66 alignment at all level as directed by Engineer-in-charge including Rmt 20.00 101.20
conveyance from stores to site of work, Jointing material etc. comp.150
Dewatering by pumping set of required capacity including temporary
67 platform carting pumping at site and fixing the same in position including HP/hr 200.00 21.07
all accessories, and fuel and labour etc. complete.
68 Providing and fixing in position cowel went to pipes. (B) 75mm dia. No 2.00 393.04
Door closers (Heavy type of 765 number) Hardwire or EveritePrabhat or
71 C.P. Brass toilet paper holder of stand and size No 6.00 220.83
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets
fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
74 C.P. Brass 1/2 turn flush cock 32 mm dia No 6.00 236.24
75 Abonite ball cock 25mm dia No 6.00 88.16
Applying priming coat of over new steel and other metal surface after and
including preparing the surface by thoroughly cleaning, oil grease, dirt and
other foreign mater and scoured with brushes fine steel wool, scrapers and
sand paper with ready mixed priming paint brushing red lead.
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brusing interior to give an even shade including
cleaning the surface an even shade including cleaning the surface of all
dirt, dust and other foreign matter.
For Gate :- Steel work, welded in built up sections framed work including
cutting, hoisting, fixing in position and applying a priming coat of red lead
78 paint. (A)In beams and joists, channels angles Tees, flats, with connecting kg 1200.00 91.08
plates or angle cleats as in main and cross beams. Hip and jack rafters,
purlins conneted to common rafters and the like
Description Unit Quantity Rate Amount
5000 Litre Capacity UG Ractangular Tank
"Preparing structural design of RCC Under Ground / Partially under ground
/ above high ground level Reservoir of required capacity as per relevant I.S.
standards and constructing the same, including excavation in all types of
soil strata (including rock) including shoring strutting if required, for loose
soil / to protect from collapse, casting 100 mm thick P.C.C. levelling course
in M-15, Refilling the pit with proper soil and disposing of the surplus stuff
at all lead. Including cement plaster in CM 1:2 withapproved water
proofing compound to all over inside container (i.e. walls, base, top
slab/dome bottom etc. all). Including all typesof labour and material
charges of lowering, laying, erecting / hosting and jointing of pipe assembly
to inlet, outlet overflow, washout and bye pass arrangement as per
hydraulic design. Providing and fixing accessories, CI Manhole frame and
cover, water level indicator, adequate cowl type ventilators or lantern type
ventilator with stainless steel jail. RCC chambers for valves. Providing and
applying three coats of cement paint / snowcem to the out side face of
structure. It also includes satisfactory water tightness test as per relevant
I.S. code and painting name of scheme and capacity on the tank as per
direction of engineer
Total cost (in Rs.) =
Milk Processing Unit
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5 m depth including sorting out and
1 stacking of useful materials and disposing off the excavated stuff upto 50 cum 93.00 122.99
Meter lead. (A) Loose or soft soil.
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting
2 out and stacking of useful materials and disposing off the excavated stuff cum 24.00 136.33
upto 50 Meter lead. (A) Loose or soft soil.
Filling available excavated earth (excluding rock) in trenches. plinth, sides
3 of foundations etc. in layers not exceeding 20 cm. in depth consolidating cum 68.36 136.92
each disposited layer by ramming and watering.
Providing and laying cement concrete (M-10) 1:3:6 (1-Cement : 3- coarse
4 sand : 6- hand broken stone aggregates 40 mmnominal size) and curing cum 26.00 2,968.91
complete excluding cost of formwork in (A) Foundation and Plinth
Providing and laying controlled cement concrete M.250 with and curing
complete including the cost of formwork and reinforcement for reinforced
concrete work in (A) Foundations, footings, Base of columns and Mass
Providing and laying controlled cement concrete M.250 with and curing
6 complete including the cost of formwork and reinforcement for reinforced cum 22.00 7,729.49
concrete work in (D) Columns, Pillars posts and struts, upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
7 complete including the cost of formwork and reinforcement for reinforced cum 25.00 6,176.56
concrete work in (C) Beams, Girders upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
8 complete including the cost of formwork and reinforcement for reinforced cum 32.00 6,237.40
concrete work in (C) Slabs. upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
9 complete including the cost of formwork and reinforcement for reinforced cum 2.00 7,223.22
concrete work in (C) Lintels. upto floor two level.
Providing and laying controlled cement concrete M.250 with and curing
10 complete including the cost of formwork and reinforcement for reinforced cum 1.00 6,202.27
concrete work in (C) Cantilever Chajja upto floor two level.
Providing and laying controlled cement concrete M-250 for RCC works
including the cost machine mixing, vibrating, scaffolding, incl. cost of form
work / shuttering but excluding cost of reinforcement etc. complete up to
floor 2 level for Stair- Steps and Sofit Slab
Providing and laying controlled cement concrete M-250 for RCC works
including the cost machine mixing, vibrating, scaffolding, incl. cost of form
work / shuttering but excluding cost of reinforcement etc. complete up to
floor 2 level for copping
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
Description Unit Quantity Rate Amount
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
Brick work using common burnt clay building bricks having crushing
strength not less than 35kg / Sq. C. M. in ramp, steps and Foundation &
Plinth in cement morter1:5 (1 cement : 5 coarse sand) including racking
out joints, curing, scaffolding required if any etc.complete, as directed.
Brick masonry in cement mortar (1:5) using common burnt clay building
16 bricks having crushing strength not less than 35kg/csmt including cum 105.00 3,489.80
scaffolding,curing, etc. complete for walls, parapets, etc. at all levels.
Providing and applying 15 mm thick cement plaster in single coat on brick
work with floating coat of net cement slurry for interior plastering of
pumphouse and outside plastering upto finished even and smooth in
Cement motar 1 : 3 (1 cement : 3 sand) including racking out joint curing,
scaffolding required if any, with necessary cement finishing etc. complete
20 mm thick sand faced cement plaster on walls upto height 10 metres
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8 mm thick finishing coat of C.M. 1:1 (1-cement :
sand) etc. complete.
Finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly
brushing the surface to removal dirt, and remains of loose powdered
materials etc. complete
Distempering (two coats) with oil bound distemper of approved brand and
manufacture and or required shade on undecorated wall surface to give an
even shade, over and including a priming coat with distemper primer of
approved brand and manufacturer after thoroughly brushing the surface
free from mortar dropping and other foreign matter also including
preparing the surface even and sand papered smooth.
Applying two coats of Birla(white cement based) or Asian (acryliclapy
putty) or equivalent & two coats of primer of approved brand and
21 manufacture on new wall surface to give an even shade including Sqmt 398.00 40.59
thoroughly brushing the surface free from mortar dropping and other
foreign matte rand sand papered smooth.
Providing 100 mm x 100 mm size vata in cement mortar (1:1) including
smooth finish, curing, etc. complete.
Providing and laying 50 mm thick heavy duty cement concrete flooring
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) with ironite powder including finishing with a floating of neat cement
Providing and laying Vitrified tiles 8 to 10 mm thick, 36'' x 36'' in flooring
24 treads of steps and landing laid on a bed of 12mm thick cement mortar 1:3 Sqmt 220.00 1,531.82
(1-cement : 3-coarse sand ) finishing with flush pointing in white cement.
Description Unit Quantity Rate Amount
Providing and laying Vitrified tiles 8 to 10 mm thick , in skrting risers of
25 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse Sqmt 6.00 1,592.40
sand) and jointed with white cement slurry
Providing and laying polished Kota stone slab flooring over 20 mm
(average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid
over and jointed with grey cement slurry including rubbing and polishing
etc. complete at Kitchen room & Store room. 30 mm thick
Providing and laying polished Kota stone slab 25 mm thick in riser of steps,
skirting Dedo & pillars laid on 10 mm thick cement mortar 1:3 (1 cement :
3 coarse sand) and jointed with grey cement slurry including rubbing and
polishing etc. complete
Constructing a cooking platform 60 cm. width and 70 cm high resting on
B.B.Masonry walls 23 cm.thick in C.M.(1:6) with (ii) Fixing black kadappa
stone 30mm thick laid on precast R.C.C. (1:2:4) slab with plastering on
exposed faces of wall in C.M. (1:4) etc complete.
Providing and fixing 35mm thick factory made moulded door shuter
consisting of solid core single leaff lush door of 30mm thickness, lipped
with 15mm (5mmx3) thick x30mm width on one stiles and top rail and
10mm (5mmx2) thickx 30mm width on the other stiles and bottom
rails.The inner panell aminated with 2mm thick termite proof, water proof
29 and fire resistant moulded PVC sheet with 2,4,6 raised panel design in smt 27.00 2,152.31
different plain and/or prelim colour so none side after routing the
moulded design on flush door and 2mm plain and/or prelim PVC sheet on
other side using rubber adhesive on flush door and solvent cement
adhesive on the PVC liping etc.complete as per direction of Engineer
incharge, manufacture’s specification and drawing.
Providing and fixing glazed louvered glass windows and ventilators
30 with teak wood frame 10cm. x 7cm. size including 3 coats of oil painting smt 1.00 4,434.35
to wood work etc.complete. with wooden louvers plank 12mm thick.
Providing and fixing M.S. grills of required pattern to wooden frames of
windows etc. with M.S. flats at required spacings and frame alround,
square or round bars with round headed bolts and nuts or by screws (A)
Providing precast cement concrete jali or louvers 40 mm thick 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size)
reinforced with 1.6 mm dia. Mild steel wire including roughening,
cleaning, fixing and finishing in CM 1:3 and curing, painting complete
33 Providing and fixing 160 PVC SWR pipes IS 13592 for Drain - 160 mm dia Rmt 98.00 515.27
Painting two coats including priming coat on new steel & other metal
34 surfaces with enamel paint, brushing, interior to give an even shade Sq.M. 100.00 92.17
including cleaning the surface of all dirt, dust, other foreign matter.
Providing throating or plaster drip and moulding to R.C.C. Chhajja as
instructed by Engineer in charge.
Description Unit Quantity Rate Amount
Providing and laying broken China Mosaic flooring for terrace using 12 mm
to 20 mm broken pieces of glazed tiles to be laid over Cement mortar 1:3
to plain or slope and to be tempered to bring mortar crème out upto
surfAEC using white cement including rounding of junctions and extending
them upto 15 cm. along the wall, clearing with water and oxalic acid etc. as
Extra for providing and mixing water proofing material in Cement concrete
37 per Quintal 90.00 49.16
in mix proportion recommended by the manufacturers.
Providing and fixing wash down watercloset (Europeantype,W.C.Pan) with
integral Por S trap including jointing the trap with soil pipei n Cement
Mortar1:1(1-Cement:1-fine sand) (Seal and cover to beme asured and paid
for separately) (A)vitreous China Pattern :(i) in white colour 32 dia. C. P.
brass half turn flush cock complete including earthwork, bed concrete of
1:4:8. , & Jet spray heavy duty with S.S. Braided hose 60 cm long
Providing and fixing flat back white colour vitreous china wash basin
mm x 400 mm size with CI brackets painted white. Wash basin shall have
15 mm dia GI supply pipe, overflow chase, 15 mm dia pillar cock and stop
cock with chromium plated bottle trap, Rubber ring and PVC pipe piece
39 upto wall plus 32 mm dia PVC waste pipe upto floor level connected to 32 No. 2.00 2,506.67
mm dia CI pipe below floor and connected to nearby floor trap complete
with unions and plumber's white soldered joints with necessary cleaning
eye, complete. All chases cut in wall for fixing pipes shall be made good in
Providing and fixing Flat Back Urinal (Hindware- 44 cm x 31.5 cm x
cm) or equivalent approved and of approved shade including fixing the
same in concealed CI brackets, CP spreader, CP dome shaped waste
coupling, CP bottle trap with flanges, CP angle cock flush pipe making inlet
and out let connections all complete as per the instruction of Engineer - In -
Providing and fixing 600 mm. X 450 mm. Bevelled edge mirror of superior
41 glass mounted on 6 mm. Thick A.C, sheet or plywood sheet and fixed to No. 2.00 859.41
wooden plugs with C.P. brass screws and washers
Providing, laying and jointing in true line and level U.P.V.C. Pipe (SCH-40)
for including fittings make PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall be fixed on the
42 wall with the help of clamp at every two metre C/C or shall be concelled as Rmt. 10.00 72.65
directed including necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost of all materials.
Description Unit Quantity Rate Amount
Providing, laying and jointing in true line and level 110 diametre U.P.V.C
(Type B) conforming to IS 13592-1992 with one end plain and other end
socketed with rubber ring, & fittings conforming to ISI 14735-1999 of
approved make for drainage system pipe line, pipe shall be jointed with
each other with rubber lubricant, pipe shall be fixed on wall using of PVC
clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at
every 2000 mm center to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc. including testing of
pipes and joints and jointed with adhesive solvent cement including cost of
Providing & fixing gun metal check or non return full way wheel valve
50 Providing and fixing brass screw down stop tap. (A) 15mm dia. No 7.00 205.83
Providing and fixing screw down bib taps of following size.(C)Gun metal
screw down bib tap. i) 15mm dia.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement: 2-
coarses and :4- graded stone aggregate 20 mm nominal size) foundation
concrete 1:3:6 mix (1-cement : 3-coarse sand : 6-Brick bats 40+50 mm size)
inside plastering 15 mm thick with Cement Mortar 1:5 (1-Cement : 5-
coarse sand)finished with a floating coat of neat cement and making
channels in cement concrete 1:2:4 mix (1-Cement: 2-Coarses and : 4-stone
52 aggregate 20 mm nominal size) finished smooth complete including curing No 2.00 11,042.74
and festing (i) Inside size 900mm x 1200 mm and 2.0 M. deep including C.I.
cover with frame size 560mm diameter total weight of cover and frame to
be not less than 128kgs. (Wt. of cover 64Kg. and Wt. of frame 64Kg.) (A)
With 230 mm thick walls of brick msonry using brick having crushing
strength not less than 35Kg./Sq.cm. in Cement Mortar 1:5 (1- Cement : 5-
Coarse sand) (1) A type depth 0.90 Metre for 150 mm diameter sewer.
Providing and supplying in standered length ISI mark rigid unplasticised
PVC pipes suitable for potable water with ringfit joint including cost of
rings, as per IS specification no. 4985/1988 including all local and central
53 taxes, transportation, freight charges,octroi,inspection charges, loading, Rmt 15.00 326.20
unloading conveyance to the departmental stores and including cost of
jointing material etc. complete Test pressure of 4 Kg./csmt of 160 mm dia
Providing and fixing cast iron (Spun) Nahni trap of the following nominal
diameter of self cleaning design with C.I. screaed down or hinged grating
including cost of cutting and making good the walls and floor 100mm inlet
and 50mm outlet. (C) 100mm dia.
Providing and fixing S.W. gully trap with C.I. grating brick masonry
chamber and water tight C. I. cover with frame of 300 mm x 300 mm size
(inside) with standard weight. (i) Square mouth traps.(B) 150mm x 100mm
size P or R type
Description Unit Quantity Rate Amount
Providing and fixing100mm size P or Strap for water closet squatting pan
56 including jointing the trap with the pan and soil pipe in cement Mortar1:1 No 4.00 332.52
(1-Cement : 1-Fine sand) (A) Vitreous China.
Providing and laying (to level or slopes) and jointing with stiff mixture of
57 Cement Mortar in proportion 1:1 Selt glazed stone ware pipes including Rmt. 40.00 317.28
testing of pipes and joints complete.(B)150mm dia.
Constructing brick masonry chamber for under ground C.I. Inspection
chamber and bends with bricks having crushing strength not less than
35Kg.Cm 2in C.M. 1:5 C.I. cover with frame (Light duty) 455mm x 610mm
internal dimensions total weight of cover with frame to be not less than
38Kg. (Wt. of cover 23Kg.) and Wt. of frame 15Kg.) (R.C.C. top slab e with
1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm size)
foundation concrete 1:5:10 inside plaster 15mm thick with cement mortar
1:3 finished smooth with a floating coat of neat cement on walls and bed
concrete etc. complete. (ii) Inside dimensions 500mmx700mm and 450mm
deep for pipe line with one or two inlets. (upto 10 ton)
Providing erecting and fixing double coated ISI water tank of required
59 capacity of approved manufacture with all necessary fittings and liter 1000.00 3.95
connection etc. complete on terrace.
Providing and constructing Sewer manholes, scraper manholes and unit
house connection chamber, as per the type design in brick masonry in C.M.
1:5 and inside and outside 20mm thick plastering in C. M. 1:3 necessary
100 mm coping with reinforcement in R.C.C.M. 200 fixing C. I. steps and
fixing manhole frame and covers (But excluding supply of manhole frame
and covers) over manholes and house connection chambers and fixing
Manhole covers (but excluding supplying of manhole covers) over scraper
manhole etc. complete, providing and fixing safety chain wherever
necessary as per the stipulations in the type design complete as per latest
CPHEEO manual.(excl. excavation). Manhole type "A" Circular type having
inside diameter of 1200 mm for depth upto 1.5 m depth (for 150 mm to
500 mm dia sewer) Manhole type "A" as above but upto 1.0 M depth.
RCC precast M.H. Frame & Cover Manufacture, supply & Delivery at store
or at site of work precast RCC M.200 Frame & cover suitable to drainage
61 M.H. and as per type design & Drawing including cost of reinforcement Nos 1.00 1,289.15
M.S. Angles or Flat, curing mold work etc. Frame suitable for 50cm
opening of MH (A) For Circular manhole (heavy duty)
Cover suitable for 50cm opening of MH (A) For Circular manhole (heavy
Providing and supplying ISI marked only Standard length Stoneware pipes
in standard lengths of following class and diameter including all taxes,
63 insurance, transportation, freight charges, octroi, inspection charges, Rmt 20.00 180.79
loading, unloading, conveyance to departmental stores, stacking etc.
complete. (IS - 651 / 1989) Class AA 150 mm Dia
Description Unit Quantity Rate Amount
Lowering, laying and jointing Stone Ware pipes of following diameters with
cement joints in C. M. 1:1 proportion in proper position, grade and
64 alignment at all level as directed by Engineer-in-charge including Rmt 20.00 101.20
conveyance from stores to site of work, Jointing material etc. comp.150
65 Providing and fixing in position cowel went to pipes. (B) 75mm dia. No 2.00 393.04
Door closers (Heavy type of 765 number) Hardwire or EveritePrabhat or
68 C.P. Brass toilet paper holder of stand and size No 6.00 220.83
Providing and fixing C.P. brass towel rail comlete with C.P. brass brackets
fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
71 C.P. Brass 1/2 turn flush cock 32 mm dia No 6.00 236.24
72 Abonite ball cock 25mm dia No 6.00 88.16
Applying priming coat of over new steel and other metal surface after and
including preparing the surface by thoroughly cleaning, oil grease, dirt and
other foreign mater and scoured with brushes fine steel wool, scrapers and
sand paper with ready mixed priming paint brushing red lead.
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brusing interior to give an even shade including
cleaning the surface an even shade including cleaning the surface of all
dirt, dust and other foreign matter.
Steel work, welded in built up sections framed work including cutting,
hoisting, fixing in position and applying a priming coat of red lead paint.
(A)In beams and joists, channels angles Tees, flats, with connecting plates
or angle cleats as in main and cross beams. Hip and jack rafters, purlins
conneted to common rafters and the like
Total cost (in Rs.) =
Soakpit & Septic Tank
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5 m depth including sorting out and
1 stacking of useful materials and disposing off the excavated stuff upto 50 cum 41.00 122.99
Meter lead. (A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting out and
2 stacking of useful materials and disposing off the excavated stuff upto 50 cum 35.00 157.08
Meter lead. (B) Dense or Hard soil
Providing and laying cement concrete 1:3:6 (1-Cement : 3- coarse sand : 6-
3 hand broken stone aggregates 40 mmnominal size) and curing complete cum 6.00 2,968.91
excluding cost of formwork in (A) Foundation and Plinth
Brick work using common burnt clay building bricks having crushing
strength not less than 35kg / Sq. Cm. in ramp, steps and Foundation &
Plinth in cement mortar 1:5 (1 cement : 5 coarse sand) including racking out
joints, curing, scaffolding required if any etc.complete, as directed.
Providing and applying 15 mm thick cement plaster in single coat on brick
work with floating coat of net cement slurry for interior plastering of
pumphouse and outside plastering of sump upto finished even and smooth
in Cement motar 1 : 3 (1 cement : 3 sand) including racking out joint
curing, scaffolding required if any, with necessary cement finishing etc.
complete as directed.
Providing and laying controlled cement concrete M.250 and curing
6 complete including the cost of formwork (Ply wood only) but excluding the cum 5.00 6,237.40
cost of reinforcement for reinforced concrete work in RCC SLAB
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
8 Manhole Cover C.I. Cover with frame 500mm x 700mm No 3.00 1,140.96
Total cost (in Rs.) =
Tube Well of 250 mm Dia. Depth 300 Rmt
Description Unit Quantity Rate Amount
Drilling 250 mm dia pilot borehole in Alluvial strata by DR Rig. From
mts to 350.00 mts
Conduction electrologing test of 250mm Dia. Borehole incl.carting
Reaming 250mm dia pilot borehole incl.Assembling lowering housing
casing Strainer pipe gravel packing etc.comp. 1) From 250/300mmdia. to
550mm dia. Borehole. rom 0.00 mts to
A) Development of Each water bearing Zones comes/across up to the full
depth Depth more than 186 mt.) by lowering 100 mm. Dia dropline &
mm dia.G.I. Airline for each zone with suitable capacity Air Compressor up
to the availability of Sand free discharge (w/o air comp.charge)
B) Development of above mentioned bore By air compressor 1100 cfm/300
5 PSI Capacity up to 6 hrs minimum until sand Free discharge of the bore Hrs 1.00 34,662.00
which ever is Letter
Manufacture,supply and delivery of ISI marked ERW M.S.Pipes conforming
to 4270/2001 (Min 7.10mm thickness)
Slotting of MS ERW blank pipe of following size having slot size as (including
unloading of blank pipes from truck & reloading slotted pipes into truck). Per
As above having slot size as 6.75 cm x 6.35 cm x 1.59 Slot
8 Supply and laying of gravel having size 4 mm To 6 mm Size. cmt 34.28 2,029.00
Supply and laying of clay ball made from sticky clay Of size 25 mm To
mm & quality Certified by Hydrologist.
Providing & fixing MS bail plug having length 0.45mtr from medium
class pipe as per ISS suitable for 250 mm dia pipe
Providing & fixing Bore plug having 100mm height made from MS plate
with 3 holes at equal distance on circumference for nut bolts type ,locking
arrangement with nuts bolts & locks nuts of std make complete from
5mm thick MS plate for 250mm dia pipe
Providing & fixing clamp made from MS plate with 3 holes on
12 either side with nuts bolts of std make for 250 mm dia pipe (900mm * 100 No 1.00 2,017.73
mm * 16 mm) per pair
Providing & fixing Steel Bent Plate for ERW pipe of 250 mm dia pipe
14 Supply and laying of cement MT 1.50 6,302.00
Cement sealing as recommended by Hydrologist (without cost of cement &
By means of mud pump.
Water analysis charge for chemical Analysis of water from Government
approved Labs (i.e. GJTI) and as directed by Engineer In-Charge
Description Unit Quantity Rate Amount
Providing dust and vermin proof MS cabin having two compartments, one
for panel board and other for energy meter and fuse unit with required
locking arrangement , minimum degree of protection IP 52 as per IS
fabricated from CRCA sheer steel minimum thickness for base frame /
17 channel / gland plates for 3 mm for load bearing members,1.6 mm for No 1.00 23,406.60
ineternal members including cutting, bending, drilling, welding, riveting
with ineternal partitions.The sheet steel enclosure shall be powder coated
as per applicable standard with shade as required with finish thickness of
paint film not less than 80 microns (1) 1.5m*1.25m*0.6m
Providing, supplying, errection, Testing and commissioning of Electric
motor driven borewell submersible pump set confirming to IS 8034 and
motor confirming to IS 9283 working at 3 phase 400 / 440 volt 50 Hz AC
supply & 2900 RPM. with Discharge -240 LPM, Head - 250 mtr, Horse
power -25 HP. Cat
(1 Nos For SITC & 1 Nos for Supply Only) (1W + 1S)
Auto transformer starter suitable for local & remote pump control
application consisting of Auto Transformer (vacuum impregnated, air
cooled having three (3) tappings at 50%, 65% and 80%), incomer
19 MCCB / MPCB, overload relay and contactors as per Type II coordination No 1.00 24,276.00
including digital MFM with RS 485 communication port, analogue
type ammeter with selector switch, run hour meter, required protective
relays & control accessories. A. T. S. from 21 to 30 HP
Providing and supplying, lowering, Layig and Jointing ISI mark G. I. pipes
with Couplings of following class and diameter including all taxes,
20 insurance, transportation, freight charges, octroi, inspection charges, Rmt 230.00 1,031.10
loading, unloading, conveyance to departmental stores, stacking etc.
complete. (IS -1239) (V) 100mm dia
PVC insulated flat / round submersible copper cables PVC insulated flat
submersible cable as per detailed technical specifications of conforming
to IS 694, IEC 60227 /
Total cost (in Rs.) =
Furniture arrangement at different Building
Description Unit Quantity Rate Amount
CONFERENCE TABLE :- Supply & fixing conference table made as described
below : Top thickness 37.0 (18mm + 18mm ply +1mm laminate).Table top
made in various segments (600mm depth). Edge profile waterfall edge
10mm radius on top edge and 5mm at bottom. Partly 6mm thick corian
sheet to be provided as per detail drawing. Vertical panel: Made from
36mm PPB (18+18) having a straight profile with half round edges and clad
with 0.6mm thick post forming. Modesty panel:
1 Made from 18mm thick particle board with 1mm thick laminate,inner side Rmt. 18.00 3,275.00
with balancing veneer.
Wire Carrier: Made from 0.6mm thick CRCA painted.
Carrier cover: Made of 12mm thk. MDF painted all over.
Entire work shall be carried out as per the detailed technical specifications,
drawings and as per the instruction of Engineer-in-Charge. A Supply & fixing
of conference table of 26 seaters (1350mm x 600mm for one module of
two seaters & 675mm x 600mm for one seater ).
Supply & fixing of conference table of 6 seaters (4500mm x 750mm for one
2 module of two seaters & 675mm x 600mm for one seater) Complete with Rmt. 5.00 3,275.00
technical specification.
RECEPTION TABLE WITH PADESTAL Providing & fixing reception table
made as described below: Counter: At 1050 mm height 12mm thick
frosted glass with crystel edge. Glass to be rest on table working top with
25mm dia SS pipe with sturd.Work surface : At 725 mm height made from
37mm th. Ply wood with 1.0mm thick laminate on top & open
edges.Modesty panel: Below work surface 18mm thick ply with
1.0mm thick laminate. Or shera board panel duly finished in
monocoat polish.Verticle box-18mm thick ply with 6mm thick corian
sheet. Entire work shall be carried out as per the detailed
technical specifications, drawings and as per the instruction
of Architect.Padestal in laminated finish. (2 set of drawer box). Pedestal
3 made up of 18 mm thick ply wood 1.0mm thick laminate with PVC lipping Rmt. 17.50 20,282.00
on all edges for top panel, side panel, front skirting and fascia for (top,
middle & file) drawer. Drawer made up of 18 MM thick ply wood with
1.0mm thick laminate with PVC lipping on all edges for back panel,
bottom panel of pedestal bo you NRC of 70% , The cavity of framework
should be inserted with acoustical foam. the end situation or edge
closing at all windows and doors, at skirting level and at ceiling leel
shall be executed with natural wood patta with color matching
melamine polish. the cut Rate is inclusive of telescopic channel of ebco
make or equivalent for supporting drawer. Multi purpose lock of
Vijayan/Godrej make. Key board tray of Ebco make with mouse tray. CPU
trolley: M.S.powder coated trolley. Complete with technical specification.
Description Unit Quantity Rate Amount
CENTER TABLE (0.9 x 0.6m) Providing and supplying modular table as
below specification:Table top 10mm thick float glass with bevelled
4 edge. Top to be rest on 25mm dia. S.S. brush finished leg. Steel frame Nos. 4.00 3,800.00
height is 450mm .Top in Clear Glass of 10mm thk with edge polished of size
: 900 mm x 600 mm x 450 mm Complete with technical specification.
CORNER TABLE Providing & supplying of 750 mm x 750 mm corner table
with table top 19mm ply with 1.0mm thick laminate with solid ghana
5 teak wood leg.dully finished with mono coat polish. complete as per the NOS. 4.00 4,000.00
detailed technical specifications, drawings and as per the instruction of
Architect Complete with technical specification.
STORAGE CABINET Supply & fixing storage cabinets in completely knock
down fittings as per described below specification: Entire body & shutter
(openable or sliding) to be made from 18mm thick pre-laminated particle
board with 2mm thick PVC edge beading matching the laminate.
Adjustable shelves of 400mm depth to be provided with SS rod for file
hanger system as required by Shelves to be made from pre-laminated
particle board. All open edges to be finished with 2mm thick PVC
6 edge beading matching the laminate. Complete with all necessary Smt. 30.00 6,610.00
hardware & fittings such as lock, SS brush finish D type handles, SS auto
hinges, of approved make etc. complete as per the detailed technical
specifications, drawings and as per the instruction of Engineer-in-charge.
Length x height (bottom of false ceiling) to be taken for measurement
purposes. The contractor will have to take the exact dimension between
the walls before supplying the storage units.Complete with technical
specification. A Full height storage.
7 Middle height storage Smt. 30.00 6,693.00
8 Low height storage Smt. 30.00 6,610.00
CHAIRS : HIGH BACK CHAIR - MODEL : CHE - 331 Supply and erecting
synchro tilt mechanism with Any position locking arrangement, Nylon mesh
back for air circulation, 3 steps up armrest position to suit your posture,
Anti topple chrome polished base, Class- 3 gas lift for seat height
adjustment & glass filled nylon castors for smooth movement, 45 dc mould
cushion in seat, waterfall design seat for better leg suport, Unique design of
back with Mechanical lumber support adjustment device, 4 way
adjustable head rest & S shaped back design to support the spine
MEDIUM BACK CHAIR - MODEL : TOR - 5002 Supply and positioning push
back with single back lock system, PP Fix Arms, Seat cushioned & Back in
black Net/Mesh, Powder coating metal base with twin wheel nylon
castors, Gas lift for seat height adjustment
HIGH BACK ITO CHAIR - MODEL: MAR - 1011H SS fix arms, Multiple point
11 locking system with synchro mechanism, Gas lift for seat height Nos. 6.00 7,820.00
adjustment, chrome base with twin wheel nylon castors
Description Unit Quantity Rate Amount
MEDIUM BACK CHAIR - MODEL : Priviya - 7003 Supplying and provided
medium back chai with Cushioned Seat & back, PP outer back cover, PP
12 Fix Arms, Single back lock, Push back mechanism, gas lift for seat height Nos. 6.00 4,140.00
adjustment, five prong PP base
with twin wheel nylon castor-
STAFF CHAIR - MODEL- priviya-7001 Supply & positioning SS fix arms,
Multiple point locking system with synchro mechanism, Gas lift for seat
height adjustment, chrome base
with twin wheel nylon castors
CONFERENCE ROOM CHAIR Suppling & positioning cushioned Seat
Black Mesh back,fix pp handle, Synchro mechanism with single back
14 lock, gas lift for seat height adjustment, five prong Nylon base with Nos. 10.00 4,175.00
twin wheel nylon
FIX VISITORS CHAIR - MODEL : VIT-1002 Suppling and positioning fix chair
with Seat cushion & plastics back with 16 gauge CRC capsule pipe.
SOFA :- Supplying & positioning of sofa as described below: the side
frame assembly is fitted to the two ends of the connecting beam assembly
to form the leg-cum-armrest assembly.The seat rest assembly
consists of a fabricated inner-frame assembly in-situ moulded with
Polyurethane foam.The complete moulded backrest assembly is
covered with a replaceable fabric upholstery cover. The adjustable
16 glide is injection moulded in black Nylon & fitted to the front end of side Nos. 2.00 11,500.00
frame assembly along with ABS moulded adjustable glide base to take
care or unlevelled floor surface etc, complete as per
manufacturers specification, detailed technical specifications,
drawings and as per the EIC/ Architect. Complete with technical
specification and drawing.Supply & positioning three seater Sofa of
2015mm width, 945mm height, depth 920mm & seat height 450mm.
Supply & postioning of synthetic leather fully upholstered sofa made up of
polyester fibre wadding 175 GSM (18 mm), PU foam of 32d, 28d, 23d
in various positions. Expanded PF sheet for load distribution in seats.
Durable rubber webbings of 50 mm & 70 mm. Cotton webbing on
wooden surface to prevent sharp edges. Commercial ply -
17 12 to 15 mm as per design requirement. Pinewood of various Nos. 2.00 25,900.00
thickness and length, duly dried as base structure. All structures are joined
with stapling. etc, complete as per manufacturers specification, detailed
technical specifications, drawings and as per the EIC/ Architect.
Supply & positioning three seater Sofa of 1830mm width, 750mm height,
depth 783mm & seat height 450mm.
Description Unit Quantity Rate Amount
Supply & postioning of synthetic leather fully upholstered sofa made up of
polyester fibre wadding 175 GSM (18 mm), PU foam of 32d, 28d, 23d
in various positions. Expanded PF sheet for load distribution in seats.
Durable rubber webbings of 50 mm & 70 mm. Cotton webbing on
wooden surface to prevent sharp edges. Commercial ply -
18 12 to 15 mm as per design requirement. Pinewood of various nos 2.00 11,500.00
thickness and length, duly dried as base structure. All structures are joined
with stapling. etc, complete as per manufacturers specification, detailed
technical specifications, drawings and as per the EIC/ Architect.
Supply & positioning one seater Sofa of 900mm width, 750mm height,
depth 783mm & seat height 450mm.
M. S PERFORATED BENCH Providing and Supplying sofa as below
specification. Metalic understructure with Metal Arms and Legs with
silver gray finish powder coating with dimention as indicated in the dwg.
PU moulded foamin seat & back of 62 density Under
seat parallel support min. 14 gauge square pipes duly powder coated.
* Glide screw at the bottom for level adjucement. Two seater
ROLLER BLINDS Providing & fixing roller blinds of following specifications:
Eco black out Composition: 100% POLYESTER; Coating: PIGMENTED
20 ACRYLIC; Width: 290CM/250CM/220CM/ 180CM/10CM; Thickness: Smt. 60.00 860.00
0.45MM ±5%; Weight: 330GSM ±5%; Light Fastness: >7 (BLUE WOOL
SCALE), FULLY FADE RESISTANT.
FALSE CEILING :- TILE BASED GRID CEILING Reopen existing tile base
false ceiling & fixed it higher lvl. (approximate 150mm to 800mm )
21 Complete with all materiale.no extra cost to be given for extra Smt. 150.00 269.00
hardware,material etc.Complete with
technical specification.
GYPSUM BOARD CEILING Supply and fixing seamless ceiling with Gypboard
of 12.5 mm thick, fixed by using 25 mm long dry wall screws to the under
side of the suspended G. I. channels grid. comprising of main, intermediate
and perimeter runners, approximate sizes for the same are 80 x 26 x
22 mm @ 450 centre to centre, 45 x 15 x 0.09 mm @ 1200 centre to centre Smt. 150.00 732.00
and 20 x 29 mm respectively. Grid is suspended by G. I. soffit cleat (37 x
x 1.6 mm) using metal expansion fasteners of 12.5 mm dia, 35 mm deep,
6 mm dia bolt. G. I. connecting clips and other accessories to comply
with I. S. 2095 - 1982 and as per manufacturer specifications.
Description Unit Quantity Rate Amount
WALL PANELING :- FOR CONFERENCE Providing and Fixing Laminated MDF
Board / Pine wood Acoustical
Grooved Stats panels with lineal perforation on wall. The panels shall be
fire resistant grade with one site decorative wooden grain design/ or Plain
Laminated and rear side without laminate, with board size of 2400 mm x
140 mm x 16.5 mm with 2 to 3 mm wide and 7 mm deep slats ( grooves) at
16 mm c/c pitch , tongue and groove edges for semless mounting having
density of min 800 kg/m3. the back of the panels are perforated with
mm diameter circular holes at 32 mm c/c which reaches till the 3 x
groove, Panel is to be fixed on 18 framework with screw fixed horizontal/
vertical to cross channel 20 mm at every 600mm c/c with center &
edge bracket in toughe & groove system on the frame work shall be
fixed on wooden ( chill wood) planks which shall be fixed into wall and
which shall create true line and level .The thickness of wooden frame shall
be such that appx 25 mm acoustical foam is to be provided beneath
acoustical panels which gives you NRC of 70% , The cavity of framework
should be inserted with acoustical foam. the end situation or edge closing
at all windows and doors, at skirting level and at ceiling leel shall be
executed with natural wood patta with color matching melamine
polish. the cut out require for fixing swith boards, light points, AC grills etc.
shall be executed as per site condition and as per site engineer's
intstruction without any extra cost.
24 DECORATIVE LIGHT FIXTURES Cendilior light fitting Nos. 12.00 3,000.00
25 LED strip with driver supply Nos. 20.00 300.00
Total cost (in Rs.) =
Electrical and Instrumentation Work
Description Unit Quantity Rate Amount
11 kV Two Pole Structure Assembly:
SITC of 11 kV double pole 9 meter high structure made of 6" X 3"
'I" section girder, 4" X 2" channels, clamps, nuts, bolts, stay wires
including earthing system with following accessories duly connected with
ACSR conductors as per approved drawing & in compliance with
requirement of IEC.
(a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP)
tubes: 1 Set (01 piece per phase).
(b) 11 kV, 400 A G.O.D. switch complete with earth switch,
insulators, operating handle with galvanised pipe, square bar: 1 Set.
(c) 11 kV lightning arrestor with clamps: 3 Nos.
(d) 11 kV Disc Insulators (70KN): 3 Nos.
(e) 11 kV Pin Insulators (5KN): 3 Nos.
(f) 20 mm dia. GI Stay Sets Complete: 2 Set.
Supply of 500 KVA Outdoor type Compact Substation consisting of
Transformer, HT switchgear and LT Switchgear and confirming to IEC-
62227. a) Transformer: 500 KVA Copper wound 11KV
/433 V DYn11, Dry Cast resin type Transformer with tapping range +10 to -
10% @ 2.5% ( with tolerance), class F , with surge restorers, Digital WTI,
IS1171 as per b) HT Compartment: 11KV, 21kA for 3 Sec . 630 A 50 Hz, gas
insulated VCB in SS tank in sheet enclosure having provision for one no.
direct connection of Incoming supply cable upto 300sq mm and one no.
VCB ( Manually charging & closing) in series with LBS between VCB and
Transformer, Self Powered Relay 3 O/C
+1 E/F Relay type CSPR-V5, mechanical ON/OFF indicator, trip coil
Manual Close & Trip PB, live cable indicator, mechanical interlocks, pad
locking facility, SF6 gas manometer, cable boots, 3 nos.
CTs with Ratio -/1A, Cl: 5P10, 2.5 VA for protection c) LV side compartment
no. ACB of 800A, 50kA, 4Pole, Microprocessor based release with
arrangement for bottom cable termination
( 100% for phase & 50% for N, Current density 1A/ sq mm) The
enclosure should be of IK10 type.The Enclosure shall construction shall
be GI of thickness at least 1.6/2mm. The enclosure shall be Powder
Coated. Each compartment will be provided with the door and pad
locking arrangement. The Compartment illumination lamp with door
operated switch shall be provided for each compartment. The
Transformer compartment will have IP-34 ingress protection,
whereas the HT/LT compartment will have IP-54 protection. The
connection between HT and Transformer shall be by 3 runs of single core
aluminium cable and between Transformer to LT switchgear shall
Description Unit Quantity Rate Amount
11 kV (Earthed / Unearthed) Grade Cable- Aluminium Conductor
Supply, laying, testing & commissioning of 6.35 / 11 kV (E) grade,
XLPE insulated, stranded Aluminium conductor, galvanised steel flat strip
/ round wire armoured, extruded PVC type ST2 sheathed, heavy duty cable
3 (to be laid on wall surface with necessary clamps / in existing cable mtr 100.00 1,045.00
trench / cable trays / conduit / pipe sleeves at road crossing or floor
as per site requirement) conforming to IS: 7098 (Part2)
& IEC: 60502 (Part-2) of following sizes: 3 Core x 240 Sqmm
Two Pole Structure to CSS
Cable Terminations / Jointing Kits for 6.6 kV (UE) / 11 kV (E) grade XLPE
Providing & fitting heat shrink cable termination / jointing kits for 6.6 kV
(UE) / 11 kV (E) grade XLPE insulated cable including necessary
4 earth connectivity connection, material & consummables making Nos 4.00 6,763.00
the termination/ joint complete ensuring the joint resistance is within
the permissble limit as per IS, of following types & sizes: Outdoor
Terminations Kit suitable for - 3 Core x 240 Sqmm Two Pole Structure to
Making trench in soft soil of suitable width of 90 cm deep for laying cable
5 or locating the fault all over the run and back filling the same and making Mtr 180.00 46.46
the surface as normal ground.
Covering of cable with second class bricks or cement tiles laid cover the
6 cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand Mtr 180.00 133.31
above & below cable (16 bricks per meter)
Description Unit Quantity Rate Amount
MEDIUM VOLTAGE PANEL BOARD (PMCC)
SITC of PMCC Panel (50kA) complete in all respects as per SLD /
Specification / IS and including following as minimum:
(1) Three nos. FP 800A Microprocessor MCCB for I/c with Digital
Voltmeter with Voltmeter selector switch, Digital power Factor Meter,
Digital Ammeter with Ammeter selector switch,MFM with RS-485,
R,Y,B,on,off,trip Indicating lamps & ON, E-STOP, Reset Pushbutton, etc,.
(2) Two Nos Bus Coupler FP 800A.
(3) 800 A TPN Main busbars. (main & auxilary busbars size with current
density 0.8A/Sq.mm)
(4) Two nos. 320A FP Microprocessor MCCB feeder for APFC Panel.
(5) One nos. 200 A FP Microprocessor MCCB feeder for PDB-1 Panel
(For Milk Storage Unit Building)
(6) One nos. 63 A FP Microprocessor MCCB feeder for PDB-2 Panel (For
Veterinary Hospital)
(7) One nos. 125 A FP Microprocessor MCCB feeder for PDB-3 Panel (For
(8) One nos. 160 A FP Microprocessor MCCB feeder for PDB-4 Panel (For
Milk Processing Unit)
(9) Twelve nos. 63 A FP Microprocessor MCCB feeder for Panel (For all
Building Supply)
(10) Three no. 63A TPN MCCB feeders (for LDB, PDB & Spare)
(11) One no. Outdoor lighting LDB feeder with 32A TPN 'C' curve MCB with
32A contactor & Time switch.
(12) 2nos. 100A TPN microprocessor MCCB feeder for Borewell Feeder &
(13) 6nos. 800A/1A, Cl.-1 metering CT
(14) 2nos. 800A/1A, Cl.-1 metering CT for APFC Panel
For Distribution Board Building Wise
Providing and erecting Sheet Steel powder coated MCB distribution
board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without
MCB to house appropriate nos. of MCBs.(The DBs should be used of
8 same company of MCB to be used) suitable for Nos. 12.00 3,096.28
(B) Three phase incoming and single phase horizontal type outgoing
Per phase isolation type (PPI)
(a) Single door
For 12 Nos for all Building
For Distribution Board Building Wise
Providing and erecting Approved make RCCBs conforming to IS: 12640 and
having sensitivity of 30 mA and Short Circuit withstand capacity of 10 KA
and suitable for operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance feature & do not
incorporate any electronic component for following Max. rating erected as
(ii) 63Amps. FP - Cat. III, Incomer For 12 Nos for all Building
Description Unit Quantity Rate Amount
For Distribution Board Building Wise
Providing & erecting 240 V MCB double pole switch for lighting Load
(B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity
Double pole 6A to 32A Cat.III
For 12 Nos for all Building (4 Nos for each Building)
For Distribution Board Building Wise
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having following capacity
Double pole 6A to 32A Cat.III
For 12 Nos for all Building (4 Nos for each Building)
For PDB-1, 2, 3, 4 &
Providing and erecting Sheet Steel powder coated Vertical MCB
distribution board (VTPN) flush
/ surface mounted double door (IP54) fitted with insulated copper busbar,
isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS
12 5486-1986,IP-54 suitable for 250 AMP TPN MCCB + RCCB as incomer and Nos 5.00 21,871.53
three phase outgoing as per following .(The DBs should be used of same
company of MCB to be used)
(D)12 way outgoing
For PDB-1, 2, 3 & 4 (Milk Storage Unit, Veterinary Hospital, Milk Parlor &
Milk Processing Unit & Admin Building)
Providing and erecting Approved make Four pole moulded case circuit
breaking capacity ICU of 35 KA. at 415 V. having Normal current
13 rating 200A. with variable Thermal & magnetic release suitable to work Nos 2.00 16,062.28
on A.C.supply 50 c/s. with all internal connections, spreader tinned copper
& complete erected in existing 16 G.M.S.housing ICS=100% of ICU only Cat
For PDB-1 & 4 Incomer (Milk Storage Unit & Milk Processing Unit)
Providing and erecting Approved make Four pole moulded case circuit
breaking capacity ICU of 35 KA. at 415 V. having Normal current
14 rating 125A. with variable Thermal & magnetic release suitable to work Nos 1.00 7,977.28
on A.C.supply 50 c/s. with all internal connections, spreader tinned copper
& complete erected in existing 16 G.M.S.housing ICS=100% of ICU only Cat
For PDB-3 Incomer (Milk Parlor)
Providing and erecting Approved make Four pole moulded case circuit
breaking capacity ICU of 35 KA. at 415 V. having Normal current
15 rating 25A to 100 A. with variable Thermal & magnetic release Nos 2.00 6,113.28
suitable to work on A.C.supply 50 c/s. with all internal connections,
spreader tinned copper & complete erected in existing 16 G.M.S.housing
ICS=100% of ICU only Cat III - 63 A
For PDB-2 & 5 Incomer (Veterinary Hospital)
Description Unit Quantity Rate Amount
For PDB-1, 2, 3, 4 &
Providing & erecting 240 V MCB double pole switch for lighting Load
(B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
16 existing box having following capacity Nos 20.00 276.13
Double pole 6A to 32A Cat.III - 4 Nos for Each PDB
For PDB-1, 2, 3 & 4 (Milk Storage Unit, Veterinary Hospital, Milk Parlor &
Milk Processing Unit & Admin Building)
For PDB-1, 2, 3, 4 &
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
17 existing box having following capacity Nos 20.00 297.13
Double pole 6A to 32A Cat.III - 4 Nos for Each PDB
For PDB-1, 2, 3 & 4 (Milk Storage Unit, Veterinary Hospital, Milk Parlor &
Milk Processing Unit & Admin Building)
MEDIUM VOLTAGE CABLES
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
18 necessary clamps or in existing trench / pipe of following size of Mtr 540.00 1,387.33
(J) 3 1/2 core 300 Sq.mm ( 150 Sq. mm 1/2 core) (3Run for CSS to
LT Panel and DG set to LT Panel)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
19 necessary clamps or in existing trench / pipe of following size of Mtr 1200.00 187.12
(B) 4 core 25 Sq. mm (20 nos Building)
Providing and erecting XLPE (IS:7098)(I)-88 ISI armoured cable
multistrand / Solid Aluminium conductor for 1.1 KV. to be laid on
20 wall with necessary clamps or in existing trench / pipe of following Mtr 50.00 123.12
4C x 6 sq. mm. A2XFY Cable ( For Outdoor Lighting LDB)
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable
multistrand Aluminium conductor for 1.1 KV. to be laid on wall with
necessary clamps or in existing trench / pipe of following size of
(H) 3 1/2 core 185 Sq. mm ( 95 Sq. mm 1/2 core) (1Run for LT Panel to PDB-
(B) 3 1/2 core 35 Sq. mm ( 16 Sq. mm 1/2 core) (1Run for LT Panel to PDB-2
(D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) (1Run for LT Panel to PDB-
G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) (1Run for LT Panel to PDB-
Providing and, fixing heavy duty flange type brass double compression
type cable gland with rubber ring for PVC insulated armoured cable
25 complete with out going tails, insulating tape etc for following size of Nos. 12.00 278.39
(I) 3 & 1/2 core 300 Sq. mm (2Run for CSS to LT Panel and DG set to LT
Description Unit Quantity Rate Amount
Providing and, fixing heavy duty flange type brass double compression
type cable gland with rubber ring for PVC insulated armoured cable
26 complete with out going tails, insulating tape etc for following size of Nos. 40.00 66.11
(B) 4 core 25 Sq. mm (20 nos Building)
Providing and, fixing heavy duty flange type brass double compression
type cable gland with rubber ring for PVC insulated armoured cable
27 complete with out going tails, insulating tape etc for following size of Nos. 2.00 38.11
4C x 6 sq. mm. A2XFY Cable ( For Outdoor Lighting LDB)
28 (G) 3 & 1/2 core 185 Sq. mm (2 for LT Panel to PDB-1) Nos. 2.00 236.30
29 B) 3 & 1/2 core 35/50 Sq. mm (2 each for LT Panel to PDB-2 & 5) Nos. 4.00 75.11
30 (C) 3 & 1/2 core 70 Sq. mm (2 for LT Panel to PDB-3) Nos. 2.00 102.15
31 (F) 3 & 1/2 core 150 Sq. mm (2 for LT Panel to PDB-4) Nos 2.00 189.30
Solder less crimping type Aluminium lugs conforming to IS suitable
for cable of following size evenly crimped with high pressure tool &
connected to switchgear terminals with brass/cadmium plated nut bolts in
an approved manner.
(K) 300 Sq.mm (2Run for CSS to LT Panel and DG set to LT Panel)
Solder less crimping type Aluminium lugs conforming to IS suitable
for cable of following size evenly crimped with high pressure tool &
33 connected to switchgear terminals with brass/cadmium plated nut bolts in Nos. 160.00 15.03
an approved manner.
(B) 4 core 25 Sq. mm (20 nos Building)
Solder less crimping type Aluminium lugs conforming to IS suitable
for cable of following size evenly crimped with high pressure tool &
34 connected to switchgear terminals with brass/cadmium plated nut bolts in Nos. 8.00 6.01
an approved manner.
4C x 6 sq. mm. A2XFY Cable ( For Outdoor Lighting LDB)
35 ( I ) 185 Sq.mm. (for LT Panel to PDB-1) Nos. 8.00 80.15
36 (D) 35/50 Sq.mm. (for LT Panel to PDB-2 & 5) Nos. 16.00 20.03
37 (E) 70 Sq.mm. (for LT Panel to PDB-3) Nos. 8.00 25.06
38 (H) 150 Sq.mm. ( For LT Panel to PDB-4) Nos. 8.00 61.11
Providing and fixing approved make Perforated C type cable tray. Made
from sheet steel. The cable tray should be single or double bended as per
required and as per IS 2062/1079 and shall be coated with hot dip
39 galvanizing as per IS 2629/4759. with max 17.5% perforation with coupler Mtr. 100.00 357.30
plate / Fish plate and GI hardware like nut - bolt and washers etc. erection
with necessary support( included) as per Specification and as per
instruction of engineer in charge.
(2) 100 X 50 X 1.6 mm Thick
Description Unit Quantity Rate Amount
Providing and fixing approved make 'T' Junction for Perforated C type cable
tray. Made from sheet steel. The Junction should be bended as per IS
2062/1079 and shall be coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with coupler plate / Fish plate and
GI hardware like nut - bolt and washers etc. erected on existing support as
per Specification and as per instruction of engineer in charge of following
(2) 100 X 50 X 1.6 mm Thick
Providing and fixing approved make '90° Elbow' for Perforated C type cable
tray. Made from sheet steel. The Junction should be bended as per IS
2062/1079 and shall be coated with hot dip galvanizing as per IS
43 2629/4759. with coupler plate / Fish plate and GI hardware like nut - bolt Each 5.00 115.13
and washers etc. erected on existing support as per Specification and as
per instruction of engineer in charge.
(2) 100 X 50 X 1.6 mm Thick Thick 90° Elbow
44 (1) 50 X 50 X 1.6 mm Thick Thick 90° Elbow Each 20.00 98.13
Providing and fixing approved make 'Cross over Junction' for Perforated C
type cable tray. Made from sheet steel. The Junction should be bended as
per IS 2062/1079 and shall be coated with hot dip galvanizing as per IS
2629/4759. with max 17.5% perforation with coupler plate / Fish plate and
GI hardware like
nut - bolt and washers etc. erected on existing support as per Specification
and as per instruction of engineer in charge.
(2) 100 X 50 X 1.6 mm Thick Cross Junction
46 (1) 50 X 50 X 1.6 mm Thick Cross Junction Each 20.00 191.13
CHEMICAL EARTHING SYSTEM
Supplying & erecting in earthpit of minimum bore dia. 225mm size
approved make Safe Earthing Electrode consisting Pipe-in-Pipe
Technology as per IS 3043-1987 made of corrosion free hot dipped
G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250 Micron
galvanising, connection terminal dia of 14 mm with constant ohmic
value surrounded by highly conductive compound with high charge
47 dissipation suitable for following type of applications with chamber and Nos 30.00 7,028.82
heavy duty cover.(approved make OEM has to submit test certificate
including value of earth resistane of installation.
[B] For Electrical installation up to 11 KV located in other than
normal soil i.e. Soft Rock, Marshy Soil etc.
-Length of Pipe : 2 mtr
-Back filling Compound :1 no. Bag of 25 Kg.
(Each for body of 2 CSS,LT Panel, 2 APFC Panel & 20 nos PDBs, 2 Nos for DG
[C] For Electrical Installation covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant & Sensitive Computer System
(like Automation, SCADA) i.e. independent Earthing located in other
48 than normal soil i.e. Soft Rock, Marshy Soil etc.. Nos 4.00 10,494.73
-Length of Pipe : 3 Mtrs.
-Back filling Compound :2 nos Bags of 25 Kg. (2 Nos Each for neutral of
Description Unit Quantity Rate Amount
Providing and erecting required size HOT deep Galvanised iron strip for
earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc.
using proper clamp.
(Each for body of LT Panel, 2 APFC Panel & 20 nos PDBs)
Providing and erecting required size Copper strip for earthing of H.T. OCB /
50 ACB/ Transformer, LT panel board, Motors etc. using copper clamp. Kg 90.00 787.34
(Each for body of 2 nos CSS & DG Set)
51 Providing and erecting HOT deep Galvanised iron strip wire 8 to 16 SWG. Kg 20.00 77.17
Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green)
both are of .ISI marked
1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr
length, in below type of pipe erected with 6A Modular type switch and
hum free EME step type electronic fan regulator mounted and
accessories with earth continuity of following type erected on
PVC / Metallic/Wooden box, single mounting base frame covered
with textured/metallic/white front plate modules erected on / in wall
/ ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete Cat. III
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multi
strand copper wires up to 10 mtr length , in below type of pipe erected
with 6A Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC / Metallic/Wooden box,
single mounting base frame covered with textured/metallic/white front
plate modules erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete Cat. III
Point wiring for Two Way Controlled Light Point with 2-1.5 sq.mm &
earth wire of 1.5 sq.mm (green) both are of .ISI marked 1.1 KV grade
FRLS PVC insulated multi strand copper wires erected in below type
of pipe with 6A Modular type switches and following type of
accessories erected on PVC / Metallic/Wooden box, single mounting
base frame covered with textured / metallic/white front plate modules
erected on / in wall / ceiling as per pipe erected. with necessary
batten/angle holder or ceiling rose or H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on
wall/ceiling complete Cat. III
Description Unit Quantity Rate Amount
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green)
both are of ISI marked 1.1 KV grade FRLS PVC insulated multi strand copper
wires up to 10 mtr length, in below type of pipe erected complete with
Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden box
covered with appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of accessories.
[II] For 16A Plug and 16 amp switch with 2-2.5 sq.mm Cu. Wire from mcb
(a) with medium class Rigid PVC pipe and accessories erected flushed
on wall/ceiling complete (For AC)
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
56 metallic/white front plate , modules erected with necessary connections as Nos 1124.00 143.10
per site situation directed by Engineer In charge.
(1)One No. SP 6 Amp. - Cat.III
57 (2) One No 5 pin plug - Cat.III Nos 281.00 143.10
58 (5) Electronic hum Free steps EME Fan regulator - Cat.III Nos 390.00 377.10
59 (7) Blank Plate Single Nos 1124.00 24.00
60 (8) Computer RJ-45 socket Nos 20.00 152.10
Providing following type of Modular Type Accessories mounted with PVC /
metallic/Wooden box, single mounting base frame covered with textured /
61 metallic/white front plate , modules erected with necessary connections as Nos 15.00 171.10
per site situation directed by Engineer In charge.
(9) 16 Amp. SP one way switch - Cat.III
62 (10) 6/16Amp. Universal socket - Cat.III Nos 15.00 189.10
Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with
63 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of Mtr 3000.00 78.06
green colour for earth continuity of following size
(A) With medium class Rigid PVC pipe and accessories
(c) 3 wire 1.5 sq. mm
Supplying & erecting approved make low noise decorative exhaust fan
65 having square frame ABS body with inbuilt lowers & square frame. Nos 2.00 1,687.51
200mm with 1350 RPM Cat.II
SITC of CAT6 UTP 23AWG Solid: Per Meter
66 [Approved by Competent Authority i.e. not Below the rank of Executive NOS 400.00 43.05
Description Unit Quantity Rate Amount
CONFERENCE SOUND SYSTEM
Providing & erecting, programming, testing of chairman unit microphone
with flexible stem of 480 mm in length and light ring built in loud
speaker ,two head phone socket ,attractive design
,priority button for chairman microphone,built in volume control for
head phones,chime tone facility to precede chairman priority calls,
microphone on/off button, red indicates for microphone is active,
frequency response- 400Hz to 10kHz, nominal acoustic input -85 dB
SPL [[Approved by Competent Authority i.e. not Below the rank of
Executive Engineer ]
Providing & erecting, programming, testing of Delegate unit
microphone with flexible stem of 480 mm in length and light ring built
in loud speaker ,two head phone socket ,attractive design
,built in volume control for head phones,chime tone facility to
precede chairman priority calls,microphone on/off button,red indicates
for microphone is active,frequency response -400Hz to 10kHz,nominal
acoustic input -85 dB SPL [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Supplying & erecting dual channel amplifier ,power handling capacity
of 180 watt ,four micro phone inputs with independent level control
,built in FM tuner,with preset memories,USB drive & SD card for MP3
69 playback ,100v /telephone input with priority and VOX,frequency Ea 1.00 11,023.09
response-80 Hz to 18k Hz Philips / /distortion less than 1% @ rated
power up to 50 units [[Approved by Competent Authority i.e. not
Below the rank of Executive Engineer ]
Supplying and erecting wall mount speaker with rated power of
30 watt/power tapping 30/15/7.5 watt available,opening angle
degree H * 77 degree V ,sound pressure level 88 dB
,frequency response of 70Hz to 20KHz [[Approved by Competent Authority
i.e. not Below the rank
of Executive Engineer ]
SITC of 3LCD Lamp based projector having wxga (1280x800) or better
resolution with minimum white brightness of 3800 lumens and color
brightness of 3800 lumens. The projector should have minimum
1HDMI,1VGA input. Having contrast ratio of 15000:1 or more. the projector
should have auto vertical key stone correction of +/- 30 degree and
Manual Horizontal of +/-30 degree. the projector should have optical
lens, throw ratio 1.30-1.56:1. Zoom Factor of 1.2. Lens focus Manual
having focal length 16.9mm to
20.28mm. projector should have features like AV mute slide, quick corner
and split function and should support wireless functionality with inbuilt
wifi or wifi dongle. [Approved by Competent Authority i.e. not Below
the rank of Executive Engineer ]
Description Unit Quantity Rate Amount
SITC of 100 inch Self Lock MW (7 x 5) Instalock Slow Retraction
72 Screen, Aspect Ratio-4:3 [Approved by Competent Authority i.e. not Ea 1.00 3,776.44
Below the rank of Executive Engineer ]
SITC of 24 x 10/100/1000BASE-T PoE ports
4 x Gigabit RJ45/SFP Combo ports
Advanced L2 switching and security features L2+ Static Routing
73 Optional “standard mode” or “surveillance mode” management user Ea 1.00 31,708.80
interface 193 W PoE budget.
[Approved by Competent Authority i.e. not Below the rank of Executive
PA Sound System
74 SITC of Mixer amplifier, 60W [Approved by Competent Authority i.e. Ea 1.00 14,546.22
not Below the rank of Executive Engineer ]
Supplying and erecting Mixing Console having channels, Audio mixer
with Echo facility for live performance, Auditorium, and stadiums, having
the following features and facilities (approved by Competent Authority,
i.e., not below the rank of Executive Engineer): (a) input Channels:
Each channel has a separate 6.25mm balanced phone jack for mic and line
for balanced and unbalanced signals, (b) Individual gain control for
setting optimum level for minimum noise, (c) BASS, MID, and TREBLE
controls separately for each input channel, (d) ECHO control for each
channel, (e) PAN control for echo channel for left or right output, (f)
AUX Control to control the level of the channel in final mix to AUX
sound output, (g) Channel ON/OFF switch, (h) ECHO Section: ECHO, reverb,
and chorus effect can be added to all input channels by different settings
of Delay, Reverb, and Level control, (i) Tape section, (j) Aux. send and
75 return for sending pre-feeder output of channel for monitoring or Ea 1.00 18,208.24
adding a special effect unit, (k) Mono/Stereo output controls, (l) Master
faders to control over left and right output, (m) Headphone output
for monitoring purpose; Technical specifications: (a) Power Requirement:
AC 220-240V 50 Hz DC 24 Volts, (b) MIC Output Impedance/gain: 2 K
Ohms/62 dB, (c) Line Output Balance/42 dB – 20 K ohms, (d)
Impedance/Gain: 10 Kohms unbalance/42 dB, (e) Frequency Response:
30 Hz-20 KHz L/R Line Output (+0, -1 dB), (f) Equalization Bass: +/-
dB at 100Hz, Mid/Treble: 2 KHz/10 KHz, (g) Outputs: Line Output Low: -
10 dB/-2 dBM, Line Output High: 0 dBM/+17 dBM (775 mV/5.5 V), (h) S/N
ratio Line Output Level: >70 dB (0 dB, 0.775V), and the Console shall
be mounted on a standard rack, with channels of the following
numbers. (A) 14 Channel Audio Mixer with ECHO YAMAHA /SOUND
CRAFT/ MACKIE/ BEHRIGER or Eq.
Supplying, installing, testing, and commissioning (SITC) of a gooseneck
unidirectional condenser microphone with a flexible stem, phantom
powered by an amplifier, equipped with an on/off sliding switch with
76 priority contact, and supplied with a fixed 2-meter (78-inch) cable Ea 1.00 11,937.84
and a lockable DIN connector (approved by Competent Authority, i.e., not
below the rank of Executive
Description Unit Quantity Rate Amount
Supplying, installing, testing, and commissioning (SITC) of a 15W
cabinet loudspeaker in black, designed for high-fidelity music and speech
reproduction, with selectable 8-ohm, 70V, and 100V inputs, housed in a
77 compact yet robust ABS enclosure, supplied with an adjustable Ea 30.00 9,296.45
mounting bracket, and compliant with international installation and
safety regulations (approved by Competent Authority, i.e., not below
the rank of Executive Engineer).
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable
1.1 KV grade to be erected as directed of following size. 3 Core
Sqmm approved Make Only for outdoor fitting including cost of
78 mm PVC Pipe and GI Wire for Binding cable pole to pole for outdoor mtr 2250.00 135.06
from Amplifier to Speaker as per instructon given by engineer in
charge.Rate include all kind of
materials and labour work
Supplying, installing, testing, and commissioning (SITC) of a music
source with USB/SD/Tuner featuring MP3 playback from SD card and USB
inputs, an FM tuner with RDS, presets, and digital control, supporting
79 simultaneous operation of the SD/USB player and FM tuner, and Ea 1.00 59,752.28
equipped with separate outputs for the digital source and FM tuner
(approved by Competent Authority, i.e., not below the rank of Executive
Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to
0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS:
513/CRCA/aluminium pressure die cast powder coated and high
U.V. & corrosion resistance with diffuser housed in aluminium casted
body with company mark/name
80 160V to 270V,Power Factor more than 0.9, THD < 15 %, CCT 3000 K to Nos 2.00 164.26
Luminaire efficacy> 85 lumens/watt , LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below description
have shown ranges of Wattage capacity of LED fittings.The Engineer
incharge may select any wattage capacity between the ranges shown.)
(A) Tube Light with integral driver
i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet CAT III
81 (iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet CAT III Nos 6.00 293.26
82 (iv) 22-24 Watts, Surge - 2KV,IP-20, conventional 4 feet CAT III Nos 108.00 370.26
83 (v) 36-40 Watts, Surge-2 KV, IP-20, conventional 4 feet CAT III Nos 231.00 530.26
Description Unit Quantity Rate Amount
LED Light :- Indoor Fixture
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V, Power Factor more than 0.95, THD < 10 %, CCT
84 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 Nos 68.00 5,545.28
lumens/watt . LED driver efficiency > 85 %.( fittings required LM79
& LM-80 certificates)(NOTE: Below description have shown ranges of
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
B) Flood Light (IP-65), Surge protection -4KV integral and , Light must have
440 VAC line supply with over-voltage protection.
(ii) above 48 to 60 Watts CAT III
1200mm sweep ceiling fan, capacitor type, Providing & erecting
Approved make Ceiling Fan with double ball bearing ISI mark with
Condenser 230 volt A.C.50 Hz 1200 mm sweep complete having 3 blades
aluminium body and blade sets having ornamental design shanks
canopy erected with earthing. [ Make shall be approved by Engineer in
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe
86 down rod erected duly painted for fan complete with proper insulation mtr 585.00 107.13
without leakage and earthing.
Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 3 Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and Polycarbonate optics/
lenses, with toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT
3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy>
87 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM- Nos. 8.00 4,772.85
80 certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of finish cast aluminum spigot
and spun aluminum canopy fixed with opal polycarbonate, pipe
arrangement for vertical mounting driver and accessories wired upto
terminal block. IP
(i)30- 40W - Cat-lll
Description Unit Quantity Rate Amount
Supplying and erecting approved make Octagonal pole made from HR
sheet steel. The pole should be made as per IS. and shall be coated with
hot dip galvanizing as per IS 2629/2633/4759, suitable suspend local wind
speed with integral Junction box consist of terminal plate of min 6mm
Hylam sheet, standard profile 35mmX7.5mm Din-Rail for MCB Mounting,
88 stud type terminal and arrangement for cable termination to be Nos 8.00 4,198.80
erected With Suitable foundation (Included) as per details given by
manufacturer considering site requirement.
(A) 3 Mtr. Long 70 mm Top X 130 mm bottom dia.3 mm thickness with
200mmX200mmX12mm base plate, 4-M16 Bolts and 450mm long J-
Bolt.Approx weight 29 kg
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity
KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark
single pole 6A to 25A Cat.III
Providing and erecting Inverter based approved make split air-
conditioning unit consisting of condensing unit with variable speed
fan motor, inverter type hermetically sealed rotary compressor with
accessories etc. duly connected separately erected evaporating unit and
blower motor with its accessories by means of extra supplied proper
insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco
Friendly green gas charging and 15A plug top & Remote Control & MS
Stand) with necessary core cutting.
2)For 4/5 Star Rating of current year
(C) for 1.7 to 2 ton capacity
91 (A) for 0.8 to 1.0 ton capacity- Premium Cat. Nos 3.00 36,849.12
Providing and erecting water cooler having storage capacity 80Ltr. &
cooling capacity 40 Ltr.per hour @ an ambient temp of 45˚ C. The
outlet temp. of the water should drop by 15˚ C within a hour, The
92 water cooler should be comprising of hermetically sealed compressor, Nos 1.00 40,935.55
fan motor, condensing unit, water tank surrounded by evaporating coil,
thermostats, relay etc. complete with necessary inlet & outlet connection.
The body of water cooler will be made from Stainless Steel. ◦
Supplying & erecting reverse osmosis (RO) water purification system with
M.S. powder coated pedestal frame, prefilter housing carbon filter suitable
buster DC pump, auto low & high pressure switches with following size of
LPH capacity & erected as directed
[D] 100 LPH with 1 phase / 3 phase Raw water pump of 500LPH @
93 2.5kg/cm2 - (1N0 - Kirloskar Nos 1.00 64,416.48
/CRI/Lubi), Dual media filter 10"x54" - (1 No), Micron cartridge filter
20" x 2.5" ( 1No), High pressure pump 500LPH @ 10kg/cm2 - (1No -
Shimge /CRI /Lubi), RO Membrane housing with RO membrane of 40*40
- (1No), RO pressure tube 4" x 1E - ( 1No), 0 - 1200LPH Rotameter -(2
Nos), with Recovery Rate 50%.
Description Unit Quantity Rate Amount
SAFETY ACCESSORIES
SITC of following safety accessories complete with necessary
fixing brackets, other accessories and tools etc. as required to
94 complete the job. Nos 10.00 8,586.26
Supply & Erecting carbon dioxide (CO2) fire extinguisher of 6.5kg
capacity with necessary clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete.
Supplying FIRE bucket round bottom of 9 litres capacity made out of
24 gauge G.I. sheet with extra handle at bottom duly painted white inside
and Red out side with FIRE mark, filled with dry sand and kept on existing
stand provided or hung on wall hook.
Supplying and erecting floor mounting stand for keeping four nos. of FIRE
buckets comprising 1500 mm in length, 900 mm height frame made out
96 of 30mm X30 mm X 4 mm angle iron with cross supports for legs, welded Nos 2.00 933.43
with 4 hooks and duly painted with one coat of red lead and two
coats of approved enamelled silver paint.
Supplying stand first AID box with anticeptic cream, medicine for use on
wounds due burn, crepe bandage, guage bandage, medicated ready to use
97 bandage (Band-aid) adhesive tape for medicinal user, scissors, anticeptic Nos. 4.00 297.00
solution (Savlon or similar) etc. (All above contents shall be of standard
Providing and fixing printed instruction (First Aid) Chart both in English
and Gujarati and duly framed with front glasses, for treatment of person
suffering from electric shock with minimum 50" diagonally size. (1no. For
Supply and laying of 4 mm thickness, Rubber Matting as per as per
LT & APFC etc. Panels)
Providing , erecting , fabricating the M.S. structure as per
requirement on site incorporating proper size of M.S.
100 angles,square,round, flats, bars, channels, sections complete with kg 500.00 77.20
cutting, welding, grinding & finishing duly painted with one coat of red
oxide with erection on site as per direction of engineer in charge
with necessary grouting, cementing, plastering & finishing complete.
Description Unit Quantity Rate Amount
Supply, installation, testing, and commissioning of a high-pressure
misting system for a cattle farm to maintain optimal temperature
and humidity levels, ensuring animal comfort and productivity.
The system shall comprise stainless steel or brass misting nozzles capable
of producing ultra-fine droplets (10–50 microns) for efficient cooling, along
with an industrial-grade, corrosion-resistant high-pressure pump
operating at 70–100 bar. The piping network shall consist of UV-
resistant, high-pressure-rated PE or stainless steel tubing with leak-proof
connectors. The system shall be equipped with an automated control unit,
either timer-based or sensor-based, to optimize water and energy usage.
An inline water filtration system shall be provided to prevent nozzle
clogging and ensure clean misting. The installation shall be carried out
with durable, corrosion-resistant supports and fixtures, ensuring uniform
coverage across the designated cattle housing area. Upon completion, the
system shall undergo thorough testing and commissioning to verify
proper mist dispersion and operational efficiency. The complete misting
system, including all components, installation, and commissioning, shall
be measured as a single set. with all required accessories and as per
instruction of engineer incharge.
Total cost (in Rs.) =
Construction of Various Shed
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5m depth including sorting out and
1 stacking of useful materials and disposing off the excavated stuff upto Cu.M. 2167.50 268.21
50Meter lead. (C) Hard Murrum
Box Cutting the road surface to proper slope and camber for making a base
2 for road work including removing the excavated stuff and depositing on Cu.M. 1100.35 109.05
the road side slope as directed up to 50 Mt.Lead
Providing and laying cement concrete 1:3:6 (1-Cement : 3-coarse sand : 6-
3 hand broken stone aggregates 40mm nominal size) and curing complete Cu.M. 903.56 2,968.91
excluding cost of formwork in (A) Foundation and Plinth
Providing and laying controlled cement concrete M.200 and curing
4 complete including the cost of formwork and including the cost of Cu.M. 930.52 4,338.96
reinforcement for reinforced concrete work in (A) Foundation & Footing
Providing and laying controlled cement concrete M.200 and curing
5 complete including the cost of formwork and including the cost of Cu.M. 38.43 8,730.44
reinforcement for reinforced concrete work in ( D ) Column
Providing and laying controlled cement concrete M.200 and curing
6 complete including the cost of formwork and including the cost of Cu.M. 241.05 6,696.30
reinforcement for reinforced concrete work in (C) Ground Beam
Filling available excavated earth (excluding rock) in trenches plinth, sides of
foundations etc. in layers not exceeding 20cm. In depth consolidating each
disposited layer by
ramming and watering.
Carring out plinth treatment to post construction / existing structure by
spraying chemical solution for termite control treatment including labour
and material consistment with I.S.I specification. Using Chlordene and
8 Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one Smt. 4227.42 86.82
percent is recommended i.e one litre 20 EC chemical emulsion with 19 liter
give 1 % concrentration inclusive of one litre chemical emulsion appication
at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S
Filling in plinth with sand under floors including watering ramming,
consolidating and dressing complete
Brickwork using common burnt clay building bricks having crushing
strength not less than 35kg./Sq.Cm. in Foundation and Plinth in Cement
Mortar 1:6 (1-Cement : 6 -fine sand)
(B) Conventional
Half brick thick honey- comb brick work with common burnt clay building
bricks having crushing strength not less than 35 Kg/Sq.Cm.
(ii) In Cement Mortar 1:5 ( 1Cement :
5 - coarse sand)
Providing TMT Bar FE500D Reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
Description Unit Quantity Rate Amount
20mm thick sand faced cement plaster on walls upto height 10metres
above ground level consisting of 12mm thick backing coat of C.M. 1:3 (1-
cement : 3-sand) and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-
sand) etc. complete.
Providing and fixing M.S. grills of required pattern to wooden frames of
windows etc. with M.S. flats at required spacings and frame alround,
square or round bars with round headed bolts and nuts or by screws
(A) Plain Grill.
Steel work, welded in built up sections framed work including cutting,
hoisting, fixing in position and applying a priming coat of red lead paint.
(A)In beams and joists, channels angles Tees, flats, with connecting plates
or angle cleats as in main and cross beams. Hip and jack rafters, purlins
conneted to common
rafters and the like
Providing and fixing tiles roofing with manglore tiles including teak reepers
of sizes 50mm x 25mm etc complete as directed by Engineer in charge
Finishing wall with water proofing cement paint of on wall surfaces (Two
coats) to give an approved brand and manufacture and of required shape
even shade after thoroughly brushing the surface to remove all dirt and
remains of loose powered materials.
Wall painting (two coats) with plastic emulsion paint ofapproved brand
and manufacture on undecorated wallsurface to give an even shade
including throughly brushing the surface free from mortar droppings and
other foreign matter and sand papered smooth.
Applying priming coat over new steel and other metel surface after and
including preparing the surface by throughly cleaning, oil,grease, dirt and
other foreign matter and scoured with brushes fine steel wood, scrapers
and sand paper with ready mixed priming paint brushing red lead.
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brushing, interior to give an even shade
20 including cleaning the surface an even shade including cleanicn the surface Sqmt 123083.92 92.17
of all dirt, dust and other foreign
Total cost (in Rs.) =
Cow Urine Collection
Description Unit Quantity Rate Amount
Excavation for foundation upto 1.5 m depth including sorting out and
stacking of useful materials and disposing off the excavated stuff upto
(A) Loose or soft soil
Excavation for foundation upto 1.5 m depth including sorting out and
stacking of useful materials and disposing off the excavated stuff upto
lead.(B) Dense or Hard soil
Providing and laying cement concrete 1:3:6 (1- Cement : 3- coarse
3 sand : 6- hand broken stone aggregates 40 mmnominal size) and curing cum 35.00 2,968.91
complete excluding cost of formwork in (A) Foundation and Plinth
C.C. M-20 Nominal Mix (with w.p.chemical)
Providing and cast in situ C.C. in grade M-20 (approx. corresp. to prop.
1:1.5:3)(proportions as per mix design or as per table9 of IS456
in masses by weigh batching) using quartzite trap metal of size 12 mm to
20 mm and or 6 mm to 12 mm including scaffolding centering form
work, needle vibrated consolidation, curing and hydraulic testing
etc. complete (excluding cost of reinforcement) with centering and
shuttering/deshuttering etc. complete up to 6 meter height/depth from
Av. G.L. for all structures with waater proofing compound. Box portion
bottom slab/floor slab/slab with shuttering
5 Box portion Vertical Wall cum 92.06 8,236.30
Providing TMT Bar FE 500D reinforcement for R.C.C. work including
bending, binding and placing in position complete upto floor two level
Filling availabale excavated earth (excluding rock) in trenches plinth, sides
7 of foundations etc. in layers not exceeding 20 cm in depth consolidating cum 322.00 136.92
each depo sited layer by ramming and watering)
Precast Cover for Box Drain (Width-0.6 Mtr)
Providing, Supplying and Fixing RCC M-250 precast cover of 500 mm (L) x
600 mm (W) x 90 mm thick on existing Strom Water drain including cost of
reinforcement steel as per approved design and drawing. The work is
including all kind of labour and materials to completed the work as per
approved design and drawing & instruction of Engineer in charge.
Providing 15 mm. thick cement plaster in single coat on Rough(similar) side
9 of single or half Brickwalls for interior plastering upto floor two level and Sqm 163.00 165.31
finished even and smooth in : cement mortar 1:4 (1 cement : 4 sand)
Total cost (in Rs.) =
Water Distribution Network & Connection at Each Pit
Description Unit Quantity Rate Amount
Providing and supplying in standard length ISI mark rigid unplasticised
PVC pipes suitable for potable water with ring fit joint including cost of
rings, as per IS specification no. 4985/1988 including all local and
1 central taxes, transportation, freight charges, octroi, inspection charges, Rmt. 400.00 86.00
loading, unloading, conveyance to the departmental stores and including
cost of jointing meterial etc. complete. PVC Pipes Test Pressure 8 Kg/cm2
63 mm Dia. Pipe
2 75 mm Dia. Pipe Rmt. 92.00 123.00
3 90 mm Dia. Pipe Rmt. 35.00 173.00
Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846
(Latest Edition) of following class and diameter including all taxes,
insurance, transportation, freight charges, octroi, inspection charges,
4 loading, unloading, conveyance to departmental stores, stacking etc. Nos. 4.00 2,366.00
complete. P.N.1.0 with hand wheel/cap operated (PD type short
body) For Sluice Valve
Excavation for pipe line trenches for water supply, sewerage line,
manhole etc. all with shoring and struting if required as per required
gradient and line including safety provisions using site rails and stacking
7 excavated stuff including up to all required lead cleaning the site etc. Cum 214.14 102.35
complete for all lifts and
strata as specified. 0.0 to 1.5 mt depth.
a) In all sorts of soil and soft murrum
8 b) In hard murrum, boulders incl. macadam road Cum 171.31 155.25
c) In soft rock and/or masonary in CM or LM or Lime
d) In hard rock and/or in C.C. 1:2:4 or R.C.C. with blasting and
chiselling or by chiselling
Lowering, laying, fixing and jointing PVC/uPVC/cPVC pipes and specials
of following class and diameter including cost of conveyance from stores
11 to site of works including cost of labour, material, cement solvent, Rmt. 392.00 13.80
giving satisfactory hydraulic testing as per ISI code.
63 mm Dia. Pipe
12 75 mm Dia. Pipe Rmt. 90.00 17.25
13 90 mm Dia. Pipe Rmt. 34.00 19.55
Lowering, laying and jointing in position following C. I. / D/F Reflux
valves, Butterfly valves, Sluice valves including cost of all labour, jointing
material, including nut bolts and giving satisfactory hydraulic testing,
etc. complete. P.N.1.0 with hand wheel/cap operated (PD type short body).
for Sluice Valve
For a 65 mm dia.
Description Unit Quantity Rate Amount
Construction of valves chambers in brick or bela stone masonry,
locally available in C. M. 1:6. Foundation concrete 150 mm thick in C.
C. 1:4:8 of trap metal size 25 mm to 40 mm thick, inside cement
plaster in C. M. 1:3 and cement pointing outside in C. M. 1:3 and top
cover of precast RCC slab 100 mm thick (with key hole in two parts,
17 each with handles or MS Bar etc. complete as given size) Upto 1 Mt. Nos. 6.00 8,898.70
depth from G. L. to pipe invert level incl. complete civil works but excl. cost
of excavation and refilling, with cast in situ RCC slab in one single piece
with fixing of CI-MH Frame and cover (excl. cost of CI-MH Frame and cover)
with 23 mm thick brick masonry wall in C.M.1:6 a 0.9m L X 0.9m B X 1.0m
18 For 0.20 Mtr. Extra Depth Rmt 1.20 5,150.85
Refilling the pipeline trenches including ramming, watering,
19 consolidation, disposal of surplus stuff as directed within a radius of 3 Cum 426.44 25.30
Connection at Each Pit
Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe
(SCH-40) for cold water including fittings as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of clamp at every two
metre C/C or shall be concealed as directed including necessary fittings etc.
including testing of pipe and joints and fixing the same with adhesive
solvent, including cost of all materials.
SITC of Sound System
Description Unit Quantity Rate Amount
SITC of Mixer amplifier, 60W
[Approved by Competent Authority i.e. not Below the rank of Executive Engineer ]
Supplying and erecting Mixing Console having channels, Audio mixer with Echo facility
for live performance, Auditorium, and stadiums, having the following features and
facilities (approved by Competent Authority, i.e., not below the rank of Executive
Engineer): (a) input Channels: Each channel has a separate 6.25mm balanced phone
jack for mic and line for balanced and unbalanced signals, (b) Individual gain control for
setting optimum level for minimum noise, (c) BASS, MID, and TREBLE controls
separately for each input channel, (d) ECHO control for each channel, (e) PAN control
for echo channel for left or right output, (f) AUX Control to control the level of the
channel in final mix to AUX sound output, (g) Channel ON/OFF switch, (h) ECHO Section:
ECHO, reverb, and chorus effect can be added to all input channels by different settings
of Delay, Reverb, and Level control, (i) Tape section, (j) Aux. send and return for sending
pre-feeder output of channel for monitoring or adding a special effect unit, (k)
Mono/Stereo output controls, (l) Master faders to control over left and right output,
(m) Headphone output for monitoring purpose; Technical specifications: (a) Power
Requirement: AC 220-240V 50 Hz DC 24 Volts, (b) MIC Output Impedance/gain: 2 K
Ohms/62 dB, (c) Line Output Balance/42 dB – 20 K ohms, (d) Impedance/Gain:
Kohms unbalance/42 dB, (e) Frequency Response: 30 Hz-20 KHz L/R Line Output (+0, -1
dB), (f) Equalization Bass: +/- 12 dB at 100Hz, Mid/Treble: 2 KHz/10 KHz, (g) Outputs:
Line Output Low: -10 dB/-2 dBM, Line Output High: 0 dBM/+17 dBM (775 mV/5.5 V), (h)
S/N ratio Line Output Level: >70 dB (0 dB, 0.775V), and the Console shall be mounted
on a standard rack, with channels of the following numbers. (A) 14 Channel Audio
Mixer with ECHO YAMAHA /SOUND CRAFT/ MACKIE/ BEHRIGER or Eq.
Supplying, installing, testing, and commissioning (SITC) of a gooseneck unidirectional
condenser microphone with a flexible stem, phantom powered by an amplifier,
3 equipped with an on/off sliding switch with priority contact, and supplied with a fixed 2- Each 1.00 11,937.84
meter (78-inch) cable and a lockable DIN connector (approved by Competent Authority,
i.e., not below the rank of Executive Engineer).
Supplying, installing, testing, and commissioning (SITC) of a 15W cabinet loudspeaker in
black, designed for high-fidelity music and speech reproduction, with selectable 8-ohm,
70V, and 100V inputs, housed in a compact yet robust ABS enclosure, supplied with an
adjustable mounting bracket, and compliant with international installation and safety
regulations (approved by Competent Authority, i.e., not below the rank of Executive
Supplying & erecting XLPE(IS:7098)(I)-88 ISI unarmoured copper cable 1.1 KV grade to
be erected as directed of following size. 3 Core 2.5 Sqmm approved Make Only for
5 outdoor fitting including cost of 25 mm PVC Pipe and GI Wire for Binding cable pole to Rmt 2550.00 135.06
pole for outdoor from Amplifier to Speaker as per instructon given by engineer in
charge.Rate include all kind of materials and labour work
Description Unit Quantity Rate Amount
Supplying, installing, testing, and commissioning (SITC) of a music source with
USB/SD/Tuner featuring MP3 playback from SD card and USB inputs, an FM tuner with
RDS, presets, and digital control, supporting simultaneous operation of the SD/USB
player and FM tuner, and equipped with separate outputs for the digital source and FM
tuner (approved by Competent Authority, i.e., not below the rank of Executive
Total cost (in Rs.) =
SITC of CCTV Camera System
Description Unit Quantity Rate Amount
CCTV Providing and instaling IP Camera 1/2.8” Progressive Scan CMOS
megapixel resolution Digital WDR, 3D DNR 50 meters IR range 12V DC±10%,
ICR *power supply not included, Wall mount bracket is included 4mm lens,
PoE Camera. 2 MP IP Network Camera, 1/2.8″HD Progressive Scan CMOS
Image Sensors, 1920×1080 Resolution, DWDR (Digital Video Dynamic
Range) Up to 50 Mtr IR distance, POE Optional 3D DNR, Mobile Monitoring .
1 Image Sensor: 1 / 2.8 “ progressive scan CMOS Min Illumination: 0.01 Lux , 0 Nos. 20.00 8,325.00
Lux with IR Shutter Speed: 1/3 s to 1/1000,000 s , Supports slow shutter.
mm @ ( F 2.0) Horizontal Field of View 83.6 Degree, 6 mm Lens@ (F 2.0)
Horizontal Field of View 55 Degree, 8mm@ (F 2.0 ) Horizontal Field of View
38.5 Degree, 12mm@ (F 2.0 ) Horizontal Field of View 24.6 Degree,
Optional. ( Including cost of Bracket.) CCTV including cost of connectivity
OFC to CCTV Wire with all switch, wire,and assecories
IP 67 Junction Box (Metalic) : Providing & erecting approved make street
light / wall mounting metalicjunction box compression moulded from DMC
(thermoset plastic) vertical sliding cover having locking with square head
stud loop in / loop out in built terminal suitable for four core cable,
waterproof of I.P. 67 protected with clamp or bolt nut & earth bolt of
following size.[B] 250mm x 194mm x 99 mm
Providing & laying approved make Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth in existing trench for laying
of cable. below ground / road surface for enclosing cable 63 mm Outer dia
Providing & Laying Opticle Fiber :with 4 core high tensile strength and
flexibility in compact cable sizes. At the same time, it provides excellent
optical transmission and physical performance, Excellent quality control is
achieved through intense in-house quality check and stringent audit
01.It is designed, manufactured and tested according to international
The optical fiber is made of high pure silica and germanium doped silica. UV
curable acrylate material
is applied over fiber cladding as optical fiber primary protective coating.
Description Unit Quantity Rate Amount
9U-NVR Reck : Usability- Network Switches/Routers/Firewall/
DVR/NVR/Audio- Visual Equipment/Low Depth Servers Front Door- Glass
Door With Key LockRear door- Not Available due to Wall Mount Provision
Rear door available For Floor Stand Rack,Side Panels- Fixed Welded/bolted
with Top/Base Frame,Cable Entry Cut- Top/ Bottom ,2 Pair Heavy Duty
(1.5/2.0mm) Vertical Mounting Rail.,Cooling Option- fan Provision mounted
on Top Panel,Load Bearing Capacity up to 25 -30 KG,Construction-
Dismantle/Welded Construction Overall 1.0mm Thick (20 gauge), Load
Bearing angles are 1.6 MM,Power Distribution Unit- 4 Socket 5 & 15 AMP
64 CH - NVR : Dual-OS design to ensure high reliability of system running,Up
to 64-ch 12 MP IP cameras can be connected,H.265+ compression
effectively reduces the storage space by up to 75%,Full channel recording at
up to 12MP resolution,HDMI1/VGA1 and HDMI2/VGA2 outputs
provided,HDMI1 Video output at up to 4K (3840 × 2160) resolution,Up to
SATA interfaces and 1 eSATA interface for HDD connection,10TB capacity
for each HDD,16-ch synchronous playback at up to 1080p resolutionTwo-
way audio-1-ch, RCA (2.0 Vp-p, 1 k Ω),Outgoing bandwidth 256 Mbps, or
200 Mbps (when RAID is enabled),Remote connection 128, CVBS output
(Optional) 1-ch, BNC (1.0 Vp-p, 75 Ω), resolution: PAL: 704 × 576, NTSC:
× 480,Capability 2-ch @ 12 MP (20fps) / 4-ch @ 8 MP (25fps) / 8-ch @ 4MP
(30fps) / 16-ch @ 1080p (30fps),Network protocols TCP/IP, DHCP, DNS,
DDNS, NTP, SADP, SMTP, NFS, iSCSI,
UPnP™, HTTPSSATA 8 SATA interfaces for 8HDDs,eSATA 1 eSATA
interface,Capacity Up to 10TB capacity for each HDD,Array type RAID0,
RAID1, RAID5, RAID6, RAID10
HDD 6 TB : Engineered specifically for surveillance security systems,
Supports up to 180 TB per year work load rate ,Prioritized write-operations
for maximized surveillance performance Support for more than eight bays,
Tuned for write-intensive, low bit-rate, high stream-count applications
typical to most surveillance applications TLER and ATA streaming support
Tarnish-resistant components
7 Disk Speed: 5400 rpm, 7200 rpm , Compatibility: storage is built to handle Nos. 1.00 24,200.00
up to 64 cameras per drive and is designed for 24/7, always on, high-
definition surveillance security systems with more than eight bays.Capacity
• Support for up to 64 cameras per drive
• AllFrameTM technology
• MTBF of up to 1.5 million hours
Description Unit Quantity Rate Amount
LED - 32 Inch :80 cm (32 inch) HD LED TV Details.Television Type Flat Panel
Samsung or equilant approved make
32 Inches, Type LED , Backlight Technology
Ratio 16:9 Dynamic Contrast Ratio
8 Mega Contrast Refresh Rate Nos. 1.00 20,000.00
60 Hz Vertical Viewing Angle
178 Degree Horizontal Viewing Angle
178 Degree Picture Processor
HyperReal Engine Color Enhancer
Wide Color Enhancer (Plus)
Wire Less Mouse : Wireless Mouse features compact design, convenient
scroll wheel, and a wireless USB receiver. The built-in USB receiver is
plugged into your USB port of your device and enables you to operate the
device even from a fair distance seamlessly.
Working Principle: 2.4 GHz Radio Frequency
DPI Button: 600/1200/1600 DPI adjustable
9 Buttons: Left, Right, Wheel and DPI Nos. 1.00 800.00
Receiver: USB dongle
USB Receiver: Nano
Working Range: Max 10 Meters
Wheel 1 Scrolling Wheel
Power Consumption: 3V DC 15 mA
Switch/MTBF: Left/Right Button (100±gf/upto 1 kk times) and Middle
Button (120±gf/upto 1 kk times))
Installation of Camera including all kind of labour work required to fix
camera on pole or wall etc as per requirement
Total cost (in Rs.) =
Provision of Sculpture, Statue, Benches & Various artifects Speciments
Description Unit Quantity Rate Amount
Providing, fabricating, and installing a decorative Shree Krushna Statue at
the entry gate of the layout, artistically crafted with intricate detailing and
fine finish. The statue shall have a height ranging from 2.0 to 2.5 meters
and width (breadth) between 0.6 to 0.8 meters, proportionate in scale and
aesthetically designed as per approved 3D render or conceptual drawings.
Material: Made using Fiber Reinforced Plastic (FRP) or natural/mixed stone,
including Dhrangadhra stone or equivalent, as per architect/engineer’s
approval. The statue may use a combination of materials to enhance
strength and aesthetics.
Providing, fabricating, and installing a life-sized Cow Statue with
approximate height between 1.2 to 1.5 meters, length (head to tail) from
2.4 to 2.7 meters, and width (across hips) from 0.6 to 0.9 meters,
aesthetically modeled with realistic posture and fine detailing. The statue
should be crafted as per the approved design/drawing provided by the
2 architect or landscape consultant. Nos. 2.00 46,000.00
Material: Made using Fiber Reinforced Plastic (FRP) or cement-based
material, or a combination thereof, ensuring long-term outdoor durability
and resistance to weathering. Finished with high-quality, non-fading paints
and a protective topcoat.
Providing, fabricating, and installing a composite sculpture unit consisting
of Shree Krishna statue, cows, and other traditional elements, artistically
integrated within a 4.0 m x 4.0 m area (total footprint). The entire
composition shall be designed as a single cohesive unit representing a rural
or mythological scene, as per the approved artistic rendering or reference
3 image provided by the architect. Nos. 1.00 6,90,000.00
Material: Crafted from high-strength Fiber Reinforced Plastic (FRP) and/or
cement-based sculpting material, or a combination, suitable for outdoor
conditions. All components shall be finely detailed, painted with
UV/weather-resistant paint, and finished with a protective topcoat.
Providing and fixing carved decorative work for the Entrance Gate,
including all carving components such as carved panels, cladding sheets,
motifs, and ornamental details, designed as per approved architectural
drawings. The work involves surface cladding and detailing to enhance the
cultural/aesthetic appearance of the gate.
Material: Made from a combination of stone, GRC (Glass Reinforced
Concrete), cement-based components, and decorative adhesive carving
sheets or equivalent mixed media. All materials should be of premium
quality, weather-resistant, and suitable for exterior use.
Description Unit Quantity Rate Amount
Providing, fabricating, and installing a high-quality RCC Bench with backrest
constructed using M-30 grade concrete with 3% red pigment, reinforced
with 10 mm dia TMT bars (4 nos.) and 4 mm dia stirrups @ 150 mm c/c,
seat and backrest planks sized 1500 mm x 200 mm x 50 mm and 1500 mm x
100 mm x 50 mm respectively, connected using 12 mm x 65 mm galvanized
steel countersunk bolts and 165 mm x 8 mm carriage bolts with EVA
washers, finished with acrylic paint as per IS: 15489/latest, and installed
with a 3-year warranty.
Total cost (in Rs.) =
Design, supply, install and commission a 1 Ton Double Chamber Animal Incinerator System with pollution control and CPCB compliance on turnkey basis.
Description Unit Quantity Rate Amount
Double Chamber Animal Incinerator System (1 Ton Capacity)
Design, detailed engineering, manufacturing, supply, transportation, unloading, erection, testing and commissioning of a fully automatic PLC-
controlled Double Chamber Animal Incinerator System of 1000 kg per batch capacity suitable for disposal of cow/large animal carcasses,
comprising heavy-duty fabricated Primary Combustion Chamber constructed from minimum 8 mm thick MS side walls and 10 mm thick
bottom plate conforming to IS 2062 Grade E250, designed to operate at 600°C–800°C and fully refractory lined with multi-layer lining (high
alumina bricks conforming to IS 6/IS 8, insulating fire bricks as per IS 2042 and ceramic fiber blanket insulation) with total thickness 230–300
mm, along with Secondary Combustion Chamber (Afterburner) designed to maintain 1100°C–1200°C and minimum 2 seconds gas retention
time for complete oxidation of flue gases and VOCs; complete with six (6) fully automatic LPG/PNG/Diesel fired burners (four in primary and
two in secondary chamber) with ignition system, UV/IR flame sensor, double solenoid valves, gas train conforming to IS 6044, flame failure
protection and PID-based temperature control through PLC; centrifugal primary air blower and Induced Draft (ID) fan conforming to IS
with TEFC motors as per IS 325 to maintain adequate combustion air supply and negative pressure; high efficiency Vertical Packed Bed Wet
Scrubber (MS/FRP construction) with recirculation pump conforming to IS 1520, spray system, mist eliminator and minimum 95% particulate
removal efficiency; MS Chimney/Stack of minimum 9–12 m height or as per CPCB norms designed as per IS 6533 and wind load provisions of
1 IS 875 (Part 3) including ladder, sampling port, aviation lamp and earthing as per IS 3043; removable ash tray and ash handling arrangement Nos. 1.00 31,50,000.00
ensuring ash generation less than 5% of input weight; structural steel platforms, ladders and supports designed as per IS 800 with epoxy
painted finish and GI gratings; PLC-based LT control panel (IP55) conforming to IS 8623 with HMI, temperature monitoring, burner interlocks,
emergency stop, MCCB protection, surge protection, complete FRLS copper cabling as per IS 732/IS 7098 and double earthing as per IS 3043;
complete RCC foundations for incinerator body (minimum M25), chimney base (minimum M30), scrubber, ID fan and blower including PCC
bed, anchor bolts, grouting and finishing as per IS 456 and IS 1786; ash pit, drainage channel and neutralization pit for scrubber discharge;
including all mechanical, electrical, refractory, insulation, civil works, safety systems, installation, alignment, refractory dry-out, testing,
commissioning, one full load performance trial, emission compliance as per CPCB guidelines, submission of GA drawings, P&ID, electrical
schematic, foundation drawings, structural and chimney design calculations, emission guarantee certificate, material test certificates, O&M
manual and performance test report, complete in all respects as directed by Engineer-in-Charge.
Total cost (in Rs.) =
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
03_SBD_GUDC_Extent_of_Works_Cattel_Shed.pdf
04_Gen_Tech_Spec_Civil_R_and_B_Cattle_Shed.pdf
05_General_Tech_Spec_Electrical_Cattle_Shed.pdf
06_Item_Tech_Spec_Cattle_Shed.pdf
07_SBD_GUDC_Works_Price_Bid_Cattle_Shed.pdf
09_SBD_GUDC_Works_Bid_Drawings_Cattel_Shed.pdf
12_GR_DOC_2.pdf
11_GR_DOC_1.pdf
08_Schedule-B_Aspirational_Cattle_Shed.pdf
17_DMO_2941_01-Apr-2026_744.pdf
02_Vol-I-B_SBD_GUDC_Works_GCC_Cattle_Shed_01-06-2026.pdf
01_SBD_GUDC_Works_Tech_Bid_Cattle_Shed_01-06-2026.pdf
Download all tender documents and submit your bid