Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC | ₹1.0 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.1 Cr+₹7.2 L (6.86%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹1.1 Cr+₹7.2 L (6.86%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹1.1 Cr+₹7.3 L (6.97%)Rejected-AOC | ₹1.1 Cr+₹7.3 L (6.97%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹1.1 Cr+₹10.1 L (9.69%)Rejected-AOC EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹1.1 Cr+₹10.1 L (9.69%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹1.2 Cr+₹15.4 L (14.7%)Rejected-AOC | ₹1.2 Cr+₹15.4 L (14.7%) | L5 | Rejected-AOC Rejected |
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
6 May 2024, 6:00 pmClosed
CWE (NW) KOCHI
CWE (NW) KOCHI
SPECIAL REPAIRS AND STRUCTURAL REHABILITATION TO T-5 HANGER AT CTW NAVAL BASE KOCHI
2024_MES_649658_1
CWE(NW)KOCHI/81428
Open Tender
Civil Works
Item Rate
270 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE(NW) KOCHI
₹1.9 L
Yes
6 Sept 2024
8 Apr 2024
8 May 2024
8 Apr 2024
6 May 2024
29 Apr 2024
Amount
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
M&L for Pre-painted galvalume aluminum zinc coating GI based Corrugated steel sheet 0.50mm thick of colour as approved by user having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of colour as approved by user having tensile strength of 550 Mpa as in roof covering/cladding to wall, ridge , Gutter, Gable flashing, corner flashing etc, fixed with self tapping screws as specified and directed.
M&L 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall complete all as specified and directed.
S & F in repair Stainless steel eco friendly turbo ventilator size 600mm for roof complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
S & F of roof trusses (framed or tubular sections) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, tubular pipes or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde-E-165 complete all as specified and directed
S&F Fe 290 (Gde E-165) Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm and removing from site complete all as specified and directed.
All as item No.9 above but exc 1.50 Sqm and n.exc 4.00 Sqm each complete all as specified and directed.
S&F Aluminum powder coated fixed type windows including suitable nylon beading channel gasket etc complete with following specification :- Frame :- 63.50mmx38.10mmx1.50mm Panel :- 4mm thick ACP sheet / 5mm thick tinted/frosted glass/Mosquito proof jali:- Stainless steel jali 0.45mm nominal dia of wire and average width of aperture 1.40mm fixed typof approved colour and design
S&F aluminum powder coated door shutter with frames of size - 44.5mmx50mmx1.5 mm incl. screwing of frame glass necessary joints cleats, glazing clips rubber packing, snap beading, suitable handle, tower bolt, SS butt hinges,mortice lock 4 lever with 65 mm latch size including aluminium anodized door frame of size 63.5mmx 38.10mm x1.5 mm thick fixed to wall with necessary screws and plug complete all as specified & directed. (rates for one no hydraulic door closer per shutter & 5 mm thick tinted glass /4mm thick ACP sheet reqd to be fitted in shutters is included in the item )
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed by Engr-in-Charge.
M&L 75mm thick PCC (1:3:6) type C-1 (Using 20mm graded crushed stone aggregate) as in plinth protection , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L 100 mm thick PCC (1:2:4) type B-1 (Using 20mm graded crushed stone aggregate) as in hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
M&L for precast cement concrete block masonry in type C1, 1:3:6 (20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in foundation load bearing wall and wall complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor complete all as specified and directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Machine cut Kota stone slab 18-20mm thick as in floor/ treads of steps (single piece) laid over and including 15mm thick screed in CM 1:4, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing complete all as specified and directed by Engr-in-Charge.
M&L for machine cut Kota stone slab 18-20 mm thick (single piece) as in risers to steps, skiting/dado, pillars, window cills and the like, laid over and including 10mm thick rendering in cement mortar 1:3, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified and directed by Engr-in-Charge.
Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed
S & F 180 mm width rectangular PVC SWR ready made eaves gutter of pressure rating 6 Kg/cm2 of approved make including necessary fitting like bend WC/MS Clips etc complete all as specified and directed.
S & F 150MM dia of PVC (SWR) pipe single socketed in any length with rubber joints including necessary fitting like bend WC/MS clips etc fixed on walls complete all as specified and directed.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.
M&L for two coats of oil bound distemper over a coat of primer over a coat of 1.5mm thick wall care putty to newly plastered surface including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
M&L Complete removal of existing treatment to wall and applying one coat of wall putty 1.5mm thick (internal or external ) on walls internal or external surfaces in any height complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of primer on internal wall putty surfaces complete all as specified and directed.
M&L for preparing of old steel surfaces of any description over 10 cm in width or girth not otherwise described and applying 2 coats of anti-corrosive paint over a coat of epoxy primer at any height all as specified including all necessary scaffolding work upto 30m height & as directed by the Engr-in-Charge.
M&L for preparing of new steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of anti-corrosive paint over a coat of epoxy primer at any height all as specified and as directed by the Engr-in-Charge.
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
M & L Welded steel wire fabric weight n exc 4 kg/sqm fixed to steel members complete all as specified and directed.
S/F Aluminum snap grid false ceiling with grid 605x605mm size including hangers 6 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flats 40 x 3 mm size 60 mm long & expansion hold fastners 12.5 mm dia 40 mm long complete all as specified and directed.
S/F 4mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium framework with stainless steel screws complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/blankets, any thickness including cover fillets complete all as specified and directed.
Taking down carefully existig copper / alumn point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity all as specified and directed.
Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing complete all as specified and directed.
S&F point wiring with 1.5 Sqmm PVC insulated sheathed FRLS multistranded single core copper conductor cable in PVC concealed conduit rigid non metalic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including chases cutting as reqquired working spot and surface on as existing incl suitable size/ module of sunken box for modular switch and socket and modular white cover plate, flush metal box etc inxl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light/ wall fan point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and as directed. Note- Bldg height/ working spot is more than 7.5 mtrs, rate to be quoted by fired/ contractor with tools & plant/ transportation complete all as specified and directed.
Same as item No. 41 above but one 3 pin 5 Amp socket outlet point controlled by one switch on Independent board complete all as specified and directed.
Same as item No. 41 above but one 3 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and directed.
All as per item No. 41 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, sheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable complete all as specified and directed.
M&L Switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.
M&L Switch modular type 16 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.
S&F Socket outlet modular type 6A - 2 in 1, without shutter, 2 module, duly ISI marked, complete all as specified and directed.
S&F Socket outlet modular type 16A, 3 pin combined, 2 module, duly ISI marked, complete all as specified and directed.
S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed.
S&F rotary Stepped type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 2 module, 120W, white in colour, duly ISI marked complete all as specified and directed. Make- Anchor or equivalent make in the approved manufactures list.
S&F in replacement of LED light fitting 1 x 20 Watt, 220V, 120 Lumen/Watt, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in replacement LED Batten 2x24 Watt, 4 feet, 220-240 Volts, 120 Lumen/Watt, Industrial grade aluminium extrusion, powder coated fitted with high lumen LEDs and milky opal diffuser for glare free light with fixed using hook/ cradle mounting options including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make Cat No. REGALBATTENT8UPTO2X22WSSBSWH & CRYSTALT81213SSTL20WLED865SGLASS or equivalent make in the approved manufactures list.
S&F in replacement circular highbay LED light 150 Watt, 240 Volt, 120 Lumen/Watt, IP66 made upof cast aluminium housing with polycarbonate lenses, suitable for Industrial lighting using hook/ cradle mounting options including provision of flexible copper wire from ceiling rose to light fitting terminal complete all as specified and directed. Make Crompton Cat part No. TIP-320-150-57-SL-GL-NSG or equivalent make in the approved manufactures list.
S&F in replacement of LED bldg security light fitting of 60 watts, 6000K, 120 Lumen/Watt, including GI bracket bend to shape made out of GI pipe light grade of 40 mm, size up to 1.2 mtr long etc complete with two nos of bolts of suitable size, duly painted with two coats of synthetic enameled paint and all fixing arrangements to wall/ pole, including connecting up with 2 core copper flexible wire of size 23/00.0076 all as specified and directed.
S&F in replacement of LED Aviation light-twin type with polycarbonate diffuser and cast aluminium housing, IP65 protection including all fixing arrangements as per manufacturer complete all as specified and directed. Make- Bajaj Cat part No. BGAV 302 LED or equivalent make in the approved manufactures list.
S&F exhaust fan heavy duty with louvers complete of sweep size 300mm, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
S&F exhaust fan heavy duty with louvers complete of sweep size 450mm, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
S&F ceiling fans, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.Make Havells/ Atomberg/ Usha/ Orient Note : Old Ceiling fans to be deposite at AGE E/M (NW) store yard.
S&F wall mounted air circulator fan heavy duty of sweep size 750mm, 1400 RPM, single phase, 220-240 Volts, 50 Hz, complete with all fixing/ hanging arrangements directed by manufacturer on wall or as existing working spot including provision of PVC flexible copper cable of suitable size/ length as reqquired complete all as specified and directed.
S&F in Replacement single pole and neutral 240 Volts, enclosure with three pin and earth plug and socket complete with one DP MCB, 20 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified and directed.
S&F in Replacement triple pole 415 Volts, enclosure with three pin and earth plug and socket complete with one TP MCB, 32 Amps having breaking capacity 10 kA, including taking down old unserviceable eath plug complete all as specified and directed.
Supply, installation, testing and commissioning factory made, LT bus bar panel board cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts IP-65. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x 50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with and comprising of the following : (i) Epoxy insulated 400 Amps rated high conductivity aluminium bus bars, including aluminium lugs to connect the cable. (ii) Incoming MCCB 4 pole, 250 Amps, 415 Volts, 16kA. (iii) Outgoing MCCB 63 Amps, 4 pole -08 Nos
S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 6 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming MCCB and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, IP-43 protection, partly immersed in wall, without MCCB and MCB's including making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F Factory made single phase and neutral sheet steel made out of CRCA 1.2 mm thick, powder coated double door distribution board 12 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F MCCB thermal based release adjustable type 4 pole 63 Amps 50 Hz 415 Volts with rupturing capacity 16 KA including testing, complete all as specified and as directed.
S&F MCB TP, 63Amps, 415 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SPN, 40A - 63Amps, 240 volts, "C" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SP, 6A-32 Amps, 240 volts, "B" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as specified and directed. Note for item No. 63 to 68: Make of MCCB DBs Legrand, L&T, Siemens or equivalent make in the approved manufactures list.
M&L for Sub main wiring with four single core 16 Sqmm FRLS insulated and unsheathed stranded copper conductor cable 1100 volt grade alongwith one run of 16 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn in PVC rigid conduit connected to main board complete all as specified and directed (Four runs cable and one run earth wire and suitable PVC conduit shall measured together as one unit length).
M&L for Sub main wiring with four single core 10 Sqmm FRLS insulated and unsheathed stranded copper conductor cable 1100 volt grade alongwith one run of PVC insulated single core multistranded copper conductor cable as earth continuity conductor 10 Sqmm drawn in PVC rigid conduit connected to main board complete all as specified and directed (Four runs cable and one run earth wire and suitable PVC conduit shall measured together as one unit length).
M&L for Sub main wiring with four single core 6 Sqmm FRLS insulated and unsheathed stranded copper conductor cable 1100 volt grade alongwith one run of 6 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn in PVC rigid conduit connected to main board complete all as specified and directed (Four runs cable and one run earth wire and suitable PVC conduit shall measured together as one unit length).
M&L for Sub main wiring with two single core 10 Sqmm FRLS insulated and unsheathed stranded copper conductor cable 1100 volt grade alongwith one run of 6.0 Sqmm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn in PVC conduit connected to main board complete all as specified and directed (Two runs cable and one run earth wire and suitable PVC conduit shall measured together as one unit length).
M&L for Sub main wiring with two single core 4 sqmm FRLS insulated and unsheathed stranded copper conductor cable 1100 volt grade alongwith PVC insulated single core multistranded copper conductor cable as earth continuity conductor 4 Sqmm drawn in PVC conduit connected to main board complete all as specified and directed (Two runs cable and one run earth wire and suitable PVC conduit shall measured together as one unit length).
M&L for Sub main wiring with two single core 2.5 sqmm FRLS insulated and unsheathed stranded copper conductor cable 1100 volt grade alongwith PVC insulated single core multistranded copper conductor cable as earth continuity conductor 2.5 Sqmm drawn in PVC conduit connected to main board complete all as specified and directed (Two runs cable and one run earth wire and suitable PVC conduit shall measured together as one unit length).
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. Provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. Excavation in soft/ loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009).
Material and labour for earthing complete with galvanized steel plate elecrode of size 60cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level, connected with and including GI strip 32mm x 6mm with & including GI pipe 50mm bore medium grade as protection pipe (upto the body of equipment max 7.50 meter) by means of GI and thimbles, earth plate surrounded packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate and RCC M-25 cover and angle iron frame complete all as specified. Note :- (i) The cost of GI strip/ wire from top of earth plate upto 5.00 meter above GL with GI protection pipe shall be deemed to be included in unit rate. (ii) PCC pit shall be provided at least 0.50 meters away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc. shall be deemed to be included in the unit rate. (iii) In case the testing result of earthing work not found satisfactory, the contractor shall have to carry out earthwork at new location and nothing extra shall be admissible on this account. (iv) The earthing work shall be carried out in presence of MES representative detained by Engr-in-Charge.
S&F XLPE insulated, armoured, 1100 volts grade, heavy duty cable of size 50 Sqmm nominal cross section, 3.5 core, aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified.
S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc complete all as specified.
SHAIJAL T M
M/s ANTONY THOMAS AND CO
Powertech Engineers
Modern Engineering Co
WELTRONENGINEERINGSERVICES
Kurian And Varghese
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .