Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹13.3 L+₹5.0 L (60.8%)Rejected-AOC DOOR NO IV 400 NEAR RAMANTHALI GHSS RAMANTHALI PO KANNUR 670308 | KANNUR | KERALA | 670308 | L2 | Rejected-AOC being L2 |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
10 Mar 2021, 6:00 pmClosed
AGE I Cannanore
AGE I Cannanore HQ Hospital Kannur PO
Repairs/servicing to DG sets and carrying out B checks as recommended by the manufacturer at Kannur and repair/replacement of APFC panel and improvement to power factor at Kannur under AGE (I) Cannanore.
2021_MES_415923_1
8113
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Cannanore
class E cat b (I)
7 documents required · 7 mandatory
₹500
Yes
AGE I Cannanore
₹19,800
Yes
31 Mar 2021
25 Jan 2021
13 Mar 2021
27 Jan 2021
10 Mar 2021
10 Feb 2021
Amount
M&L for carrying out Repair / servicing to DG set of capacity 10KVA by replacing of air filters, fuel filters primary and secondary, Oil filter, Engine Oil (suitable grade) as per manufacture's specifications, , fan belts, battery leads and clamps, checking, serveasing of FIP and other suitable minor parts if required for its smooth functioning and preparation of old painted surfaces and applying a coat of spray painting, writing SM/MES No in white paint as directed by Engineer in charge all as specified and directed. Note: Engine oil shall be measured and paid seperatly.
All as per item No 1 here in before but 15 KVA all as specified and directed.
All as per item No 1 here in before but 30 KVA all as specified and directed.
All as per item No 1 here in before but 62.5 KVA at Military Hospital and DSC New Record office all as specified and directed.
Supply and toping up of radiator coolent sutable for Kirloskar Engine for DG Sets all as specified.
Supply only Engine oil as per manufacturers specifications for Kirloskar Engine DG Sets all as specified.
Taking out/removing/dismantling of Dynamo set complete from 15/30 KVA DG set, serveacing of dynamo complete including replacing of carbun brush set, cleaning of commutator, rewinding of dynamo with suitable size enamelled copper wire and replacement of small worn out parts, reassembling, refixing, testing complete all as directed.
All as per item No 7 here in before but for 62.5KVA DG set all as specified and directed.
Taking out/removing/dismantling of Self starter assembly complete from 10 KVA DG set, serveacing of self starter complete including replacing of carbun brush set, cleaning of commutator, rewinding ofself starter with suitable size enamelled copper wire,and replacement of small worn out parts, reassembling, refixing, testing complete all as directed.
S & F of self starter assembly, 12 Volt suitable for 30/62.5 KVA DG Set, testing, commissioning including taking out/removing of unserviceable starter assembly complete all as directed.
Supply and connecting lead acid battery 12 Volt, 90 AH, maintenance free type of Exide/Amron/TATA or equivalent including dismantling of old unserviceable battery all as specified and directed.
Supply and connecting battery terminal suitable for 90 AH battery including dismantling of old unserviceable terminal all as specified and directed.
S&F On-Load Change over switch four pole with sheet metal enclosure, 63 Amps, 415 volts of Model No: ITAE0063 of Make IndoAsian or equivalent in Havells/CG electrically connected including taking out old unserviceable change over switch all as specified and directed.
S&F On-Load Change over switch four pole with sheet metal enclosure, 100 Amps, 415 volts of Model No: ITAE00100 of Make Indo Asian or equivalent in Havells/CG electrically connected including taking out old unserviceable change over switch all as specified and directed.
S&F MCCB, 100 Amps, 415 volt, 50 Hz, repturing capacity 16 KA. Suitable as per existing model of Indo Asian or equivalent in Havells/CG electrically connected including taking out all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit vertically to a depth of not less than 2.25 m below ground level) with top edge of plate at a depth of not less than 1.5 m below normal ground level, connected to galvanized iron strip of 25 x 3 mm as earth lead and all as directed. by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, continuous earth lead protected by using GI pipe light grade 40mm bore, 20 mm dia GI pipe medium grade for watering funnel including necessary excavation, earth work in any type of strata, PCC pit and RCC chamber cover complete all as specified and as shown in electrical plate No 3 of SSR Part-I including dismantling old unserviceable earthing all as directed. Note :- Rate quoted shall deem to include for GI earth wire and GI pipe lead upto 7.5m length.
S&F Automatic voltage regulator suitable for 10 to 30KVA Kirloskar DG set of make Indo Asian or equivalent in Havells/CG electrically connected including taking out all as specified and directed.
Taking down/removing of following unserviceable items from the existing Automatic power factor correction (APFC) panel of three phase 415 Volt, 50Hz system of capacity 30/40/50 KVAR and Supply and fixing Cylindrical capacitors 440 V, 50 Hz, 3 phase, 5 KVAR of model torrent of Havells or equivalent in L&T and connecting up complete all as directed.
All as per item No 18 here in before but Digital power factor display unit complete suitable for 30 to 50KVAR Havells make APFC panel in lieu and connecting up complete all as directed.
All as per item No 18 here in before but cylindrical capacitors 440V, 50Hz, 3 phase 10 KVAR of model torrent of Havells or equivalent in L&T and connecting up complete all as directed.
Taking down/removing of following unserviceable items from the existing Automatic power factor correction (APFC) panel of three phase 415 Volt, 50Hz system of capacity 30/40/50 KVAR and Supply and fixing Capacitor duty contactor type MO C 12.5, 440V, 50Hz, 3 phase, of Havells or equivalent in L&T and connecting up complete all as directed.
Taking down/removing unserviceable LT feeder pillar panel, out door type by switching off power supply and Supply, install, testing and commissioning of new LT feeder pillar panel, CPRI approved make from the list att, outdoor cubical type double door, dust, vermin, weather proof with front opening made out of 3.15 mm thick CRCA sheet with 50x50x5 mm angle iron frame/legs at bottom floor mounted, double door, with neopene gasket and locking arrangement of size 0.5 m x 0.duly powder coated on all sides/surface internally and externally with earth terminals on two sides mounted on and including PCC foundation with PCC 1:2:4 type B2, with and inclussive of following:- Location : MH Kannur (a) MCCB 4 pole ,35 KA, 415 volt, with thermal magnatic release 160 amps - 01 No (Incoming) (b) MCCB 4 pole ,25 KA, 415 volt, with thermal magnatic release 63amps - 06 No (outgoing) (c) MCB TPN 40amp, 415V- 02 No (d) MCB SPN 32amp, 415V- 01 No (e) Bus bar set of aluminium 200 amps for R,Y,B and100 amps for neutral- 01 set. (f ) Indicating lamps for R,Y,B -01 set. (g) Internal wiring of panel board with suitable size FRLS grade copper cable of 1100 Volt with connection through copper lugs /thimbles at ends - 01 Job Note: Rate quoted shall included electrical connection of cable at both ends through cable glands/aluminium lugs.
Preparation of old treated surfaces of LT panel of size 0.9 m x 1.3 m x 0.4m (new record office) complete and applying spray painting by using spray gun, compressor and stand by DG set of suitable capacity, two coats of synthetic enamel paint (externally and internally) of smoke grey colour over one coat of red oxide primer, including writing incoming/out going locations in white colour of suitable font all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 1.4 m x 1.50 mx 0.5m ( OTM pump house and OTM A block) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 1.1 m x 1.25 m x 0.4m (OTM pump house & Offrs mess) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 0.9 m x 1.20 M x 0.3 m (Offrs mess) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 0.9 m x 1.0 m x 0.4m (WL-1 &OTM PH) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 1.9 m x 1.80 m x 0.4 m (OTM_________) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 1.10m x 1.30 m x 0.4m (New Record office) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size1.6 m x 1.85 m x 0.4 m (INP transformer yard) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 1.65m x 1.35 m x 0.4m ( Take over point) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size1.8 m x 1.45 m x 0.4 m ( MH transformer yard) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 2.2 m x 2.5 m x 0.4m (old record office) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 0.9 m x 0.7 m x 0.4 m (Take over point transformer yard) all as directed by Engineer in Charge.
All as per item No 24 here in before but of size 0.7 m x 1.0 m x 0.4m (INP transformer yard) all as directed by Engineer in Charge.
Repairing to existing LT panel at site by welding the hinges, replacing of panel side/back cover sheet as per existing size as required at site, preparation of old treated surfaces of panel of aprox size 0.5 mx 0.6mx 0.35m and applying spray painting by using spray gun, compressor and stand by DG set of suitable capacity, two coats of synthetic enamel paint (externally and internally) of smoke grey colour over one coat of red oxide primer. Replacing of all internal panel board wiring with PVC insulated copper wire of 4/6 sqmm complete all as directed by Engr-in-Charge. ( Location- Offrs mess & RA line transformer yard).
Dismantling old unserviceable DG set 5 KVA from MH pump house and shifting to MES store yard, distance upto 3 kilometer complete all as directed by Engineer-in-charge. Note : The T&P / vehicles etc will be arranged by the contractor and the cost deemed to be included in the quoted rates.
Dismantling old unserviceable DG set 5 KVA from Payyambalam pump house and shifting to MES store yard, distance upto 3 kilometer complete all as directed by Engineer-in-charge. Note : The T&P / vehicles etc will be arranged by the contractor and the cost deemed to be included in the quoted rates.
Supply and fixing MCCB , 4 pole, 100 Amps, adjustable type, rupturing capacity 25 KA, 415 Volts connecting up including taking down/removing of U/s MCCB from existing LT panel after disconnecting electric connetion complete all as specified.
Supply and fixing MCB , TPN, 415 volt, 63 amps, C curve, including taking down/removing of U/s MCB from existing LT panel after disconnecting electric connetion complete all as specified.
M & L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit vertically to a depth of not less than 2.25 m below ground level) with top edge of plate at a depth of not less than 1.5 m below normal ground level, connected to galvanized iron strip of 25 x 4 mm as earth lead and all as directed. by means of bolts, nuts, check nuts and washers of galvanized iron or steel connected to earthing test point, continuous earth lead protected by using GI pipe light grade 40mm bore, 20 mm dia GI pipe medium grade for watering funnel including necessary excavation, earth work in any type of strata, PCC pit and RCC chamber cover complete all as specified and as shown in electrical plate No 3 of SSR Part-I including dismantling old unserviceable earthing all as directed. Note :- Rate quoted shall deem to include for GI earth wire and GI pipe lead upto 7.5m length.
Sreekrupa Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .