Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
23 Jun 2021, 2:00 pmClosed
Executive Engineer Mech. Div Kgl
Office of the Executive Engineer Mech. Div Kgl
Design, Supply, Installation, Testing and Commissioning of multi stage centrifugal pump coupled to 3-phase squirrel cage induction motor along with its allied equipments and installation of rising main for lift water supply/irrigation scheme Pishu Za
2021_PWD_2965_2
MDK/E-NIT/01 of 2021-22
Open Tender
Pumps/Motors
Turn-key
90 days
Pishu Zanskar
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Executive Engineer Mech. Div Kgl
₹90,000
Office of the Executive Engineer Mech. Div Kgl
29 Jun 2021
3 Jun 2021
23 Jun 2021
3 Jun 2021
23 Jun 2021
3 Jun 2021
18 Jun 2021
Amount
Design, Supply, installation, testing , and commissioning of Multistage Horizontal Centrifugal Pump with Bronze Impeller, Cast Iron/S.G Iron casing/WCB, mechanical seal bearing lubrication oil, Coupled to Energy Efficient Squirrel cage induction Motor resting on a M.S common base frame properly aligned. The motor shall be suitable for three phase 415 V ± 10%, 50Hz supply. The job includes parallel combination of two pump sets fitted with two Cast Iron NRVs, Two Cast Iron Sluice valves, Long radius 90® bends 03 Nos, common pressure header with Flanges, Cork sheet Gaskets, Nuts Bolts with washers, provision for 25mm priming facility using 25mm heavy duty ball valves 02 NOs, 25mm (ERW) M.s. Pipe etc with each pump and M.S. Suction pipe of 4.6mm thick of (02 length) / 12 meter with Flanges, long radius bend 02 NOs, foot valves 02 NOs with strainer , clips and clamps, nipples, flanges etc. The size of the NRVs Sluice Valves and suction pipe shall be in accordance with the size of the pump i.e. (Suction/ Delivery). I) capacity of Pump =10 LPS II) Total Head = 130 mtrs III) Efficiency > 70% IV) Driving Motor Rating at 415V± 10%, 50Hz = 40 HP V) Speed = 1400-1450 RPM VI) Insulation =F-class
Control Panel with one incomer / two out goings for two pump sets in parallel operation. (One running and the other standby and vice versa) with control cubical for lighting (10 Amp / 220 V, heating 30 Amp/ 220V) miscellaneous 15 Amp/420V . Soft starter/ star-delta starter for each pump sets. Design, Fabrication, Assembling, Wiring , Installation, Testing and Commissioning fixed type, floor mounted, cubical design motor control centre fabricated out of 2mm/14 SWG CRCA thick sheet duly painted, suitable for indoor use, internally wired complete with Aluminum bus bar covered with PVC heat shrinkable sleeves, cloud coded. The panel shall be complete with all protections in-build (Over load/PTC/Line fault /Voltage imbalance/Phase reversal/ Under voltage/ Over temperature/Open Gate/ Excessive Starts per Hr, Single phasing), Innovative starting solutions:- ( soft start/soft stop/ current limit/ full voltage/kick start/presets low speed/ linear speed start and stop/dual ramp), Main incoming MDO ACB with short circuit release including earth fault and under voltage protection. Bus bar, metering ( incoming and outgoing voltmeter , Ampere meter, Frequency meter) (3-phase current/ 3-phase voltage/ Power factor of running motor, phase indication lamp ( RYB with CTs ), outgoing MCCB for each pump sets/other outgoing points , capacitor Bank for an improved power factor of .95-1, soft starter with over load relays. The control panel shall be complete with single core cupper cable of size90 mm2/15 mm of 50 RMT confirming to IS 694 with thimbles-40 Nos from panel to AVR, Automatic Voltage Regulator to Panel and Panel to Motor having option for 3-wire and 6-wire connections , and 31/2core aluminum cable of 25 RMT of current rating more than 170 Ampere from L.T Pole to Control panel . The 3-phase squirrel cage induction Motors ratings are as follows. i) Rating = 40HP ii) Voltage = 415 ± 10% iii) Frequency = 50HZ
Maintenance free earthling :- S.I.T.C. of long life maintenance free electrolytic earthling with 10 feet vertical type copper not less than 2”(50.8mm)ID and not less than 0.008”(2.03mm) wall thickness , which does not require manual addition of water . The System should be corrosion resistant pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. Rated for high fault currents bus- bar rated for 10KA , fault current bus bar connection type as “Trawled” to with hold temperature of 700®c . The earthling port shall be designed and supplied with poly plastic port cover non conductive, environment friendly and lockable.
FULLY AUTOMATEIC VOLTAGE REGULATOR DULY FILLED WITH RECOMMENDED OIL UPTO FULL CAPACITY Type = Fully Automatic Servo Voltage Regulator Rating= 75 KVA Input Voltage Range (Phase To Phase ) = 270-460 V Output Voltage Range (Phase To Phase ) =415±1% Output Wave Form = True To Input Input Frequency = 45-55 HZ Response Time = 10 Msec Correction Speed = 25-65 V/Sec Correction Method = Stop less Correction Cooling = Oil Efficiency = Better Than 98% Control circuit = Fully Automatic Ic Based Operation = Fully Automatic Suitability = Suitable for 3- phase Unbalanced Supply Unbalanced Load Operating Temperature = -15®c To 45®c Above Ambient Additional Features = i) High and Low Voltage Cutoff System ii) Over Load and Short Circuit Protection iii) Single Phase Prevention System iv) Phase Sequence Change Protection v) Earth Fault Protection vi) High Grade Crgo Lamination vii) Simple Rugged Construction viii) 99.9% Pure Copper ix) High Efficiency x) Negligible wave Form and Power Factor Distortion xi) Smooth and step less voltage control.
Complete Pump Tool Kit Crimping Tool Hydraulic type = 1 No Spanner double ended set = 1 set Ring spanner set = 1 set Screw driver = 1 set Socket = 1 set Grease gun Bucket type = 1 No
Providing/Fitting of HDPE flanged pipe ( joint type ) 4 inch dia. (PN-12.5 PE-100, SDR-Il ) the piping shall be as per the requirements of ISO 4427 And shall be codified for water application (of proven superior quality ) including all the fittings, NRVs etc Complete Job. The job includes earth work in excavation 1.5 M deep /1.5M wide, Providing/lying in position of specified grade of reinforced cement concrete in 1:2:4 including complete shattering for the job. The job includes safe and secured laying of HDPE pipe with RCC Support at appropriate length beneath soil with requisite mechanical protection, Leveling/dressing of soil complete job.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .