Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 CrAdmitted-Finance KADAYIL DEW 1ST FLOOR DOOR NO 1888 NH ROAD SREEKARYAM PO TRIVANDRUM 695017 | THIRUVANANTHAPURAM | KERALA | 695017 | ₹2.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.2 CrAdmitted-Finance DOOR NO V 155 B GROUND FLOOR KOTHARATHU BUILDING NEAR ALPHA PALLIATIVE CARE VENGANELLUR CHELAKKARA THRISSUR KERALA 680586 | THRISSUR | KERALA | 680586 | ₹3.2 Cr | L2 | Admitted-Finance |
| 3 | Rejected-Technical | - | - | Rejected-Technical Failure to comply with the bidding requirements. |
| 4 | Rejected-Technical | - | - | Rejected-Technical Failure to comply with the bidding requirements |
| Sl No | Description | Qty | Unit | Genisys Engineers and Contractors L1 | ITHAL ENGINEERING GROUPS L2 |
|---|---|---|---|---|---|
| 1.01 | Pole PSC 8 M | 546 | E | 4,07,862 ₹22.7 L | 5,01,228 ₹27.8 L |
| 1.02 | Stay Insulator Porcelain 415/240 V | 555 | E | 2,997 ₹16,650 | 3,996 ₹22,200 |
| 1.03 | Clamp GI for LT Stay for Angular location | 858 | E | 13,899.6 ₹77,220 | 15,444 ₹85,800 |
| 1.04 | Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod) | 546 | E | 29,484 ₹1.6 L | 34,398 ₹1.9 L |
| 1.05 | Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire) | 2,554 | kg | 41,374.8 ₹2.3 L | 45,972 ₹2.6 L |
| 1.06 | Bolt& Nut GI FT M 12 x 65 (2 1/2"x 1/2") | 31.6 | kg | 853.2 ₹4,740 | 966.96 ₹5,372 |
| 1.07 | Earthing Coil GI 115 Turns 50 mm internal Dia dia | 104 | E | 3,744 ₹20,800 | 4,680 ₹26,000 |
| 1.08 | Ferrules 5 Sq.mm(GI) | 113 | E | 244.08 ₹1,356 | 305.1 ₹1,695 |
| 1.09 | G.I.WIRE. 4MM (8 SWG) | 163 | kg | 1,907.1 ₹10,595 | 2,200.5 ₹12,225 |
| 1.10 | End Cap for LT ABC 16 Sq mm | 159 | E | 228.96 ₹1,272 | 286.2 ₹1,590 |
Updated dates
Tender Value
₹2.3 Cr
EMD Value
₹1 L
Closing Date
12 Dec 2025, 4:00 pmClosed
EXECUTIVE ENGINEER
Electrical Division Office Pravasi Building Vaniyambalam.
Construction Conversion and Re conductoring of LT lines using LT ABC on Turnkey basis at various locations at Electrical Division Wandoor.
2025_KSEB_816488_1
02/EDWDR/MPM Package/2025-26/28.10.2025
Open Tender
Electrical Works
120 days
Wandoor
Please refer Tender documents.
3 documents required · 3 mandatory
₹8,850
₹1 L
Electrical Division office Wandoor
6 Mar 2026
31 Oct 2025
16 Dec 2025
31 Oct 2025
12 Dec 2025
6 Nov 2025
5 Nov 2025
Pole PSC 8 M
Stay Insulator Porcelain 415/240 V
Clamp GI for LT Stay for Angular location
Stay Rod (Anchor Rod) GI 16 mm dia (LT Stay Rod)
Stay Wire 7/8 (7/3.15mm) GI (HT Stay Wire)
Bolt& Nut GI FT M 12 x 65 (2 1/2"x 1/2")
Earthing Coil GI 115 Turns 50 mm internal Dia dia
Ferrules 5 Sq.mm(GI)
G.I.WIRE. 4MM (8 SWG)
End Cap for LT ABC 16 Sq mm
End Cap for LT ABC 70 Sq mm
Anchoring / Dead end Clamp Assembly for LT AB Cables up to 70 sq.mm (Insulated Messanger up to 50 sq mm)
Stainless Steel Buckle Slot width 20.5 mm x 1.5 mm,Thickness 1.2 mm.
End Cap for LT ABC 50 Sq mm
Stainless Steel Strap 20 mm x 0.7 mm
Suspension Clamp Assembly for LT AB Cables up to 70 sq.mm
Insulation Piercing Connector - Main: 16 sq mm to 95 sq mm; Tap : 16 sq mm to 95 sq mm
Insulation Piercing Connector Main 16 sq mm to 95 sq mm; Tap 4 sq.mm to 35 sq.mm
Aerial Bunched Cable LT 3x70 + 1x16 + 1x50 sq.mm (Insulated Messenger)
Insulation Piercing Satellite connector Main : 16 sq mm to 95 sq mm; Tap : 4 sq mm to 35 sq mm (4 way)
Turn Buckle ,Eye bolt with 2 Nuts 16 mm dia -GI (Stay tightner LT )
Satellite Connector for LT ABC 3X70 + 1X50 + 1X16 Tap 2.5-35 Sqmm(50 Sqmm)(4 way)
Clamp GI For LT Stay/Strut
Bolt & Nut GI FT M 12 x 150 (6"x 1/2")
Insulation Piercing Connector - Main: 16 sq mm to 95 sq mm; Tap : 1.5 sq mm to 16 sq mm
Cable 1.1kV XLPE AL 1c X 120 sq mm (Un Armoured)
Crimping Socket Palm Type 120 Sq.mm -Al (Cable Lug)
Bolt& Nut Brass with 2 plate washers - M 10 x 40 (1 1/2"x 3/8")
Pre- Insulated Crimping Socket Palm Type 50 Sq.mm -Bimetallic (For ABC)
Pre- Insulated Crimping Socket Palm Type 70 Sq.mm -Bimetallic (For ABC)
Pre- Insulated Crimping Socket Palm Type 16 Sq.mm -Bimetallic (For ABC)
FUSE UNIT 415 V 100 A PORCELAIN
FUSE UNIT 415 V 200A PORCELAIN
Cable Tie UV Plastic Heavy Duty 500 mm Length
Insulation Piercing Satellite connector Main : 16 sq mm to 95 sq mm; Tap : 4 sq mm to 50 sq mm (4 way)
Cable Tie UV Plastic Heavy Duty 300 mm Length
Bolt & Nut GI M 12 x 160 (6 1/2"x 1/2")
Anchor Plate 200 x 200 x 6 mm GI (LT Stay Plate GI))
Stainless Steel Buckle Slot width 10.5 mm x 1.5 mm,Thickness 1.2 mm.
Stainless Steel Strap 10 mm x 0.7 mm-For clamping earth wire
Cable 1.1kV XLPE AL 1c X 95 sq mm (Un Armoured)
Pre-Insulated Midspan Joints and Terminal Lugs 70 Sq.mm
Thimble GI 75 mm x 22 mm x 40 mm ,1.5 mm Thickness (For HT and LT)
Helically formed Guy-Grip LT
Pre Insulated Midspan Joint for LT ABC Phase Cable 70 Sq.mm
Pre Insulated Midspan Joint for LT ABC Phase Cable 50 Sq.mm
Pre Insulated Midspan Joint for LT ABC Phase Cable 16 Sq.mm
Cable 1.1kV PVC Insulated AL Twin Core 2.5 Sq.mm PVC Sheathed Weather Proof (TC Weather Proof Wire 1/1.8)
Pre-Insulated Midspan Joints and Terminal Lugs 16 Sq.mm
Crimping Socket Palm Type 95 Sq.mm -Al (Cable Lug)
Stainless Steel Strap [20 mm x 0.7 mm]
Pre-Insulated Midspan Joints and Terminal Lugs 50 Sq.mm
Bolt& Nut GI M 16 x 90 (3 1/2"x5/8")
Bolt & Nut Brass M 12 x 50 (2"x 1/2")
Pin Insulator 11kV Composite Polymeric
GI Wire 4 SWG
Turn Buckle ,Eye bolt with 2 Nuts 20 mm dia -GI(Stay tightner HT)
Pole PSC 9 M
V cross arm -GI -11 kV
Clamp GI for V cross arm
Pole Top Bracket -F Type GI -11 kV
Clamp GI for 2/4 line channel Cross Arm for PSC Poles 200kg
CROSS ARM GI CHANNEL 2 LINE(2 Line channel cross arm) for PSC Poles 8M/200kg
CROSS ARM GI CHANNEL 4 LINE(4 Line channel cross arm) for PSC Poles 8M/200kg
PIN INSULATOR 415V SET(WITH PIN)
Stay Rod (Anchor Rod) GI 20 mm dia (HT Stay Rod)
Helically formed Guy-Grip HT
Anchor Plate 200 x 200 x 8 mm GI (HT Stay Plate GI))
Bolt& Nut GI M 12 x 65 (2 1/2"x 1/2")
POLE A TYPE 11 M
Pipe GI 40 mm dia -2.5 m Length( Earth Pipe)
Stay Insulator Porcelain 11k V
Clamp GI For HT Stay/Strut
Bolt& Nut GI M 16 x 75 (3"x 5/8")
Bolt& Nut GI M 12 x 150 (6"x 1/2")
Insulation Piercing Connector Main 16 sq mm to 95 sq mm; Tap 1.5 sq.mm to 10 sq.mm
Pole Top Distribution Box LT Outdoor 415 V 25 kW (For Connection from ABC)
BoQ_Ver3.0
Tender No::E TENDER NO.02/EDWDR/MPM Package/2025-26/dt28.10.2025
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
Erecting one LT PSC Pole in position incl. digging & back filling pit.
Additional rate for excavation of one Pit for LT Pole/LT Stay in Laterite.
Additional rate for excavation of one Pit for LT Pole/LT Stay in Hard Laterite.
Providing Strut using LT PSC pole incl. digging & back filling pit.
Providing Stay for LT poles incl. digging & back filling pit.
Providing one Coil Earth using GI earth wire, digging separate pit at standard distance away from the pole/structure & backfilling.
Installing One No. 4 way Satellite Connector of size Main :16 to 95, Tap:4 to 35 Sq.mm to the LT AB cable of Standard size
Erection of Anchor clamp / dead end clamp for LT ABC of any size
Erection of suspension clamp for LT ABC of any size
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap 16-95 sqmm
Installation of Insulation piercing connector for main to service line main :16-95 sqmm, Tap : 4-35 sqmm
Dismantling (without damage) one km LT 3ph 4 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Dismantling (without damage) one km LT additional conductor line, cross arms, insulators and stacking the conductors in rolls.
Stringing of 1.1 kV Aerial bunched cable of size 3 x 70 + 1 x 16+1x 50 sqmm with bare/insulated Messenger through existing poles
Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt&nut etc.
Installation of Pre-insulated lugs for 16sqmm
Installation of Pre-insulated lugs for 50sqmm
Installation of Pre-insulated lugs for 70sqmm
Installing One No. Insulation piercing connector of size Main :16 to 95 ,Tap:1.5 to 16 Sq.mm
Renewal of existing damaged/old LT PSC/RCC (3ph line) pole with new PSC pole in place and refitting of all items incl. conveyance (except pole).
Insertion of one LT PSC pole in existing 3ph OH line incl. digging & back filling pit, fitting cross arm, insulator, binding etc.
Renewal of existing damaged/broken old LT stay with existing stay rod.
Installation of Pre-insulated straight through joints for 16sqmm cable
Installation of Pre-insulated straight through joints for 70sqmm cable
Pole numbering using printed Aluminium sheets / Painting the surface of pole with anti algal yellow paint and painting Letters with black paint as specified incl. cost of paint.
Providing Cable Tie
Providing End Caps
Installation of Pre-insulated straight through joints for 50sqmm cable
Renewal of existing damaged/old LT PSC/RCC (Sph line) pole with new PSC pole in place and refitting of all items incl. conveyance (except pole).
Dismantling (without damage) one km LT Sph 2 wire OH line, cross arms, insulators and stacking the conductors in rolls.
Providing spiral earthing
Dismantling and reconnecting Sph service connection from the OH line incl. lowering down the WP portion.
Dismantling and reconnecting 3ph service connection from the OH line incl. lowering down the WP portion.
Dismantling one ordinary street light/CFL/LED fitting from existing pole and refitting the same on newly erected pole and reconnecting.
Dismantling one damaged LT PSC/RCC pole after disconnecting stays, strut etc. and stacking the same.
Insertion of one HT PSC pole in existing HT/LT line incl. digging & back filling pit, fitting cross arm, insulator, binding etc.
Fitting and providing one HT Stay for 11kV pole incl. digging & back filling pit.
Insertion of one HT A type pole in existing line incl. digging & backfilling pit, fitting cross arm, insulators, binding etc.
Providing concrete muffing (0.45x0.45x1.5m) inclusive of cost of all material (as per specification).
Insertion of one HT PSC pole in existing line incl. digging & backfilling pit, fitting cross arm, insulators, binding etc.
Providing one Earth using earth pipe incl. digging separate pit at standard distance away from the pole/structure & backfilling.
Fitting one additional Fuse unit and giving connection from Transformer to fuse and DB to LT OH line.
Installing one pole top service connection box 3ph 6way and giving connections.
BoQ_Ver3.0
Tender No:E TENDER NO.02/EDWDR/MPM Package/2025-26/dt28.10.2025
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
TenderDocument.pdf
Tender Documents • 3.78 MB
approvedvenderlist.pdf
Additional Documents • 0.68 MB
BOQ_1367688.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid