Loading…
Loading…
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Jun 2026, 6:00 pm
GE Clement Town
GE Clement Town MES Dehradun
REPAIR / MAINT OF AC, GEYSER AND OTHER APPLIANCES WITH CONNECTED ITEMS UNDER GE CLEMENT TOWN
2026_MES_770773_1
GE/CLT/ Of 2026-27
Open Tender
Electrical and Maintenance Works
180 days
GE Clement Town
Class E Cat c(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹40,000
Yes
9 Jun 2026
9 Jun 2026
7 Jul 2026
9 Jun 2026
30 Jun 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Identifying and rectifying the minor defect/complaints of any type and nature such as rectification of faulty electric circuit, tightening of loose wiring & connection pertaining to all type of Air conditioner/ Geyser/ desert cooler/ Water Coolers/Refrigerator / Deep Freezer of any type and any capacity including servicing, cleaning, and removing dust by air blower and washing with required solution complete all as specified and directed for the item included following:-.
(a) All T & P and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor daily as directed.
(b) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the rate of quoted item.
(c) Any part need to be replacement will be measured and paid seprately as per respective item of schedule. | 120 | Each job | - | - |
| 2 | WATER COOLERS
Supply, installation and commissioning of water cooler partially stainless steel electric driven single phase having approx storage and normal cooling capacity 40/80 Ltr. | 3 | Each | - | - |
| 3 | Supply, installation and commissioning of water cooler partially stainless steel electric driven single phase having approx storage and normal cooling capacity 60/120 Ltr. | 3 | Each | - | - |
| 4 | S&F in repair sealed compressor unit of any make any type for water cooler of cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, and fixing with new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc and checking the leakage in the system and charging the gas R-22 / R-134 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed. | 8 | Each | - | - |
| 4.1 | All as per item No. 04 here in before but for water cooler of capacity 60 Ltrs/hr complete all as specified and directed | 7 | Each | - | - |
| 4.2 | All as per item No. 04 here in before but for water cooler of capacity 150 Ltrs/hr complete all as specified and directed | 5 | Each | - | - |
| 5 | S&F in repair potential relay box type for water cooler of any capacity complete all as specified and directed | 12 | Each | - | - |
| 6 | S&F in repair relay current type, for water cooler of any capacity complete all as specified and directed | 14 | Each | - | - |
| 7 | S&F in repair rubber hose pipe of 25mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long as per sample kept in GE office complete all as specified and directed. | 40 | Each | - | - |
| 8 | S&F in repair Over load protector assembly complete all as specified and directed. | 10 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.